Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Building Permit Application/ Correcrted
All APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 10/9/2020 • Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 34982 Phone: (772) 462-1553 Fax: (772) 462-1578 Permit Number: Building Permit Application Commercial Residential X PERMITTYPE:MECHANICAL CHANGE OUT PROPOSED IMPROVEMENT LOCATION: INSIDE/OUTSIDE Address: 120 BEACH AVE Property Tax ID #. 3419-515-0064-000-2 Site Plan Name: Project Name: 120 BEACH AVE Lot No._ Block No. DETAILED DESCRIPTION OF WORK: HVAC FULL SYSTEM CHANGE OUT NO DUCT WORK LIKE FOR LIKE TRANE 4.0 TON 17 SEER 9.5 HSPF 8 KW CONSTRUCTION INFORMATION: Additional work to be performed under this permit —check all that apply: —Mechanical _ Gas Tank _ Gas Piping _ Shutters _ Windows/Doors _ Electric _ Plumbing _ Sprinklers Total Sq. Ft of Construction: Cost of Construction: $ OWNER/LESSEE: OWNER Name ANTHONY & MAURYN TOLENTINO Address: 120 BEACH AVE City: PORT SAINT LUCIE State: Zip Code: 34952 Fax: Phone No. 973-715-2733 E-Mail: MAURYNTOLENTINO@GMAIL.COM Generator Roof Pitch Sq. Ft. of First Floor: Utilities: _ Sewer _ Septic Building Height: Fill in fee simple Title Holder on next page ( if different from the Owner listed above) CONTRACTOR: Name: ROBERT DELLO RUSSO Company: DEL AIR HEATING & A/C Address: 531 CODISCO WAY City: SANFORD State. FL Zip Code: 32771 Fax: 407-333-3853 Phone No 407-333-2665 E-Mail SALESJOBS@DELAIR.COM State or County License CAC032448 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION: DESIGNER/ENGINEER: Name:_ Address: City: Zip: Phone FEE SIMPLE TITLE HOLDER: Name: Address: Citv: Zip: Phone: — Not Applicable State: Not Applicable MORTGAGE COMPANY: Name: Address: City: Zip: Phone: BONDING COMPANY: Name: Address: Citv: Zip: Phonf Not Applicable State: Not Applicable OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated. I certify that no work or installation has commenced prior to the issuance of a permit. St. Lucie County makes no representation that is granting a permit will authori/T19EN ermit holder to build t subject structure which is in conflict with any applicable Home Owners Association rules, bylaws covenants that may trict or prohibit such structure. Please consult with your Home Owners Association and review youror any restrictions ich may apply. Inconsideration of the granting of this requested permit, I do hereby agree thin all respects orm the work in accordance with the approved plans, the Florida Building Codes and St. Luciy Amendm s The following building permit applications are exempt from undergoing a full cency rep w: aom additions, accessory structures, swimming pools, fences, walls, signs, screen rooms and ary us to other non-residential use "WARNING TO OWNER: YOUR FAILURE TO RECORD A NOTICE OF CE T MAY RESULT IN YOUR PAYING TWICE FOR IMPROYEM O YOUR PROPERTY. A NOTICME EMENT MUST BE RECORDED AND POSTED ON THE J I BEFORE THE FIRST INSPE . IFNT D TO OBTAIN FINANCING, CONSULT WITH YOUR L R AN ATTe�Y BEFORg-REC RDING YOUi OF COMMENCEMENT." Sigprature of er/ Lesse ractor as Agent for Owner I SXnature of Contractor/License Holder STATE OF FLORIDA COUNTY OF SG STATE OF FLORADA COUNTY OF YAO The forgoing Instru ent was acknowledged before me The fo going ins ment was ack owledg before me this day of 2Da 1 by this X day of 20 by l0 Q 0 �- Qg -t) Name of person making statement. Name