HomeMy WebLinkAboutTruss,&—LIFE SAFEI
This symbol identifies Life Safe
_ given special attention by all,pii
e
VARNING
�nings that should be read
installing trusses.
5PAGIN
IG
NOTE
ALL TRUSSES
Al
TO BE SET
AT 2"-0:
IN
ENTER
EXCEPT AS
OTED
MULTIPLE PLY TRL SSES MUST BE
ASTENED TOGETHER PER ENGINEERIN(
BEFORE SETTIN . REFER TO
ENGINEERING DRA V11I�4G TO DETERMINE
IF MULTiIPl E PLY.
II I'
II
DON'T LIFT, T
WITH SPANS LOf
30' BY THE
CONSULT
30' Spanl,or less A
60 degrees
or less
2
Tag 'Line span , PP
REFER TO BCSI
Truss must be set this wcy 'r crone usetl Tru.
u 's a r yo t ay et etch T
Insist crane operator sets truss this way.
All load bearing'("
beams & lintels ml
at indicated height
Q are inst-C
I
AIR HAN Ill IL
UNLESS NOTED ELSEWHEREuOh
ARE NOT DESIGNED FOR A14 H,
e ANY OTHER A/C REQUIREMEN
WITH BUILDING CODE AND P
CONSULT WITH BUILDING DEPAI
For Truss_to Truss,
Connections see
hanger/connector;
schedule in engineering
package. I
t
SEAT PLATES E
I
M1P CgggIER I0CA1ED AS DIMENSIONED ON tpVWT
I
u
=w a
I
sa 77
00 rNRu
GORY RJ�S�
CORNER DETAIL (�
OVERHANGS NOT SHOWN FOR GIARITY c
I!
I� I
II
i
i
12 I'
4.00CID
p
rl
12 12.00
M
�I
upset=1/4" heel=315/16'
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
END DETAIL: TYPICAL A L
I
I
I
I
THAN
30' to 60' Span
Spreader Bar
Approx 2/3 to ---4,,
1/2 of Span
T BCSI
REFER 0
cost be set this way If crone used.
is an example, truss may not match.
st crone operator sets truss this way..
Ils, headers,
I•t be in place
efore trusses
'd• A
� R N O T Ill
HIS LAYOUT, THESE TRUSSES
IDLERS IN THE ROOF OR FOR
i. THIS MAY BE IN CONFLICT
DESIGN REQUIREMENTS.
MENT AND A/C CONTRACTOR.
Carrying Girder
ails must be as
Shown Guide tabs o
Dome angle nails.
Carried Truss
The Architect's or Architect's representative's
shop drawing approval is NOTa
"double check" of the contractor.
tractor shall rernain responsible
The can
ra
TRUSSES FOR THE FIRST MODEL SHOULD BE SHIPPED AND SUCCESSFULLY SET BEFORE ANY MORE TRUSSES ARE BUILT FOR TdAT MODEL. far checkingield rneeria. entsand
other construction on creterra. Architect's
p — — 1 approval roll ers general roof shape,
ARRANGE WITH CRANEOPERATOR IN ADVANCE FOR A SPREADER BAR OF 18' - 24° IN LENGTH structure a review their
eras Strapping,
loading on
structure from gr ity and uplift loads and
I I their re a five tocatio Is..,
V L s r I - .. _ eP_Prova JIl -
Date: _
� DO not vtand On trusses until they are braced per BCSI & properly Walled t0 straps &hangers ErradQeiEBradenA.1.A.P: �.,
IL 15' 3" - - 19' 9" 19' 9" +-- 15 -3"
_ _ _ _� FABRICATION AGREEMENT
I ; TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT is SIGNED & RETURNED
The legal description of the properly where the trusses will be Installed is:
I ..
.The undan;lgned ecknowledgea end agrees:
J1 J7 1: TNssea will ba made In stdd eccordenee with this truss placement. diagram layout,
J1 J 2: Nhd�mensllons b this layout haute Ibsen varifisad by the uUl oderal9 edNss6s. .
.3. Unless wdtten notice rm
Is prevlded by cergfiad mall to Chambers Truss within ten (10)
J3 J3 days of delivery the undersigned agrees that no backchen;es will be allowed. In the event
- �. I such writer nogce Is (umlehed Chambers Trues shall have three (3) bu nose days In which
J3 r` r` �e
J : 'lo begin repairs required, or to substitute other trusses, at Chambers opt It.
70 4. The undersigned acknowledges recelep� o(BBCS e' A3" �o make the job site (suitable for
6. Dellvary Is to Job site. It ie the buy, on to dete a the sultabllity of the job site or a
u the sole her
h b
tubers T N68
ha only.
. C or um delivery
INo f d de responsible ry J5 - J5 rY res anal PI
e
O O portion of the Job site for delivery. Ch6mbers Truss will b p
JS J The buyer is responsible for additional delivery expenses If Chambers Truss has to redeliver
1 because Job site is riot prepared for delivery or buyer is not prepared far delivery of trusses
�✓ Q- �� �%� Buyer is responsible to Chambers Truss for towing costs due toe teaconditi ngea are, made In
o change Y subject 7 below s su 9
era re h 1
Hce as shown p 9
8. P Chambers Truss,
cha ed b C ham b ru
GRA
GRA this IayouL A S50 per hour fee for revlslons may be rg y
Is a PURCHASE ORDER to 111 be made on delivery and paid within terms of no
bo dw. Involca wl
a Bona I
e re P
e arc
ern not re If buyer can a Iva P I g of dell Y
tech
edu led data ry
.. be made a
A .on delivery. Involoe may.
A delivery of tabdcate'I Wssea, The undersigned ag yes to pay e. 14 %. per s reasonable
_ _ _ allomey's tee for colledl'ons In event of payment not timely made. 1.12 %, par month servJce I
charge will S added for all sums not Psi d within terns.
B. SI nature or Initlala anywhere on this sheet constitutes agreement to all tarma herein. - -.
Al 1 Al unwndlUonell guarantees payment when due of any end all Indebtedness owed to
1consideration of Chambers Truss extending uedit for this matedel the undemigned
y on recelving mate end the undersigned agrees to pay such {
b en
ss dY the
Tru Y. Y made b
tube material b Y e met
1 1\ 1 1 0
Indebtedness Induding attorneys tees, If default In payment f
A2 1 I redplentt
c10. In the avant o1 any Iltigation concerning this agreement, the items furnished hereunder
or payments referred to hareln, the, parties agree that the sole venue for any such ectlon will
be Saint l:ude Count'. Flodde.
' 11. Design responslblllges are per -National Standard And Rebommanded Guldallnes On
A3 ANSI/TPt ITCA 4 r 2006 on Using Metal Plate Connected Wood Trusses
`....:
D
�.
ATE ,
A4 . A4 SIGNED o
_ TITLE—_-- .
ip iD FOR
.:
Aspteaderbarmaybele9yfredPer
A5 .. A5 BCSI 1-03" M ptevorttfryury & damage.
Multiple ply trusses must be fastened togithar per engineering
A5 are set, failure to do so can result in roof collapse.
A5 before they
1
1 Temporary and permanent bracing are required and can save Ilfe
and roPe1tY
end fa the responslblllty of the truss erector.
