Loading...
HomeMy WebLinkAbout9630 Knollwood Ln - Plans NOTE:THIS DRAWING IS FOR ILLUSTRATIVE PURPOSES.DRAWING NOT TO Y Thus item has been eieo- Design Parameters SCALE.USE DIMENSIONS GIVEN.CABLE BRACING MAY TERMINATE AT SLAB W troi�ally-steed-d d` •If-.�7 p'sealed by Edw-d R-J. 'e E H,s'., 1. Building Occupancy Category,Paragraph 1604.5 and Table 1604.5:Risk IN DIFFERENT LOCATION.MAINTAIN ANGLE PER DETAIL. ?rr..'� Category I. 10 t „Printed a DigitalP tore-Printed co i Nu.72228 3 this document are not *• * •*' 2. Basic Wind Speed,Table 1609C,State of Florida Debris Region& Basic Wind ssaerea s yea ana STATE OF Speed Paragraph 1609.3.1 and Table 1609.3.1 Equivalent Basic Wind Speed, w�ealea andthe g a=•" VuLT=150 MPH „mot he-if.a on any 3. Exposure Category,Paragraph 1609.4.3:C electronic copies- +Gtl,4l. Applicable Codes,Regulation and Standards Edward Ros k 1. The 7th Edition(2020)Florida Building Code,specifically Chapter 16 Structural Design,Chapter 20 Aluminum,and Chapter 23 Wood. 0 1 0 1 1 2. AA ASM 35 and Specifications for Aluminum Structure,Part 1-A of the Aluminum Design Manual prepared by The Aluminum Association,Inc.Washington,D.C., C14 2010 Edition 3. ASCE7-16 00 05- 14:14: General Notes 1. The contractor shall verify all dimensions prior to construction 2. All work shall comply with all local and regional ordinances. / 3. Any deviation from this plan shall be reviewed by the engineer of record and iE (•ry subject to approval. Specifications W C The following specifications are applicable to this projects: f1z ° HOST r-� „ r•y 1. Where concrete specification are required,whether in the screen enclosure scope - j 3-o fi �-o t-3-o-f - - - -- - -- -- - -- - -- - -- - - - ° - ----------------- -- - - -- -- - -- 1X2 aooc oveaHnrvc .N. or not,by one or more regulatory agency,the following specifications are 1 1X2 applicable. w zxz DJ X2(TYP) X O DJ-1 1.1. Concrete shall conform to ASTM C94 for following components: b o �� R;' f x z ° o 1.1.1. Portland Cement Type 1,-ASTM C 150 J- 2x2 DJ �� ' �a ti+� ti+� 2X2 DJ w u 1.1.2. Aggregate-Large Aggregate 3/4"max-ASTM C 33 f Rc-z i w o o d 1.1.3. Air entraining+/-1%-ASTM C 260 o N 1.1.4. Water reducing agent-ASTM C 494 r- PFB �� zxa zxa zx3 2- zxa zx3 zx3 5.75 zcd 1.1.5. Clean Potable water M 9 1.1.6. Other admixture not permitted � I I M-1 z a+"i 1.2. Metal accessories shall conform to: frl b_ i �+a y+' i z > o O r�� U 1.2.1. Reinforcing Bars-ASTM A615,grade 60 � 9 i N i Q W 1.2.2. Welded wire fabric-ASTM A185 CA < U 5.75 o v 2X3 2X3 2X3 2X3 2X3 2X3 2X3 I 5.75 0 > 1.3. Concrete slump at discharge per