Loading...
HomeMy WebLinkAboutBuilding PermitAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED Date: 1-18-2021 Permit Number: • Planning and Development Services Building and Code Regulation Division 2300 Virginia Avenue, Fort Pierce FL 3498.E Phone: (772) 462-1553 Fax: (772) 462-1578 Building Permit Application PERMITTYPE:A/C CHANGE -OUT PROPOSED IMPROVEMENT LOCATION: Address: 5612 TANGELO DR Property Tax ID #: 3402-610-0187-000-0 Site Plan Name: Project Name: Commercial Residential X Lot No._ Block No. DETAILED DESCRIPTION OF WORK: LIKE FOR LIKE REPLACEMENT OF (1) 3.5 TON TRANE A/C SYSTEM, 16.75 SEER WITH 10 KW ELECTRIC HEAT, CONNECT TO EXISTING REFRIGERANT LINES, DRAIN, DUCTWORK, HIGH AND LOW VOLTAGE ELECTRIC. CONSTRUCTION INFORMATION: Additional work to be performed under this permit —check all that apply: Mechanical _ Gas Tank Gas Piping Shutters _ Windows/Doors Electric Plumbing Sprinklers _ Generator Roof Pitch Total Sq. Ft of Construction: Sq. Ft. of First Floor: Cost of Construction: $ 5,885.00 Utilities: —Sewer —Septic Building Height: OWNER/LESSEE: CONTRACTOR: Name JOHN AND ALICIA DOTSON Name: DAMES F. GRIMES Address: 5612 TANGELO DR Company: GRIMES HEATING AND AIR CONDITIONING City: FORT PIERCE Stater Address: 3054 N US HWY 1 Zip Code: 34982 Fax: City: FORT PIERCE State: FL Phone No. 772-579-9455 Zip Code: 34946 Fax: 772-461-8722 E-Mail: NA Phone No 772-461-8711 Fill in fee simple Title Holder on next page ( if different E-Mail ROBERTGRIMESAC@AOL.COM from the Owner listed above) State or County License 4426 If value of construction is $2500 or more, a RECORDED Notice of Commencement is required. If value of HVAC is $7,500 or more, a RECORDED Notice of Commencement is required. DESIG Not Name: Address: City: State: Zip: Phone FEE SIMPLE TITLE HOLDER; Not Applicable Name, Address: City: Zip: MORTGAGE COMPANY: Not Applicable Name: Address: State: City: Zip: _ Phone: — BONDING COMPANY: Not Applicable Name: Address: City: Zip: Phone de to obtain a permit to do the work and installation as indicated. OWNER/ CONTRACTOR AFFIDVIT: Application is hereby ma I certify that no work or installation has commenced prior to the issuance of a permit.. yy permit will authorize or and covenantsholder that maydrestrictbor prct ohibit such ILucis Inoeontitlict with any representation that aowners granting rules, bylam deed for any restrictions which may apply. structure. Please consultw�ih ynur Horne Owners Association and review y In consideration of the granting of this requested permit, I do hereby agree that k will, in all respects, perform the work in accordance with the approved plans, the Florida Building Codes and St. Lucie County Amendments. The following building permit applications are exempt from undergoing a full concurrence review: room additions, accessory structures, swimming pools, fences, walls, signs, screen roams and accessory uses to another non-residential use CE OF COMENCEMENT MAY RESU "WARi111IMIG TQ OWNER: Y®UR FAIT® YOUR PROIPERTY- AT11 NOT CE O MCOMMENCEIM EN M UST IN RECORDED AND TWICE FOR IMPROVEMENTSON. IF YOU POSTED ON THE !OB SITE BEFORE� THE � BEFOREFIRST INSPECTIRECORDING YOURNQT�C OFCOMIMENCEMI NT!' ,CONSUL WITH YOUR LENDER OR AN Fof owner/ Lessee/Contractor as Agent for Owner STATE OF FLORIDA COUNTY OF S'n ��• The fnrsrning instrijpetwas acknowledged before me this -day of ZO Z� by n Dame of person making statement. Personally Known_ OR Produced Identification Type of identification Produced Signature of Notary Public- State Commission No. 