HomeMy WebLinkAboutEnergy CodeFORM R405-2017
'FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT
Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE -arl��QJ Sg
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
Permit Number:
Owner: WYNNE BUILDING CORP.
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1718.3 sgft.).
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1478.30 ft2
b. Frame - Wood, Adjacent
R=11.0 240.00 ft2
3. Number of units, if multiple family 1
c. N/A
.
R= ft2
4. Number of Bedrooms 1
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1336.0 sgft.)
Insulation Area.
a. Under Attic (Vented)
R=30.0 1306.00 ft2
6. Conditioned floor area above. grade (W) 1306
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(128.9 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 120
a. U-Factor: Sgl,. U=1.02 76.04 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.03 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
29.0 SEER:14.00
c. U-Factor: Sgl, U=1.02 12.85 ft2
SHGC: SHGC=0.26
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
27.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 4.701 ft.
Area Weighted Average SHGC: 0281
14. Hot.water systems
8. Floor Types (1306.0 sgInsulation Area
a. Electric Tankless
Cap: 1 gallonsft.)
a. Slab -On -Grade Edge Insulation R=0.0 1306.00 ft2
b. Conservation features
EF: 0.600
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
None .
Total Proposed Modified Loads: 43.81
Glass/Floor Area: 0.099
PASS
Total, Baseline Loads: 45.95
hereby certify that the plans and specifications covered by
Review of the plans and
this calculation are in compliance with the Florida Energy
specifications covered by this
S: R. 0
Code.
_calculation indicates compliance
;' =.ra 110
`
with the Florida Energy Code.2
PREPARED BY:
Before construction is completed
TA -
DATE: 4-28-2020
this building will be inspected for
compliance with Section 563.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes..
"
with the Florida Energy Co
OWNER/A��EKIT'
BUILDING OFFICIAL:
DATE: 'N
DATE:
- Compliance requires certification -by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with 11403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with 111402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R4022..4 2)VI E® FOR
FILE COPY CODEE COI4 PLIANCE
ST. -LUCIE .COUNTY
4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) CompliaF3qw P Page 1 of 5
FORM:R405-2017 INPUT 5UMMARY:CHECKLI5T REPORT
PROJECT
Title: WYNNE BUIDLING-THE CO Bedrooms: 1
Address Type:
Street Address
Building Type: User Conditioned Area: 1306
Lot #
Owner Name: WYNNE BUILDING CORP. Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING CORP. Rotate Angle: 180
Street:
THE COTTAGE
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
Design Temp
Int Design Temp
Heating
Design Daily Temp
Design Location TMY Site 97.5 %
2.5 %
Winter
Summer Degree
Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House .1306 10576.2
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
. Heated
1 MASTER BEDROO 234 1895.4 No
0
1
1
Yes
Yes
Yes
2 DEN 144 1166.4 No
0
1
Yes'
Yes
Yes
3 SINKAREA 42 340.2 No
0
1
Yes
Yes
Yes
4 CLOSET 63 510.3 No
0
1
No
Yes
Yes
5 GREAT ROOM 452 3661.2 No
2
1
Yes '
Yes
Yes
6 MASTER BATH 50 405 No
0
1
Yes
Yes
Yes
7 POWDER 25 202.5 No
0
1
No
Yes
Yes
8 KITCHEN 232 1879.2 Yes
0
1
Yes'
Yes
Yes
9 LAUNDRY 40 324 No
0
1
No
Yes
Yes
10 STORAGE 24 192 No
0
0
1
Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perirrieter R-Value
Area
Joist R-Value
Tile Wood
Carpet
11SIab-On-Grade Edge Insulatio MASTER BEDRO 31 ft 0
234 ft2
0 1
0
2 Slab -On -Grade Edge Insulatio DEN 24 ft 0
144 ft2
____
0 1
0
3 Slab -On -Grade Edge Insulatio SINK AREA 7 ft 0
42 ft2
0 1
0
4 Slab -On -Grade Edge Insulatio CLOSET 1 ft 0
63 ft2
_-__
0 1
0
5 Slab -On -Grade Edge Insulatio GREAT ROOM 32 ft 0
452 ft2
___
0 1
0
6 Slab -On -Grade Edge Insulatio MASTER BATH 5 ft 0
50 ft2
__-_
0 1
0
781ab-On-Grade Edge Insulatio POWDER 1 ft 0
25 ft2
____
0 1
0
4/28/2020 2:17 PM EnergyGauge® USA. 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARYCHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio KITCHEN 38 ft 0
232 ft2
----
0
1
0
9 Slab -On -Grade Edge Insulatio LAUNDRY 1 ft
0
40 ft2
----
0
1
0
10SIab-On-Grade Edge Insulatio STORAGE 21 ft 0
24 ft2
----
0
0
1
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1376 ft2.
