Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information
remma ry Job; wrights°i® Po BYEndreHouse QUICK CALLS, INC. For. WYNNE BUILDING CORP. jvv-, qCA,-- THE COTTAGE, FT. PIERCE, FL Notes: Design Information Weather: Winter Design Conditions Outside db Inside db Design TD 42 OF 70 .OF 28 OF Heating Summary Structure 16327 Btuh Ducts 4013 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 20340 Btuh Infiltration Method Construction quality Fireplaces Fort Pierce, FL, US Simplified Average 0 Heatingg Cool' "in Area (fF) 1306 .1306 Volume (ft3) 10519 10579 Air changes/hour 0.45 0.23 Equiv AVF (dm) 79 41 Heating Equipment Summary Make Carrier Trade CARRIER -Model CH14NBO3000GOA0 AHRI ref 9162387 Efficiency Heating Input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF 8.2 HSPF 28000:.Btuh @ 470F 26 OF 967 cfm 0048 . cfm/Btuh 6.50 in H2O Backup: Input = 5 kW, Output =18005 Btuh, 100AFUE Summer Design Conditions Outside db 90 OF Inside db 75 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Sensible Cooling Equipment Load Sizing Structure 15522 Btuh Ducts 5251 Btuh Central.vent.(0 drn) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swin .multiplier_ Equipment load 0.95 19734 Btuh sensible Latent Cooling Equipment Load Sizing Structure 2094 Btuh Ducts 1524. Btuh Central vent (O cim) 0 Btuh (none). Equipment latent load 3618 Btuh Equipment Total Load (Sen+Lat) Req. total 0.70 SHR 23352 2.3 Btuh ton capadty at Cooling Equipment Summary Make Carrier Trade CARRIER Cond CH14NB03000G0A0 .Coil FX4DNBO43L AHRI ref 9162387 Efficiency 11.5 EER,14 SEER Sensible cooling 20300 Btuh Latent cooling 8700 Btuh Total. cooling 29000 Btuh Actual. airflow 967 cfrn Airflowfactor 0.047 cftdBtuh Static pressure 0.50 in H2O Load sensible heat ratio 0.85 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wriglltsoftm 2020,Jarr0816:27:10 Right-Sdte®,Uriversal 201.919.0.07 RSU08101 ACM Page 1 \WrightsoftWAC\WYNNEBUIDLING-THECOTTAGE.np CaIc=MJ8 Frort Door faces: SW - - wrightsoft° Righ"o Worksheet Job: Enti1'12 House Date: By. QUICK CALCS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phore:772466-6799 Email: QUICKCALCS ,AOL.COM 1 Room name Entire House MASTER BEDROOM 2. Exposed wall 145.0 It 31 D ft 3 Room height 8.1 ft 8.1 ft heal/cool 4 5 Room dimensions Room area 1306.0 T 13.0 x 18.0 ft 234.0 flz Ty Construction U-value Or HTM Area (T) Load Area (f 2) Load number (Btuh&2_- F) (Btu hlfN) or perimeter (ft) (Btuh) or perimeter (ft) (Biuh) Heat Coal Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 VE'-13AAoccs.. G - 2glaahg,droutr, 13A-4ots - 0.143 1,040 0.143 " n .h a 4.00 29.12 4.00 : 2:19 . 21.68 2.19 .. 446 18 162 427 0 129 1710.• 537 516 934 400 282 0 07 0 0 0. 0 0 0'.0 0 0. 0 11 2 glazing, droutr, 11D0 1.040 0.390 a a 29.12 1022 39.42 10.34 13 20 2 20 368 223 498 211 0 0 0 0 0 0 0 0 D G 13AAocs 2'glazirig,droutr; 13A4ocs 0;143 1.040 0.143 .. s s: w 4.00 - 29.12 4.00 " 2.19 : - 21.68 2.19 284 7 284 277 .. 7 192 1107 202 767 605 150 419 .146 0' 105 146 0 t 584 0 291 319 .. 