HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNN�_THE GRAND CAR�LTOON�
Builder Name: WYNNE BUILDING COPR.
Street: ` CK� �►�
Permit Office: ST. LUCIE COUNTY
`J
City, State, Zip: PIERCE , FL,
Permit Number:
Owner: WYNNE BUILDING CROP
Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types_(1442.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1250.00 ft2
b. Frame - Wood, Adjacent
R=11.0 192.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 2
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1476.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1446.00 ft2
6. Conditioned floor area above grade (W) 1446
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area below grade (ft2) 0
cDucts
R_ 2
11
R ft2
7. Windows(.141.3 sqft.) Description Area
a. Sup: Attie, Rat: Attic, AH: Attic
6 250
a. U-Factor: Sgl, U=0:54 101.25 ft2
SHGC: SHGC=0.25
b. U-Factor: Sgl, U=0.55 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.25
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency .
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 3.832 ft.
Area Weighted Average SHGC: 0.250
14. Hot water systems
8. Floor Types (1445.5 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1445:50 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 46.69
Glass/Floor Area: 0.098
PASS
Total Baseline Loads: 48.09
hereby certify that the plans and specifications covered by
Review of.the plans and
this calculation are in compliance with the Florida Energy
Code.
specifications covered by this
calculation indicates compliance
with the Florida Energy Code.
PREPARED Ry.
Before construction is completed
DATE: 4-21-20210
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code'C,fl
. .
OWNER/AG NT•
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
-Compliance requires an Air Barrie and sulation Inspection Checklist.in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with a ve a ea g no r 0 A H50 (R402.4.1.2).
AFNIMED FOR
"'ODE COMPLIANCE
i;To LUCiE C.OUNTY
4/21/202010:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) p inteo;ftware Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE GRAND CARL Bedrooms: 2
Address Type:
Street Address
Building Type: User Conditioned Area: 1446
Lot #
Owner Name: WYNNE BUILDING CROP Total Stories: 1
Block/Subdivision:
# of Units:. 1 Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180
Street:
Permit Office: ST. LUCIE COUNTY Cross Ventilation: No
County:
St. Lucie.
Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No
City, State, Zip:
FT. PIERCE ;
Family Type: Single-family .
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location TMY Site 97.5 % 2.5 %
Winter
Summer Degree`Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299
62
Low
BLOCKS
Number Name Area Volume
1 . Entire House 1446 11568
SPACES
Number Name Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 BEDROOM 301 2408 No 0
1
1 Yes
Yes
Yes
2 WIC 63 504 No 0
1 No
Yes
Yes
3 M.BATH 56 448 No 0
1 Yes
Yes
. Yes
4 KITCHEN 192 1536 Yes 0
1 No
Yes
Yes
5 BATH 45 360 No 0
1 Yes
Yes
Yes
6 BEDROOM 2 204 1632 No 0
1
1 Yes
Yes
Yes
7 ENTRY 55 440 No 0
1 Yes
Yes
Yes
8 LAUNDRY 42 336 No 0
1 Yes
Yes
Yes
9 GREAT/DINING 488 3904 No 0
1 Yes
Yes
Yes
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
. Area
Joist R-Value
Tile . Wood
Carpet
1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0
301 ft2
___
0 1
0
2Slab-On-Grade Edge Insulatio WIC 1 ft 0
63 ft2
____
0 1
0
3 Slab -On -Grade Edge Insulatio M. BATH 8 ft 0
56 ft2
___
0 1
0
4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0
192 ft2
____
0 1
0
5 Slab -Oh -Grade Edge Insulatio BATH 5 ft 0
45 ft2
_-__
0 1,
0
6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0
203.5 ft2
___
0 1
0
7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0
55 ft2
___
0 1
0,
4/21/2020.10:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft
0
42 ft2
____
0
1
0
9 Slab -On -Grade Edge Insuiatio GREAT/DINING 46 ft 0
488 ft2
___
0
1
0
ROOF
/ Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
V # Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Gable or Shed Metal 1524 ft2
240 ft2
Light
N
0:6
No 0.9
No 0
18.4
ATTIC
V # Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCO
1 Full attic Vented
150
1446 ft2
N
N
CEILING
# Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 Under Attic (Vented) BEDROOM
30
Blown
301ft2
0.1
Wood
2 Under Attic (Vented) WIC
30 .