of person making ement. Personally Known OR Produced Identification Perso fly Known OR Produced Identification Type of Identification Ty of Identification Produced Pr dine, J (Signature of Notary Pub ic- State of Florida (Signature of Notary P blic- Sta LADI MAR PAS P+j� �. ILY J BARTLES ;$ ��- Notary Public State Commission No. `+4 �y?, 1 Commission No. -• 4csa �nmission # GG ._ M" CCi ON # GG 162762 = My Commission I r EXPIRES: November 26, 2021 March 11, 20 REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEA TURTLE MANGROVE COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW DATE RECEIVED DATE COMPLETED NA 87 l ,,_ .')DELAIR. ,HEATING AIR CONDMONING Never Any Overtime Charges - Call Today! (888) 831-2665 Customer's Narrie: Job Address: MAURYN TOLENTINO 120 BEACH AVE, #7369029 10/07/2020 PORT SAINT LUCIE, FL 34952-1303 Customers Qillir ig Address: City, state, Zip: Custo!nar ,i: 120 BEACH AVE, #15445566 PORT SAINT LUCIE, FL 34952-1303 11267304 Horne Phoi e: Mobile t.. Ennail(s): Job x' (973)715-2733 mauryntolentino@gmaii.com 3284481 Serving Florida Since 1983 100% Employee Owned. As an employee owned company, each and every employee is an owner and is committed to providing a quality service in a timely manner, treating your home as if it were ours. Financing Available. Del -Air Heating and Air Conditioning offers attractive and affordable financing options. C ,. Trane XR17 4TWR7048A1000D Heat Pump 4 Tons 17 SEER, 9.5 HSPF 10 Year Parts Warranty 1 Year Labor Warranty 10 Year Compressor Warranty Trane M-Series TEM6AOC48H41 SB Air Handler 10 Year Parts Warranty 1 Year Labor Warranty BAYHTR1508BRKC Electric Heater 8 kW AHRI # 8875433 Notes (BAYSF1235AAA) in Accessories AHRI System (47500 BTU) Required Thermostat - Trane Nexia XL624 Control (TCONT624AS42DA) Option 2 • ALL Major Brands. Del -Air sells and services ALL major brands to help customers find the best solutions for their unique air conditioning and heating needs. • Expertly Trained Technicians. Our professional, nationally certified and factory trained technicians have years of installation and service experience to get the job done right the first time. Trane XL18i 4TWX8048A1000D Heat Pump 4 Tons 17 SEER, 9.5 HSPF 10 Year Parts Warranty 2 Year Labor Warranty 12 Year Compressor Warranty Trane M-Series TEM6AOC48H41 SB Air Handler 10 Year Parts Warranty 1 Year Labor Warranty BAYHTR1508BRKC Electric Heater . 8kW AHRI # 8875432 Notes (BAYSF1235AAA) in Accessories AHRI System (48500 BTU) Accessories Required Thermostat - Trane Nexia XL624 Control (TCONT624AS42DA) 1117 D - N b October 7, 2020 11:39:34 AM Page 1 of 4 • Required Drain Line - Reuse Existing Drain Line -Clean With Drain Line Cleaner • Required Indoor Unit - Full Platform - Rebuild Platform with 1-1/2" Antimicrobial Insulation & 3/4" Plywood New Top • Required Outdoor Unit - Condenser Easy One Man Access • Required Permits - All Necessary Permits are Included • Existing Outdoor Breaker Brand - Existing Outdoor Unit Breaker Brand GE • Outdoor Breaker Existing Size - Existing 50 Amp Outdoor Breaker • Existing Indoor Breaker Brand - Existing Indoor Unit Breaker Brand GE • Existing Indoor Breaker Size - Existing 50 Amp Indoor Breaker • Included Material - Included - Clean Work Area At Job Completion • Included Material - Included - Dispose Of Old Equipment • Included Material - Included - New Code Approved Hurricane Straps • Included Material - Included - New In - Line Safety Float Switch • Duct Work - Return Grill - No Duct - With Filter - Max (30 X 18) with equipment • Outdoor Unit - New Hurricane Rated Condenser Pad 40 X 40 (H022745) Total: $7,178 Estimated Payment: $0.00 Payment: Cash Remaining Baiance Pa Additional Services • Required Drain Line - Reuse Existing Drain Line Clean With Drain Line Cleaner • Required Indoor Unit - Full Platform - Rebuild Platform with 1-1/2" Antimicrobial Insulation & 3/4" Plywood New Top • Required Outdoor Unit - Condenser Easy One Man Access • Required Permits - All Necessary Permits are Included • Existing Outdoor Breaker Brand - Existing Outdoor Unit Breaker Brand GE • Outdoor Breaker Existing Size - Existing 50 Amp Outdoor Breaker • Existing Indoor Breaker Brand - Existing Indoor Unit Breaker Brand GE • Existing Indoor Breaker Size - Existing 50 Amp Indoor Breaker • Included Material - Included - Clean Work Area At Job Completion • Included Material - Included - Dispose Of Old Equipment • Included Material - Included - New Code Approved Hurricane Straps • Included Material - Included - New In - Line Safety Float Switch • Duct Work - Return Grill - No Duct - With Fitter - Max (30 X 18) with equipment • Outdoor Unit - New Hurricane Rated Condenser Pad 40 X 40 (H022745) Option 2 Total Investment Total: $9,793 Estimated Payment: $0.00 Payment: Cash Total Investment (Before Discount) $8,693 Less Del Air Discount (-) $1,515 Less Down Payment (-) $0 Remaining Balance $7,178 Option 1: Estimated payment of $0.00 Cash (approval required). Customer Acceptance: Date: 441 Company Approval: Date: 10/08/2020 3:22 PM Company Representative: Jeremy Sadoff, jsadoff@delair.com, (407) 405-5336 October 7, 2020 11:39:34 AM Page 2 of 4 Notes Del- Air will register the Extended Manufacturers Parts Warranty 10 year compressor and coil and 1 year labor is not transferable. It is only good to the original owner Trane will transfer warranty if within 90 days from the sale of the home Homeowner is responsible to stay home (1) full day for the Building Department Inspection All applicable sales and local taxes are included. Proposal valid 30 Days: All necessary materials and supplies to complete installation are included. Operational ductwork, venting, electrical wiring and drains are used as needed. Used (replaced) equipment is removed and recycled as appropriate. Used refrigerant is reclaimed and recycled in accordance with EPA Standards. Work area is cleaned upon completion. Proper operation is explained to you. Installations include: New code approved hurricane straps New pan safety float switch Terms & Conditions All terms and conditions herein apply to HVAC installation and service, in addition to plumbing installation and service, except to the extent otherwise noted in the Notes section. Replacement Purchase Terms & Conditions Notes, General • Del -Air: o will register the Extended Manufacturer's Equipment Warranty, extending from 5 to 10 years from Installation Date • will remove the existing (replaced) equipment and recycle as appropriate o will reclaim and recycle used refrigerant in accordance with EPA Standards o provides one-year labor warranty from date of installation (can be extended to two at time of sale) • Homeowner may be required to be home for one day within the 6 months after installation for inspection, unless virtual inspection