FL# FL14645-R2
Application Type Revision
Code Version 2014
Application Status Approved
Comments
Archived ❑
Product Manufacturer Metal Sales Manufacturing Corporation
Address/Phone/Email 545 South 3rd Street,Suite 200
Louisville,KY 40202
(812) 218-7342
dstermer@metalsales.us.com
Authorized Signature David Stermer
dstermer@metalsales.us.com
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
P
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
P
Florida Professional Engineer
Evaluation Report-Hardcopy Received
Florida Engineer or Architect Name who developed Bala Sockalingam
the Evaluation Report
Florida License PE-62240
Quality Assurance Entity Keystone Certifications,Inc.
Quality Assurance Contract Expiration Date 12/31/2020
Validated By Yoosef Lavi,P.E.
147 Validation Checklist- Hardcopy Received
Certificate of Independence FL14645 R2 COI CertificateIndeoendence.odf
Referenced Standard and Year (of Standard) Standard Year
FM 4470 1992
TAS 125 2003
UL 1897 1998
UL 1897 2004
UL 580 1994
UL 580 2006
Equivalence of Product Standards
Certified By Florida Licensed Professional Engineer or Architect
FL14645 R2 Equiv TestEguivalentC2010 UL.Ddf
Sections from the Code
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A7... 3/28/2017
Florida Building Code Online Page 2 of 4
Product Approval Method Method 1 Option D
Date Submitted 03/31/2015
Date Validated 04/14/2015
Date Pending FBC Approval 04/18/2015
Date Approved 06/23/2015
Summary of Products
FL# Model, Number or Name Description
14645.1 2.5" Corrugated Min. 26 ga., 21.33" wide coverage through fastened roof
panel over min. 19/32"thick plywood deck.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II EvaluationReDOrtC2010 1.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-86.0 Evaluation Reports
Other: Uplift load of 82.3 psf at fastener spacing of 36"o.c. FL14645 R2 AE EvaluationReportC2010 i.pdf
and 86.0 psf at fastener spacing of 12" o.c. Created by Independent Third Party:Yes
14645.2 SV Crimp Min, 26 ga., 24 wide through fastened roof panel over min.
19/32"thick plywood deck with fasteners through panel flat.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 2.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-149.6 Evaluation Reports
Other: Uplift load of 84.5 psf at fastener spacing of 24" FL14645 R2 AE EvaluationReportC2010 2.1)df
o.c., 131.3 psf at fastener spacing of 18"o.c.and 149.6 psf Created by Independent Third Party: Yes
at fastener spacing of 12" o.c.
14645.3 SV Crimp Min. 26 ga., 24"wide through fastened roof panel over min.
19/32"thick plywood deck with fasteners through panel rib.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 3.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-196.75 Evaluation Reports
Other: Uplift load of 41.6 psf at fastener spacing of 36" FL14645 R2 AE EvaluationReportC2010 3.1)df
o.c., 74.8 psf at fastener spacing of 16"o.c.and 196.75 psf Created by Independent Third Party: Yes
at fastener spacing of 8" o.c.
14645.4 5V-Crimp Min. 26 ga., 24"wide through fastened roof panel over min.
15/32"thick plywood deck or 7/16" thick OSB with fasteners
through panel rib.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 4.odf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party:Yes
Design Pressure: +N/A/-172.5 Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 36"o.c. FL14645 R2 AE Evaluation Repo rtC2010 4.odf
and 172.5 psf at fastener spacing of 6"o.c. Created by Independent Third Party:Yes
14645.5 Aluminum Classic Rib Nom.0.032" thick,36"wide,aluminum through fastened
roof panel over min. 15/32"thick plywood deck or 7/16"
thick OSB.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II EvaluationReportC2010 5.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A Created by Independent Third Party: Yes
Design Pressure: +N/A/-120 Evaluation Reports
Other: Uplift load of 30 psf at fastener spacing of 36"o.c. FL14645 R2,AE Eva Iuation Repo rtC2010 5.odf
and 120 psf at fastener spacing of 6"o.c. Created by Independent Third Party: Yes
14645.6 Aluminum Vertical Seam Nom. 0.032" thick, 16"wide,aluminum standing seam roof
panel over min. 15/32"thick plywood deck or 7/16"thick
OSB.
Limits of Use Installation Instructions
Approved for use in HVHZ: No FL14645 R2 II EvaluationReoortC2010 6.pdf
Approved for use outside HVHZ: Yes Verified By: Bala Sockalingam PE,62240
Impact Resistant: N/A Created by Independent Third Party:Yes
http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe 8A7... 3/28/2017
Ffie Copy
EVALUATION REPORT OF
METAL SALES MANUFACTURING CORPORATION
126 GA.5V-CRIMP PANEL'
MAR 2 7 201E
PERMITTING
FLORIDA BUILDING CODE 5TH EDITION(2014) St. Lucie county, FL
FLORIDA PRODUCT APPROVAL
FL 14645.3-R2
ROOFING
METAL ROOFING
Prepared For:
Metal Sales Manufacturing Corporation
545 South 31 Street, Suite 400
Louisville,KY 40202
Telephone: (502) 8554300
Fax: (502) 8554290
Prepared By:
Bala Sockalingam,Ph.D., P.E.
Florida Professional Engineer#62240
1216 N Lansing Ave.,Suite C
Tulsa, OK 74106
Telephone: (918)'492-5992
FAX: (866)366-1543
This report consists of
Evaluation Report(3 Pages including cover)
Installation Details (1 Page)
50CKAt����i�
E Nsc�'•�'92�'.
No 62240
Report No. C2010-3
STATE OF
Date: 3.27.15 :0 -
�� •.,
A1-
3.3G ,2ot �
FL 14645.3-R2
C2010-3
• 3.27.15
r , Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24" wide coverage with(5) 1/2" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
painted steel ASTM A755 .
Galvalume coated steel(ASTM A792) or pain ( )
Deck Description: Min. 19/32" thick plywood for new and existing constructions.
Designed and installed as per FBC 2014.
Deck Attachment: 8d x 2.5" long ring shank nails or#8 x 2" long wood screws @ 6" o.c.
(Minimum) in the plywood field and @ 4" o.c. at edges
New Underlayment: Minimum underlayment as per FBC 2014 Section 1507.4.5.1.
Required for new construction and optional fqr reroofing construction.
Existing Underlayment: One layer of asphalt shingles over one layer of#30 felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2014 Section 1507.4.2
Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c.
(Factor of Safety=2) 74.8 psf @ fastener spacing of 16" o.c.
196.75 psf @ fastener spacing of 8" o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
shall be of sufficient length to penetrate through the deck a minimum
of 3/8 .
At panel ends @ 6 o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2014 Section 1507.4
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2014 Section 1505 and current
FL 14645.3-R2
• C2010-3
3.27.15
- Page 3 of 3
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
Supporting Documents: TAS 125 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T181-05, Reporting Date 7/21/05 (Tests#1 &2)
Project No. T240-09, Reporting Date 9/22/09
Architectural Testing, Inc.—West Palm Beach, FL
(Formerly Hurricane Test Laboratory, LLQ
Project No. 0103-0712-09, Reporting Date 9/l/09
onArm�er: cccnm er:
BS OS
P=. �l/23/15
EXISTING SHINGLES SEE DETAIL 2 SEE DETAIL ) NEW UNDERLAYMENT FASTENER AT PANEL FLAT 5V-CRIMP k
(OPTIONAL) r �- (PANEL OVERLAP) NEW CONSTRUCTION)REQUIRED ONLY
ENDSREQU ONLY.RED
PANEL S
a
Ak
ri
EXISTING UNDERLAYMENT PANEL FASTENER PER ALLOWABLE o
(OPTIONAL) MINIMUM ATTACHMENT: PRESSURE TABLE ON THIS SHEET.
8d x 2.5" LONG RING SHANK NAIL
OR #8 x 2" LONG WOOD SCREWS
SPACED 0 6" O.C. IN THE FIELD & Pi
MIN. 2X_ WOOD RAFTER/JOIST/ 4" O.C. AT PLYWOOD EDGES
TRUSS AT MAX. 24" O.C. --
TYPICAL PANEL INSTALLATION X—SECTION N
CD W N
Z f=O
7N
#9-16 OR #10-14 WOODSCREWs - ALLOWABLE UPLIFT PRESSURE � l
WITH SELF SEALING WASHER AT
NEW UNDERLAYMENT MAXIMUM SPACING OF 36" O.C. FASTENER PRESSURE CLiln
(REQUIRED ONLY FOR
NEW CONSTRUCTION co
SPACING (pgF) "�� I
(IN) w FLn0i
00
EXISTI NG N(OPTI SHINGLES MIN 28MGA. 36 41.6 �tad En-J
t
16 74.8 4 u7
8 196.75
u1
W 4.
EXISTING UNDERLAYMENT _ m
(OPTIONAL) PLYWOOD
19/32" THICK (MIN.) GENERAL NOTES
q
DETAIL I 2
FLORIDA BUILDING
CODE
(FBC)2, ROOF 6 GAE( DESIGNED I ACCORDANCE
t 0.0169). EFFECTIVE HE
VECOVERING
9-16 OR 10-14 WOODSCREWS WIDTH OF PANEL = 24". �
WITH SELF SEALING WASHER AT 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS _ N N
NEW UNDERLAYMENT SPECIFIED ON THIS DRAWING. r °
MAXIMUM SPACING OF 36" O.C.
(REQUIRED ONLY FOR 4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS NEW CONSTRUCTION) PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS a
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING.
EXISTING SHINGLES 5V-CRIMP 5. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
(OPTIONAL) MIN 26 GA. _._ BUILDING CODE. IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS.
EXISTING UNDERLAYMENT PLYWOOD
(OPTIONAL) DETAIL 2 19/32" THICK (MIN.) 20�0-3