0 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1306 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) MASTER BEDRO 30
Blown
234 ft2
0.1:
.Wood
2
Under Attic (Vented) DEN
30
Blown
144 ft2
0.1
Wood
3
Under Attic (Vented) SINK AREA
30
Blown
42 ft2
0.1.
Wood
4
Under Attic (Vented) CLOSET
30
Blown
63 ft2
0.1
Wood
5
Under Attic (Vented) GREAT ROOM
30
Blown
452 ft2
0.1
Wood
6
Under Attic (Vented) MASTER BATH
30
Blown
50 ft2
0.1
Wood
7
Under Attic (Vented) POWDER
30
Blown
25 ft2
0.1
Wood
8
Under Attic (Vented) KITCHEN
30
Blown
232 ft2
0.1
Wood
9
Under Attic (Vented) LAUNDRY
30
Blown
40 ft2
0.1
Wood
10
Under Attic (Vented) STORAGE
30
Blown
24 ft2
0.11
Wood
11
Knee Wall (Vented) GREAT ROOM
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity- Width
Height
Sheathing .Framing Solar Belo w
R-Vallie
Ft In
Et
In
Area
R-11ahe Fraction
AhSor' rrade%
1
S=>N
Exterior Concrete Block - Int InsWASTER BE
4.1 18
0 8
1
145.5 ft2
0
0
0.3
0
2
W=>E
Exterior Concrete Block - Int InsWASTER BE
4.1 13
0 8
1
105.1 ft2
0
0
0.3
0
3
N=>S
Exterior Concrete Block - Int Insul DEN
4.1 12
0 8
1
97.0 ft2
0
0
0.3
0
4
W=>E
Exterior Concrete Block - Int Insul DEN
4.1 12
0 8
1
97.0 ft2
0
0
0.3
0
5
S=>N
Exterior Concrete Block - Int Insu3INK AREA
4.1 7
0 8
1
56.6 ft2
0
0
0.3
0
6
N=>S
Exterior Concrete Block - Int InsGREAT ROO
4.1 22
0 8
1
177.8 ft2
0
0
0.3
0
7
W=>E
Exterior Concrete Block - Int InsGREAT ROO
4.1 10
0 8
1
80.8 ft2
0
0
0.3
0
8
S=>N
Exterior Concrete Block - Int InsiNASTER BA
4.1 5
0 8
1
40.4 ft2
0
0
0.3
0
9
N=>S
Exterior Concrete Block - Int InsulKITCHEN
4.1 17•
0 8
1
137.4 ft2
0
0
0.3
0
10
E=>W
Exterior Concrete Block - Int InsulKITCHEN
4.1 16
0 8
1
129.3 ft2
0
0
0.3
0
11
. S=>N
Exterior Concrete Block - Int InsulKITCHEN
4.1 5
0 8
1
40.4 ft2
0
0
0.3
0
4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUTSUMMARY'CHECKLIST REPORT
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing Solar
Belo w
_ 12 N=>S Exterior Concrete Block - Int InsulKITCHEN 4.1 35 8
13 N=>S Exterior Concrete Block - Int InsuSTORAGE 4.0999 6 8
_ 14 N=>S Exterior Concrete Block - Int InsuBTORAGE 4.0999 5 8
15 N=>S Garage Frame - Wood MASTER BE 11 30 8
1 282.9 ft2
48.0 ft2
40.0 ft2
0 240.0 ft2
0
0
0
0
0 0.3
0 0.3
0 0.3
0.23 0.3
0
0
0
0
DOORS
# Ornt
Door Type Space Storms
U-Value Width
Ft In
Height
Ft In
Area
1 E=>W
Insulated KITCHEN None
.32 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation" => chan ed to Worst Case.