0 159 1Ao1om 1A h1om 1Prh1om 16C-30ml 1270 1270 1270 0.032 w w w 35.56 35.56 35.56 0:90 34.77 61.76 63.40 128 41 18 33. 1306 41 3 5 - 1306 1451 656 1162 1170 1419 1139 2072 *1672 0 0 33 234 0 0 5 ` 234 0 0 .1162 210. 0 0 2072 300 G C F 22A-tpl 0.989 27.69 0.00 1306 145 4015 0 234 31 858 0 6 c) AED excursion 3591 997 Envelope lose/gain 13885 13393 3105 3847 12 a) Infiltration 2441 668 522 143 b) Room ventilation 0 0 0 0 13 Internal gains: Oooupants@ 230 2 460 0 0 Appliances/other 1000 0 Subtotal (lines 6 to 13) 16327 15522 3627 3990 Less external load 0 0 0 0 Less transrer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 16327 15522 3627 3990 15 Dud loads 1 259/6 34% 4013 5251 259/6 34% 892 .1352 Total room load 20340 20773 4518 5342 Air required (dm) 967 967 215 249 Calculations aDDroved bvACCA to meet all reauirements of Manual J 8th Ed. wrigtls>tsoft" 2020-Jarr081627:10 Right -Suite@ Universal 201919.0.07 RSU08101 Page 1 1WrightsoftWAC1WYNNEBUIDLING-THEGO7rAGE.W CaIc=MJ8 Frort Door faces: SW - wdglaftW Right-J® wt rksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LANE; FORT PIERCE, FL34946 Phone: 772-466-6799 Email: QUICKCALCS ,AOL.COM 1 Room name DEN SINKAREA 2 .ExposedvdI 24.0 it 7.0 It 3 Room height 8.1 It heaVcool 8.1 ft heaV000l 4 5 Room dimensions Room area 12.0 x 12D ft 144.0 T 6D x 7.0 it 42.0 IF Ty Construdion U-value Or HTM Area (ft') Load Area (IF) Load number (Btuh/ft{°F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 MA = -" 2glaang,drou7, . ' 0.143 1t040 0.143. , m ' :' n`.. a -..4.00 ' 29.12 4.00 219 21'.IM 2.19 97 ': p 0 - 97 0 0 '389 0 0 - 213 .0 0 0 ` 0 0 0 ` ' 0 0 .. 0 0 0 0 0 0 yJ. 11 2glazing, drou7, 11DO 1.040 0.390 a a 29.12 10.92 39.42 10.34 0. 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 _13A�o�s LamG D -.G V�! 2glaang drout, 13A4ocs OJ43 :..1.040 0.143 s s:; w 4.00 29.12 4.00 • 2s19 21.6g 2.19 0 . 0- 97 0 -0 79 . 0 ... 0 315 .0. :' .. 0 172 .- . 57 0 0 57 :0 0 227' ,. ": 0' 0 124 ' . 0 0 IA-c1om 1Ahlom 1270 1270 w w 35.56 35.56 34.77 61.76 0 18 0 3- 0 656 0 1139 0 0 0 0 0 0 0 0 I-C L�-rG C : 1A h1.om `16C30m1 1270 0.032 w : - 35.56 0.90 63.40 128 0 144 0 144 0 . 129 0_ 184 0 42 0 42 0 38 0. . 54 F 22A tpl 0.989 - 27.69 0.00 144 24 665 0 42 7 194 0 6 c) AED exoursion . 574 -3 Envelope loss/gain 2154 2283 459 175 12 a) Infiltration 404 111 118 32 b) Room ventilation' 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoes(other 0 0 Subtotal (lines 6 to 13) 2558 2394 .576. 207 Less extemal load 0 0 .0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2558 2394 576 207 15 Dud loads 25% 34% 629 811 25% 34% 142 70 Total room load 1 1 3187 3205 718 278 Air required (dm) 152 149 341,13 Calculations approved byACCAto meet all requirements of. Manual J 8th Ed. -F}h ,tirliglstsotla 2020-Jair08.16:27:10 Aft 12igtt-Su'te@)Uriversal 20l9 l9.0.07 RSU08101 Page 2 \WrigHsotWAC1WYNNEBUIDLING-lHECOTTAGE.np Calc=MJ8 Front Door faces: SW ht� Ri ; ht-M Worksheet Job: • '� fillJfi9 g . Date: Entire House • QUICK CALLS, INC. ay 317 ST. LUCIE LANE, FORT.PIERCE, FL34946 