chute not less then 3"or more than 5". > o PFB I a o i UJ Water added after batching is not permitted. � I N I W 1.4. Prepare and place concrete per American Concrete Institute Manual of O i o BZs i o F- Standard Practice,Parts 1,2 and 3 including hot weather recommendation, Z b i +' ti+ X2X3 1.5. Moist cure or polyethylene curing required.1.6. Prior to placing concrete,treat the entire subsurface area for termites in5.752X3 2X3 2X3 2X3 2X32X3 i 5.75 ; compliance with the FBC. PFB 1.7. All aluminum components embedded within concrete shall be coated with E i z' bituminous paint or epoxy. - o �� o 1.8. Fiber reinforced concrete per ASTSM C1116 is an acceptable alternative tc " " �� x 6X6 W1.4/W1.4 WWF. 2. Aluminum extrusions shall be 6005 T5 Alloy. 1x2 L \V 1x2 a> 3. Fasteners are required to be corrosion resistant,minimum SAE Grade 2 or better v + 6'-1121 k - + E' 21 # - 7 fi'-11- fi'-11- zinc plate to ASTM 6633,or stainless steel series"300". 2 fi'-11 z -11z E'-11 z z 2 1121 4. All Self Mating Beam Sections and PFB are to be stitched with either 414 screws 48'-8 I 2'-C" 6"from end 24"on center or#12 screws 6"from end 12"on center. 4.0 y LID 5. Screened enclosures containing swimming pools shall comply with the applicable PLAN VIEW -q requirements of FBC R4501.17 and FBC 454.1.3.1.9. M C - M 6. Door location shall be determined by contractor in the field. Mp 7. When installing pavers over concrete slab or footing which are supporting 3 a aluminum members,such as continuous screen tracks or upright,the anchors - O must extend past the pavers and reach proper embedment into the underlying Dj foundation. 1x2(TYP) 1X2(TYP) IU Y 8. All flashing and waterproofing shall be provided by the contractor. BR-1 Rcr L U) e 9. Use of these plans acknowledges and accepts a limit of liability not to exceed z ' Q d cMp a) design and engineering fee. I.i in a 10. Vinyl and acrylic panels shall be removed when wind speeds exceed 75mph / Q 6 X A+ y LL tU Foundation Design:Existing 8"x8"Thickened Edge 4"Slab on Grade a) BJ L Existing concrete.No additional concrete footing is required to resist the loads imposed ; (l by the proposed construction if the existing footing is in sound condition,free from 1X2(TYP) x2(TYP)'., structural cracking,spelling,or other deterioration. 32-°" ! 16.-8" Roof Type Screen Size as s I Full Mansard 18/14 FRONT ELEVATION ALUMINUM MEMBER DIMENSIONS HOLLOW SECTIONS SELF MATING BEAM(SMB) OTHER SELF MATING BEAMS 2 x 2:2"x 2"x 0.046" 2 x 4 SMB: 2"x 4"x 0.044"x 0.100" 3.75 PFB: 2"x 3.75"x 0.050" 2 x 3:2"x 3"x 0.050" 2 x 5 SMB: 2"x 5"x 0.050"x 0.100" 5.75 PFB: 2"x 5.75"x 0.055" 2 x4:2"x4"x0.050" 2x6SMB: 2"x6"x 0.050"x 0.120" COLUMNS 2x5:2"x5"x 0.050" 2x7SMB: 2"x7"x 0.057"x 0.120" 3x3:3"x3"x 0.125" 2x8SMB: 2"x 8"x 0.072"x 0.124" 4x44"x4"x0.125" SHEET OPEN BACK SECTIONS 2 x 9 SMB: 2"x 9"x 0.072"x 0.124" 6 x 6:6"x 6"x 0.125" 1 x 2:1"x 2"x 0.040 2 x 10 SMB:2"x 10"x0.092"x 0.398" 1 x 3:1"x 3"x 0.045' MINIMUM FASTENER EDGE DISTANCE:1/2" KB:KNEE BRACE SNAP SECTIONS MINIMUM FASTENER SPACING:3/4" RC:REC.CHANNEL 2 x 2 Snap:2"x 2"x 0.045" CONCRETE SCREW ANCHOR: SHEET MATEL SCREWS(SMS): 2 x 3 Snap:2"x 3"x 0.050" SIMPSON TITEN HD OR EQUIVALENT ITW BUILDEX OR EQUIVALENT 2 x 4 Snap:2"x 4"x 0.045" d 00 ***NOTE-NOT ALL DETAILS ARE USED FOR THIS PROJECT.SEE PLAN FOR DETAIL CALL OUTS*** y N O N Q' r 1/8"BRACKET CUT Note-Orientation may be different. `m w FROM 1"x 5"ANGLE. 3 d CONNECT WITH(9) 3/16"GUSSET Lu W #14 X 3/4"SMS 7" 1-1/4"x 5-5/8"x 1/8" PURLINS ATTACHED TO BEAM ��ALUM.FLAT BAR. WITH(4)#10 x 1-1/2"SMS WITH 6063-T6 ALUM. WASHE INTO SCREW BOSSES. O O O O O ° N #14 X 3/4"SMS @ 1-1/4"O.C. O d a c ° c O EVE RAIL ° d C O EYE BOLT FOR CABLE TENSION ° ° ° x 2"x 2: N 0 2"x 2"x 1/8"ANGLE WITH(2)#10 x O 3/4"SMS IN EACH FLANGE,EACH r SIDE(TYP) N (2)3/8"DIA.x 3"EMBED OPTION 1: PURLIN/GIRT/CHAIR RAIL CONCRETE SCREW ALTERNATE CONNECTION (4)#10 x 1-1/2"SMS INTO ANCHOR SCREW BOSSES(TYP) UPRIGHT 1/8"S.S.CABLE 00 1-1/4"x 5-5/8"x 1/8"ALUM.FLAT a 2' S W � d DOUBLE BAR.WITH(2)3/8"DIA.CONCRETE N I COMPRESSION ANCHORS.MIN.2-3/4"EMBEDMENT ^ M b d SLEEVES SNAP OR� � � � M '� o• / SELF-MATING BEAM ONLY 7 �' ..N. O wooD: #10 x 3"WOOD SCREWS @ 6"FROM Z = BRICK PAVERS MAY NOT ENDS&12'O.C. BE PRESENT.ENSURE z o w CONIC MIN.REQUIRED ANCHOR z NOTES: 1/4"DIA.x 3"CONCRETE SCREW w " L EMBEDMENT INTO ° ° v 1. SEE THE NOTE BELOW FOR SCREWS SPACING.THE NUMBER OF SCREWS SHOWN ARE ANCHOR @ 6"FROM ENDS&24"O.C. W N d CONCRETE \�z FOR ILLUSTRATIVE PURPOSES.DO NOT COUNT SCREWS ON DRAWING. i E ° ''? 0 2. GUSSET DIMENSIONS AREA MINIMUM(2) REQ'D-(1)EA SIDE OF BEAM-MAY BE INTERNAL OR EXTERNAL $ . is d FOUNDATION PER PLAN a c d ° d° 3. AS BEAM SIZE CHANGES,ADD OR SUBTRACT SCREWS TO MAINTAIN 11/4"C/C SPACING. i+ 4. GUSSET LENGTHS REMAIN CONSTANT WIDTHS CHANGE TO MATCH BEAM SIZE. ry, � V 4 TWr^^ 3 v1 BR-1 CABLE BRACING G-1 TYPICAL INTERNAL/EXTERAL GUSSET CONNECTION M-1 PURLIN/GIRT/0.13 TO HOST CONNECTION 2 SCALE:NTS 2 SCALE:NTS 2 SCALE:NTS (1)1/2"DIA THRU BOLT WITH 1/8"x 2"x 2"ANGLE WITH 2"x2"x1/8"ANGLE EA NYLOCK JAM NUT(JAM NUT WITH �(4)#14 x 3/4"SMS INTO GUSSET PLATE SIDE THREADLOCKER MAY BE USED,IN ® ® POST PER PLAN/DETAILS LIEU).DO NOT OVER TIGHTEN. TIGHTEN