P delivery do
ed on
pack
et Inc
luded
lu d rY
A5 1 � 1 A5 Study the contents of the lnformatlon p
( 1 before setting trusses.
A5 T mtaTro� �ust b spot P idesign
to b and s9uare ury& darraga
1 1
Do not set bunks or stack of PlYwood, roofing material or any
A5 1 other concentrated loads on trusses this can cause collapse,
DO NOT SET TRUSSES USING THIS LAYOUT { o'
USE LAYOUT DELNERED WITH TRUSSES T�+O SET TRUSSES I
A5 14' 9" 19t 113"I 14' 9" `/�� f'1M� BERS TRUSS INC
A5
1 1 -
A5 - A5 ��
1 2. 21 112 /12 /1 S. 1
nue
�IA5 , I - - ----- - A5 " 310riOleander
Fort Pie , Florida 34982-6423
, w,. �., w ,, . / \ \ \ I
I' CHAMBERS
12
4.00 f
8,
upset=1/4" heel=315/16
PLUMB CUT END
2 x 4 Top Chord
WALL HEIGHT 8'
TYPICAL END DETAIL
INDICATES LOAD BEARING
REQUIRED BY TRUSSES
SUPPLIED BY BUILDER
AT A HEIGHT OF 8'-0"
ABOVE FINISHED FLOOR
T
v
'-1 '-1 J-- �%,,w-M'�
i' CLOU" SED ARIAS ARE OF %�
SPECIAL CONCERN & MUST BE t
CHECKED CAREFULLY & MAY IF
t INDICATE ' DEVIATION FROM--��
�._-PLANS.'^
Ib, A"
PORCH L.EFT
B00-551-5932
Fort pierce 772-466-2012 Fax 772.466-8711
Vero Beach 772569.2012 Stuart 772.286-3502
92.0/93.2 MITEK 4.2
DESIGN CRITERIA
County SAINT LUCIE
Building Department ST LUCIE COUNTY
Wind Design Criteria ASCE 7-2010
Wind Design Method MW Wind ASCE 7-10
RoofingMaterial l
T C Loading t� r
y Top Chord Live UCII•IT'
H c Top Chord Dead 7 2
�
E I °,,o I Bottom Chord Live 10 Non -Concurrent
o c — Bottom Chord Dead 10 3
(�I c N I TOTAL Load 37 7.2
«' Duration Factor 1.25
;v Wind Speed 165mph
N to Top Chord C.B. Sheeting by builder.
y Bottom Chord C.B. Sheeting by builder.
v \7� Highest Mean Height 15'-0" FILE COPY
Building Type ENCLOSED
Building Category II:Non Restrictive
Exposure Category C
Barrier Island No
Conforms to FBC 2017
W
F-
(n
Q
15 TRUSS DRAWINGS ARE ATTACHED TO LAYOUT
Verify DESIGN CRITERIA shown above with the
building department and your engineer. ,
Design Criteria is the responsibility of the
Chambers Truss Inc. Drawing Name: M11392
Scale: 1 /4 = 1'
82 total trusses, 15 different trusses.
MI 4: RLC ACAD: RLC Reviewed By:
Date:10/07/15 Revised:03/21/18
FOR Revised: 3/05/2020
WYNNE BUILDING CORP.
DESCRIPTION:
WINDSOR -
PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE
M11392 ��S
MiTek'
RE: M11392
THE WINDSOR
Site Information:
Customer: Wynne Dev Corp
Lot/Block:
Address: unknown
City: St. Lucie County
�-S
Project Name: THE WINDSOR
Model: THE WINDSOR
Subdivision:
State: FL
MiTek USA, Inc.
6904 Parke East Blvd.
Tampa, FL 33610-4115
General Truss Engineering Criteria 8r Design Loads (Individual Truss Design Drawings Show Special
Loading Conditions):
Design Code: FBC2017/TP12014 Design Program: MiTek 20/20 8.1
Wind Code: ASCE 7-10 Wind Speed: 165 mph
Roof Load: 37.0 psf Floor Load: N/A psf
This package includes 15 individual, dated Truss Design Drawings and 0 Additional Drawings.
With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet
conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules.
No.
Seal#
Truss Name
Date
1
T19781803
A
11/3/2020
2
T19781804
Al
11/3/2020
3
T19781805
A2
11/3/2020
4
T19781806
A3
11/3/2020
5
T19781807
A4
11/3/2020
6
T19781808
A5
11/3/2020
7
T19781809
ATA
11/3/2020
8
T19781810
B
11/3/2020
9
T19781811
BHA
11/3/2020
10
T19781812
GRA
11/3/2020
11
T19781813
J1
11/3/2020
12
T19781814
J3
11/3/2020
13
T19781815
J5
11/3/2020
14
T19781816
J7
11/3/2020
15
T19781817
KJ7
11/3/2020
This item has been electronically signed and sealed by Albani, Thomas using a Digital Signature.
Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies
The truss drawing(s) referenced above have been prepared by
MiTek USA, Inc under my direct supervision ``�1111111II���
based on the parameters provided by Chambers Truss. �����PS.; 4 . A4 !il
Truss Design Engineers Name: Albani, Thomas ��� O B i�
My license renewal date for the state of Florida is February 28, 2021. ���'-'v� G E N SF. q2� •��
Florida COA: 6634 No 39380
IMPORTANT NOTE: The seal on these truss component designs is a certification
that the engineer named is licensed in the judsdiction(s) identified and that the
designs comply with ANSIITPI 1. These designs are based upon parameters
shown (e.g., loads, supports, dimensions, shapes and design codes), which were
given to MiTek. Any project specific information included is for MiTek
customers file reference purpose only, and was not taken into account in the preparation of
these designs. MiTek has not independently verified the applicability of the design
parameters or the designs for any particular building. Before use, the building designer
should verify applicability of design parameters and properly incorporate these designs
into the overall building design per ANSI/TPI 1, Chapter 2.
3 S TAT E O F : 44/�/`
�O N A " �%
11111
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610 November 03, 2020
1 of 1 Albani, Thomas
t
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781803
M11392
A
HIP
1
1
Job Reference (optional)
t.namuerb r rubb, mu., rort nerve, rL 6.Z4U s Mar U ZUZU MI I eK Inausmes, Inc. I ue Mar 24 12:54:U7 ZUZU Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-KTRK2jb7uXlhmgejamLw33G2phzq_U FBTsBBV6zXjH_
1-0-0 610-14 9-0-0 14-11-0 20-2-13 26-0-0 28-1-2 35-0-0 6-0-
0-0 6-10-14 2-1-2 5-11-0 5 3-13 5-9-3 2-1-2 6-10-14 0-0
4.00 12
48 = 2x3 II 3x6 = 44 = 4x8 =
2x3
2x3 \\ 4 26 5 6 7 27 8 9
Scale=1:60.5
V
A
A
1 �
IA
a
�o r�
3x4 — 3x4 = 3x6 — 6x8 = 3x4 = 3x6 = 3x4 = 3x5
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in (loc) Udefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.57
Vert(LL)
0.42 12-23 >572 240
MT20 2441190
TCDL 7.0
Lumber DOL
1.25
BC 0.47
Vert(CT)
0.37 12-23 >659 180
BCLL 0.0
Rep Stress Incr
YES
WB 0.94
Horz(CT)
0.03 10 n/a n/a
BCDL 10.0
Code FBC20171TP12014
Matrix -MS
Weight: 161 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purling.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 4-5-1 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 15=0-8-0, 10=0-8-0
Max Horz 2=-97(LC 10)
Max Uplift 2=-235(LC 12), 15=-1439(LC 12), 10=-799(LC 12)
Max Grav 2=467(LC 17), 15=1596(LC 1), 10=685(LC 22)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-639/108, 34=-396/0, 4-5=-967/776, 5-7=967/776, 7-8=454/938, 8-9=-1009/1884,
9-10=-1265/2154
BOT CHORD 2-17=0/652, 15-17=0/430, 14-15=-704/454, 12-14=-1586/938, 10-12=-1971/1174
WEBS 3-17=-372/461,4-17=272/451,4-15=-1087/1002, 5-15=-336/386, 7-14=-766/399,
8-14=-580/997, 8-12=-958/447, 9-12=358/600, 7-15=-132912190
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 9-0-0, Exterior(2) 9-0-0 to
13-11-6, Interior(1) 13-11-6 to 26-0-0, Exterior(2) 26-0-0 to 30-11-6, Interior(1) 30-11-6 to 36-0-0 zone; porch right exposed;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
This item has been
3) Provide adequate drainage to prevent water ponding.
