Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
EnergyGauge Summit@ v6.10 INPUT DATA. REPORT Project Information Project Name: 7369 COMM orientation: 0 Deg Clockwise. Walls & Windows ill be rotated accordingly Project Title: 7369 COPMMERCIAL CIRCLE Building Type: Office Address: 7369 COPMMERCIAL CIRCLE Building Classification: New Finished building State: F'L No.of Stories: l Zip: 0 GrossArea: 448 SF Owner: Zones No Acronym Description Type Area [sfl Multiplier Total Area [sf) 1 PrOZoI Zone 1 CONDIT101,MD 448.0 1 448.0 ❑ Spaces No Acronym Description Type Depth [ft] Width Height IN [ft] Multi Total Area plier [sfJ Total Volume [cfJ 7/2/2020 GnergyGauge Summit@ v6.10 1 In Zone: Pr0Zol ' 1 PrOZo1Sp1 ZoOSp1 Office - Enclosed 32.00 14.00 10.00 1 448.0 4480.0 ❑ Lighting No Type Category No. of Watts per Power Control Type No.of Luminaires Luminaire [W] Ctrl pts In Zone: Pr0Zo1 In Space: PrOZolSpl I Compact Fluorescent General Lighting 4 60 240 Manual On/Off 2 ❑ WaHs (Walls will be rotated clockwise by building rotation value) No Description Type Width H (Effec) Multi Area Orientation Conductance Heat Dens. R-Value [ft] [ft] plier [sf[ [Btu/fir. sf. F] Capacity [Ib/cf] [h.sf.FBtu] [Btu/sf.F] In Zone: PrOZol i PrOZolWal 5/8" stucco 36.0 10.0 1 360.0 North 0.2067 5.731 34.65 4.8 ❑ /8"CMU/3/4"ISO ' BTWN24"oc/.5" Gyp 2 PrOZo 1 Wa2 0.75 in. stucco, 14.0 10.0 1 140.0 East 0.1118 1.183 14.94 8.9 ❑ 2x4x 16" oc, RI lBatt, 0.5 in. gyp 3 PrOZO Wa3 0.75 in. stucco, 36.0 10.0 1 360.0 South 0.1118 1.183 14.94 8.9 ❑ 2x4x 16" oc, RI IBatt, 0.5 in. gyp 4 PrUol Wa4 0.75 in. stucco, 14.0 10.0 1 140.0 West 0.1118 1.183 14.94 8.9 ❑ 2x4xl6" oc, R11 Batt, 0.5 in. gyp Windows (Windows will be rotated clockwise by building rotation value) No Description Orientation Shaded U SHGC Vis.Tra W H (Fffec) Multi Total Area [Btu/hr sf F[ IN [ft] plier [Sf] 7/2/2020 FnergyGauge Summit© v6.10 In Zone: PrOZol In Wall: PrOZolWal 1 PrOZoI Wal Wi 1 North No 1.2500 0.8 0.8 3.0 6.6 2 39.6 Doors No Description Type Shaded? Width H (Effec) Multi Area Cond. Dens. Heat Cap. R-Value ]ft] [ft] plier [sfJ [Btu/hr. A. F] [lb/cf] [Btu/sf. F] [h.sf.F/Btu] In Zone: PrOZol In Wall: PrOZo1Wa3 1 PrOZo1Wa3Drl Solidcore.flush No 3.00 6.60 2 19.8 0.3504 0.00 0.00 2.85 ❑ (2.25) Roofs No Description Type Width H (Effec) Multi Area Tilt Cond. Heat Cap Dens. R-Value IN IN plier [sfJ [deg] [Btu/lir. Sf. F] [Btu/sf. F] [Ib/cf] [h.sf.FBtu] In Zone: PrOZol i PrOZo 1Rfl Mtl Bldg Roof/R-19 , 36.00 14.00 1 504.0 0.00 0.0492 1.34 9.49 20.3 ❑ Batt Skylghts No Description Type U SHGC Vis.Trans W H (Effcc) Multiplier Area Total Area [Btu/hr A F] IN IN [Sf] ]Sf] In Zone: In Roof: El Floors No Description Type Width H (Effec) Multi Area Cond. Heat Cap. Dens. R-Value IN [ft] plier [sfl [Btu/hr. A. F[ [Btu/sC F] [Ib/cf[ [h.sf.F/Btu] 7/2/2020 EnergyGauge Summit@O v6.10 In Zone: PrOZol 1 PrOZo1Fl