HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: Lot 12 Block 5 Waterstone 1780 AGL
Builder Name: ADAMS HOMES
Street: 5345 San Benedetto Place
Permit Office:
City, State, Zip: Fort Pierce , FL , 34951
Permit Number:
Owner:
Jurisdiction: 661000
Design Location: FL, ST_LUCIE_CO_INTL
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1512.6 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1244.60 ftz
b. Frame - Wood, Adjacent
R=13.0 268.00 ftz
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 3
d. N/A
R= ftz
5. Is this a worst case? No
10. Ceiling Types (1897.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1780.00 ftz
6. Conditioned floor area above grade (ftz) 1780
b. Knee Wall (Vented)
R=19.0 117.00 ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
11. Ducts
R ftz
7. Windows(177.0 sgft.) Description Area
a. Sup: Attic, Ret: Main, AH: Main
6' 356
a. U-Factor: Dbl, U=0.33 113.31 ftz
SHGC: SHGC=0.23
b. U-Factor: Dbl, U=0.33 45.94 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
28.4 SEER:15.00
c. U-Factor: Dbl, U=0.55 17.78 ftz
SHGC: SHGC=0.70
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Heat Pump
28.2 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.639 ft.
Area Weighted Average SHGC: 0.272
14. Hot water systems
8. Floor Types (1780.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. a. Slab -On -Grade Edge Insulation R=0.0 1780.00 ftz
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.099 Total Proposed Modified Loads: 56.81
PASS
Total Baseline Loads: 56.56
I hereby certify that the plan cifications cove
Revi of the plans and
'Si s S7.4i'
this calculation are in corn nergy
specifications covered by this
o
Code.
calculation indicates compliance
with the Florida Energy Code.
ti tri, �: '=;; ;;;��;O
PREPARED BY:
Before construction is completed
r Y
DATE: 1 n-28-2090 Winn KPnmany
this building will be inspected for
O
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florid nergy Code.
G'OD y1
OWNER/AGE
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
FIDE COPY
10/28/2020 11:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST RFPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
Lot 12 Block 5 Waterstone 17 Bedrooms: 3
User Conditioned Area: 1780
Total Stories: 1
1 Worst Case: No
ADAMS HOMES Rotate Angle: 0
Cross Ventilation: No
661000 Whole House Fan: No
Single-family
New (From Plans)
Address Type: Lot Information
Lot # 12
Block/Subdivision: Waterstone
PlatBook:
Street: 5345 San Benedetto PI
County: St. Lucie
City, State, Zip: Fort Pierce ,
FL , 34951
CLIMATE
/
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 39 90
70 75 299 58 Medium
BLOCKS
Number
Name
Area Volume
1
Block1
1780 15664
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
1780 15664 Yes 4
3 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 155.7 ft 0
1780 ft2 ---- 0.38 0 0.62
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Rad Solar SA Emitt Emitt Deck Pitch
Barr Absor. Tested Tested Insul. (deg)
1
Gable or Shed Composition shingles 1991 ft' 446 ftz Medium
N 0.85 N 0.85 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 300 1780 ftz N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
2
Knee Wall (Vented)
Under Attic (Vented)
Main 19 Batt
Main 30 Blown
117 ftz 0.11 Wood
1780 ftZ 0.11 Wood
10/28/2020 11:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY rWFrKI IST RF'anRT
WALLS
Adjacent
Space
Cavity Width
R-\/,qllle Et In Et
Height
In
Area
Sheathing Framing Solar Below
1
SE
Exterior Concrete Block - Int Insul
Main
4.1 40 0 8
0
320.0 ft2
0
0 0.6
0
2
NE
Exterior Concrete Block - Int Insul
Main
4.1 40 6 8
0
324.0 ft2
0
0 0.6
0
3
N
Exterior Concrete Block - Int Insul
Main
4.1 3 0 9
6
28.5 ft2
0
0 0.6
0
4
NW
Exterior Concrete Block - Int Insul
Main
4.1 11 9 9
6
111.6 ft2
0
0 0.6
0
5
W
Exterior Concrete Block - Int Insul
Main
4.1 3 0 9
6
28.5 ft2
0
0 0.6
0
6
SW
Exterior Concrete Block - Int Insul
Main
4.1 54 0 8
0
432.0 ft2
0
0 0.6
0
7
-
Garage Frame - Wood
Main
13 33 6 8
0
268.0 ft2
0
0.23 0.01