is available in municipality • All applicable sales and local taxes are included • Proposal valid 30 Days • All necessary materials and supplies to complete installation are included • Existing, operational ductwork, venting, electrical wiring and drains are used as needed • If Equipment is high efficiency, the installation is compliant with Del-Air's Retail Guidelines for High Efficiency Communicating Retrofit Applications (comfort advisor initials) All sales to Customer are subject to these terms and conditions ("Terms") which are binding on the parties, their successors and assigns, and there are no terms, conditions, understandings, or agreements other than those stated herein. 1. Payment Terms: The entire invoice is due upon installation of the Equipment. Any payment not received within five (5) days from installation is subject to interest at the rate of ten (10%) percent per annum, calculated from the date of installation. If Customer's check does not clear, credit card is declined, or payment does not go through, Customer shall be liable for the amount due, plus any late fees and collections fees, including fees and expenses of legal counsel retained by Del -Air. 2. t+lWarranf es, Limitatlons on WarranfLos No Lialsifity DEL -AIR PROVIDES A ONE (1) YEAR LABOR WARRANTY ON THE WORK PERFORMED. THIS WARRANTY IS VOID IF ANY WARRANTY ISSUES ARE NOT INSPECTED AND APPROVED IN ADVANCE BY DEL - AIR BEFORE ANY REPAIR IS MADE, OR IF THERE ARE ANY ALTERATIONS TO THE SYSTEM OR REPAIRS MADE BY ANYONE OTHER THAN DEL -AIR. DEL -AIR DISCLAIMS ALL OTHER WARRANTIES (EXCEPT TITLE), EXPRESS OR IMPLIED, AND DEL -AIR DOES NOT AUTHORIZE ANY THIRD PERSON OR PARTY TO ASSUME ANY WARRANTY OBLIGATION OR LIABILITY ON ITS BEHALF. THIS WARRANTY SPECIFICALLY EXCLUDES COVERAGE FOR: (a) NORMAL WEAR AND TEAR, (b) PERFORMANCE, FUNCTIONALITY, OR COMPATIBILITY OF EXISTING EQUIPMENT, LINE SET(S), DUCTWORK, THERMOSTATS, CONTROLS, OR OTHER EQUIPMENT/MATERIALS THAT ARE NOT REPLACED AS PART OF THE NEW EQUIPMENT INSTALLATION HEREUNDER, (c) ANY DAMAGE ARISING OUT OF NEGLECT, MISUSE, ABUSE, FAILURE TO REPLACE AIR FILTERS, CLEAN DRAIN LINE OR USE PROPER SUPPLIES, PARTS OR MATERIALS IN THE OPERATION OF THE EQUIPMENT, (d) ANY SYSTEM THAT HAS BEEN TAMPERED WITH, ALTERED IN ANY WAY, OR WHICH HAS SERIAL NUMBERS ALTERED, DEFACED OR REMOVED, AND (e) ANY TEMPERATURE GUARANTEE BEYOND AMERICAN REFRIGERATION INSTITUTE (ARI) STANDARDS. THE ONLY WARRANTIES APPLICABLE TO THE EQUIPMENT AND MATERIALS INSTALLED ARE THOSE, IF ANY, EXTENDED BY THE RESPECTIVE MANUFACTURER TO CUSTOMER AND REFLECTED IN THE APPLICABLE WARRANTY DOCUMENTS. DEL -AIR HEREBY ASSIGNS TO CUSTOMER, WITHOUT RECOURSE, ANY APPLICABLE WARRANTIES EXTENDED BY THE MANUFACTURER TO DEL -AIR. SUCH ASSIGNMENT SHALL CONSTITUTE DEL-AIR'S SOLE OBLIGATION AND CUSTOMER'S EXCLUSIVE REMEDY AGAINST DEL -AIR WITH REGARD TO DEFECTIVE MATERIALS AND/OR EQUIPMENT INSTALLED. THERE IS NO WARRANTY ON USED EQUIPMENT, UNITS AND PARTS SOLD BY DEL -AIR, IF ANY. October 7, 2020 11:39:34 AM Page 3 of 4 IN NO EVENT SHALL DEL -AIR BE LIABLE FOR ANY LOSSES, COSTS, DAMAGES OR LIABILITIES WHATSOEVER (EXCEPT AS EXPRESSLY PROVIDED IN THESE TERMS), INCLUDING WITHOUT LIMITATION ANY (A) DIRECT, INDIRECT, INCIDENTAL, EXEMPLARY, PUNITIVE, SPECIAL, OR CONSEQUENTIAL DAMAGES, (B) DAMAGES RESULTING FROM LOSS OF TIME, LOSS OF USE OR INCONVENIENCE, EVEN IF DEL -AIR HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES, (C) DAMAGES CAUSED BY OVER -SIZING (INCLUDING WITHOUT LIMITATION SHORT CYCLING, HUMIDITY CONTROL, AND MOLD GROWTH) OR UNDER -SIZING (INCLUDING WITHOUT LIMITATION INABILITY TO HEAT OR COOL WITHIN THE MANUAL J. STANDARD DESIGN TEMPERATURES), (D) DAMAGES CAUSED BY HIGH HUMIDITY LEVELS, OLD OR WORN DUCTWORK THAT WAS NOT REPLACED AS PART OF THE INSTALLATION OF NEW EQUIPMENT HEREUNDER, OR DUCTWORK SWEATING AND/OR PRODUCING CONDENSATE DUE TO HOME INFILTRATION RATES, IMPROPER ENVELOPE CONSTRUCTION OR ANY OTHER REASON, or (e) ANY FAILURE IN OPERATION OR PERFORMANCE WHICH MAY RESULT FROM THE CONNECTION TO OR OPERATION OF INSTALLED EQUIPMENT IN CONJUNCTION WITH ANY OTHER EQUIPMENT FURNISHED BY CUSTOMER AT THE TIME OF ORIGINAL INSTALLATION OR ADDED SUBSEQUENT THERETO. CUSTOMER SHALL TAKE ALL REASONABLE MEASURES TO PRESERVE AND PROTECT THE EQUIPMENT FROM DETERIORATION OTHER THAN NORMAL WEAR AND TEAR, SHALL PROPERLY MAINTAIN THE SYSTEM, INCLUDING REPLACING AIR FILTERS AS REQUIRED AND CLEANING DRAIN LINE, AND SHALL USE THE EQUIPMENT IN THE ORDINARY COURSE, WITHIN ITS NORMAL CAPACITY, WITHOUT ABUSE, AND IN A MANNER CONTEMPLATED BY THE MANUFACTURER. 3. Goveming Law: The work performed, these Terms, and the business relationship between Customer and Del -Air shall be governed by and construed in accordance with the laws of Florida without regard to conflicts of laws rules. The parties agree that any legal action arising under or related to the work performed and these Terms shall be brought in Seminole County, Florida, and any right to object to such venue or to assert the inconvenience of such forum is hereby waived. 4. Title; Risk of Lvss:Title of the Equipment and related products and materials covered by these Terms remains solely in Del -Air until the entire purchase price has been paid in full. Risk of loss shall pass to the Customer upon installation of equipment at Customer's property. Del -Air shall not be responsible for any loss due to fire, theft, vandalism, and/or malicious mischief once the Equipment has been installed. 5. FLORIDA'S LIEN LAW. ACCORDING TO FLORIDA'S CONSTRUCTION LIEN LAW (SECTIONS 713.001 — 713.37, FLORIDA STATUTES), THOSE WHO WORK ON YOUR PROPERTY OR PROVIDE MATERIALS AND ARE NOT PAID IN FULL HAVE THE RIGHT TO ENFORCE THEIR CLAIM FOR PAYMENT AGAINST YOUR PROPERTY. IF YOUR CONTRACTOR OR A SUBCONTRACTOR FAILS TO PAY SUBCONTRACTORS, SUB -SUBCONTRACTORS, OR MATERIAL SUPPLIERS, THE PEOPLE WHO ARE OWED MONEY MAY LOOK TO YOUR PROPERTY FOR PAYMENT, EVEN IF YOU ALREADY PAID YOUR CONTRACTOR IN FULL. IF YOU FAILTO PAY YOUR CONTRACTOR, YOUR CONTRACTOR MAY ALSO HAVE A LIEN ON YOUR PROPERTY. THIS MEANS IF A LIEN IS FILED, YOUR PROPERTY COULD BE SOLD AGAINST YOUR WILL TO PAY FOR LABOR, MATERIALS, OR OTHER SERVICES THAT YOUR CONTRACTOR OR A SUBCONTRACTOR MAY HAVE FAILED TO PAY. TO PROTECT YOURSELF, YOU SHOULD STIPULATE IN THIS CONTRACT THAT BEFORE ANY PAYMENT IS MADE, YOUR CONTRACTOR IS REQUIRED TO PROVIDE YOU WITH A WRITTEN RELEASE OF LIEN FROM ANY PERSON OR COMPANY THAT HAS PROVIDED TO YOU A "NOTICE TO OWNER." FLORIDA'S CONSTRUCTION LIEN LAW IS COMPLEX, AND IT IS RECOMMENDED THAT YOU CONSULT AN ATTORNEY. 