electronically signed and
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
Sealed by Albani, Thomas, PE
5) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 235 lb uplift at joint 2, 1439 lb uplift at
Printed copies of this
joint 15 and 799 lb uplift at joint 10.
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® parameters
connectors. This design is based only upon pameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPH Quality Criteria, OSB-89 and BCSI Building Component 6904 Parke East Blvd.
SafetyInformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE WINDSOR
T19781804
M11392
Al
SPECIAL
1
1
Job Reference (optional)
onambers I cuss, Inc., i-ort coerce, FL u.zqu s mar a zuzu mu t etc Inausmes, Inc. i ue mar zq iz:oq:uo zuzu
4-3-2 3-0-7 7-7-9
Scale=1:61.3
5x6 = 2x3 11 3x4 = 5x8 MT18HS =
4.00 12 4 21 5 6 22 7
13 12
3x6 = 3x5 = 5x8 MT18HS = 3x12 zz
2.00 12
10-M 14-9-0
24-6.8
35-0-0
10-0-0 4-9-0
9-9-8
10-5-8
Plate Offsets (X,Y)—
[2:0-0-2,Edge), [7:04-0,0-2-3), [9:0-1-15 Edge)
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Udefl L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.63
Vert(LL)
0.75 11-12 >563 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.91
Vert(CT) -1.21
11-12 >348 180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.77
Horz(CT)
0.35 9 n/a n/a
BCDL 10.0
Cade FBC2017rrP12014
Matrix -MS
Weight: 155 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-7-7 oc
purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 9=0-8-0
Max Horz 2=-117(LC 10)
Max Uplift 2=-825(LC 12), 9=-825(LC 12)
Max Grav 2=1349(LC 1), 9=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3209/2102, 3-4=-3006/2024, 4-5=-3022/2080, 5-6=-3022/2080, 6-7=-4643/2994,
7-8=-5324/3364,8-9=-5751/3700
BOT CHORD 2-13=-1883/3007, 12-13=-1591/2657, 11-12=-2456/3908, 9-11=-3442/5478
WEBS 3-13=425/410, 4-13=-354/571, 4-12=362/617, 5-12=-269/279, 6-12=-10341712,
6-11=-373/892, 7-11=-89711523, 8-11=-404/435
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf, BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(l) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60,
This Item has been
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
electronically signed and
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
Sealed by Alban!, Thomas, PE
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
using a Digital Signature.
will fit between the bottom chord and any other members.
7) Bearing atjoint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
Printed copies of this
capacity of bearing surface.
document are not,COnSidered
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
signed and sealed and the
joint 9.
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
8904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MITek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
Not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 quallty Criteria, DSB-89 and BCS/ Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
T79781805
M11392
Ara
SPECIAL
1
1
�THEWINDSOR
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:09 2020 Page 1
ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-HsZ4SPC008?P?zo5hBO08ULMuVYnSPxUx9glY?zXjGy
�1-0-0 8-6-0 13-0-0 14-9-0 22-0-0 27-4-7 35-0-0 a6-0-O
-0-0 8-0-0 4-6-0 1-9-0 7-3-0 5.4-7 7-7-9 -0-0
Scale = 1:61.3
5x6 = 3x4 =
5x8 =
4.00 12 4 21 5 22 6
3x4 =
3x6 =
2.00 12
3x12
10-0-0
14-1-0
22-M
241
35.0-0
10-0-0
4-9-0
7-3-0
2-0 8
10-5-8
Plate Offsets (X Y)—
[2:0-0-6,Edge] [6:0-4-0,0-2-3], [8:0-1-15 Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc)
I/defi
Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.66
Vert(LL)
0.72 10
>585
240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.95
Vert(CT)
-0.94 10-19
>447
180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.86
Horz(CT)
0.34 8
n/a
n/a
BCDL 10.0
Code FBC2017/rPI2014
Matrix -MS
Weight: 160 lb
FT = 20%
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-6-15 oc purlins.
BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 8=0-8-0
Max Harz 2=136(LC 11)
Max Uplift 2=-825(LC 12), 8=-825(LC 12)
Max Grav 2=1349(LC 1), 8=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3211/2064, 3-4=-3017/1998, 4-5=-2580/1800, 5-6=3379/2225, 6-7=-5242/3250,
7-8=-5759/3665
BOT CHORD 2-13=-1847/3008,12-13=-1403/2418,11-12=-1552/2629,10-11=-1990/3441,
8-10=-3410/5485
WEBS 3-13=420/418, 4-13=427/688, 4-12=-337/551, 5-12=-777/605, 5-11=4651925,
6-11 =-391/277, 6-1 0=-1 318/2268, 7-1 0=-503/530
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
This item has been
3) Provide adequate drainage to prevent water ponding.
electronically Signed and
4) All plates are MT20 plates unless otherwise indicated.
Sealed by Albani, Thomas, PE
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
'
using a Digital Signature.
6) This truss has been designed for a live load of 20.Opsf on the bottom chord In all areas where a rectangle 3-6-0 tall by 2-0-0 wide
Printed Copies Of this
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 8 considers parallel to grain value using ANSl1TPI 1 angle to grain formula. Building designer should verify
document are not considered
capacity of bearing surface.
signed and sealed and the
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
signature must be verified
joint 8.
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Data:
March 24,2020
AWARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
---
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
Ra
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
MiTek
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE WINDSOR
T19781806
M11392
A3
SPECIAL
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:10 2020 Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-127SgIdOBS7Gd7NIFvvehhuYXvu2Bsnd9pPr4RzXjGx
1-0-0 8.6.0 15-0-0 20-0-0 24 6-8 27-% 35-0-0 6-0
- 8.6-0 6-6-0 5-0-0 4-6-8 2-9-15 7-7-9 0-0
Scale = 1:62.3
3x5 =
4.00 12
14
2x3 11
5x6 =
13
5x6 =
4x5 =
2.00 12
3x12 Zz
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) Vdefl Ud
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.60
Vert(LL)
0.73 11 >572 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.95
Vert(CT) -0.97 11-20 >432 180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.83
Horz(CT)
0.36 9 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 160 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-6-15 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 7-12
REACTIONS. (size) 2=0-8-0, 9=0-8-0
Max Horz 2=-155(LC 10)
Max Uplift 2=-825(LC 12), 9=-825(LC 12)
Max Grav 2=1349(LC 1), 9=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-4=-3256/2031, 4-5=-2426/1588, 5-6=2680/1790, 6-7=-2829/1832, 7-8=5320/3257,
8-9=-5720/3554
BOT CHORD 2-14=-1817/3048, 13-14=-1817/3048, 12-13=-1258/2274, 11-12=2935/5103,
9-11=-3302/5445
WEBS 4-14=0/329,4-13=-897/636, 5-12=-316/661,6-12=-317/616, 7-12=-2727/1643,
7-11 =-1 072/1939, 8-11 =-390/391
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Extedor(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 9 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 9.
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP11 Quality Criteria, DSB-89 and BCS1 Building Component
safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
8904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
m�
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
�THEWINDSOR
T19781807
M11392
A4
SPECIAL
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:11 2020 Page 1
I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-DEhgt5eexIF7FHyUpcQtEvQjTIDGwGhnOT90duzxiGw
i1-0-0 8-6-0 14-9-0 17-0-0 18 0 q 24 6 8 , 27-4-7 , 35-0-0 46-0 q
i-0-0' 8-6-0 6.3-0 2-3-0 1-0-0 6-6-8 2-9-15 7-7-9 0-0
Scale = 1:62.3
4.00 12 5x6 = 46 =
2x3 II 6 7
16 15 6x10
3x5 = 2x3 II 5x8 = 3x12
2.00 12
Plate Offsets (X,Y)—
[2:0-1-6,Edge], [9:0-3-0,Edge], [11:0-1-15,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefl L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.59
Vert(LL) 0.80
13 >528 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.95
Vert(CT) -1.05
13 >400 180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.98
Horz(CT) 0.39
11 n/a n/a
BCDL 10.0
Code FBC20171rP12014
Matrix -MS
Weight: 172 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 2-6-14 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
WEBS 2x4 SP No.3
WEBS
1 Row at midpt 8-14
REACTIONS. (size) 2=0-8-0, 11=0-8-0
Max Horz 2=-175(LC 10)
Max Uplift 2=-825(LC 12), 11=-825(LC 12)
Max Grav 2=1349(LC 1), 11=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3253/1989, 3-5=-2435/1560, 5-6=-2399/1639, 6-7=2217/1501, 7-8=2380/1519,
8-10=-5361/3228, 10-11=-5716/3480
BOT CHORD 2-16=-1776/3045, 15-16=-1776/3045, 14-15=-1117/2168, 13-14=-2920/5154,
11-13=-3232/5441
WEBS 3-16=0/334, 3-15=-882/614,5-15=-238/254, 7-14=-163/427,6-14=-309/604,
6-15=-315/409,8-14=-3146/1901,8-13=-1034/1946,10-13=-343/333
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 36-0-0 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are MT20 plates unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Bearing at joint(s) 11 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
capacity of bearing surface.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 11.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33810
Date:
March 24,2020
® WARNING - Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/1912020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall �
building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek*
I
always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11Tp/f Quality Criteria, OSB-89 and SCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T19781808
M11392
A5
SPECIAL
16
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:13 2020 Page 1
ID:_kriGCA6bx7j2Syl HDXFw7ye3KX-9dpbinfuTNVrUb6twl SLJKWOV6vFOEp3meVhmzXjGu
it-0-0i 8.6-0 14-9-0 17-6-0 i 24-6-8 1 27-4-7 35-0-0 46-01
ti-0-0 8.6-0 6-3-0 2-9-0 7-0-8 2-9-15 7-7-9 -0-0
Scale = 1:60.3
�1
0
5x8 MT18HS 11
4.00 12
14 13
3x5 = 2x3 II 5x10 =
2.00 12
3x12
lm1 � r
0
8-6-0 14-9-0
24-6-8
35-0-0
8.6-0 6-3-0
9-9-8
10-5-8
Plate Offsets (X Y)--
[2:0-1-6,Edgel, [8:0-3-O,Edgel, [10:0-1-15 Edge1
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL.
in (loc) I/defl L/d
PLATES
GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.81
Vert(LL)
0.80 12-13 >526 240
MT20
244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.92
Vert(CT) -1.28
12-13 >329 180
MT18HS
244/190
BCLL 0.0
Rep Stress Incr YES
WB 0.74
Horz(CT)
0.36 10 n/a n1a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MS
Weight: 160 lb
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 31 'Except*
TOP CHORD
Structural wood sheathing directly applied or 2-2-0 oc purlins.
1-4,8-11: 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 2-2-0 oc bracing.
BOT CHORD 2x4 SP M 30
WEBS
1 Row at midpt 6-12
WEBS 2x4 SP No.3 *Except*
6-12: 2x4 SP M 30
OTHERS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0
Max Horz 2=-179(LC 10)
Max Uplift 2=-825(LC 12), 10=-825(LC 12)
Max Grav 2=1349(LC 1), 10=1349(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3247/2112, 3-5=-2449/1679, 5-6=-2397/1763, 6-7=-5452/3624, 7-9=5398/3482,
9-10=-5732/3689
BOT CHORD 2-14=-1865/3040,13-14=-1865/3040,12-13=-1223/2137,10-12=-3431/5459
WEBS 3-14=01303, 3-13=-861/619, 5-13=-2161264, 6-13=-300/527, 6-12=-2247/3526,
7-12=-323/388, 9-12=-321/306
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
This item has been
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
electronically signed and
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
sealed by Albani, Thomas, PE
DOL=1.60
using a Digital Signature.
3) All plates are MT20 plates unless otherwise indicated.
Printed this
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
copies of
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
document are not considered
will fit between the bottom chord and any other members, with BCDL=10.Opsf.
signed and sealed and the
6) Bearing atjoint(s) 10 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify
signature must be verified
capacity of bearing surface.
on any electronic copies.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 825 lb uplift at joint 2 and 825 lb uplift at
joint 10.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
,® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE.
'
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
Nil
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building
design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
MiTek'
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE WINDSOR
T19781809
M11392
ATA
COMMON
5
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:14 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-dpMzW79WEgdi61g3UkzarX2EkWJA7jTD4RN3DCzXjGt
1-0-0 8-4-0 12-11-0 17 6-0 22-1-0 26-8-0 35 0-0 6-0-
-0-0 8-4-0 4-7-0 4-7-0 4-7-0 4-7-0 8-4-0 -0-0
c5
3x6 =
4.00 12
4x5 =
17 — 15 "v ", 14 — 12
2x3 11 4x6 =
3x8 =
LOADING (psf)
SPACING-
2-0-0
TCLL
20.0
Plate Grip DOL
1.25
TCDL
7.0
Lumber DOL
1.25
BCLL
0.0
Rep Stress Incr
YES
BCDL
10.0
Code FBC2017/TP12014
3x8 = 2x3 II
4x6 =
CSI.
DEFL.
in (loc)
I/defi
Ud
TC 0.59
Vert(LL)
0.33 14-15
>999
240
BC 0.68
Vert(CT)
-0.64 14-15
>652
180
WB 0.59
Horz(CT)
0.13 10
n/a
n/a
Matrix -MS
LUMBER- BRACING -
TOP CHORD 2x4 SP M 30 TOP CHORD
BOT CHORD 2x4 SP M 30 BOT CHORD
WEBS 2x4 SP No.3
REACTIONS. (size) 2=0-8-0, 10=0-8-0
Max Horz 2=-179(LC 10)
Max Uplift 2=-775(LC 12), 10=-775(LC 12)
Max Grav 2=1399(LC 1), 10=1399(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-3404/1963, 3-5=-2807/1637, 5-6=-2801/1739, 6-7=2801/1739, 7-9=-2807/1637,
9-10=-3404/1963
BOT CHORD 2-17=-1724/3188, 15-17=-1724/3188, 14-15=-966/2053, 12-14=-1739/3188,
10-12=-1739/3188
WEBS 6-14=-560/968, 9-14=-681/524, 6-15=-560/968, 3-15=-681/524
Scale = 1:59.5
3x6 =
PLATES GRIP
MT20 244/190
Weight: 166 lb FT = 0%
Structural wood sheathing directly applied or 3-1-15 oc pudins.
Rigid ceiling directly applied or 5-2-15 oc bracing.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat,
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) 100.01b AC unit load placed on the top chord, 17-6-0 from left end, supported at two points, 5-0-0 apart.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other jive loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 775 lb uplift atjoint 2 and 775 lb uplift at
joint 10.
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 quality Criteria, DSB-89 and BCSI Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
1 N
I�
Jab
Truss
Truss Type
Oty
Ply
THE WINDSOR
T19781810
M_11392
B
COMMON
2
1
Job Reference o tional
Chambers Truss, Inc., Fart Pierce, FL 8.240 a Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:15 ZUZU Page 1
I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-5OwLjSh8?_IzjuFF2SVpOlbSRwk4sA4MJ57cmfzX)Gs
1-0-0 8-3-5 14-0-0 17-6-0 21'D 0 26-8-11 35-0-0 6-0
O-0 8-3-5 5.8-11 3 6-0 3-0-0 5 8-11 8-3-5 0-0
�1
0
4.00 12
3x6 =
Scale = 1:59.3
3x4 = 2x3 II 3x6 = 3x4 = 3x4 = 3x6 = 2x3 II 3x4 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Udefl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.34
Vert(LL) -0.11 14-15 >766 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.38
Vert(CT) -0.24 17-20 >715 180
BCLL 0.0
Rep Stress Incr YES
WB 0.63
Horz(CT) 0.03 10 n/a n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MS
Weight: 149 lb FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. All bearings 0-8-0.
(lb) - Max Horz 2=-179(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) except 2=-371(LC 12), 15=-453(LC 12), 14=-453(LC 12), 10=-371(LC
12)
Max Grav All reactions 250 lb or less at joint(s) except 2=602(LC 1), 15=844(LC 17), 14=840(LC 18), 10=602(LC
1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-945/572, 5-6=181/256, 6-7=-181/258, 9-10=-945/574
BOT CHORD 2-17=-407/878, 15-17=-407/878, 12-14=-393/858, 10-12=-393/858
WEBS 3-17=-5/301, 3-15=-819/591, 5-15=-277/325, 7-14=-277/326, 9-14=-819/592,
9-12=-5/301
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 17-6-0, Exterior(2) 17-6-0 to
21-0-0, Interior(1) 21-0-0 to 36-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip
DOL=1.60
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members, with BCDL = 10.Opsf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 371 lb uplift at joint 2, 453 lb uplift at
joint 15, 453 lb uplift at joint 14 and 371 lb uplift at joint 10.
® WARNING - Verify deslgn parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly Incorporate this design Into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTPlf quality Criteria, DSB-89 and SCSI Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cent 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
I N
0
Job
Truss
Truss Type
Oty
Ply
THE WINDSOR
T79781811
M11392
BHA
BOSTON HIP
1
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:17 2020 Page 1
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-2026BBiPXb7HzCPe9tXHTAgmFjM1 K3EfmPcjgXzXjGq
15-6-0 21.6-0
1-0-0 7-0-0 9-6-0 11-6-0 13-6-0 1 17-6.0 19-6-0 21-0-0 23-6-0 25-8-0 28-0-0 35.0-0 6.0 0
-0-0 7-0-0 2-6-0 2-0-0 2-0-0 0-6 1.6-0 2-0-0 2-0-0 1-6-0 2-0-0 2-0-0 2:2- 7-0-0 -0-0
Scale = 1:62.4
TOP CHORD MUST BE BRACED BY END JACKS,
ROOF DIAPHRAGM, OR PROPERLY CONNECTED---
PURLINS AS SPECIFIED.
3x6
648
5x12 =53 4 6
3
52
3x4 =
4.00 12 4x4 =
57 15 58 17
56 12 /\ 59
35 42 43 34 44 45
33
3x6 = 6x8 =
223x6x6
M20
=
2�1
5x122616
627
63
14
28 29 cS
tW
i�
46 47 48 32 49
31 50
51
30
6x8 =
34 =
3x4 =
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in (loc) Udefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.51
Vert(LL) 0.13 35-38 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.54
Vert(CT) -0.16 35-38 >999 180
BCLL 0.0
Rep Stress Incr NO
WB 0.65
Horz(CT) 0.04 28 n/a n/a
BCDL 10.0
Code FBC2017rrP12014
Matrix -MS
Weight: 208 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD Structural wood sheathing directly applied or 5-3-13 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2x4 SP No.3
WEBS 1 Row at midpt 3-33, 27-32
JOINTS 1 Brace at Jt(s): 11. 19, 16. 7, 23
REACTIONS. All bearings 0-8-0.
(lb) - Max Harz 2=179(LC 7)
Max Uplift All uplift 100 lb or less atjoint(s) except 2=-565(LC 8), 33=-1269(LC 8), 32=-1017(LC 8),
28=-434(LC 8)
Max Grav All reactions 250 lb or less at joints) except 2=812(LC 17), 33=1825(LC 1), 32=1529(LC 1).
28=626(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1692/1103, 3-4=-105/259, 27-28=-1129/710, 3=5=-441/520, 5-7=-436/514,
7-10=436/514, 10-11=436/514, 11-13=436/514, 13-16=4361614, 16-18=-4361514,
18-19=436/514, 19-21=-382/412, 21-23=-382/412, 23-25=-382/412, 25-27=-387/418
BOT CHORD 2-35=-939/1572, 33-35=-909/1484, 32-33=-382/400, 30-32=-575/1004, 28-30=-56811039
WEBS 3-35=-191/649, 27-30=0/451, 3-33=-2090/1523, 11-33=8101782, 19-32=772/745,
27-32=-148411044, 9-10=463/453, 20-21=-462/454
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
4) All plates are 2x3 MT20 unless otherwise indicated.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 565 lb uplift at joint 2, 1269 lb uplift at
joint 33, 1017 lb uplift at joint 32 and 434 lb uplift at joint 28.
8) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord.
9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 265 lb down and 381 lb up at
7-0-0, 158 lb down and 206 lb up at 9-0-12, 158 lb down and 206 lb up at 11-0-12, 158 lb down and 206 lb up at 13-0-12, 158 lb
down and 206 lb up at 15-0-12, 158 lb down and 206 lb up at 17-0-12, 158 lb down and 206 lb up at 17-11-4, 158 lb down and 206
lb up at 19-11-4, 158 lb down and 206 lb up at 21-11-4, 158 lb down and 206 lb up at 23-11-4, and 158 lb down and 206 lb up at
25-11-4, and 158 lb down and 206 lb up at 27-11.4 on top chord, and 373 lb down and 236 lb up at 7-0-0, 69 lb down at 9-0-12, 69
lb down at 11-0-12, 69 lb down at 13-0-12, 69 lb down at 15-0-12, 69 lb down at 17-0-12, 69 lb down at 17-11-4, 69 lb down at
19-11-4, 69 lb down at 21-11-4, 69 Ill down at 23-114, and 69 lb down at 25-11-4, and 69 lb down at 27-11-4 on bottom chord.
e eslg se action o 'such conhection eirice(s)`is the responsibilityof others: "--`-----"---`
®Q 2kNMieV� stag )dteadlORF„ItQad3rapp1fe7t-tie fimfoceLdtih®Iame; 6tffiFBSfr=t7( )G&bgd2ABEFORE USE.
DelgntfnWVartlile evp MiTek® connectors. This design is based only upon parameters shown, and Is for an Individual building component, not
a trNpq Aygt��isggtgjng designer must verify the applicability of design parameters and property incorporate this design into the overall
bull, i esi n. g i i Mot. prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing
Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
MiTek'
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
THE WINDSOR
T79781811
M11392
BHA
BOSTON HIP
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:17 2020 Page 2
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-202688iPXb?HzCPe9tXHTAgmFjM1 K3EfmPcjgXzXjGq
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 36-39=20, 1-3=-54, 3-15=-54, 15-27=54, 27-29=-54
Concentrated Loads (lb)
Vert: 35=-373(F) 30=-23(F) 42=-23(F) 43=-23(F)44=-23(F) 45=-23(F) 46=-23(F) 47=-23(F)48=-23(F) 49=-23(F) 50=-23(F) 51=-23(F) 52=-169(F) 53=-118(F)
54=-118(F) 55=-118(F) 56=-118(F) 57=-118(F) 58=118(F) 59=-118(F)60=-118(F) 61=-118(F) 62=-118(F) 63=-118(F)
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE M11.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing ��T2 k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/f Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T79781812
M11392
GRA
HIP
1
1
�THEWINDSOR
Job Reference (optional
L;namoers I russ, Inc., Fort Fierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:19 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYbI7yXOVouLyEj5gvQzXjGo
1-0-0 7-0-0 14-11-0 21-5-2 28-0.0 35-M 6-0-
-0-0 7-0-0 7-11-0 6-6-2 6-6-14 7-0-0 -0-0
5x12 MT18HS =
4.00 12 3x5 II 3x6 = 4x8 =
3 22 23 24 25 4 26 27 5 28 629 30 31 32
4x8 =
7
Scale = 1:60.3
15 33 34 14 35 13 36 37 38 1239 11 40 41 10
3x4 = 2x3 11 3x6 = 5x14 = 3x4 = 4x6 = 24 11 3x5 =
35-0-0
LOADING (psf)
TCLL 20.0
TCDL 7.0
BCLL 0.0
BCDL 10.0
SPACING- 2-0-0
Plate Grip DOL 1.25
Lumber DOL 1.25
Rep Stress Incr NO
Code FBC2017/TPI2014
CSI.
TC 0.94
BC 0.67
WB 1.00
Matrix -MS
DEFL. in (loc) Udefl Ud
Vert(LL) 0.30 10-21 >792 240
Vert(CT) -0.30 10-12 >812 180
Horz(CT) 0.09 8 n/a n/a
PLATES
MT20
MT18HS
Weight: 153 lb
GRIP
2441190
244/190
FT = 20%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 3-9-5 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 4-6-8 oc bracing.
WEBS 2x4 SP No.3 *Except*
WEBS
1 Row at midpt 6-13
4-13: 2x6 SP No.2
2 Rows at 1/3 pts 3-13
REACTIONS. (size) 2=0-8-0, 13=0-8-0, 8=0-8-0
Max Horz 2=-78(LC 6)
Max Uplift 2=-448(LC 8), 13=-2442(LC 8), 8=-1159(LC 8)
Max Grav 2=755(LC 17), 13=3223(LC 1), 8=1225(LC 18)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
TOP CHORD 2-3=-1534/729, 3-4=-1052/1347, 4-6=1052/1347, 6-7=-1946/1834, 7-8=2978/2565
BOT CHORD 2-15=-586/1423, 13-15=-596/1464, 12-13=-1710/1946, 10-12=-2359/2830,
8-10=-2329/2789
WEBS 3-15=-159/733, 3-13=-2917/1869, 4-13=-848/801, 6-13=-3504/3050, 6-12=-430/666,
7-12=-940/731, 7-10=489/690
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf, BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=5ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); porch right exposed; Lumber DOL=1.60 plate grip DOL=1.60
3) Provide adequate drainage to prevent water ponding.
This item has been
4) All plates are MT20 plates unless otherwise indicated.
electronically Signed and
5) This truss has been designed for a 10.0 psf bottom chord jive load nonconcurrent with any other live loads.
sealed by Albani, Thomas, PE
6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
USIn Digital Signature.
g a g g
will fit between the bottom chord and any other members.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 448 lb uplift at joint 2, 2442 lb uplift at
Printed copies of this
joint 13 and 1159 lb uplift at joint 8.
document are not considered
8) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 203 lb down and 329 lb up at
signed and sealed and the
7-0-0, 90 lb down and 155 lb up at 9-0-12, 90 lb down and 155 lb up at 11-0-12, 90 lb down and 155 lb up at 13-0-12, 90 lb down
signature must be verified
and 155 lb up at 15-0-12, 90 lb down and 155 lb up at 17-0-12, 90 lb down and 155 lb up at 17-11-4, 90 lb down and 155 lb up at
19-11-4, 90 lb down and 155 lb up at 21-11-4, 90 lb down and 155 lb up at 23-11-4, and 90 lb down and 155 lb up at 25-11-4, and
on any electronic copies.
203 lb down and 329 lb up at 28-0-0 on top chord, and 452 lb down and 263 lb up at 7-0-0, 63 lb down and 3 lb up at 9-0-12, 63 lb
Thomas A. Alban! PE No.39380
down and 3 lb up at 11-0-12, 63 lb down and 3 lb up at 13-0-12, 63 lb down and 3 lb up at 15-0-12, 63 lb down and 3 lb up at
MiTek USA, Inc. FL Cart 6634
17-0-12, 63 lb down and 3 lb up at 17-11-4, 63 lb down and 3 lb up at 19-11-4, 63 lb down and 3 lb up at 21-11-4, 63 lb down and
6904 Parke East Blvd. Tampa FL 33610
3 lb up at 23-11-4, and 63 lb down and 3 lb up at 25-11-4, and 452 lb down and 263 lb up at 27-11-4 on bottom chord. The
Date:
design/selection of such connection device(s) Is the responsibility of others.