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
NW Insulated Main
None
.25
3
6 8
20 ft2
2
- Wood Main
None
.25
2
8
6 8
17.8 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
Overhang
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Int Shade
Screening
1
SE 1 Vinyl Low-E Double
Yes
0.55 0.7 N
17.8 ft2
14 ft 4 in 0 ft 10 in
None
None
2
SE 1 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
3
NE 2 Vinyl Low-E Double
Yes
0.33 0.23 N
32.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
4
N 3 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
5
NW 4 Vinyl Low-E Double
Yes
0.33 0.21 N
23.2 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
6
W 5 Vinyl Low-E Double
Yes
0.33 0.21 N
11.4 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
7
SW 6 Vinyl Low-E Double
Yes
0.33 0.23 N
48.6 ft2
1 ft 4 in
0 ft 10 in
Drapes/blinds
Exterior 5
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
391 ft2 391 ft2
64 ft
8 ft
1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA Egl-A
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000391
1827.5 100.33 188.68
.1409
7
HEATING SYSTEM
#
System Type Subtype
Speed Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/ Split
Singl HSPF:8.5
28.2 kBtu/hr
1
sys#1
10/28/2020 11:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 4
FORM R405-2017 INPHT SUMMARY rI-IFrK1 IGT QIFanQT
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 28.4 kBtu/hr 947 cfm
0.75
1
sys#1
HOT WATER SYSTEM
# System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1 Electric None
Garage
0.94 40 gal 62.3 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cert # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ftz
DUCTS
/ ---- Supply ----
---- Return ----
Air
CFM 25 CFM25
HVAC #
# Location R-Value Area
Location
Area Leakage Type
Handler
TOT OUT
QN
RLF
Heat Cool
1 Attic 6 356 ftZ
Main
89 ftZ Default Leakage
Main
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
CoolingJan j Feb j Mar
Heatinf X Jan f X] Feb f X] Mar
f
A r
APr f
Jul
MaY f Jun Jul
Ma X Jun rl
Au
AuSep
ri
Se
rl
Oct
Oct
Nov
Nov
Dec
DecVentin
[ Jan [ ] Feb X Mar
[
A r [
Ma [ Jun Jul
Aug
Se [X]
Oct
X Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2
3
4 5 6
7
8 9
10
11
12
Cooling (WD) AM 78
78
78
78 78 78
78
78 80
80
80
80
PM 80
80
78
78 78 78
78
78 78
78
78
78
Cooling (WEH) AM 78
78
78
78 78 78
78
78 78
78
78
78
PM 78
78
78
78 78 78
78
78 78
78
78
78
Heating (WD) AM 66
66
66
66 66 68
68
68 68
68
68
68
PM 68
68
68
68 68 68
68
68 68
68
66
66
Heating (WEH) AM 66
66
66
66 66 68
68
68 68
68
68
68
PM 68
68
68
68 68 68
68
68 68
68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction Space
Default 8 Ibs/s .ft.
0 ftz
0 ft
0.3
Main
10/28/2020 11:36 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017). Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE- LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 100
The lower the Energy Performance Index, the more efficient the home
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple family
2. Single family
b) Return ducts R
6.0
c) AHU location
Main
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity
28.4
a) Split system SEER
15.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 1780
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.352
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.272
14. Heating system: Capacity
28.2
c) Area
7c. 177.0
a) Split system heat pump HSPF
8.5
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-facto r: (weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2. 4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131. 13.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11 a. 30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c. 19.0
d) Multizone cooling credit
d) Radiant barrier installed
11 d. No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Sign
Date:
Address of New Home: 5345 San Benedetto Place City/FL Zip: Fort Pierce, FL 34951
10/28/2020 11:36:19 AM EnergyGaugeO USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1