6. FLORIDA HOMEOWNER'S CONSTRUCTION RECOVERY FUND PAYMENT, UP TO A LIMITED AMOUNT, MAY BE AVAILABLE FROM THE FLORIDA HOMEOWNERS' CONSTRUCTION RECOVERY FUND IF YOU LOSE MONEY ON A PROJECT PERFORMED UNDER CONTRACT, WHERE THE LOSS RESULTS FROM SPECIFIED VIOLATIONS OF FLORIDA LAW BY A LICENSED CONTRACTOR. FOR INFORMATION ABOUT THE RECOVERY FUND AND FILING A CLAIM, CONTACT THE FLORIDA CONSTRUCTION INDUSTRY LICENSING BOARD AT THE FOLLOWING TELEPHONE NUMBER AND ADDRESS: Construction Industry Licensing Board 2601 Blairstone Road Tallahassee, Florida 32399-1039 (850)487-1395 HVAC License: CAC032448 Plumbing License: CFC1430606 October 7, 2020 11:39:34 AM Page 4 of 4 \ / � 2 / CN _ __a £ f�\/\\ / c )>a o Q \ /41 )\\ L z /} /ƒ/ \/ \ d ]ƒ$ {2 k: JJ- \/\ d / ) k f( k CL £ COa'CL 2 f§# ƒ o in E > m2 / / }f u i // z } . 2 « t §\3 / a) \ \�t7{(D /{ k\ CC r; = e O//*\ 3 2 2 w <cu » ® j ®w1 < -. \ { ) / J 0 < This combination qualifies for a Federal Energy Efficiency Tax Credit when o placed in service between 1/1/2015 and 12/31/2020. anal CERTIFIED Certificate of Product Ratings AHRI Certified Reference Number: 8875433 T Date : 10-08-2020 Model Status :Active AHRI Type : HRCU-A-CB (Split System: Heat Pump with Remote Outdoor Unit -Air -Source) Series. XR17 Outdoor Unit Brand Name: TRANE Outdoor Unit Model Number (Condenser or Single Package) : 4TWR7048A1 Indoor Unit Model Number (Evaporator and/or Air Handler) : TEM6AOC48H41+TDR+UF/HRZ The manufacturer of this TRANE product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI 210/240 with Addendum 1, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (A2) - Single or High Stage (95F), btuh : 48500 SEER: 17.00 EER (A2) - Single or High Stage (95F) : 13.00 Heating Capacity (H12) - Single or High Stage (47F) : 47000 HSPF (Region IV) : 9.50 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being prod uced."production Stopped" Model Stales are those that an AHRI Certification Program participant is no lAnger producing re b is still selling a cbut are for sale. Ratin s that are agcnm Hied h w ind'cate an involunla i re -rate_ ThF new ubilshed rpfinq Is shown aloe ith the revlous i.e. WA 5 adn . DISCLAIMER AHRI does not endorse the Product(s) listed on this Certificate and makes no representations. warranties or guarantees as to. and assumes no responsibility for, the product(si listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out ai the use or performance of the praduibilit or the unauthorized alteration re data listed on this Certificate. Certified ratings are valid only for models and singgur Of Ih listed in the directory unauthorized d 21tc t i idiredto ata listed rg�to TERMS AND CONDITIONS This Certificate and contents are oprietaryproducts oFAHRI. This Certificate shalt only he used for individual, personal and conNdentlal referencea c Purposes, The contents of this Certificate may not. In whole 'Or in part, he repro du cud: copied; disseminated; entered into a computer database; or otherwise utilized, In any form Or manner or by any means, except for the user's individual. Or IL, persona; and confidential reference. CERTIFICATE VERIFICATION AIR.CONWTIOIJING, HEATING, The information forthe model cited on this certificate can be verified at www.ahridirectory.org, click on 'Verity Certltleate' link & REFRIGERATION INSTITUTE and enter the AHRI Certified Reference Number and the date on which the certificate was issued, which is listed above, and the Certificate No., which is Ilsted at bottom right. °rc mike Ei!'s hcrter^ ©2020Air-Conditioning, Heating, and Refrigeration Institute ~ CERTIFICATE NO.: 132466585717997567