'V ,o. REVIEWS FRONT COUNTER DATE RECEIVED COMP (St AN NAON'TENEGRO My COMMISSION n GG 08z REVIEW I REVIEW C SI ature of Contractor License Holder STATE OF FLORIDA COUNTY OF The for wing instrum�r�nt was acknawiea by re me this r~ day of _ Name of person making statement• Personally Known - .OR Produced Identification Type of Identification Produced _ of Notary Public- state of Florida ) _ fly COMMISSION � GG U89U99 B,x�Thiu 4r9 PuNw U erwi tees 'V ANS VEGETATI REVIEW REVIEW REVIEW REVIEW This combination qualifies for a Federal Energy Efficiency Tax Credit when placed in service between 1/112015 and 12/31/2020. Certificate of Product Ratings AHRI Certified Reference Number : 8631021 Date : 01-18-2021 Model Status : Production Stopped AHRI Type: RCU-A-CS (Split System: Air -Cooled Condensing Unit, Coil with Blower) Series: XL16 Outdoor Unit Brand Name: TRANE Outdoor Unit Model Number (Condenser or Single Package) : 4TTX6042J1 Indoor Unit Model Number (Evaporator and/or Air Handier): TEM6AQD48H41+TDR Region : All (AK, AL, AR, AZ, CA, CO, CT, DC, DE, FL, GA, HI, ID, IL, IA, IN, KS, KY, LA, MA, MD, ME, MI, MN, MO, MS, MT, NC, ND, NE, NH, NJ, NM, NV, NY, OH, OK, OR, PA, RI, SC, SD, TN, TX, UT, VA, VT, WA, WV, WI, WY, U.S. Territories) Region Note : Central air conditioners manufactured prior to January 1, 2015 are eligible to be installed in all regions until June 30, 2016. Beginning July 1, 2016 central air conditioners can only be installed in region(s) for which they meet the regional efficiency requirement. The manufacturer of this TRANE product is responsible for the rating of this system combination. Rated as follows in accordance with the latest edition of AHRI. 2101240 with Addendum 1, Performance Rating of Unitary Air -Conditioning & Air -Source Heat Pump Equipment and subject to rating accuracy by AHRI-sponsored, independent, third party testing: Cooling Capacity (A2) - Single or High Stage (95F), btuh : 41000 SEER: 16.75 EER (A2) - Single or High Stage (95F) : 14.00 t"Active" Model Status are those that an AHRI Certification Program Participant is currently producing AND selling or offering for sale; OR new models that are being marketed but are not yet being produced "Production Stopped" Model Status are those that an AHRI Certification Program Participant is no longer producing BUT is stM selling or offering for sale. Ratin s that are a%)si anied b WAS indicate an involunta re rate. The new published ratingis shown alon with the rev'sous i.e. WAS ratin . DISCLAIMER AHRI does not endorse the product(s) listed on this Certificate and makes no representations, warranties or guarantees as to, and assumes no responsibility for, the product(s) listed on this Certificate. AHRI expressly disclaims all liability for damages of any kind arising out of the use or performance of the product(s), or the unauthorized alteration of data listed on this Certificate. Certified ratings are valid only for models and configurations listed in the directory at www.ahrid!rectory.org. TERMS AND CONDITIONS This Certificate and its contents are proprietary products of AHRI. This Certificate shall only be used for individual, personal and confidential reference purposes. The contents of this Certificate may not, in whole or In part, be reproduced; copied; disseminated; entered into a computer database; or otherwise utilized, in any form or manner or by any means, except for the user's individual, AIR-CONDITIONING, HEATING, personal and confidential reference. $ REFRIGERATION INSTITUTE CERTIFICATE VERIFICATION The information for the model cited on this certificate can be verified at www.ahridirectory.org, click an "Verify Certificate" link we make life better" and enter the AHRI Certified Reference Number and the date an which the certificate was issued, which is listed above, and the Certificate No., which is listed at bottom right. 132554571916301386 02021 Air -Conditioning, Heating, and Refrigeration Institute CERTIFICATE NO.: