Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Truss
i 'I ,� ' TRUSSES FOR THE FIRST MODEL SHOULD BE SHIPPED AND SUCCESSFULLY SET BEFORE ANY MORE TRUSSES ARE BUILT FOR T-iAT MODEL. ®=LIFE SAFE TY WARNING �► ARRAN E WITH CRANE OPERATOR IN OPE ADVANCE FOR A SPREADER BAR OF 18' - 24' IN LENGTH _ %i `A This symbol identifies Life afety Warnings that should be read J given special attention by Il persons installing trusses. ® Do not stand on trusses u til they are braced per BCSI & properly nailed to straps & hangers V L I II 15'-3" - - --- 19'-9" 19' 9" 15'-3" C L G SPA ING NOTE X - - - - - I TRUS fS ARE TO BE SET r T A {{2 -0 ON CENTER — EYG ?T AS NOTED I - -- T MUST BE MULTIPLE PI TRUSSES ASTENED TOGETHER PER ENGINEERING BEFORE Si TTING. REFER TO ENGINEERING DRAWING TO DETERMINE A IF MbLTIPLE PLY. Lci s ill I li I, DON' LIFT TRUSSES WITH SF NS LONGER THAN 3b',�BY THE PEAK. tNSULT BCSI 30' Spanllor less 30' to 60' Span I Sprea er Bar �x �6G deg ees ' \ or Iess �I APprox 2/3. tom SF`C'° C.r)i.. rC X. II Line 1/2 of Span q L.;re RETER HCSI REFER TO BCSI T !! Trussmust be set this way if crone used. rus5 must be set t ay I< crane uIs P •uss Is an example, you t uss may oaf mot�n This is an example, truss may not match. Insist crone operator sets truss this way. Ins st crane operator sets trussth s way Ik All load be 11 c ring walls, headers, beams & lin els must be in place at indicated;V eight before trusses A al Installed. c; AIF? FiA li pI_�F2 NOTE a UNLESS NOTED ELSE'iERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED �F�R AIR HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQ IREMENTS. THIS MAY BE IN CONFLICT WITH BUILDING CID�E AND A/C DESIGN REQUIREMENTS. CONSULT WITH BUILD[ G DEPARTMENT AND A/C CONTRACTOR. ' Carrying Girder ForTruss_to j uss Connections;i ee IT hanger/conne for a ' schedule in engjl leering package` 'Nails must be as shown. Guide tabs Dome angle nails. Carried Truss SEAT PLA ES BY CHAMBERS HIP li ANYIE0.LOLRT[O AS DIMENSIONED ON IAYWi x� aN EH J♦�G(5 1 oN,Y--i4.-14y 12 4.00 1— CORNER DETAIL f; OVERHANGS NOT SHOWN FOR CLARITY it I, upset=1/4" heel=315116" IY PLUMB CUT END 2 x 4 Top Chord I�I WALL HEIGHT 8' V i l li TYPICAL END DETAIL 12 4.00 r h� co 2.00�1 $ --- 12 'e co i_ upset=1/4" heel=l 15/16" INDICATES LOAD BEARING PLUMB CUT EN REQUIRED BY TRUSSES SUPPLIED BY BUILDER 2 x 4 Top Chord AT A HEIGHT OF 8'-0" WALL HEIGHT 8: ABOVE FINISHED FLOOR END DETAIL Tl ICI [CAL VAULT 1 v I I I I r ��y / J / .. 1 O�.'/I/�/I♦// I I 1 �1 /I I I 1 1 I I I 1 i / — 'pool s PON ON ®0110 -- —21 PAP — 010 1INVERTED ' wV"WEBS AT ... PO NT LOADS PER TRUSS FOR AJ`H1U y50# Fir MIA ONE IVA� a ® 1 � I r / 1 rr I r I e r 1 I yoola, � yl/,��,�rr�/i.i/hill/mil/i/oaoo,riiiil//ioa///a.,� I v t/ 1I I I I / I r I 1 •♦ 1 I ®I®I®I®ICI®I�BII�I�I�IB�I�I®I®ICI®I®I�► t C O I FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED 8 RETU13NE❑ The legal description of the property where the trusses will be Installed II The undersigned acknowledges and agrees: 1; Trusses will be made In strict accordance with this truss placement diagram layout, whlch13 the sole authority for determiningsuccessful fabrication of the trusses, 2. All dimensions In this layout have been verified by the undersigned. .3, llnleae written notice Is provided by certified mail to Chambers Truss within ten (10) day( of delivery the undersigned agrees that no baokcharges will be allowed,.ln the event such written In Dim le tumished Chambers Truss shall have three (3) bu�ness days In which > to be81n repairs required, or to substitute olhec trusses, at Chambers option.' ersl red ecknowfed es receipt 4, Tho and re t of"BCSI g BCSI 1-03" summary sheet b '(P P 18 WiCA ry Y Is to job site. It Is the b er ' (i. Delivery s rea nc e ry 1 uy IWII to make N Job site suit Po 1 able for ty o ' delivery. Chambers Truss has the sole authority to detertnlno the suhabllity of the ob site of a job site Mr dative ha Thelon of the j delivery, C tubers Truss will be responsible for dump dative ry only. The buyer Is responsible for additional delivery expanses If Chambers Truss has to redellver because job she Is not praparod for delivery or buyer le not prepared for delivery of trusses, Guyer is responsible to Chambers Truss for towing costs due to she conditions. S. Price as shown In paragraph 7 below is subject to change If any changes era, made In this layout A $50 per hour fee for revisions may be charged by Chambers Truss, 7, This Is a PURCHASE ORDER to Chambers, Truss of the sum agreed to, or If no ` 'agreement a reasonable price. Invoice will be made on delivery and paid within terns of nett on delivery. Invoice may, be made at scheduled date of delivery If buyer cannot accept' dellvary of fabricated Wawa. The undersigned agrees to pay Chambera.TNss reasonable 8"OrIy'a fee for collections In event of payment not timely made. 1.112 %,, per month servjce charge will be added for all sums not paid within terms. ' 8, Signature or In l is anywhere on this sheet constitutes agreement to all terns heroin, e. In consideration of Chambers Truss extending credit for this materiel the undersigned unconditionally guarantees payment when due of any and all Indebtedness owed to Chambers Truss by any entity receiving material and the undersigned agrees to pay such Indebtedness Including attorneys fees, If default In payment fir material be made by the recipient 1. 10. In the event of any litigation concerning INS agreament,4he items furnished hereunder or payments referred to herein, the, parties agree that the sole venue for any such action will be Saint Lucie County, Florida.. 11. Design responsitillit es are per "National Standard And Recommended Guldellnes On Responsibilities For Construction Using Metal Plate Connected Wood Trusses ANSIRPVWTCA 4 - 2002- DATED SIGNED -, FOR TITLE ' Aspeaderbarmaybe reggifredper"BCSI 1-03"tD pnaIont Idury& damago. Multiple ply trusses must be fastened together per engineering before they are set failure to do so can resultdn roof collapse. temporary and permanent bracing are required and can save life and property and is the responsibility of the truss erector. 'Study the contents of the lnforrnatlon packet included on delivery before setting trusses. Tiiaafes must be set and txacac7 per design m ptovent inJury &damage. Trusses must be sot plumb and square Do notset bunks or stack of plywood, roofing material or any other Concentrated loads on trusses, this can cause collapse. DO NOT SET TRUSSES USING THIS TA Your ` USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES 1 CHAMBERS TRUSS INC 3106 Oleander Avenue Fort Pierce; Florida 34982-6423 800-551-5932 Fort Plerce 772.465-2012 Fax 772.465.8711 Vero Beach 7JI-5R9-2012 Stuart 772-2863302 ' Th — rtect s or Architect's representative's shop drawing approval is NOT a "doubia chock",of the contractor. The contractor shall remain responsible for. checking field measurlannents and other construction criteria„ 4rchite!ct's wocovers ge»grail radf shape, review off t (rugs strapping,.andllloading on ar ucture from gravely and uplift loads and their re live locations. APProved By id, Xf Date: t3raden A Braden A.LA. P.A. 92.0/93.2MITEK 4.2 DESIGN CRITERIA County SAINT LUCIE Building Department ST LUCIE COUNTY Wind Design Criteria ASCE 7-2010 Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10 aRoofing Material Shingle or Shake «r`I Loading in PSF Roof R.D.L. w Top Chord Live 20 w I o I Top Chord Dead 7 4.2 L $� Bottom Chord Live 10 Non -Concurrent o c Bottom Chord Dead 10 3 TOTAL Load 37 7.2 Duration Factor 1.25 � Wind Speed 165mph y Top Chord C.B. Sheeting by builder. H Bottom Chord C.B. Sheeting by builder. t? Highest Mean Height 15'-0" Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2017 K.U.L.=mesuainin Ueaa LOBO t-.b.=kxonrinUOUS braCtn Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of' the Buildino Designer and/or Engineer of Rerx4rd LLChambers Truss Inc. Drawing Name: M11392 Scale: 1/4 - 1' UJ82 total trusses, 15 different trusses. MI 4: RLC ACAD: RLC Reviewed By: Date:10/07/15 vi Re sed:0 2 3/ 1/18 ' I V J FOR Revised: 3/05/2020 -- yam_ 14'4" _--- 6'-4" 14'-4" �FIEVIEW OPWYNNE BUILDING CORP. - - cooE CO Any CLOU'SED AREAS ARE OF �� Sal. LUCIE N-gDESCRIPTION: / SPECIAL CONCERN & MUST BE t PORCHLEFT WINDSOR CHECKED CAREFULLY & MAY �Q PAGE 1of1CUSTOMER INITIALS EACH PAGE 770�S� t INDICATE DEVIATION FROM �__�� `._ PLANs',,, 15 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M1 1392J� �G orfti FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED 8 RETU13NE❑ The legal description of the property where the trusses will be Installed II The undersigned acknowledges and agrees: 1; Trusses will be made In strict accordance with this truss placement diagram layout, whlch13 the sole authority for determiningsuccessful fabrication of the trusses, 2. All dimensions In this layout have been verified by the undersigned. .3, llnleae written notice Is provided by certified mail to Chambers Truss within ten (10) day( of delivery the undersigned agrees that no baokcharges will be allowed,.ln the event such written In Dim le tumished Chambers Truss shall have three (3) bu�ness days In which > to be81n repairs required, or to substitute olhec trusses, at Chambers option.' ersl red ecknowfed es receipt 4, Tho and re t of"BCSI g BCSI 1-03" summary sheet b '(P P 18 WiCA ry Y Is to job site. It Is the b er ' (i. Delivery s rea nc e ry 1 uy IWII to make N Job site suit Po 1 able for ty o ' delivery. Chambers Truss has the sole authority to detertnlno the suhabllity of the ob site of a job site Mr dative ha Thelon of the j delivery, C tubers Truss will be responsible for dump dative ry only. The buyer Is responsible for additional delivery expanses If Chambers Truss has to redellver because job she Is not praparod for delivery or buyer le not prepared for delivery of trusses, Guyer is responsible to Chambers Truss for towing costs due to she conditions. S. Price as shown In paragraph 7 below is subject to change If any changes era, made In this layout A $50 per hour fee for revisions may be charged by Chambers Truss, 7, This Is a PURCHASE ORDER to Chambers, Truss of the sum agreed to, or If no ` 'agreement a reasonable price. Invoice will be made on delivery and paid within terns of nett on delivery. Invoice may, be made at scheduled date of delivery If buyer cannot accept' dellvary of fabricated Wawa. The undersigned agrees to pay Chambera.TNss reasonable 8"OrIy'a fee for collections In event of payment not timely made. 1.112 %,, per month servjce charge will be added for all sums not paid within terms. ' 8, Signature or In l is anywhere on this sheet constitutes agreement to all terns heroin, e. In consideration of Chambers Truss extending credit for this materiel the undersigned unconditionally guarantees payment when due of any and all Indebtedness owed to Chambers Truss by any entity receiving material and the undersigned agrees to pay such Indebtedness Including attorneys fees, If default In payment fir material be made by the recipient 1. 10. In the event of any litigation concerning INS agreament,4he items furnished hereunder or payments referred to herein, the, parties agree that the sole venue for any such action will be Saint Lucie County, Florida.. 11. Design responsitillit es are per "National Standard And Recommended Guldellnes On Responsibilities For Construction Using Metal Plate Connected Wood Trusses ANSIRPVWTCA 4 - 2002- DATED SIGNED -, FOR TITLE ' Aspeaderbarmaybe reggifredper"BCSI 1-03"tD pnaIont Idury& damago. Multiple ply trusses must be fastened together per engineering before they are set failure to do so can resultdn roof collapse. temporary and permanent bracing are required and can save life and property and is the responsibility of the truss erector. 'Study the contents of the lnforrnatlon packet included on delivery before setting trusses. Tiiaafes must be set and txacac7 per design m ptovent inJury &damage. Trusses must be sot plumb and square Do notset bunks or stack of plywood, roofing material or any other Concentrated loads on trusses, this can cause collapse. DO NOT SET TRUSSES USING THIS TA Your ` USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES 1 CHAMBERS TRUSS INC 3106 Oleander Avenue Fort Pierce; Florida 34982-6423 800-551-5932 Fort Plerce 772.465-2012 Fax 772.465.8711 Vero Beach 7JI-5R9-2012 Stuart 772-2863302 ' Th — rtect s or Architect's representative's shop drawing approval is NOT a "doubia chock",of the contractor. The contractor shall remain responsible for. checking field measurlannents and other construction criteria„ 4rchite!ct's wocovers ge»grail radf shape, review off t (rugs strapping,.andllloading on ar ucture from gravely and uplift loads and their re live locations. APProved By id, Xf Date: t3raden A Braden A.LA. P.A. 92.0/93.2MITEK 4.2 DESIGN CRITERIA County SAINT LUCIE Building Department ST LUCIE COUNTY Wind Design Criteria ASCE 7-2010 Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10 aRoofing Material Shingle or Shake «r`I Loading in PSF Roof R.D.L. w Top Chord Live 20 w I o I Top Chord Dead 7 4.2 L $� Bottom Chord Live 10 Non -Concurrent o c Bottom Chord Dead 10 3 TOTAL Load 37 7.2 Duration Factor 1.25 � Wind Speed 165mph y Top Chord C.B. Sheeting by builder. H Bottom Chord C.B. Sheeting by builder. t? Highest Mean Height 15'-0" Building Type ENCLOSED Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2017 K.U.L.=mesuainin Ueaa LOBO t-.b.=kxonrinUOUS braCtn Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of' the Buildino Designer and/or Engineer of Rerx4rd LLChambers Truss Inc. Drawing Name: M11392 Scale: 1/4 - 1' UJ82 total trusses, 15 different trusses. MI 4: RLC ACAD: RLC Reviewed By: Date:10/07/15 vi Re sed:0 2 3/ 1/18 ' I V J FOR Revised: 3/05/2020 -- yam_ 14'4" _--- 6'-4" 14'-4" �FIEVIEW OPWYNNE BUILDING CORP. - - cooE CO Any CLOU'SED AREAS ARE OF �� Sal. LUCIE N-gDESCRIPTION: / SPECIAL CONCERN & MUST BE t PORCHLEFT WINDSOR CHECKED CAREFULLY & MAY �Q PAGE 1of1CUSTOMER INITIALS EACH PAGE 770�S� t INDICATE DEVIATION FROM �__�� `._ PLANs',,, 15 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT M1 1392J� �G orfti � milli 11,1111111 1 1 1 1 I 1 1 1a,INS 11 i' 1!!! I _ 41111111 .— INSa�XXXIII��������_ _ NO SRI' INS `0110 1� MIN t\® INVERTEDWig B.C. PANNEL. w\r WEBS AT CENTER ... 108 0 ON M �al®la®ICI®I®I®1�81®I�li�l8�l�l�l®I®I I®I MiTek' RE: M11392 THE WINDSOR Site Information: Customer: Wynne Dev Corp Lot/Block: Address: unknown City: St. Lucie County Project Name: M11392 Model: THE WINDSOR Subdivision: State: FL MiTek USA, Inc. 6904 Parke East Blvd. Tampa, FL 33610-4115 General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 15 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 2 T19781804 Al 10/9/2020 FILE COPY 3 T19781805 A2 10/9/2020 4 T19781806 A3 10/9/2020 5 T19781807 A4 10/9/2020 6 T19781808 A5 10/9/2020 7 T19781809 ATA 10/9/2020 8 T19781810 B 10/9/2020' 9 10 T19781811 T19781812 BHA GRA 10/9/2020 10/9/2020 REVIEWED FOR 11 T19781813 J 1 10/9/2020 1 A w, //++ COMPLIANCE COMPLIANCE 12 T19781814 J3 10/9/2020 CODE ST, LUCIE COVNW 14 T19781816 J7 10/9/2020 15 T19781817 KJ7 10/9/2020 BOCC This item has been electronically signed and sealed by Albani, Thomas using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision ,`���� t i ��� based on the parameters provided by Chambers Truss. ��� BPS A• A� Truss Design Engineers Name: Albani, Thomas V O B i� My license renewal date for the state of Florida is February 28, 2021. <�.••�,�C' E N SF•' 9.L� ��'. Florida COA: 6634 No 39380 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the judsdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. :-33 STATE O F ' 44/ � Thomas A. Albani PE No.39380 MITek USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 October 09, 2020 1 of 1 Albani, Thomas Job Truss Truss Type Qty WINDSORT19781803 M11392 A HIP 1 [W7THE Reference o tional lA ranwnis i rugs, nw., run rrerce, rL tl.Z4U s mar u zudu mi IeK mousineS, Inc. IUe mar z4 iz:b4:Ut zuzu rage 1 ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-KTRK2jb7uXlhmgejamLw33G2phzq_UFBTsBBV6zXIH_ 1-0-0 6-1 -1 9-0-0 14-11-0 20-2-13 26-0-0 28-1-2 35-0-0 6-0- -0-0 6-10-14 2-1-2 5-11-0 5-3-13 5-9-3 2-1-2 6-10-14 0-0 4.00 12 08 = 2x3 II 3x6 = 4x4 = 4x8 = 2x3 2x3 4 26 5 6 7 27 8 9 Scale=1:60.5 17 16 15 14 13 12 3x4 — 3x4 = 3x6 — 6x8 = 3x4 = 3x6 — 3x4 = 3x5 — 9-M 35-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017rrP12014 CSI. TC 0.57 BC 0.47 WB 0.94 Matrix -MS DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) Vdefi L/d 0.42 12-23 >572 240 0.37 12-23 >659 180 0.03 10 n/a n/a PLATES GRIP MT20 244/190 Weight: 161 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purling. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-5-1 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 15=0-8-0, 10=0-8-0 Max Horz 2=-97(LC 10) Max Uplift 2=-235(LC 12), 15=-1439(LC 12), 10=-799(LC 12) Max Grav 2=467(LC 17), 15=1596(LC 1). 10=685(LC 22) FORCES. (lb) -Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-639/108, 34=396/0, 4-5=-967f776, 5-7=967/776, 7-8=454/938, 8-9=-1009/1884, 9-1 0=-1 265/2154 BOT CHORD 2-17=0/652, 15-17=0/430, 14-15=-704/454, 12-14=-15861938, 10-12=-1971/1174 WEBS 3-17=-372/461, 4-17=272/451, 4-15=1087/1002, 5-15=336/386, 7-14=-766/399, 8-14=-580/997, 8-12=-958/447, 9-12=358/600, 7-15=-1329/2190 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 9-0-0, Exterior(2) 9-0-0 to 13-11-6, Interior(1) 13-11-6 to 26-0-0, Exterior(2) 26-0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone; porch right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Provide adequate drainage to prevent water ponding. electronically Signed and 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. sealed by Alban!, Thomas, PE 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide using a Digital Signature. g 9 9 Will fit between the bottom chord and any other members. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 235 lb uplift at joint 2, 1439 lb uplift at Printed copies of this joint 15 and 799 lb uplift at joint 10. document are not Considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5119M20 BEFORE USE. Design valid for use only with M1Tek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not Nat a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall building design. Bradng Indicated Is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type oty Ply T19781804 M11392 Al SPECIAL 1 1 �THEWINDSOR Job Reference o tional Chambers Truss, Inc., tort tierce, tL 8.240 s Mar 9 2020 MiTek Industries, Inc. TUB Mar 24 12:54:08 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-of?iF3blfgtYOgDv7Us9cGoCh5CAjz5KiVwkOzzXjGz 1-0-0 8-6-0 1111 14-91 19.8-14 24-0-0 27 4-7 35-0-0 6-0- -0-0 8-6-0 2-6-0 3-9-0 4-11-14 43-2 3-4-7 7-7-9 -0-0 Scale=1:61.3 4.00 12 3x6 = 9.a \\ 5x6 = 13 12 3x5 = 5x8 MT18HS = 3x4 = 6 22 2.00 12 5x8 MT18HS = 3x12 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC20171TPI2014 CSI. TC 0.63 BC 0.91 WB 0.77 Matrix -MS DEFL. in (loc) Udefi L/d Vert(LL) 0.75 11-12 >563 240 Vert(CT) -1.21 11-12 >348 180 Horz(CT) 0.35 9 n/a n/a PLATES MT20 MT18HS Weight: 155 lb GRIP 244/190 244/190 FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-7-7 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-117(LC 10) Max Uplift 2=-825(LC 12), 9=-825(LC 12) Max Grav 2=1349(LC 1), 9=1349(LC 1) FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3209/2102, 3-4=3006/2024, 4-5=3022/2080, 5-6=3022/2080, 6-7=-4643/2994, 7-8=-5324/3364, 8-9=-5751/3700 BOT CHORD 2-13=-1883/3007, 12-13=-1591/2657, 11-12=-2456/3908, 9-11=-3442/5478 WEBS 3-13=425/410, 4-13=354/571, 4-12=3621617, 5-12=-269/279, 6-12=-10341712, 6-11=-373/892, 7-11=-897/1523, 8-11=404/435 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces $ MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. This item has been 4) All plates are MT20 plates unless otherwise indicated. electronically Signed and 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Sealed by Albani, Thomas, PE 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide using a Digital Signature. will fit between the bottom chord and any other members. 7) Bearing atjoint(s) 9 considers parallel to grain value using ANSI1TPI 1 angle to grain formula. Building designer should verify Printed copies of this capacity of bearing surface. document are not considered 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at signed and sealed and the joint 9. signature must be verified on any electronic copies. Thomas A. Aibani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 6/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall �- building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781805 M11392 A2 SPECIAL 1 1 _Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:09 2020 Page 1 ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-HsZ4SPcOQ87P?zo5hBO08ULMuVYnSPxUx9glY?zXjGy 1-0-0 8-6-0 13-0-0 14-91 22-0-0 27-4-7 35-0-0 6-0- -0-0 8.6-0 4.6-0 1-9-0 7-3-0 5-0-7 7-7-9 -0-0 Scale = 1:61.3 5x6 3x4 = 5x8 = 3x6 = 4.00 12 4 21 5 22 6 12 3x4 = 5x8 = 2.00 12 14-9-0 22-M LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Cade FBC2017rTP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 8=0-8-0 Max Horz 2=136(LC 11) Max Uplift 2=-825(LC 12), 8=-825(LC 12) Max Grav 2=1349(LC 1), 8=1349(LC 1) 3x12 zz CSI. DEFL. in (Icc) Vdefi Lid PLATES GRIP TC 0.66 Vert(LL) 0.72 10 >585 240 MT20 244/190 BC 0.95 Vert(CT)-0.9410-19 >447 180 MT18HS 244/190 WB 0.86 Horz(CT) 0.34 8 n/a n/a Matrix -MS Weight: 160 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc pudins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3211/2064, 3-4=3017/1998, 4-5=2580/1800, 5-6=3379/2225, 6-7=5242/3250, 7-8=-5759/3665 BOT CHORD 2-13=-1847/3008, 12-13=-1403/2418, 11-12=-1552/2629, 10-11=1990/3441, 8-10=-3410/5485 WEBS 3-13=-420/418, 4-13=-427/688, 4-12=337/551, 5-12=-777/605, 5-11=-465/925, 6-11=-391/277, 6-1 0=-1 318/2268, 7-10=-503/530 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 8 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 8. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verily the applicability of design parameters and properly Incorporate this design Into the overall bulding design. Bracing Indicated Is to prevent buckling of Individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and properly, damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPl1 Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safelylntormadon avallable from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type Oty Ply THEWINDSORT19781806 Fsrpurs=sc M11392 A3IAL 1 1 Jab Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:10 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-127SgidOBS7Gd7NIFvvehhuYXvu2Bsnd9pPr4RZ)gGx 1-0 0 8-6-0 15-0-0 TV24-6-8 27.4-7 35-0-0 1-0-0' 8-6 0 6-6-0 5-0-0 4-6-8 2-9-15 7-7-9 -0-0 �1 4.00 12 5x6 = 45 = Scale=1:62.3 14 13 3x5 = 24 II Sx6 = 3x12 = 2.00 12 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017fTP12014 CSI. TC 0.60 BC 0.95 WB 0.83 Matrix -MS DEFL, in (loc) Vdefl Ud Vert(LL) 0.73 11 >572 240 Vert(CT) -0.97 11-20 >432 180 Horz(CT) 0.36 9 n/a n/a PLATES MT20 MT18HS Weight: 160 lb GRIP 244/190 244/190 FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 7-12 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-155(LC 10) Max Uplift 2=-825(LC 12), 9=-825(LC 12) Max Grav 2=1349(LC 1), 9=1349(LC 1) FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-3256/2031, 4-5=-2426/1588, 5-6=-2680/1790, 6-7=-2829/1832, 7-8=5320/3257, 8-9=-5720/3564 BOT CHORD 2-14=-1817/3048, 13-14=-1817/3048, 12-13=-1258/2274, 11-12=2935/5103, 9-11=3302/5445 WEBS 4-14=0/329, 4-13=-897/636, 5-12=-316/661, 6-12=-317/616, 7-12=-2727/1643, 7-11 =-1 07211939, 8-11 =-390/391 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Provide adequate drainage to prevent water ponding. electronically signed and 4) All plates are MT20 plates unless otherwise indicated. Sealed by Albani, Thomas, PE 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. • using a Digital Signature. 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Printed will fit between the bottom chord and any other members. Copies of this 7) Bearing atjoint(s) 9 considers parallel to grain value using ANSIrrPI 1 angle to grain formula. Building designer should verify document are not considered capacity of bearing surface. signed and sealed and the 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at signature must be verified joint 9. on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 —--------------- ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not ��®® a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall faRii�- building design. Bracing indicated Is to prevent buckling of individual truss web andfor chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP/1 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Ply T19781807 M11392 A4 SPECIAL �Ql:y 1 1 �THEWINDSOR Jab Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:112020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-DEhgt5eexIF7FHyUpcQtEvQjTIDGwGhnOT90duzXjGw 1-0-0 8.6-0 14-9-0 17-0-0 18 0 24-6-8 2717 35.0-0 6-0- -0-0 8-6-0 6-3.0 2-3-0 -0-0 6-6-8 2-9-15 7-7-9 -0-0 �1 4.00 12 2x3 5x6 = 46 = 6 7 Scale = 1:62.3 16 15 6x10 3x5 = 2x3 II 5x8 = 3x12 = 2.00 12 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TPI2014 CSI. TC 0.59 BC 0.95 WB 0.98 Matrix -MS DEFL. in Vert(LL) 0.80 Vert(CT) -1.05 Horz(CT) 0.39 (loc) Udefl Ud 13 >528 240 13 >400 180 11 n/a n/a PLATES MT20 MT18HS Weight: 172 lb GRIP 244/190 244/190 FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-6-14 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 8-14 REACTIONS. (size) 2=0-8-0, 11=0-8-0 Max Horz 2=-175(LC 10) Max Uplift 2=-825(LC 12). 11=-825(LC 12) Max Grav 2=1349(LC 1). 11=1349(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3253/1989, 3-5=2435/1560, 5-6=-2399/1639, 6-7=-2217/1501, 7-8=-2380/1519, 8-10=-5361/3228,10-11=-5716/3480 BOT CHORD 2-16=-1776/3045, 15-16=-1776/3045, 14-15=-1117/2168, 13-14=-2920/5154, 11-13=-3232/5441 WEBS 3-16=0/334, 3-15=-882/614, 5-15=-238/254, 7-14=-163/427, 6-14=-309/604, 6-15=-315/409, 8-14=-3146/1901, 8-13=-1034/1946, 10-13=-343/333 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) Provide adequate drainage to prevent water ponding. electronically Signed and 4) All plates are MT20 plates unless otherwise indicated. Sealed by Albani, Thomas, PE 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' using a Digital Signature. 6) This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. Printed Copies Of this 7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify document are not considered capacity of bearing surface. signed and Sealed and the 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at signature must be verified joint 11. on any electronic Copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 --.......... ----... .................. ....__.._.._ ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 611912020 BEFORE USE. - — - Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall�a building design. Bracing Indicated is to prevent buckling of individual truss web andror chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Oty Ply WINDSOR tTHE T19781808 M11392 A5 SPECIAL 16 1 ob Reference o floral Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:13 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-9dpbinfuTNVrUb6twl SLJKWOV6vFOEp3meVhmzXjGu 1-0-0 8.6-0 14-9-0 17-6-0 24.6-8 27-4-7 35-0-0 6-0- -0-0 8 6-0 6 3-0 2-9-0 7-0-8 2-9-15 7-7-9 -0-0 �1 d 3x5 = Scale = 1:60.3 5x8MT1BHS 11 4.00 12 14 13 2x3 II 5x10 = LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TP12014 LUMBER - TOP CHORD 2x4 SP M 31 'Except' 14,8-11: 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 6-12: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 10) Max Uplift 2=-825(LC 12), 10=-825(LC 12) Max Grav 2=1349(LC 1), 10=1349(LC 1) 302 2.00 12 CS]. DEFL. in (loc) Udefl L/d PLATES GRIP TC 0.81 Vert(LL) 0.80 12-13 >526 240 MT20 244/190 BC 0.92 Vert(CT)-1.2812-13 >329 180 MT18HS 244/190 WB 0.74 Horz(CT) 0.36 10 n/a n/a Matrix -MS Weight: 160 lb FT = 20% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 6-12 FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3247/2112, 3-5=-2449/1679, 5-6=2397/1763, 6-7=5452/3624, 7-9=5398/3482, 9-10=-5732/3689 BOT CHORD 2-14=-1865/3040, 13-14=-1865/3040, 12-13=-1223/2137, 10-12=3431/5459 WEBS 3-14=0/303, 3-13=8611619, 5-13=-216/264, 6-13=-300/527, 6-12=-2247/3526, 7-12=-323/388, 9-12=-321/306 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterlor(2) 17-6-0 to 21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members, with BCDL = 10.0psf. 6) Bearing atjoint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at joint 10. ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS177P/1 Quality Criteria, OSB-89 and BCSI Building Component Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 I' 1 I�, 0 This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33810 Date: March 24,2020 Nat MiTek' 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type Oty Ply THE WINDSOR T19781809 M11392 ATA COMMON 5 1 Job Reference (optional) mhers I russ, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:14 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-dpMzW7gWEgdi61g3UkzarX2EkWJA7jTD4RN3DCzXjGt 1-0-0 8-4-0 12-11-0 17 6-0 22-1-0 26-8-0 35-0-0 6-0- 008.4.0 4-7-0 4-7- 4-7-0 4-7-0 B-4-0 1-") �1 6 4.00 12 45 = Scale = 1:59.5 17 '- 15 "" "' 14 "' 12 3x6 — 2x3 II 4x6 = 3x8 = 2x3 II 3x6 = 3x8 = 4z6 = LOADING (psi) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017frP12014 CSI. TC 0.59 BC 0.68 WB 0.59 Matrix -MS DEFL. in (loc) Udefl Ud Vert(LL) 0.33 14-15 >999 240 Vert(CT) -0.64 14-15 >652 180 Horz(CT) 0.13 10 n/a n/a PLATES GRIP MT20 244/190 Weight: 166 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-1-15 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 5-2-15 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-M Max Horz 2=-179(LC 10) Max Uplift 2=-775(LC 12), 10=-775(LC 12) Max Grav 2=1399(LC 1), 10=1399(LC 1) FORCES. (lb) -Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3404/1963, 3-5=2807/1637, 5-6=-2801/1739, 6-7=-2801/1739, 7-9=2807/1637, 9-10=-3404/1963 BOT CHORD 2-17=-1724/3188,15-17=-1724/3188,14-15=-966/2053,12-14=-1739/3188, 10-12=-1739/3188 WEBS 6-14=-560/968, 9-14=-681/524, 6-15=-560/968, 3-15=-681/524 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Extedor(2) 17-6-0 to 21-M, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and farces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 This item has been 3) 100.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart. electronically Signed and 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Sealed by Albani, Thomas, PE 5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide a Digital Signature. using g 9 will fit between the bottom chord and any other members, with BCDL = IO.Opsf, 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775lb uplift at joint 2 and 775 lb uplift at Printed copies of this joint 10. document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cart 6634. 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5I1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not �• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall r building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI7TP/t' quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Infonnaflon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 1 N d Job Truss Truss Type City Ply THE WINDSOR T79781810 M11392 B COMMON 2 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:15 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-5OwLjShB7_ITjuFF2SVpOlbSRwk4sA4MJ57cmfzXjGs 1-0-0 8-3-5 14-0-0 17-6-0 21.0-0 26 8 11 35-0-0 6-0 -0-0 8-3-5 5 8-11 3.6.0 3 6-0 5 8-11 8-3-5 0-0 Scale = 1:59.3 �1 4.00 12 3x6 = 3x4 = 2x3 II 3x6 = 3x4 = 3x4 = 3x6 = 2x3 II 3x4 = 1 � Io ' B-3-5 5.8-11 7-0-0 5-8-11 8-3-5 Plate Offsets (X,Y)— [2:0-2-6,Edge), [6:0-3-0,Edge), [10:0-2-6,Edge) LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.34 Vert(LL) -0.11 14-15 >766 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.24 17-20 >715 180 BCLL 0.0 Rep Stress Incr YES WB 0.63 Horz(CT) 0.03 10 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MS Weight: 149 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=-179(LC 10) Max Uplift All uplift 100 lb or less at joint(s) except 2=-371(LC 12), 15=-453(LC 12), 14=-453(LC 12), 10=-371(LC 12) Max Grav All reactions 250 lb or less at joints) except 2=602(LC 1), 15=844(LC 17), 14=840(LC 18), 10=602(LC 1) FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-945/572, 5-6=181/256, 6-7=-181/258, 9-10=-945/574 BOT CHORD 2-17=-407/878, 15-17=-407/878, 12-14=-393/858, 10-12=-393/858 WEBS 3-17=-5/301, 3-15=819/591, 5-15=-277/325, 7-14=277/326, 9-14=-819/592, 9-12=-5/301 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2)-1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to This item has been 21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 electronically signed and 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. Sealed by Albani, Thomas, PE 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide using a Digital Signature. will fit between the bottom chord and any other members, with BCDL=10.Opsf. Printed copies of this 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2, 453 lb uplift at joint 15, 453 lb uplift at joint 14 and 371 lb uplift at joint 10. document are not Considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alberti PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of busses and truss systems, see ANSUTP/1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply THE WINDSOR T19781811 M11392 BHA BOSTON HIP 1 1 Job Reference o tlonal Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:17 2020 Page 1 I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-202688iPXb7HzCPe9tXHTAgmFjM 1 K3EfmPcjgxzXjGq 15-6-0 21.6-0 1-0.0 7.0.0 9-6-0 17-6-0 13.6-0 1 17-6-0 19.6-0 21-0-0 23-6-0 25-6-0 28-0-0 35-0-0 6-0-0 -0-0 7-0-0 2-6-0 2-0-0 2.0-0 0-0 1-6-0 2-0-0 2-0-0 7-6-0 2.0-0 2-0-0 2.6-0 7-0-0 -0-0 Scale =1:62A TOP CHORD MUST BE BRACED BY END JACKS, 4x4 = ROOF DIAPHRAGM, OR PROPERLY CONNECTE 4.00 12 PURLINS AS SPECIFIED. 57 15 58 17 56 12 /\ 59 3x6 bb a 518 5x12 =53 4 6 JX6 3 11 52 I \gym, 11 14 35 42 3x4 = 43 34 44 33 45 3x6 = 6x8 = 20 �6�3x45x12 16 19 1 15V 46 47 48 ' 2' 49 31 50 51 30 6x8 = 3x6 = LOADING (psi) SPACING- 2-0-0 CS1. DEFL. in (loc) Vdefi Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.51 Vert(LL) 0.13 35-38 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.54 Vert(CT) -0.16 35-38 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.65 Horz(CT) 0.04 28 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MS Weight: 208 Ib FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-3-13 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 WEBS 1 Row at midpt 3-33, 27-32 JOINTS 1 Brace at Jt(s): 11, 19, 16. 7, 23 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=179(LC 7) Max Uplift All uplift 100 Ib or less at joints) except 2=-565(LC 8), 33=-1269(LC 8), 32=-1017(LC 8), 28=-434(LC 8) Max Grav All reactions 250 Ib or less at joint(s) except 2=812(LC 17), 33=1825(LC 1), 32=1529(LC 1), 28=626(LC 1) FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1692/1103, 3-4=-105/259, 27-28=-11291710, 3-5=-441/520, 5-7=-436/514, 7-10=-436/514, 10-11=-436/514, 11-13=-436/514, 13-16=-436/514, 16-18=-436/514, 18-19=-436/514,19-21=-382/412,21-23=-382/412,23-25=-382/412,25-27=-387/418 BOT CHORD 2-35=-939/1572, 33-35=-909/1484, 32-33=-382/400, 30-32=-575/1004, 28-30=-568/1039 WEBS 3-35=-191/649, 27-30=0/451, 3-33=-2090/1523, 11-33=-810/782, 19-32=772/745, 27-32=-1484/1044,9-10=4631453,20-21=-462/454 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live toad nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 565 Ib uplift at joint 2, 1269 Ib uplift at joint 33, 1017 Ib uplift at joint 32 and 434 Ib uplift at joint 28. 8) Graphical puriin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 265 Ib down and 381 Ib up at 7-0-0, 158 Ib down and 206 Ib up at 9-0-12, 158 Ib down and 206 Ib up at 11-0-12, 158 Ib down and 206 Ib up at 13-0-12, 158 Ib down and 206 Ib up at 15-0-12, 158 Ib down and 206 Ib up at 17-0-12, 158 Ib down and 206 Ib up at 17-11-4, 158 Ib down and 206 Ib up at 19-11-4, 158 Ib down and 206 Ib up at 21-11-4, 158 Ib down and 206 Ib up at 23-11-4, and 158 Ib down and 206 Ib up at 25-11-4, and 158 Ib down and 206 Ib up at 27-11-4 on top chord, and 373 Ib down and 236 Ib up at 7-0-0, 69 Ib down at 9-0-12, 69 Ib down at 11-0-12, 69 Ib down at 13-0-12, 69 Ib down at 15-0-12, 69 Ib down at 17-0-12, 69 Ib down at 17-11-4, 69 Ib down at 19-11-4. 69 Ib down at 21-11-4. 69 Ib down at 23-11-4. and 6g Ib down at 25-11-4- and 69 Ih dnwn at 27-11-4 nn hntfnm rhnrd This item has been electronically signed and sealed by Alban!, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: e esign/selechon t) such connection devices) is the responsibility of others-- —'-"`---- �� ®V 2tfYQQie �i'd51gh ��)dieaElOrdF�,t0B4t$r8ppifelj-16 fimfocamfElhelima FBnfr=t7( ) a*bEacIaMBEFORE USE. DOjyBp+pWdrgpp evigt MITek8 connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not a irppg pygtgwy,@q�r@1sett�gtlpujldytg designer must verify the applicability of design parameters and property incorporate this design Into the overall r �- bui i esi n. r g Rrdi N1190 prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 March 24,2020 Job Truss Truss Type City Ply THE WINDSOR T19781811 M11392 BHA BOSTON HIP 1 1 Job Reference o t oval l TamDers 1 russ, Inc., Fort Fierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:17 2020 Page 2 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-202688iPXb7HzCPegtXHTAgmFjM1 K3EfmPcjgXzXjGq LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 36-39=-20, 1-3=-54, 3-15=-54, 15-27=54, 27-29=-54 Concentrated Loads (lb) Vert:35=-373(F) 30=-23(F) 42=-23(F) 43=-23(F)44=23(F) 45=-23(F) 46=-23(F)47=-23(F) 48=23(F) 49=-23(F) 50=-23(F) 51=-23(F) 52=-169(F) 53=-118(F) 54=-118(F) 55=-118(F) 56=-118(F) 57=-118(F) 58=118(F) 59=-118(F) 60=-118(F) 61=-118(F) 62=-1 1 8(F) 63=1 18(F) --- WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 511912020 BEFORE USE. Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and is for an individual building component, not ..... - ... - .... ... - .-....._.-_...._-...... — - a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall building design. Bracing Indicated Is to prevent budding of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, see ANSI/rP/f Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11392 GRA HIP 11b [HEWINDSORT19781812 Reference (optional) o.Z4U s mar y zuzu mt I eK mausmes, Inc. I ue Mar z4 1z:04:iu zuzu rage 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KK-_nAsZgkf3CG_CWZOHIZIYbl?yXOVouLyEj5gvQzXjGo 1-0-0 7-0-0 14-11-0 21-5-2 28-0.1 35-M 10 0-0 7-11-0 6-6-2 6-6-14 7-0-0 -0-0 5x12 MT18HS = 4.00 12 3x5 II 3x6 = 4x8 = 3 22 23 24 25 4 26 27 5 28 629 30 31 32 4x8 = 7 Scale = 1:60.3 1' � N a d as — p, — JO JI Jo J9 11 4V 41 3x4 = 2x3 11 3x6 = 5x14 = 3x4 = 46 = 2x3 11 3x5 = 35-M LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr NO Code FBC2017/rP12014 CsL TC 0.94 BC 0.67 WB 1.00 Matrix -MS DEFL. in (loc) Udefl Lid Vert(LL) 0.30 10-21 >792 240 Vert(CT) -0.30 10-12 >812 180 Horz(CT) 0.09 8 n/a file PLATES MT20 MT18HS Weight: 153 lb GRIP 244/190 244/190 FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-9-5 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-6-8 oc bracing. WEBS 2x4 SP No.3 *Except* WEBS 1 Row at midpt 6-13 4-13: 2x6 SP No.2 2 Rows at 1/3 pis 3-13 REACTIONS. (size) 2=0-8-0, 13=0-8-0, 8=0-8-0 Max Horz 2=-78(LC 6) Max Uplift 2=-448(LC 8), 13=-2442(LC 8), 8=-1159(LC 8) Max Grav 2=755(LC 17), 13=3223(LC 1), 8=1225(LC 18) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-15341729, 3-4=105211347, 4-6=105211347. 6-7=1946/1834, 7-8=2978/2565 BOT CHORD 2-15=-586/1423,13-15=-596/1464,12-13=-1710/1946,10-12=-2359/2830, 8-10=-2329/2789 WEBS 3-15=-159/733, 3-13=-2917/1869, 4-13=-848/801, 6-13=3504/3050, 6-12=-430/666, 7-12=-940/731, 7-10=489/690 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf, BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eaye=5ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. This item has been 4) All plates are MT20 plates unless otherwise indicated. electronically Signed and 5) This truss has been designed fora 10.0 psf bottom chord live load nonconcurrent with any other live loads. sealed by Albani, Thomas, PE 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide using Digital Signature. g a g. 9 will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 448 lb uplift at joint 2, 2442 lb uplift at Printed copies of this joint 13 and 1159 lb uplift at joint 8. document are not considered 8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 203 lb down and 329 lb up at signed and sealed and the 7-0-0, 90 lb down and 155 lb up at 9-0-12, 90 lb down and 155 lb up at 11-0-12, 90 lb down and 155 lb up at 13-0-12, 90 lb down signature must be verified and 155 lb up at 15-0-12, 90 lb down and 155 lb up at 17-0-12, 90 lb down and 155 lb up at 17-114, 90 lb down and 155 lb up at 19-11-4, 90 lb down and 155 lb up at 21-114, 90 lb down and 155 lb up at 23-11-4, and 90 lb down and 155 lb up at 25-114, and on any electronic copies. 