Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Product Approval
, ualif U Can-Trust... _ [ ( IT)lu�orlh An��nca's CH � , A YE• aI/ i. Largesf a[� Hoaflnr�ll��,�tJaC(t tern i To:GAF Residential Sales,GAF Contractors,GAF Field Services ' From:-technical Services Department Issued Date:05/27/2011 Revised Date:08/17/2016 w Subject:Roofing Over Existing Shingles No:TAB-R-2011-145' "u Can GAF Shingles Be Yes,GAF shingles can be installed over existing strip shingles,T-lock shingles,wood shingles, Installed Over Existing laminated shingles,and other asphalt premium shingles. Shingles? What Is Required To There are a few things that must be followed for a successful installation over an existing roof... Roof Over Existing First,there should only be one existing roof in place. Most local codes do not allow roofing over more than one roof for a total of two roofs in place on a residence. If there is more than Shingles? one roof in place,a complete tear-off is necessary. ■ The existing roof should provide a smooth surface. o Remove all loose or protruding nails or fasteners o Nail down any loose,curled,or lifted asphalt shingles o Split badly curled and/or warped wood shingles and re-nail the individual pieces o Replace any missing shingles When Should A Complete The existing roof should be torn off when... Tear-Off Occur? There is more than one existing roof in place...a tear-off may be necessary as required by local codes. ■ The surface of the old shingles is warped,curled,or so badly weathered to the point where providing a level surface for the new material will be difficult. ■ There are any concerns about deterioration to the deck itself...if the roof is being re-roofed due to extensive leakage, removing the existing roofing materials of the underlying deck. If the deck is deteriorated, it should also be replaced. Shingles Should Not Be GAF asphalt shingles should not be installed over: Installed Over... ■ wood shakes ■ Tile roofs ■ Metal roof Asbestos shingles ■ Roll roofing ■ Low slope membrane roofs ■ Insulation (direct application) ■ Decks other than wood unless an approved specialty deck Note: This is not an exhaustive list. For installation over any substrate other than a wood deck or ('` an existing shingle lamduct as d'escribed•aboove, please con'tact GAF Techwical-Services for requirements and/or acceptability. Where Can I Get More GAF Technical Services Can Assist You...with these and other questions you may have regarding Information? your new roof installation. GAF Technical Services can be contacted at 800-ROOF411(800-766- 3411). Also,the GAF website is a great resource for just about any question you may have or for additional information you may require. Please visit www.gaf.com to find the latest information on our products and their installation. Important:This document supersedes any prior GAF Technical Advisory Bulletins on this topic. Please always check www.gaf.com to make sure you have the most up to date information. I L Y, .:'dAwi3 BCIS Home Log In User Registration Hot Topics Submit Surcharge Stats&Facts Publications Contact Us BCIS Site Map Links I Search .� Fl rich 4 ; ;Product Approval �2- 1 D J :USER: Public User I REVIEWED FOR Product Approval Menu > Product or Application Search >Application List>Application Detail CODE COMPLIANCE q FL # FL31588-R2 ST. LUCIE COUNTY Application Type Affirmation BOCC Code Version 2020 Application Status Approved f ` I / 21 Comments Archived k)Ue C(jpy Product Manufacturer GAF Address/Phone/Email 1 Campus Drive Parisppany, N] 07054 (800) 766-3411 mstieh@gaf.com Authorized Signature Robert Nleminen Irelth@nemoetc.com Technical Representative Michael Stleh Address/Phone/Emall 1 Campus Drive Parsippany, N] 07054 (973) 628-3000 mstieh@gaf.com Quality Assurance Representative Address/Phone/Email I Category Roofing Subcategory Asphalt Shingles Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer C Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity UL LLC Quality Assurance Contract Expiration Date 02/12/2023 Validated By John W. Knezevich, PE L i Validation Checklist - Hardcopy Received Certificate of Independence FL 588 p 2 COI 02 0 COI NIE I EN. d 31 R 2 0 1C MN Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By Sections from the Code 104.11 1504.6 1507.2.7.1 1523.6.5.1 R905.2.6.1 I affirm that there are no changes in the new Florida Building Code which affect my product(s) and my product(s) are in compliance with the new Florida Building Code. Documentation from approved Evaluation or Validation Entity Yes 0 No 0 N/A FL31588 R2 COC 2020 10 15 AFFIRMATION FL31588-112 7TH EDITION.p-df ' r Product Approval Method Method 2 Option B Date Submitted 10/15/2020 Date Validated 10/15/2020 