March 24,2020
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
.......... _........... ........ ... ........ ...... ._...
ALQAi I1NCASE(SIj;si§rtp0dar&rs and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5119/2020 BEFORE USE.
DeiigntPnWgrg MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not
?a�e"2h
a truss system. Bef re ,as, the building designer must verify the applicability of design parameters and property Incorporate this design into the overall
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
MiTek'
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11nPH Quality Criteria, DSB-89 and BCS/ Building Component
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
6904 Parke East Blvd.
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE WINDSOR
T19781812
M11392
GRA
HIP
1
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:64:19 2020 Page 2
ID:_kfiGCA6bx7j2Sy1 HDXFw7ye3KX-_nAsZgkf3CG_CWZOHIZIYb17yXOVouLyEj5gvCizXjGo
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-3=-54, 3-7=54, 7-9=-54, 16-19=-20
Concentrated Loads (lb)
Vert: 3=-147(B)7=-147(B)15=-452(B)13=-40(B)4=-90(B)10=-452(B)22=-90(B)23=-90(B)24=-90(B)26=-90(B)27=-90(B)28=-90(B)30=-90(B)31=-90(B)
32=-90(B) 33=40(B) 34=-10(B) 35=40(13) 36=40(B) 37=40(B) 38=40(B) 39=40(B) 40=40(B) 41=-40(B)
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall HV 1 1•
building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiT®k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSb7PH Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd.
Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldod, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T19781813
M11392
J1
MONO TRUSS
8
1
�THEWINDSOR
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:19 2020 Page 1
ID:_kfiGCA6bx7j2Syl HDXFw7ye3KK-_nAsZgkf3CG_CWZOHIZIYbIBwXAho7vyEjSgvQzXjGo
1-0-0 1-0-0
3x4 =
Scale = 1:6.1
1-0-0
1-0-0
LOADING (psi)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/de8 Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TIC 0.18
Vert(LL) -0.00
5 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.02
Vert(CT) -0.00
5 >999 180
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) 0.00
4 n/a n/a
BCDL 10.0
Code FBC2017/TPI2014
Matrix -MP
Weight: 5 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 1-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=48(LC 12)
Max Uplift 3=-4(LC 9), 2=140(LC 12)
Max Grav 3=11(LC 17), 2=118(LC 1), 4=17(LC 12)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.0psf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions
shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 4 lb uplift at joint 3 and 140 lb uplift at
joint 2.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property Incorporate this design Into the overall
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek*
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
IYI�'r
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVfPII Quality Criteria, DSB-89 and BCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
City
Ply
THE WINDSOR
T19781814
M11392
J3
MONO TRUSS
8
1
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL
-0-0
3x4 =
8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:20 2020
3-0-0
3-0-0
Scale = 1:9.4
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) Udefl L/d
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.18
Vert(LL) 0.01
4-7 >999 240
MT20 244/190
TCDL 7.0
Lumber DOL 1.25
BC 0.19
Vert(CT) -0.01
4-7 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017frP12014
Matrix -MP
Weight: 11 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP No.3
TOP CHORD
Structural wood sheathing directly applied or 3-0-0 oc purlins.
BOT CHORD 2x4 SP No.3
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=85(LC 12)
Max Uplift 3=-54(LC 12), 2=-147(LC 12), 4=-4(LC 12)
Max Grav 3=64(LC 1), 2=173(LC 1), 4=50(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 2-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 54 lb uplift at joint 3, 147 lb uplift at joint
2 and 4 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6634
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an individual building component, not
HV
at
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall
building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
MiTek'
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVTP/f Qualify Criteria, DSB-89 and SCSI Building Component
6904 Parke East Blvd.
Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601
Tampa, FL 36610
Job
Truss
Truss Type
Oty
Ply
THE WINDSOR
T19781815
M11392
J5
MONO TRUSS
8
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:21 2020 Page 1
ID:_kflGCA6bx7j2Syl HDXFw7ye3KX-wAHc_WlvbgWiRpjPOibDeOrOoKiYG1 PFh 1 awzlzXjGm
5-0-0
1-0-0 5.0-0
3x4 =
5-0-0
5-0-0
LOADING (psf)
SPACING-
2-0-0
CSI.
DEFL.
in
(loc)
I/deft
L/d
TCLL 20.0
Plate Grip DOL
1.25
TC 0.73
Vert(LL)
0.07
4-7
>863
240
TCDL 7.0
Lumber DOL
1.25
BC 0.70
Vert(CT)
-0.06
4-7
>964
180
BCLL 0.0
Rep Stress Incr
YES
WB 0.00
Horz(CT)
-0.00
3
n/a
n/a
BCDL 10.0
Code FBC2017/rP12014
Matrix -MP
LUMBER -
TOP CHORD 2x4 SP No.3
BOT CHORD 2x4 SP No.3
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=123(LC 12)
Max Uplift 3=-104(LC 12), 2=-177(LC 12), 4=-9(LC 12)
Max Grav 3=115(LC 1), 2=243(LC 1), 4=87(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
Scale = 1:12.7
PLATES GRIP
MT20 2441190
Weight: 17 lb FT = 0%
BRACING -
TOP CHORD Structural wood sheathing directly applied or 5-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES-
1) Wind: ASCE 7-10: Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Interior(1) 2-6-0 to 4-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 3, 177 lb uplift at
joint 2 and 9lb uplift at joint4.
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Albani PE No.39380
MiTek USA, Inc. FL Cert 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/192020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall MiTek*
iT®k•
building design. Bracing indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the iVI
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TPH Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safetylnformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
oty
Ply
THE WINDSOR
T79781816
M11392
J7
MONO TRUSS
24
1
Job Reference (optional)
Chambers Truss, Inc., Fort Pierce, FL
1-0-0
3x4 =
8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 24 12:54:212020 Page 1
I D:_kfiGCA6bx7j2Syl HDXFw7ye3KX-wAHc_WlvbgWiRpjPOibDeOrSnKmPG 1 PFh1 awzlzXjGm
Scale: 3/4°=l'
7-0-0
7-0-0
Plate Offsets (X,Y)—
[2:0-1-14,Edge]
LOADING (psf)
SPACING- 2-0-0
CSI.
DEFL. in
(loc) I/defl Ud
PLATES GRIP
TCLL 20.0
Plate Grip DOL 1.25
TC 0.47
Vert(LL) 0.17
4-7 >494 240
MT20 2441190
TCDL 7.0
Lumber DOL 1.25
BC 0.39
Vert(CT) -0.19
4-7 >447 180
BCLL 0.0 '
Rep Stress Incr YES
WB 0.00
Horz(CT) -0.00
3 n/a n/a
BCDL 10.0
Code FBC2017frPI2014
Matrix -MP
Weight: 23 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical
Max Horz 2=161(LC 12)
Max Uplift 3=-153(LC 12), 2=-211(LC 12), 4=-12(LC 12)
Max Grav 3=165(LC 1), 2=315(LC 1), 4=125(LC 3)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-6-0, Intedor(1) 2-6-0 to 6-11-8 zone;C-C for
members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 153 lb uplift at joint 3, 211 lb uplift at
joint 2 and 12 lb uplift at joint 4.