203 lb down and 329 lb up at 28-0-0 on top chord, and 452 lb down and 263 lb up at 7-0-0, 63 lb down and 3 lb up at 9-0-12, 63 lb Thomas A. Albani PE No.39380 down and 3 lb up at 11-0-12, 63 lb down and 3 lb up at 13-0-12, 63 lb down and 3 lb up at 15-0-12, 63 lb down and 3 lb up at MiTek USA, Inc. FL Cart 6834 17-0-12, 63 lb down and 3 lb up at 17-114, 63 lb down and 3 lb up at 19-114, 63 lb down and 3 lb up at 21-11-4, 63 lb down and 6904 Parke East Blvd. Tampa FL 33610 3 lb up at 23-11-4, and 63 lb down and 3 lb up at 25-11-4, and 452 lb down and 263 lb up at 27-11-4 on bottom chord. The Date: design/selection of such connection device(s) is the responsibility of others. March 24,2020 9) in the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B) ,&LQ t1AICASEJ%si5tamdaarbrs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 511912020 BEFORE USE. DQ' Mt?AWdrtl@RBaW2a2h MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component• not a truss system. Befddre se, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall�- buiiding design. Bracing Indicated is to prevent buckling of individual truss web andlor chord members only. Additional temporary and permanent bracing MiTek♦ Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSf7rP11 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute. 2670 Crain Highway, Suite 203 Waldod, MD 20601 Tampa, FL 36610 Job Truss Truss Type my Ply THE WINDSOR T19781812 M11392 GRA HIP 1 1 Job Reference (optional) uss, orc., run Fierce, rL 8.241) s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:19 2020 Page 2 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYbl?yXOVouLyEj5gvQz)(j*Go LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=-54, 3-7=54, 7-9=-54, 16-19=-20 Concentrated Loads (lb) Vert: 3=-147(B) 7=147(B) 15=452(B) 13=40(B) 4=-90(B) 10=-452(B) 22=-90(B) 23=90(1]1) 24=-90(B) 26=-90(B) 27=-90(B) 28=-90(B) 30=-90(B) 31=-90(B) 32=-90(B) 33=-10(B) 34=40(B) 35=40(B) 36=-40(B) 37=40(B) 38=40(B) 39=-40(B) 40=-40(B) 41=40(B) - —....._..__..... _.._...... __....... ... -------....--- WARNING • Veriy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5I7912020 BEFORE USE. -- Design valid for use only with MITek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not HV 1• a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P11 Quality Criteria, DSB-09 and BCS/ Building Component Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 6904 Parke East Blvd. Tampa, FL 36610 Job Truss Truss Type city Ply THE WINDSOR T19781813 M11392 J1 MONO TRUSS 8 1 Job Reference o tional s Truss. inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:19 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KK-_nAsZgkf3CG_CWZOHIZIYblBwXAho7vyEj5gvOzXjGo 1-0-0 1-0-0 1-0-0 1-0-0 3x4 = Scale = 1:6.1 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 5 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.02 Vert(CT) -0.00 5 >999 180 BCLL 0.0 Rep Stress Incr YES WS 0.00 Horz(CT) 0.00 4 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MP Weight: 5 Ib FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 1-0-0 oc puriins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=48(LC 12) Max Uplift 3=-4(LC 9), 2=140(LC 12) Max Grav 3=11(LC 17), 2=118(LC 1), 4=17(LC 12) FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl.. GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at joint 2. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 A WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 141II.7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overalls building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSLITP11 quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type city Ply T19781814 M11392 J3 MONO TRUSS 8 1 �THEWINDSOR Job Reference (optional) Chambers Truss, inc., Fort Fierce, t-L 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:20 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-SzkEmAIHgWOrgg8Dq74_5oIMZxUHXa95SNgNRszXjGn 3-0-0 1-0-0 3-0-0 Scale = 1:9.4 3x4 = LOADING (psf) SPACING- 2-0-0 CS1. DEFL. in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TIC 0.18 Vert(LL) 0.01 4-7 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.19 Vert(CT) -0.01 4-7 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC20171TP12014 Matrix -MP Weight: 11 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 3-M oc purlins. BOT CHORD 2x4 SP ND.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=85(LC 12) Max Uplift 3=-54(LC 12), 2=-147(LC 12), 4=-4(LC 12) Max Grav 3=64(LC 1), 2=173(LC 1), 4=50(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 2-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide Will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint 2 and 4 lb uplift at joint 4. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 A WARNING -Verily design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall Sal - building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery. erection and bracing of trusses and truss systems, see ANSLITP11 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type city Ply THE WINDSOR T79781815 M11392 J5 MONO TRUSS 8 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 3x4 = 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:21 2020 Page 1 ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-wAHc_WlvbgWjRpjPOibDeOrOoKiYG1 PFh1 awzlzXjGm Scale = 1:12.7 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (IDc) Vdefi Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.73 Vert(LL) 0.07 4-7 >863 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.70 Vert(CT) -0.06 4-7 >964 180 BCLL 0.0 ' Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017[rP12014 Matrix -MP Weight: 17 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=123(LC 12) Max Uplift 3=-104(LC 12), 2=-177(LC 12), 4=-9(LC 12) Max Grav 3=115(LC 1), 2=243(LC 1), 4=87(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Intedor(1) 2-6-0 to 4-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at joint 2 and 9 lb uplift at joint 4. This item has been electronically signed and sealed by Alban!, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6834 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ®WARNING - Verlfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not e truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall r building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/7P11 Quality Criteria, DSX89 and BCS/ Building Component 6904 Parke East Blvd. Safety lnformadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply THE WINDSOR T19781816 M11392 J7 MONO TRUSS 24 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:212020 Page 1 ID:_kfiGCA6bx7j2SylHDXFw7ye3KX-wAHc_Wlvbq iRpjPOibDeOrSnKmPG1PFh1awzlzXjGm 1-0-0 7-0-0 1-0-0 7-" Scale: 3/4'=1' 3x4 = Plate Offsets (X,Y)— [2:0-1-14,Edge] LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.47 Vert(LL) 0.17 4-7 >494 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.39 Vert(CT) -0.19 4-7 >447 180 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 23 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Hors 2=161(LC 12) Max Uplift 3=-153(LC 12), 2=-211(LC 12). 