Wall
V # Ornt ID Frame
Panes NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation
Int Shade
Screening
1 W=>E 2 Metal
2 W=>E 4 Metal
3 N=>S 6 Metal
4 W=>E 7 Metal
5 S=>N 8 Metal
6 E=>W 10 Metal
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.03 0.27 N
Low=E Single Yes 1.02 0.29 N
Low-E Single Yes 1.02 0.26 N
32.4 ft2 1 ft 5 in
18.4 ft2 1 ft 5 in
18.4 ft2 1 ft 5 in
40.0 ft2 12 ft 0 in
6.9 ft2 1 ft 5 in
12.8 ft2 1 ft 5 in
1 ft 5 in
1 ft 5 in
1 ft 5 in
1 ft 5 in
1 ft 5 in
1 ft 5 in
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
# Floor Area
Ceiling Area Exposed Wall"Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 280 ft2
280 ft2 35 ft
8.1 ft
11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgLA ACH
ACH 50 "
1 Wholehouse Proposed ACH(50) .000257 881.4 48.38 90.99 .0896
5
HEATING SYSTEM
# System Type
Subtype Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split Singl HSPF:8.2
27 kStu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency
Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split Sing[ SEER: 14
29 kBtu/hr
cfm 0.8
1
sys#1
4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405=2017 INPUT.SUMMARY-Ci-IFCKLIST RFPART
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
Tankless
Garage
0.6
1 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cart # Company Name
System
Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
---- Supply ---
---- Return ---
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 120 ft2
Attic
45 ft2
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Cooling Jan [ I Feb
HeatinJan [X] Feb
Mar
Mar
Apr
Appr
May
May
Jun Jul
f Jun MJul
nAug.
AuMSepp
Sep
Oct
Oct
Nov
Nov.
Dec
f X} Dec
VentingJan [ l} Feb
Mar
Apr
L
[
May
[ Jun Jul
Au
Se
Oct
Nov
[ j Dec
Thermostat Schedule: HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78- 78
78
78
78 78
78
78
Heating (WD) AM
68
68
68.
68
68 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68.
68
Heating (WEH) AM
68
68
68
68
68 68
68
68
68 68
68
68
PM
68
68
68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
DEN
Defauit(8 Ibs/sq.ft,
ft2
ft
0.3
SINK AREA
Default(81bs%sq.ft.
ft2
ft
0.3
CLOSET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT ROOM
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
POWDER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Defa4lt(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default(8 Ibs/s .ft.
0 ft2
Oft
0.3
STORAGE
4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE:402.4.1.1
AIR BARRIER AND INSULATION INSPECTION'COMPONENT CRITERIA
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE:COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: WYNNE BUILDING CORP. Jurisdiction:
w
Design Location: FL, Fort Pierce
v
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
notbe used as a sealing material.
Breaks or joints in the air barrier shall be sealed:
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs -or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The Junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame wails
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated. `
Floors.
The air barrier shall be installed at any exposed edge of
Floor framing. cavity insulation shall be installed:to
(including :
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from. the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned s ace shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow Cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Ds.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated..
Plumbing and wiring
Batt insulation shall be cut neatly to, fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tuff
The air barrier installed at exterior walls adjacent to, showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
ElectdpaVptione box or
The air barrier shall be. installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers. shall only be
sprinklers
sealedin a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinki aglyaLplalwand walls or ceilunas
a. In addition, inspection of log walls shall be in accordance with the provisions.of [CC-400.
4/28/2020 2:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
t
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location .& insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
1
13. Cooling system: Capacity
29.0
a) Split system SEER
14.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package . SEER
c) Ground/water source SEER/COP
.6. Conditioned floor area (sq. ft.)
6.
1306
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.543
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
27.0
c) Area
7c.
128.9
a) Split system heat pump HSPF .
8.2
b) Single package heat. pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coeffiicient(SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry.(Insulation R-value).
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
15. Water heating system
a) Electric resistance EF 0.60
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
10131.
11.0
10132.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11 a.
30.0
b) Cross ventilation No
11 b.
c) Whole house fan No
11c.
19.0
d) Multizone cooling credit
11d.
'. No
e) Multizone heating.credit
f) Programmable thermostat No
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving.features which.will be installed (or exceeded)]n this home before .final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: THE COTTAGE T City/FL Zip: FT: PIERCE, FL
4/28/2020 2:21:49 PM EnergyGauge® USA 6.0.04 (Rev.. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1