Phone:772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name CLOSET GREAT ROOM 2 Exposed wall 0 ft 32.0 ft 3 Room height 8.1 ft headcool 8.1 ft heat/000l 4- 5 Room dimensions Room area 1 9.0 x 7A ft 63.0 fF 1.0 x 452.0 ft. 452.0 ftz Ty Construction U-value Or HTM Area (iF) Load Area (T) Load number (BtuhflF-°F) (B1uhflF) or perimeter M (Biuh) or perimeter (ft) (Btuh) Heat Cool Gross NIP/S Heat Cool Gross N/P/S Heat Cool 6 ; 13A-flocs 2 glanng, dr.outr, . " flocs 0143 11040 0.143 ".n n' a 4.00, 29.12 4.00 2:19 21?68 2.19 0 0 0 0 0 0 0 0 0 0 - 0 0 . 178' ` 18 0 160 0 0 :,640 537 0 350, 400 0 T:13A 11 2glaang,droutr, 11DO 1.13A4ods: - _ i2glaang;droutr • .- 1.040 0.390 0143 1.040 a a s; . si 29.12 10.92 4 dd 29:12 39.42 10.34 2:19 1168 0 0 , 0 0 0 0 ` 0 0 0 0 . 0 .. 0, 0 0 0 0 0 0 . 0 0: 0 0 6 :0:. 0 0 6 0--' 0 0 0 D G �:!) G 13A-4ocs 0.143 w 4.00 2.19 0 0 0 0 81 40 161 88 1A-c1om 1A-hlom 1270 1270 w w 35.56 35.56 34.77 61.76 0 0 0 0 0 0 0 0 41 0 41 0 1451 0 1419 0 G 1A-h1om 16C30m1 22A tpl 1270 0.032"`=-:. 0.989 w. - 35.56 6.90 27.69 63.40 128 0.00 0 63 63 0 '63 0 0 56 0 0 81: 0 0 452: 452 0 452'" 32 0 406, 886 0, 579 0 C F 6 c)AEDexcursion -1 2069 Envelopeloss/gain, 56 80 4080 4903 12 a) Infiltration 0 0 539 148 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 2 460 Applianoeslother 0 0 Subtotal (lines 6 to 13) 56 80 4619 5511 Less eAemal load 0 0 0 0 14 Less transfer Redistribution Subtotal 0 0 56 0 0 80 0 0 4619 0 0 5511 1151 Ductloads 25% 34% 14 27 259/6 340% 11W 1868 Total room load Air required(clm) 70 3 107 5 5754 274 7379. 343 Calculafions approved byACCA to meet all requirements of. Manual J 8th Ed. wrilgi�r�soZ9t" 2020466-08.1627:10 RightStite@)Uriversal20l9i9.0.07kSUO8lO1 A...\WriglisoftHVAC\WYNNEBUIDLING-THECOTTAGE.nQ Calc=NU8 Front Door faces.,SW Page --1 - wr gtitsow Right4@'Worksheet 'Job. House Date: QUICK CALLS, INC. By 317 ST. LUCIE LANE, FORTPIERCE, FL34946 Phone:772-466-6799 Email: QUICKCALCS !AOL.COM 1 Room name MASTER BATH POWDER 2 Bposedvtiali 5.0 ft. 0 ft 3 Room height 8.1 ft heaNcool 8.1 ft heat/cool 4 5 Room dimensions Room area 10.0 x 5D ft 50D ft2 5D x 5.0 ft 26.0 fF Ty Construction U-value Or HTM Area (fF) Load Area (ft2) Load number (Bhuh/ft _-F) (Btuh/F) or perimeter (ft) (Btuh) or perimeter (ft) - (Binh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yl 1-G 13A4ods,. ;'2glaang;drouU; 13A-4acs 0143 1040 0.143 n ,:`n a 4:00: 29:72 4.00 2:19 21:68 2.19 0 :. 0 0 Q 0 0 0 0 0 0 0 0 0 0 0 0' 0 0 0 0 0 -0. 0 0 11 2glaang,droutr, 11DO 13A-00cs: 2glaang;droutr 13A4= 1.040 0.390 -0143 1040 0.143 a a s :. a:- w 29.12 10.92 4.00 29AZ 4.00 39.42 10.34 2.19 21.68 2.19 0 0 41 7 0 0 0 34 7 0 0 0 . "" 134 -202 0 0 0. - . 73 : 150 0 0 0 ,, :. 0 ." 0 0 0 0 ' ; 0 0 0 0 0 A 0 0 0 0 0 " 0 0 D 1A-c1om 1Ahlom 1270 1270 w w 35.56 35.66 34.77 61.76 0 0 0 0 0 0 0 0 0 0 0 0 6 0 0 0 I-G I�_GG C `" '-. 1Ahlom t16C36ml- 1270 0.032 w " , 35.56 090 63.40 128 0 50 0 50 0 45 0 64 0 ' " 25 0 "' 25 P. 22 0. : ". " 32 F 22A-tpI 0.989 27.69 0.00 50 5 138 0 25 0 0 0 6 c) AFED excursion 4 0 Envelope loss/gain 520 284 22 32 12 a) infiltration 84 23 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 604 307 22. 