In-Place Density Test Report
Client:D.R. HORTON, INC. EAST FLORIDA DIVISION UES Technician:Johnnie Smith
1430 Culver Drive, NE
Palm Bay, FL 32907
Date Tested:01/12/2021
Project:CMT CREEKSIDE
Various Locations,Vero Beach, County, FL 32967
Type of Test:
Area Tested:3213 Trinity, Lot 69, Foundation Pad Field:ASTM D-6938 Nuclear Gauge Method
Material:Fill Laboratory:ASTM D1557 Modified Proctor
Reference Datum:0 = Top of Final Grade
The tests below meet the 95% minimum compaction requirement.
Test
No.Location of Test Range
Maximum
Density
(pcf)
Optimum
Moisture
(%)
Field Dry
Density
(pcf)
Field
Moisture
(%)
Soil
Compaction
(%)
Pass
or
Fail
1 W section 1-2 ft 118.6 10.8 118.2 10.7 100 Pass
2 E section 1-2 ft 118.6 10.8 118.4 10.6 100 Pass
3 Center section 1-2 ft 118.6 10.8 118.7 10.9 100 Pass
Remarks:0-1’ HCP=50+, > 95 % Compaction, PASS. HCP tests are empirically correlated to the relative density of the soil.