I 1 ft. soil, concrete 36.00 14.00 1 504.0 0.2681 34.00 113.33 3.73 0 floor, carpet and rubber pad Systems PrOSyl System 1 Constant Volume Air Cooled Split No. Of Units 1 System < 65000 Btu/hr Component Category Capacity Efficiency IPLV l Cooling System 29000.00 16.00 8.00 2 Heating System 15500.00 1.00 ❑ 3 Air Handling System -Supply 1000.00 0.80 Plant Equipment Category Size Inst.No Eff. IPLV Water Heaters W-Heater Description Capacit}Cap.Unit Im Rt. Efficiency Loss E-Lighting Description Category No. of Watts per Area/Len/No. of units Control Type Wattage Luminaires Luminaire [sf/ft/No] [w] 7/2/2020 EnergyGauge Summit@ v6.10 4 Piping No Type Operating Insulation Nomonal pipe Insulation Is Runout? Temperature Conductivity Diameter Thickness [F] [ Btu-in/h.sf.F] [in] [in] Fenestration Used Name Glass Type No. of Glass SHGC VLT Panes Conductance [Btu/h.sf.F] ASHULSgiCIrAl1 User Defined 1 1.2500 0.8200 0.7600 ❑ Frm Mat No Acronym Description 197 at BOARD,1/21N 178 Matl178 CARPET W/RUBBER PAD 265 Mat1265 Soil, 1 ft 48 Mat148 6 in. Heavyweight concrete 267 Mat1267 0.75" stucco 266 Matl266 2x4@16" oc + RI I Batt 268 Mat1268 0.625" stucco 42 Mat142 8 in. Lightweight concrete block 269 Mat1269 .75" ISO BTWN24" oc 23 Matl23 6 in. Insulation Materials Used Only R-Value RValue Thickness Conductivity. Density SpecificHeat Used [h.sf.F/Btu] IN [Btu/h.ft.F] [Ib/cfj [Btu/lb.F] o. Yes 1.2300 ❑ No 2.0000 1.0000 0.5000 100.0 0.2000 ❑ No 0.5000 0.5000 1.0000 140.0 0.2000 ❑ No 0.1563 0.0625 0.4000 16.0 0.2000 ❑ No 8.3343 0.2917 0.0350 9.7 0.2000 ❑ No 0.1302 0.0521 0.4000 16.0 0.2000 0 No 2.0212 0.6670 0.3300 38.0 0.2000 ❑ No 2.2321 0.0625 0.0280 4.2 0.3000 ❑ No 20.0000 0.5000 0.0250 5.7 0.2000 ❑ 7/2/2020 lnergyGauge Summit® v6.10 5 279 Matl279 Solid come flush (2.25") Yes 2.8537 ❑ 94 Matl94 BUILT-UP ROOFING, 3/8IN No 0.3366 0.0313 0.0930 70.0 0.3500 ❑ Constructs Used Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct [Btu/h.sf.Fj [Btu/sLF] [lb/cf] [h.sfF/Btu] 1009 0.75 in. stucco, 2x4xl6" oc, RI IBatt, 0.5 in. No No 0.11 1.18 14.94 8.9 ❑ gyp Layer Material Material Thickness Framing No. [ft] Factor 1 267 0.75" stucco 0.0625 0.000 ❑ 2 266 2x4@16" oc + RI 1 Batt 0.2917 0.000 ❑ 3 187 GYP OR PLAS BOARD,1/21N 0.0417 0.000 ❑ Simple Massless Conductance Heat Capacity Density RValue No Name Construct Construct Btu/h.sLF [ ] Btu/sf.F ( ] lb/c [ f] [h.sfFBtuJ 1011 5/8" stucco /8"CMU/3/4"ISO No No 0.21 5.73 34.65 4.8 ❑ BTWN24"oc/.5" Gyp Layer Material Material Thickness Framing No. [ft] Factor 1 268 0.625" stucco 0.0521 0.000 ❑ 2 42 8 in. Lightweight concrete block 0.6670 0.000 ❑ 3 269 .75" ISO BTWN24" oc 0.0625 0.000 ❑ 4 187 GYP OR PLAS BOARD, WIN 0.0417 0.000 ❑ 7/2/2020 EnergyCauge Summit® v6.10 No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.FJ [Btu/sf.F] [lb/cfj [h.sf.F/Btu] 1056 Mt1 Bldg Roof/R-19 Batt No No 0.05 1.34 9.49 20.3 ❑ Layer Material Material Thickness Framing No. Vt] Factor l 94 BUILT-UP ROOFING, 3/81N 0.0313 0.000 ❑ 2 23 6 in. Insulation 0.5000 0.000 [] No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F) [Btu/sf.FJ [ib/cf] [h.sEF/Stu] 1057 1 ft. soil, concrete floor, carpet and tubber pad No No 0.27 34.00 113.33 3.7 ❑ Layer Material Material Thickness Framing No. IN Factor 1 265 Soil, I ft 1.0000 0.000 ❑ 2 48 6 in. Heavyweight concrete 0.5000 0.000 ❑ 3 178 CARPET W/RUBBER PAD 0.000 ❑ No Name Simple Massless Conductance Heat Capacity Density RValue Construct Construct [Btu/h.sf.F] [.Btu/sf.F] [lb/ef] jh.sf.FBtu] 1058 Solid core flush (2.25) No Yes 0.35 2.9 [] Layer Material Material Thickness Framing No. [ft] Factor 1 279 Solid core flush (2.25") 0.000 ❑ 7/2/2020 EnergyCauge Summit@O v6.10 w Manual N, Sth Edition, Abridged Version a Form N1 Project Name 7369 COMMERCIAL Heating Design 99% DR 42 Heating Design Space DB 70 Heating Temp. Difference 28 ACCXDesign Design State City Florida Fort Pierce Cooling Design 1% DB Coincident Wet Bulb 90 78 Cooling Design Space DB Rel Hum Design Space % 75 50 Cooling Temp. Difference Design Grains Difference 15 64 Type of Load Block Elevation 25 Latitude 27 Daily Range M Square Feet 448 JAG Volume 1 4480 Altitude Correction Factor 1 Design Month Jul & Aug Design Hour of Day 3:00 PM Type of Exposure Construction Number &Description Panel Faces HTM Net Area or Length Btuh Heating Cooling Heating Clg Sensible Clg Latent O-Lookup a le-cuf-c Double pane, fixed sash, Metal no break North 19.32 31.40 40.0 773 1,256 b ' c Windows d Glass e Doors f 9 h P-Lookup a b Skylights c d e 0o up a 11J Metal, Fiberglass Core South 16.80 15.60 21.0 353 328 Wood & Metal b 11J Metal, Fiberglass Core South 16.80 15.60 21.0 353 328 Doors c lookup a 13A-5oc-b Block, brick exterior finish, R-5 insulation, open core, plus interior finish North 3.61 1.16 360 1,300 418 b 12B-Os-m Frame wall, Metal studs, R-11 cavity, wood sheathing, siding East 3.42 3.05 140 478 427 c 12B-Os-m Frame wall, Metal studs, R-11 cavity, wood sheathing, siding South 3.42 3.29 360 1,230 1,186 Above d 12B-Os-m Frame wall, Metal studs, R-11 cavity, wood sheathing, siding West 3.42 4.03 140 478 564 Grade e Walls f 9 h Partition Walls pi p2 0o up a 17B-15m-19 Metal deck plus R-15 board, R19 Suspended Ceiling 0.76 0.84 4,487 3,392 3,756 Ceilings b c Lookup a Floors b c d e f 22A-ph Slab on Grade, No Edge Insulation, Light Wet Soil 33.04 101 3,337 Lookup a Lighting Fixtures 4.80 2.40 0,007 0.052 0.005 0.034 Internal b Occupants & Plants c Office Equipment d Food Service Equipment and Investigated Loads e Blower Heat (Building Load) LOOKUP Infiltration 11,041 21959 7,806 ® Lookup Supply Duct Load 159 584 Return Duct Load 105 386 3,304 oo up Ventilation Loads CFM 71 2,187 1,172 3,090 0o up Blower Heat (Equipment Load) 561 Total Loads 25,187 13,923 14,200