32 Les9exfemalload 0 0 0 6 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 604 307 22 32 151 Dud loads 1 251/6 349/6 148 104 251/6 34% 6 11 Total room load 752 411 28 42 Airrouired(dm) 36 19 1 " 2 Calculations approved byACCAto meet all requirements of Manual J 8th'Ed. - p Ilgla aft" 2020-Jao-081627:10 .4Cl�A _ Right-SuteO Uriversa1201919.0.07 RSU08101 Page 4 \WrightsoftWAC1WYNNEBUIDLING-THECOTTAGE.np Calc=NU8 Frort Door faces: SW htsoft° WO Ri hWorksheet Job: =" 9 Entire House Date` QUICK CALCS, INC. BY 317 ST.. LUCIE LANE; FORT PIERCE, FL34946 Phone:772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name KITCHEN LAUNDRY 2 Exposed wall 38.0 It 0 ft 3 Room height 8.1 ft heaV000l 8.1 ft heaftol 4 5 Room dimensions Room area - 1.0 x 232.0 it 232.0 tP 4.0 x 10.0 ft 40D T Ty Construction U-value Or HTM Area (flz) Load Area (ft=) Load number (BWhhll--°F) (BWhhP) or perimeter (ft) (Btuh) or perimeter (ft) (BWh) Heat Cool Gross N/P/S Heat Cool Gross N1P/S Heat Cool 6 ".-I-G 13A4ocs, ': 2'gla tig;droutr,. " " 0.143 . 1.040 `• n . - n .. 4.00 29.12 2.19 ' =21.68 : 138 :" 0, 138 0 551 0 . 301 0. 0 0 ." . 0 .0 0 0 0. . ...0 1L-G 13A-0as 0.143 a 4.00 2.19 130 97 387 211 0 0 0. 0 1111DO 2 gl&ng, dr outr, 1.040 0,390 a a 29.12 10.92 39.42 10.34 13 20 2 20 368 223 498 211 0 0 0 0 0 0 0 0 r 13AAocs` . 2glaang droutr; 0143 -1.040 " s . 4-20.12 4.00 " -2.19 , ..21.68.. 41 0 41 =- 0 162 - 0 89 : -0 •0 0 0 _. ,0 -0 0 - ..0 -0 13A4ocs 0.143 w 4.00 2:19 0' 0 0 0 0 0 0 0 1Ac1om 1A-h1om 1270 1270 w w 35.56 35.56 34.77 61.76 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 C 1A-h1om r16C30m1 - 1270 0.032 w 35.56 0.90 63AO 128 0 : " 232 0 232 0 208 0 297 0 40 0 . 40 0 _ 36 0 51 F 22A-tpl 0.989 27.69 0.00 232 38 1052 0 40 0 0 0 6 c) AED excursion -37 -1 Envelope loss/gain 2951 1570 36 51 12 a). Infiltration 640 175 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoe-gother 1000 0 Subtotal (lines 6 to 13) 3591 2745 .36 51 Lesseksmalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 3591 2745 36 51 15 Dud loads 250/o 34% 883 931 25% 340/o 9 17 Total roomload 4474 3676 4$ 68 Air required (dm) 213 171 2 3 Calculations ap0mved bvACCA to meet all requirements of Manual J 8th Ed. ' ' wriglftsott� Rigtd-SuteC� Uriversa1201919.0.07 RSU08101 2020-Jan-081627:10Page s \WdghlsoftHVAC\WYNNEBUIDLING-THECOTTAGE.np Calc=MJ8 FrortWor%oes:SW wr+ghtso Right-J® Worksheet Job. Entire House Date: • QUICK CALLS, INC. By 317 ST. LUCIE LANE, FORT. PIERCE, FL34946 Phone: 772-466-6799 Email: QUICKCALCS@AOL.COM 1 Room name STORAGE 2 Bposed wall 8.0 ft 3 Room height 8.1 Itheat/cool 4 5 Room dimensions Room area 4.0 x 6.0 It 24.0 82 Ty Construction number U-value (BbjWF) Or HTM Area (tt=) or perimeter (tt) Load (Btuh) Area or perimeter Load Heat Cool Gross N/P/S Heat - Cool Gross NIPS Heat Cool 6 . . T— 13AAors : _ -2glaang,droutr,. 13AAocs 0.143 1.040 0.143 . n n a 4.00 25AZ 4.00 2:19 ZC68 2.19 32 0 32 32 0 32 130. 0 130 71 0 71 . T:—D 11 2glazing;droutr, 11DO 1.040 0.390 a a 29.12 10.92 39.42 10.34 0 0 0 0 0 0 0 0 —G v� L 13AAoss -, 2glanng;droutr; 13A4ocs 0;143 .1.040 ," s s; w 4;00 29.1'2 4.00 2r19 . . 21.68 2.19 ' . 0 0 0 0 0 0 • 0. 0 0 0 : 0 0 . ' —G IA-clom 1Ah1om 1270 1270 w w 35.56 35.56 34.77 61.76 0 0 0 0 0 0 0 0 T0.143 1A h1om 16C.30m1 ?Xtpl 1270 0.032 0289 w '`•- . 35.56 0.90 27.69 63A0 128" 0.00 0 24 24 0 24 8 0 22 222 0 31 0 C. `. F 6 c) AED excursion 3 Envelope loss/gain 502 170 12 a) Infiltration 135 37 b) Room ventilation 0 0 13 Internal gains: Occupants@ 230 0 0 Appliances(other 0 Subtotal (lines 6 to 13) 637 207 Less external load 0 0 Lesstransrer Redistribution 0 0 0 0 14 Subtotal 637 207 ' 15 Dud loads 259/6 29% 157 60 Total room load 794 266 Air required (crm) 38 12 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. w�iglatsol�Ca 2020-Jan•08.1627:10 AWK Rigtt.Sate® Universal 201919.0.07 RSU08101 Page 6 1WrighlsoftWAC1WYNNEBUIDLING-THECOTTAGE.np CaIc=MJ8 FrortDoorfaces:'SW +WIghtsofty-S r®Duct Stem Summary o: Entire House By: QUICK CALLS, INC. 317 ST. LUCIE LANE, FORT PIERCE, FL34946 Phor e:7.72.466-6799 . Email: QUICKCALCS@AOL.COM For: WYNNE BUILDING CORP. THE COTTAGE, FT. PIERCE, FL External static pressure Pressure losses Availablestatic pressure Supply/ return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.50 in.H2O 0.28 in H2O 0:22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 cfm 126 it Supply Branch Detail Table Cooling 0.50 in H2O 0.28 in H2O 0.22 in H2O 0.110/0.110 in H2O 0.080 in/100ft 967 cfm Name Design (Btuh) Htg (clm) Clg MITI) Design FR Dian (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk CLOSET c 107 3 5 0.080 4.0 OxO VIFx 24.6 90.0 st1 DEN h 3187 152 149 0.080 7.0 OxO VIFx 33.5 90.0 st1 GREATROOM c 3689 137 172 0.080 8.0 Ox0 VIFx 14.6 70.0 GREAT ROOM -A c 3689 137 172 0.080 8.0 Ox 0 MFx 16.1 70.0 KITCHEN h 4474 213 171 0.080 7.0 Ox 0 VIFx 4.5 70.0 LAUNDRY C 68 2 3 0.080 4.0 Ox 0 VIFx 5A 70.0 MASTER BATH , h 752 36 19 0.080 4.0 OxO VI Fx 32.9 90.0 st1 MASTERBEDROOM c 2671 107 124 0.080 7.0 Ox0 VIFx 27.9 90.0 st1 MASTER BEDROOM -A c 2671 107 124 0.080 7:0 Ox0 VIFx 35.9' 90.0 st1 POWDER c 42 1 2 0.080 4.0 Ox 0 VIFx 29.2 90.0 st1 SINKAREA h 718 34 13 0.080 4.0 OxO VIFx 30.9 90.0 st1 STORAGE h 794 38 12 0.080 4.0 Ox0 VIFx 11.2 1 70.0 Supply Trunk Detail Table Name Trunk Type Htg (cf n) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 PeakAVF 441 437 0.080 561 12.0 0 x 0 VinIFIX -Fl&- Ai Wrjgh jSOfjl 2020;1an 081627:11 .m v��nw« ��,� Right-SuteS Uriversal 201919.0.07 RSU08101 Page 1 ...1WdghlsoftWAMWYNNEBUIDLING-THECOTTAGE.np Calc=MJ8 Fror3Door faces: SW Return Branch Detail Table Name Grille Size (in) Htg (dim) clg (drn) TEL (ft) Design FR veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) . Duct Mat Trunk rb1 Ox0 967 967 0. 0 0 0 Ox 0 MR ->�- wrightsofV 2020-Jarr081627:11 r arnn de•rtrm:x•�yumwy RightSute@) Uriversal 201919.0.07 RSU08101 Page 2 ...1WrighlsoftWAQWYNNEBUIDLING-THECOTFAGE.rLp Calc=W8 FrordDoorfaces:SW