HomeMy WebLinkAboutEnergy CodeW'd
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 18 Block 5 Waterstone 1635 BGL
Builder Name: ADAM HOLESStreet:
5369 San Benedetto Place
Permit Office:�C
alp
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:Owner:
Location: FL, STLUCIECOINTL
Jurisdiction: 661000punt r PermittingDesign
County: St. Lucie (0e, Z e
1. New construction or existing New (From Plans)
9. Wall Types (1573.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1399.30 ft2
b. Frame - Wood, Adjacent
R=13.0 174.22 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1635.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1635.00 ft2
6. Conditioned floor area above grade (ft2) 1635
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c.
R= ft2
11. Ducts
R ft2
7. Windows(204.8 sqft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6 327
a. U-Factor: Dbl, U=0.33 152.55 ft2
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 18.33 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.31
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ft2
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: other (see details) 16.19 ft2,
a. Electric Heat Pump
28.2 HSPF:8.50
SHGC: other (see details)
Area Weighted Average Overhang Depth: 3.483 ft.
Area Weighted Average SHGC: 0.276
14. Hot water systems
8. Floor Types (1635.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1635.00 ft2
b. Conservation features
EF: 0.940
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.125 Total Proposed Modified Loads: 59.15
PASS
Total Baseline Loads: 59.39
I hereby certify that the plans ications covered
e w of the plans and
-TYRE S74��
this calculation are in comp' n h the Flori rgy
specifications covered by this
= p
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARED BY:
Before construction is completed
d
DATE: 11-09-9f19f1 Winn KPnmany
this building will be inspected for
compliance with Section 553.908
�) �
* V �•
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
5�
with the Florida Energy Cod
OD,�,��
`
OWNER/AGENT: �-
BUILDING OFFICIAL:
DATE: I -
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FILE COS`
11/9/2020 10:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 18 Block 5 Waterstone 16 Bedrooms: 4
User Conditioned Area: 1635
Total Stories: 1
1 Worst Case: No
ADAM HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Lot Information
Lot # 18
Block/Subdivision: Waterstone
PlatBook:
Street: 5369 San Benedetto PI
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL, 34951
CLIMATE
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST_LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70
75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1635 15859.5
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1635 15859.5 Yes 5
4
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 158.9 ft 0
1635 ftz
---- 0.29 0 0.71
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Rad
Barr
Solar SA Emitt Emitt Deck Pitch
Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1829 ftZ 410 ftZ Medium
N
0.85 N 0.85 No 0 26.6
ATTIC
/
v #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 300 1635 ft2
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type
Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 30 Blown
1635 ftZ 0.11 Wood
11/9/2020 10:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST RFPnRT
WALLS
# nrnt
Adjacent Space
To Wall Type
Cavity Width Height
R-Vallle Ft In Et In
Arp;;
Sheathing Framing Solar Below
1 E
Exterior Concrete Block - Int Insul Main
4.1 43 1 8
11
384.2 ft2
0
0 0.6
0
2 N
Exterior Concrete Block - Int Insul Main
4.1 17 1 10
8
182.2 ft2
0
0 0.6
0
3 W
Exterior Concrete Block - Int Insul Main
4.1 45 5 10
8
484.4 ft2
0
0 0.6
0
4 S
Exterior Concrete Block - Int Insul Main
4.1 32 8 10
8
348.4 ft2
0
0 0.6
0
5 -
Garage Frame - Wood Main
13 16 4 10
8
174.2 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N Insulated Main
None
.25
3
6 9
20.3 ft2
2
- Wood Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
E
1 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
2
N
2 Vinyl Low-E Double Yes
0.33 0.31 N
5.0 ft2
6 ft 9 in
2 ft 6 in
Drapes/blinds
None
3
N
2 Vinyl Low-E Double Yes
0.33 0.21 N
16.2 ft2
1 ft 5 in
0 ft 10 in
Drapes/blinds
None
4
N
2 Vinyl Low-E Double Yes
0.33 0.31 N
13.3 ft2
6 ft 9 in
4 ft 0 in
Drapes/blinds
None
5
W
3 Vinyl Low-E Double Yes
0.33 0.23 N
6.9 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
6
W
3 Vinyl Low-E Double Yes
0.33 0.23 N
64.8 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
7
S
4 Metal Low-E Double Yes
0.55 0.7 N
17.8 ft2
11 ft 4 in
1 ft 0 in
Drapes/blinds
None
8
S
4 Vinyl Low-E Double Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
None
9
S
4 Vinyl Low-E Double Yes
0.33 0.23 N
16.2 ft2
11 ft 4 in
0 ft 10 in
Drapes/blinds
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
400 ft2 400 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA CFM 50 ELA EgLA
ACH
ACH 50
1 Wholehouse
Proposed ACH(50) .000431 1850.3 101.58 191.03
.1615
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
11/9/2020 10:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr 947 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric
None
Garage
0.94 40 gal
62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
---- Supply ----
---- Return ----
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic
6 327 ftz
Main
81.75 ft Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan Feb
HeatinJan Feb
Mar
f X� Mar
f
A r
APr
Ma rjJun Jul
May Jun Jul
rl
AuSep
ri Aug
Se
ri
Oct
Oct
Nov
Nov
HX
Dec
Dec
H
lX
Ventin Jan [ Feb
X Mar
[
A r
Ma Jun Jul
Aug
Se [X]
Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM
78
78
78
78 78 78
78
78 80
80
80
80
PM
80
80
78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM
78
78
78
78 78 78
78
78 78
78
78
78
PM
78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM
66
66
66
66 66 68
68
68 68
68
68
68
PM
68
68
68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ftZ
0 ft
0.3
Main
11/9/2020 10:59 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 4
13. Cooling system: Capacity
28.4
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1635
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.349
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.276
14. Heating system: Capacity
28.2
c) Area
7c. 204.8
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor: (weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1. 13.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a. 30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
d) Multizone cooling credit
d) Radiant barrier installed
11 d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
Label required by Section R303.1.3 of the Florida Building Code, Energy
Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signatures`- -�
Date:
Address of New Home: 5369 San Benedetto Place City/FL Zip: Fort Pierce, FL 34951
11/9/2020 11:00:03 AM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1