Date Pending FBC Approval Date Approved 10/19/2020 Summa of Products FL # Model, Number or Name Description 31588.1 Royal Sovereign (for HVHZ) Fiberglass reinforced, 3-tab asphalt roof shingle Limits of Use installation instructions Approved for use in HVHZ: Yes FL31588 R2 II 2020 08 10 FINAL ER GAF ASPHALT Approved for use outside HVHZ: No SHINGLES FL31588-Rl HVHZ pd Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use. Evaluation Reports FL31588 R2 AE 2020 08 10 FINAL ER GAF ASPHALT SHINGLES FL31588-R1 HVHZ 12f Created by Independent Third Party: Yes 31588.2 Royal Sovereign (for NON-HVHZ) Fiberglass reinforced, 3-tab asphalt roof shingle Limits of Use Installation Instructions Approved for use in HVHZ: No FL31588 R2 II 2020 08 10 FINAL ER GAF ASPHALT Approved for use outside HVHZ: Yes SHINGLES FL31588-RI NON-HVHZ pdf Impact Resistant: N/A Verified By: Robert Nieminen PE-59166 Design Pressure: N/A Created by Independent Third Party: Yes Other: Refer to ER Section 5 for Limits of Use. Evaluation Reports FL31588 R2 AE 2020 08 10 FINAL ER GAF ASPHALT SHINGLES FL31588-RI NON-HVHZ pdf Created by Independent Third Party: Yes Sack Next Contact Us:: 2601 illair Stone Road,Tallahassee FL 32399 phone: 850-487-1824 The State of Florida is an AA/EEO employer.Qop_ydght 2007-2013 state of Florida. :: Privacy Statement::AccessibiNtv_ktatement:: Refund Statement Under Florida law,email addresses are public records. If you do not want your e-mail address released In response to a public-records request,do,not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail. If you have any questions, please contact 850.487,1395. *Pursuant to Section 455.275(1), Florida Statutes,effective October 1,2012, licensees licensed under Chapter 455, F.S.must provide the Department with an email address If they have one.The emails r . provided may be used for official communication with the licensee. However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public.To determine If you are a licensee under Chapter 455,F.S.,please click here. Product Approval Accepts: Fall aGheco I r MEMO I etc. Certificate of Authorization#32455 353 Christian Street, Unit#13 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT EVALUATION REPORT GAF Evaluation Report 3m-GAF-20-FBCER.A-R1 1 Campus Drive FL31588-R1(NON-HVHZ) Parsippany, NJ 07054 Date of Issuance:02/14/2020 (800)766-3411 Revision 1:08/10/2020 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The products described herein have been evaluated for compliance with the intent of the 6th Edition(2017)Florida Building Code sections noted herein. DESCRIPTION: Royal Sovereign®Asphalt Roof Shingles for use in NON-HVHZ jurisdictions LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1/R905.2.6.1 CONTINUED COMPLIANCE: This Evaluation Report is valid until the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s),the Quality Assurance or the production facility location(s). NEIVIO I etc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO I etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed,then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4. Prepared by: Robert J.M. Nieminen P.E. .fi.,�,'�c;�?i;? The facsimile seal appearing was authorized by Robert ' '':,°+` :•'�? Nieminen,P.E.on 08/10/2020.This does not serve as an Florida Registration No.59166,Florida DCA ANE1983 electronically signed document. CERTIFICATION OF INDEPENDENCE: 1. NEM01etc. does not have, nor does it intend to acquire, or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO l etc.is not owned,operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen,P.E.does not have nor will acquire,a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen,P.E.does not have,nor will acquire,a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither MEMO I etc.nor Robert Nieminen,P.E.are,in any way,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. ©2019,NEW ETC,LLC r OMEMO I etc. ROOFING SYSTEMS EVALUATION: e• Product Category: Roofing Sub-Category: Asphalt Shingles Compliance Statement: Royal Sovereign® Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the intent of the following sections of the 61 Edition(2017) Florida Building Code. Compliance. is subject to the Installation Requirements and Limitations/Conditions of Use set forth herein. e AR Section Property 104.11 Alternative materials 1504.6 Accelerated Weathering 1507.2.7.1,R905.2.6.1 Wind Resistance 1523.6.5.1 Wind Driven Rain REFE!R_ENCE$- Entity Examination Reference Date ICC-ES(EVL2396) 2018&20151BC/IRC ESR-3267 12/01/2019 UL,LLC.(TST 9628) ASTM G155,ASTM D3161,ASTM D7158,TAS 100 12CA61054 11/16/2012 UL,LLC.