ONLY UNTIL CONTACT. ®O RICK PAVERS MAY NOT FOR 2X2 AND 2X3 UPRIGHTS,USE (4)#14 x 3/4"SMS INTO POST BE PRESENT.FOLLOW ` ANCHOR MINIMUM Q ^ BRICK PAVERS.MAY NOT U. 4 ONCRETE EMBEDMENT PURLIN LL PURLIN L O BE PRESENT.ENSURE p O MINIMUM CONCRETE EMBEDMENT. z r � �"� y � a p W dd° d �Ow X I ° d a �w M (2)#14 X 2"SMS THRU BRACE INTO O fC n m Z ® ® °da ° wBEAM THRU GUSSET PLATE coOO " Nw TOP VIEW 0 0 — SIDE VIEW AT INTERMEDIATE UPRIGHT SIDE VIEW C) 0 Y y FOUNDATION PER PLAN J PER PLAN In BRACE AT INTERMEDIATE JOINT O ayi M a`) UPRIGHT PER PLAN Lq�_ _ 1x2 O.B.ANCHORED TO-CONCRETE WITH 1/4"DIA. /1 a(1)3/8"DIA CONCRETE 1X2 O.B.ANCHORED TO CONCRETEANCHOR(MIN.1-1/4" SCREW ANCHORS INTO WITH 1/4"DIA.CONCRETE SCREW EMBED)@ 24"O.C. O LL EACH LEG ANCHOR @ 24"O.C.MAX W V 1 Q \ (4)#14 x 3/4"SMS INTO POST N FOR CORNER CONNECTION ® w 4)#14 x 3/4"SMS INTO p a FASTEN 1X2 WITH#12 x 3/4" X POST 04.IL SMS @ 24"O.C. O 3/8"DIA.CONC. e ANCHOR.EMBED MIN. jQ1X2 2-1/2" wUPRIGHT ° � ed (4)#14 x 2"SMS THRU 1X2 J OOTING.SEE PLAN FORDIA.THRU BOLT WITH NYLON INTO POST FRONT VIEW DETAILS BRACE AT EAVE RAIL WASHER&STAINLESS STEEL NUT FRONT VIEW TOP VIEW AT CORNER SHEET B-1 UPRIGHT TO FOUNDATION CONNECTION DJ-1 DOOR JAMB CONNECTION BR-3 ROOF BRACING 2 SCALE:NTS 2 SCALE:NTS 2 SCALE:NTS 2 d00 ***NOTE-NOT ALL DETAILS ARE USED FOR THIS PROJECT.SEE PLAN FOR DETAIL CALL OUTS*** y N O N Q It- 4t W 3a 0.125"THICK"Z"BRACKET @ EACH BEAM/PURLIN. ATTACHED BRACKET TO FASCIA W/3/8"x 3"LAGS(3 NOTE: W PER BRACKET).ATTACH GUTTER TO FASCIA WITH (2)3/8"DIA.x 4"LAG SCREWS FOR ATTACH INSIDE FACE OF BEAM WIT 3/8"X 3"LAG @ 24"O.C.ELSEWHERE. SPANS GREATER THAN 30'-0" COLUMN USING 2"x 2"x x BEAM DEPTH LONG ANGLE WITH(8)8)##14 x 3/4" 1"X 2"OPEN BACK IS NOT NEEDED IF SMS EACH LEG. GUTTER HAS SPLINE GROOVE. OTHERWISE,CONNECT 1X2 TO COLUMN PER PLAN.NOTCH COLUM BEAM/PURLIN WITH(2)#10 x 2-1/2"SMS TO ACCEPT CARRIER BEAM THRU BEAM/PURLIN INTO SCREW BOSSES.CONNECT 1X2 TO GUTTER 1-1/2"x 16"x 0.125"ALUM STRAP 0 O NOTCH BOTTOM FLANGE OF OUTSIDE WITH(5)#14 x 3/4"IN BOTH N WITH(1)#14 x 1-1/2"SMS @ 6"FROM CARRIER BEAM AND POST EACH SIDE. PURLIN TO OVERLAP UPRIGHT (10 TOTAL) M ENDS AND 24"O.C. DETAIL AT CORNER (PLAN VIEW) N SCREW THRU EAVE RAIL r INTO PURLIN SCREW BOSSES WITH(2)#10 x 4" O 0 011CD 4=110 O SMS O E O 4=110 O ATTACH 1X2 TO EAVE RAIL O O WITH#10 x 1-1/2"SMS @ 6" 00 pFgM 0 100 FROM ENDS&24"O.C. W .1 y 00 00 Z e 0 2"x 7"x 1/8"PLATE WITH(4)#14 0 x 3/4"SMS EACH SIDE OF BEAM ~ eyC L ONTRACTOR TO VERIFY FASCIA IS T M1 N '� •p 2"x 2"x 1/8"x 2"ANGLE WITH(4 MINIMUM OF 2"x4".IF LESS,2"X4" U 'y; e #14 x 3/4"SMS INTO BEAM/PURLIN PT SUB FASCIA SHALL BE PLACED AND(4)[(2)IF 1X2 IS SCREWED TO BEHIND EXISTING AND LAG LAG BEAM USING SCREW BOSSES]#14 LSUPER GUTTER SCREWS SHALL BE LENGTHENED UPRIGHT PER PLAN [_] n X 3/4"SMS INTO 1X2(OR GUTTER). TO FULLY PENETRATE SUB FASCIA. 