This item has been
electronically signed and
sealed by Aibani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date:
March 24,2020
A WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII.7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and Is for an Individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall HV
building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing - MtTek*
is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the
fabrication. storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd.
Safety Inlormatlon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Job
Truss
Truss Type
Qty
Ply
T19781817
M11392
KJ7
MONO TRUSS
4
1
�THEWINDSOR
Job Reference o tional
Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Tue Mar 2412:54:22 2020 Page 1
ID:_kfiGCA6bx7j2Sy1HDXFw7ye3KX-OMr BsmXM7eZ3zlbyQ7SADNhnk9g?RvOwhJUWIzXjGI
-11-10 6-8-12 9-10-1
-5.0 6-8-12 3-1-5
Scale = 1:20.6
3x4 = 5
3x4 =
LOADING (psi)
SPACING-
2-0-0
CSI.
DEFL. in
(loc) Udefl Lid
PLATES GRIP
TCLL 20.0
Plate Grip DOL
1.25
TC 0.20
Vert(LL) -0.04
7-10 >999 240
MT20 2441190
TCDL 7.0
Lumber DOL
1.25
BC 0.26
Vert(CT) -0.08
7-10 >999 180
BCLL 0.0
Rep Stress Incr
NO
WB 0.24
Horz(CT) 0.01
5 n/a n/a
BCDL 10.0
Code FBC2017/TP12014
Matrix -MS
Weight: 38 lb FT = 0%
LUMBER-
BRACING -
TOP CHORD 2x4 SP M 30
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2x4 SP M 30
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2x4 SP No.3
REACTIONS. (size) 4=Mechanical, 2=0-11-5, 5=Mechanical
Max Horz 2=192(LC 8)
Max Uplift 4=-131(LC 8), 2=-262(LC 8), 5=-238(LC 8)
Max Grav 4=156(LC 13), 2=379(LC 1), 5=461(LC 1)
FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (Ib) or less except when shown.
TOP CHORD 2-3=-838/366
BOT CHORD 2-7=-487/798, 6-7=-487/798
WEBS 3-7=0/307, 3-6=-920/561
NOTES-
1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=15ft; B=70ft; L=35ft; eave=6ft; Cat.
II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide
will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift atjoint 4, 262 lb uplift at
joint 2 and 238 lb uplift at joint 5.
6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25
Uniform Loads (plf)
Vert: 1-2=-54
Trapezoidal Loads (plf)
Vert: 2=0(F=27, B=27)-to-4=-133(F=-39, B=-39), 8=0(F=10, B=10)-to-5=49(F=-15, B=-15)
This item has been
electronically signed and
sealed by Albani, Thomas, PE
using a Digital Signature.
Printed copies of this
document are not considered
signed and sealed and the
signature must be verified
on any electronic copies.
Thomas A. Alban! PE No.39380
MiTek USA, Inc. FL Cart 6834
6904 Parke East Blvd. Tampa FL 33610
Date;
March 24,2020
A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mil-7473 rev. 5/19/2020 BEFORE USE.
Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not
a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall r
building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M iTe k•
is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the
fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTPlf Quality Criteria, DSB-69 and BCSI Building Component 6904 Parke East Blvd.
Satetylnrormadon available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610
Symbols
PLATE LOCATION AND ORIENTATION
Center plate on joint unless x, y
offsets are indicated.
Dimensions are in ft-in-sixteenths.
Apply plates to both sides of truss
and fully embed teeth.
Ogle
For 4 x 2 orientation, locate
plates 0- 'lid' from outside
edge of truss.
This symbol indicates the
required direction of slots in
connector plates.
Plate location details available in MITek 20120
software or upon request.
PLATE SIZE
The first dimension is the plate
4 x 4 width measured perpendicular
to slots. Second dimension is
the length parallel to slots.
Indicated by symbol shown and/or
by text in the bracing section of the
output. Use T or I bracing
if indicated.
BEARING
Indicates location where bearings
(supports) occur. Icons vary but
reaction section indicates joint
number where bearings occur.
Min size shown is for crushing only.
Industry Standards:
ANSI/TPI1: National Design Specification for Metal
Plate Connected Wood Truss Construction.
DSB-89: Design Standard for Bracing.
BCSI: Building Component Safety Information,
Guide to Good Practice for Handling,
Installing & Bracing of Metal Plate
Connected Wood Trusses.
❑
O
2
O
EL
O
F-
Numbering System
6-4-8 dimensions shown in ft-in-sixteenths
(Drawings not to scale)
2 3
TOP CHORDS
8 7 6 5
JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE
AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO
THE LEFT.
CHORDS AND WEBS ARE IDENTIFIED BY END JOINT
NUMBERS/LETTERS.
PRODUCT CODE APPROVALS
[CC-ES.Reports:
ESR-1311, ESR-1352, ESR1988
ER-3907, ESR-2362, ESR-1397, ESR-3282
Trusses are designed for wind loads in the plane of the
truss unless otherwise shown.
Lumber design values are in accordance with ANSI/TPI 1
section 6.3 These truss designs rely on lumber values
established by others.
© 2012 MiTekO All Rights Reserved
,g
MiTek�
MITek Engineering Reference Sheet: MII-7473 rev. 5/19/2020
® General Safety Notes
Failure to Follow Could Cause Property
Damage or Personal Injury
1. Additional stability bracing for truss system, e.g.
diagonal or X-bracing, is always required. See BCSI.
2. Truss bracing must be designed by an engineer. For
wide truss spacing, individual lateral braces themselves
may require bracing, or alternative Tor I
bracing should be considered.
3. Never exceed the design loading shown and never
stack materials on inadequately braced trusses.
4. Provide copies of this truss design to the building
designer, erection supervisor, property owner and
all other interested parties.
5. Cut members to bear tightly against each other.
6. Place plates on each face of truss at each
joint and embed fully. Knots and wane at joint
locations are regulated by ANSI/rPI 1.
7. Design assumes trusses will be suitably protected from
the environment in accord with ANSI/rPI 1.
8. Unless otherwise noted, moisture content of lumber
shall not exceed 19 % at time of fabrication.
9. Unless expressly noted, this design is not applicable for
use with fire retardant, preservative treated, or green lumber.
10. Camber is a non-structural consideration and is the
responsibility of truss fabricator. General practice is to
camber for dead load deflection.
11. Plate type, size, orientation and location dimensions
indicated are minimum plating requirements.
12. Lumber used shall be of the species and size, and
in all respects,.equal to or better than that
specified.
13. Top chords must be sheathed or pudins provided at
spacing indicated on design.
14. Bottom chords require lateral bracing at 10 ft. spacing,
or less, if no ceiling is installed, unless otherwise noted.
15. Connections not shown are the responsibility of others.
16. Do not cut or alter truss member or plate without prior
approval of an engineer.
17. Install and load vertically unless indicated otherwise.
18. Use of green or treated lumber may pose unacceptable
environmental, health or performance risks. Consult with
project engineer before use.
19. Review all portions of this design (front, back, words
and pictures) before use. Reviewing pictures alone
is not sufficient.
20. Design assumes manufacture in accordance with
ANSI1TPI 1 Quality Criteria.
21.The design does not take into account any dynamic
or other loads other than those expressly stated.