(QUA 9625) Quality Control Service Confirmation 02/13/2020 ee D' ESCRIPTION1 TABLE 1:ASPHALT SHINGLE COMPONENTS' Type Product Description Material Standard* Plants) Property Method Result Loss on heating ASTM D228 max.1.5% Sliding on heating max.1/16-inch Tear strength ASTM D1922 per min.3.75 Ibs D228 Penetration,asphalt ASTM D5 min.15 Fiberglass Softening point,asphalt ASTM D36 190<°F<320 Asphalt Royal reinforced, Fastener pull-through ASTM D3462 @73°F:min.20lbf CA,FL,Shingles Sovereign® 3-tab resistance @32°F:min.23 Ibf GA,IN, asphalt roof Pliability at 737 ASTM D3462 4 of 5 pass PA,TX shingle Granule embedment ASTM D4977 max.1 g Weather resistance ASTM G155, no cracks,erosion or Cycle 1,2000 hrs exposed felt Breaking strength,after ASTM D146, min.80%retained weathering Section 13 strength Wind driven rain TAS 100 pass "Test options per FBC 104.11.2 MEMO ETC,LLC Evaluation Report 3m-GAF-20-FBCER.A-R3 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL31588-RI(NON-HVHZ) GAF Royal Sovereign Asphalt Roof Shingles Revision 1:08/10/2020 Page 2 of 4 r ONEMOletc. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither NEMO ETC,LLC nor Robert Nieminen,P.E.are,in anyway,the Designer of Record for any project on which this Evaluation Report,or previous versions thereof,is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC High Velocity Hurricane Zone jurisdictions(i.e., Broward and Miami- Dade Counties). 5.3 This Evaluation Report pertains to above-deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. 5.4 This Evaluation Report does not include evaluation of fire classification. Refer to FBC 1505 for requirements and limitations regarding roof assembly fire classification. Refer to FBC 2603 for requirements and limitations concerning the use of foam plastic insulation. 5.5 Wind Classification:Refer to Section 6 for installation requirements to meet wind classifications. TABLE 2A:WIND CLASSIFICATIONS,ASPHALT SHINGLES Product FBC Table 1507.2.7.1 or R905.2.6.1 Royal Sovereign® ASTM D3161(F)& ASTM D7158(H) 5.5.1 Classification by ASTM D7158: ASTM D7158,Class H applies only to exposure category B or C and a building height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.6 All components in the roof assembly shall have quality assurance audit.in accordance with F.A.C. Rule 614320-3. Refer to the Product Approval of the component manufacturer for components that are produced by a Product Manufacturer other than the report holder on Page 1 of this Evaluation Report. 6.1 GENERAL: 6.1.1 Roof deck, slope, underlayment and fasteners shall comply with FBC 1507.2 / R905.2 and the shingle manufacturer's minimum requirements. 6.1.2 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval,or be Locally Approved per Rule 61G20-3, per FBC Sections 1507.2.3, 1507.2.4 or R905.2.3. 6.2 ASPHALT SHINGLES: 6.2.1 Installation of Royal Sovereign®Asphalt Roof Shingles shall comply with the GAF current published instructions, using minimum four(4)nails per shingle in accordance with FBC 1507.2.7 or R905.2.6. 36"(914mm) ` Self-seal adhesive on front IT 11'-13' 11'-13' Autosellante al frente (279mm-333mm)--► I-(279mm-333mm) 12" .� �.. .�.. �... ,.,_.I 0(305mm) � 5-1/4'-6-112' 1/2'-2-1 IT 1/2'-2-1/2'- (133mm-165mm) (13mm-64mm) (13mm-64mm) STANDARD NAILING PATTERN—four nails per shingle NEMO ETC,LLC Evaluation Report 3m-GAF-20-FBCER.A-R1 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL31588-Rl(NON-HVHZ) GAF Royal Sovereign Asphalt Roof Shingles Revision 1:08/10/2020 Page 3 of 4 r r NNEMO-1-etc. 36"(914mm) 2°-s• Self-seal adhesive on front 2°-s• (51mmm-152mm) (51mm-152mm) Autoselllantealfrente 12" — —f � '-1 ;395mm) 0 0 0 0 _ -� 1 • 5-1/4'-6-1/2' f 1 `-2-1 ./// 133mm-165mm /2 /2 ( ) (13mm-64mm) (13mm-64mm) ENHANCED NAILING PATTERN—six nails per shingle* 6.2.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. 6.2.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal,special methods of fastening are required. Contact the GAF for details. 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1/R905.2.6.1. 7.3 The Royal Sovereign®Asphalt Roof Shingles evaluated herein are defined on the packaging as follows: ✓ Florida Statewide Product Approval FL31588 a. BUILMW PERMIT a As required by the Building Official or Authority Having Jurisdiction to properly evaluate the installation of this product. Contact the named CIA entity for manufacturing facilities covered by F.A.C.Rule 61G20-3 CIA requirements. Refer to Section 4 herein for products and production locations. o UL LLC—QUA9625;(414)248-6409;karen.buchmann@ul.com - END OF EVALUATION REPORT- NENIO ETC,LLC Evaluation Report 3m-GAF-20-FBCER.A-R3 Certificate of Authorization#32455 6T"EDITION(2017)FBC NON-HVHZ EVALUATION FL31588-R1(NON-HVHZ) GAF Royal Sovereign Asphalt Roof Shingles Revision 1:08/10/2020 Page 4 of 4