4=-12(LC 12) Max Grav 3=165(LC 1), 2=315(LC 1), 4=125(LC 3) FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 6-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 3, 211 lb uplift at joint 2 and 12 lb uplift at joint 4. This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Alban! PE No.39380 MiTek USA, Inc. FL Cent 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ---- ..... . - ----- --------..-... WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall HV (- building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek* is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP/1 Duality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type City Ply �THEWINDSOR T19781817 M11392 KJ7 MONO TRUSS 4 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:64:22 2020 Page 1 ID:_kflGCA6bx7j2Sy1HDXFw7ye3KX-OMr BsmXM7eZ3zIbyQ7SADNhnk9g?RvOwhJUWlzXjGI i -1-5-0 6-8-12 9-10-1 1-5-0 6-8.12 3-1-5 Scale=1:20.6 3x4 = " 5 3x4 = LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) -0.04 7-10 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.26 Vert(CT) -0.08 7-10 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.24 Horz(CT) 0.01 5 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MS Weight: 38 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-11-5, 5=Mechanical Max Horz 2=192(LC 8) Max Uplift 4=-131(LC 8), 2=-262(LC 8), 5=238(1_C 8) Max Grav 4=156(LC 13). 2=379(LC 1), 5=461(LC 1) FORCES. (lb) -Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-838/366 BOT CHORD 2-7=487/798, 6-7=487/798 WEBS 3-7=0/307, 3-6=-920/561 NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf, h=15ft; B=70ft; L=35ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 4, 262 lb uplift at joint 2 and 238 Ito uplift at joint 5. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-2=-54 Trapezoidal Loads (plf) Vert: 2=0(F=27, B=27)-to-4=-133(F=-39, B=-39), 8=0(F=10, B=10)-to-5=-49(F=-15, B=-15) This item has been electronically signed and sealed by Albani, Thomas, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Thomas A. Albani PE No.39380 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: March 24,2020 ® WARNING -Verify design parameters end READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall�a building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVrP/f quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols Numbering System General Safety Notes PLATE LOCATION AND ORIENTATION Center plate on joint unless x, y offsets are indicated. 6-4-8 dimensions shown In ft-in-sixteenths (Drawings not to scale) Failure to Follow Could Cause Property Damage or Personal Injury Dimensions are in ft-in-sixteenths. 1. Additional stability bracing for truss system, e.g. Apply plates to both sides of truss 1 2 3 diagonal or X-bracing, is always required. See BCSI. and fully embed teeth. TOP CHORDS 2. Truss bracing must be designed by an engineer. For y c1-2 c2-3 wide truss spacing, individual lateral braces themselves may require bracing, or alternative Tor I N WEBS 4 00 _ 3 3 O bracing should be considered. 3. Never exceed the design loading shown and never stack materials on inadequately braced trusses. U dab = o U 4. Provide copies of this truss design to the building O o ~ designer, erection supervisor, property owner and For 4 x 2 orientation, locate c7-8 c6.7 css all other interested parties. plates 0- yiO from outside BOTTOM CHORDS 5. Cut members to bear tightly against each other. edge of truss. 8 7 6 5 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE locations are regulated by ANSI/rPI 1. required direction of slots In AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO 7, Design assumes trusses will be suitably protected from connector plates. THE LEFT. the environment in accord with ANSIfTPI 1. "Plate location details available in MITek 20/20 CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. 8. Unless otherwise noted, moisture content of lumber shall not exceed 19% at time of fabrication. software or upon request. 9. Unless expressly noted, this design is not applicable for PRODUCT CODE APPROVALS use with fire retardant, preservative treated, or green lumber. PLATE SIZE [CC -ES Reports: 10. Camber is a non-structural consideration and is the The first dimension is the plate responsibility of truss fabricator. General practice is to 4 x 4 width measured perpendicular ESR-1311, ESR-1352, ESR1988 camber for dead load deflection. to slots. Second dimension is ER-3907, ESR-2362, ESR-1397, ESR-3282 11. Plate type, size, orientation and location dimensions the length parallel to slots. indicated are minimum plating requirements. LATERAL BRACING LOCATION 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. Indicated by symbol shown and/or by text in the bracing section of the Trusses are designed for wind loads in the plane of the truss unless otherwise shown. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. output. Use T or I bracing if indicated. Lumber design values are in accordance with ANSI/TPI 1 14. Bottom chords require lateral bracing at 10 ft. spacing, or less, if no ceiling is installed, unless otherwise noted. section 6.3 These truss designs rely on lumber values BEARING established by others. 15. Connections not shown are the responsibility of others. 16. Do not cut or alter truss member or plate without prior Indicates location where bearings approval of an engineer. (supports) occur. Icons vary but reaction section indicates joint © 2012 MiTekO All Rights Reserved 17. Install and load vertically unless indicated otherwise. 0 number where bearings occur. Min size shown is for crushing only. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. Industry Standards: im I 19. Review all portions of this design (front, back, words ANSI/TPI1: National Design Specification for Metal and pictures) before use. Reviewing pictures alone is not sufficient. Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. 0 20. Design assumes manufacture in accordance with BCSI: Building Component Safety Information, MiTek ANSI/rPI 1 Quality Criteria. Guide to Good Practice for Handling, Installing & Bracing of Metal Plate 21.The design does not take into account any dynamic Connected Wood Trusses. MITek Engineering Reference Sheet: Mll-7473 rev. 5/19/2020 or other loads other than those expressly stated.