1"x 2"O.D.ATTACH TO UPRIGHT r� w REPEAT ON OTHER SIDE OF IF NO FASCIA IS EXISTING,ADD 2"x WITH(2)#10 x 2 1/2"SMS THRU W C b d BEAM/PURLIN 4"PT FASCIA WITH 1/2"DIA.LAG UPRIGHT INTO SCREW BOSSES i 7 E BOLTS,EMBEDDING 1-1/2"INTO Q PLUS#10 x 1 1/2"SMS 6"FROM $ WHEN BEAM IS LARGER THAN GUTTER, .062"BACKING PLATE 1"x 2"O.B.ATTACHE 2 1/8"x 1 1/8"x 0.062"(MIN.)ALUM ON INSIDE OF GUTTER TRUSS TAILS.PRE-DRILL WITH 3/8" EACH SIDE OF POST EACH SIDE OF UPRIGHT AND , d RECEIVING CHANNEL W/MIN.(2)#12 x DIA BIT TO PREVENT SPLITTING. WITH#12 x 1-1/2"SMS TYPICAL AT 24"O.C.MAX 3/4"SMS SHIM AS NECESSARY IF OTHER @ 6"FROM BOTTOM �I THAN A PLUMB CUT FASCIA. AND 24"O.C. [��V U NOTE:BEAM ORIENTATION MAY BE DIFFERENT THAN ILLUSTRATED NOTE:IGNORE 1"X 2"O.B.AND CONNECTION IF SCREEN ISN'T BEING INSTALLED V1 RH-1 BEAM/PURLIN TO GUTTER CONNECTION RC-4 CARRIER BEAM TO COLUMN CONNECTION RC-Z UPRIGHT TO PURLIN CONNECTION 3 SCALE:NTS 3 SCALE:NTS 3 SCALE:NTS 2"x 2"1/8"x 2"LONG ANGLE WITH (2)#12 x 1-1/2"SMS INTO POST&(1) 3/8"DIA X 2-1/2"CONCRETE SCREW ANCHOR ANCHOR INTO UNCRACKED 2)3/8"DIA THRU BOLTS IN COLUMN CONCRETE(HOLE DEPTH=3-1/2") AND INTERNAL ANGLES. BEAM/PURLIN #OF SCREWS IN EACH LEG V O SIZE OF ANGLE 1"x 2"O.B. 2X2-2X3 4 ,n 2"x 2"x 1/4"(LENGTH=INTERIOR OF 2X4-2X5 6 O WIDTH OF COLUMN)ANGLE WITH 3/8" 2X6-2X7 8 }E y TABLE"A" DIA CONCRETE SCREW ANCHORS SEE O ( ¢ 2X8-2X9 10 a) #of Anchors ® ® TABLE"A•FOR QUANTITY)MIN 2-1/2" ui Column Size m 2X10 12 3x3 Each1Side INTO UNCRACKED CONCRETE(HOLE - -0 M DEPTH=3-1/2").(2)3/8"DIA BOLTS O M O M 6xs 3 THRU COLUMN ROOF BEAM/ 3 L PURLIN PER PLAN O O LL ® O O ® CARRIER BEAM 1 Y (IT COLUMN PER PLAN L N O 0 PLAN VIEW O a 1•xz^O.B. AT CORNER POST A+ a O LL Y^^/ V ITT ITT ATTACH 1X2 TO ROOF BEAM i N ®O WITH (2)#10 x 2"SMS L 0 ® ® INTERNAL INTO SCREW r a BOSSES(NOT SHOWN FOR CLARITY).ATTACH 1X2 TO CARRIER BEAM WITH#14 x 1-1/2"SMS @ 6"FROM ENDS &24"O.C. ATTACH ROOF BEAM/ ® O ® ® ® PURLIN TO CARRIER BEAM CARRIER BEAM PER //LL WITH 2"x 2"x 1/8"x[DEPTH PLAN OF ROOF BEAM]LONG ANGLE WITH#14 x 3/4"SMS. 1"x 2"O.B. 1"x 2"O.B. SEE TABLE FOR QUANTITY OF SCREWS.(TYP EACH AT CENTER POST SECTION VIEW SIDE) NOTE:OMIT 1X2 IF NO PROPOSED SCREEN. NOTE:BEAM ORIENTATION MAY BE DIFFERENT THAN ILLUSTRATED SHEET B-3 POST TO FOUNDATION INTERNAL CONNECTION RC-5 CARRIER BEAM TO ROOF BEAM/PURLIN CONNECTION 3 SCALE:NTS 3 SCALE:NTS 3