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented) M. BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented) KITCHEN
30
Blown
192 ft2
0.1
Wood
5 Under Attic (Vented) BATH
30
Blown
45 ft2
0.1
Wood
6 Under Attic (Vented) BEDROOM 2
30
Blown
204 ft2
0.1
Wood
7 Under Attic (Vented) ENTRY
30
Blown
55 ft2
0.1
Wood
8 Under Attic (Vented) LAUNDRY
30
Blown
42 ft2
0.1
Wood.
9 Under Attic (Vented) GREAT/DINING
30
Blown
488 ft2
0.1
Wood
10 Knee Wall (Vented) GREAT/DINING
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Space Cavity Width
Height
Sheathing Framing Solar Below
1. NE=>SW Exterior Concrete Block - Int InsuBEDR00M
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
2 SW=>NE Exterior Concrete Block - Int InsuBEDROOM
4.1 28
0 8
0
224.0 ft2
0
0
0.4.
0
3 NW=>SE Exterior Concrete Block - Int InsuBEDR00M
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
4 SW=>NE Exterior Concrete Block - Int Insul M. BATH
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
5 NE=>SW Exterior Concrete Block - Int Insul BATH
4.1 5
0 8
0
40.0 ft2
0
0
0.4
0
6 NE=>SW Exterior Concrete Block- Int InsSEDROOM 2
4.1 16
0 8
0
128.0 ft2
0
0
04'
0
_ 7 SE=>NW Exterior Concrete Block - Int InsBEDROOM 2
4.1 10
0 8
0
80.0 ft2
0
0
0.4
0
8 S=>N Exterior Concrete Block - Int Ins81EDROOM 2
4.1 4
3 8
0
34.0 ft2
0
0
0.4
0
9 SW=>NE Exterior Concrete Block - Int InsBIEDROOM 2
4.1 2
0 8
0
16.0 ft2
0
0
0.4
0
10 SE=>NW Exterior Concrete Block - Int Insul ENTRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
11 SW=>NE Exterior Concrete Block - Int lnsul ENTRY
4.1 1
0 8
0
8.0 ft2
0
0
0.4
0
12 SW=>NE Exterior Concrete Block - Int InsuLAUNDRY
4.1 6
0 8
0
48.0 ft2
0
0
0.4
0
13 NE=>SW Exterior -Concrete Block- Int Ins8REAT/DINT
4.1 26
0 8
0
208.0 ft2
0
0
0.4
0
14 NW=>SE Exterior Concrete Block - Int InsiGSREAT/DINT
4.1 20
0 8
0
160.0 ft2
0
0
0.4
0
4/21/2020 10:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY C14FCKLIST RFPdRT
WALLS
Adjacent
Space Cavity Width Height Sheathing Framing - Solar Below
15 N=>S Garage Frame - Wood
KITCHEN 11 24 8 192.0 ft2 0.23 0.4
0
DOORS
# Ornt
Door Type
Space
Storms U-Value Width Height
Ft In Ft In
Area
1 SE=>NW
Insulated
ENTRY
None .39 3 1 6 8
20.6 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/ Wall
V # Ornt ID Frame
Panes
NFRC
Overhang
U-Factor SHGC Imp Area Depth Separation Int Shade
Screening
1 NW=>SE 3 Metal
2 SW=>NE 4 Metal
3 SE=>NW 7 Metal
4 NE=>SW 13 Metal
5 NW=>SE14 Metal
Low-E Single
Low-E Single
Low-E Single
Low-E Single
Low-E Single.
Yes
Yes
Yes
Yes
Yes
0.54 0.25 N 32.9 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds
0.54 0.25 N 6.9 ft2 1 ft 0 in 1 ft 5 in None
0.54 0.25 N 24.0 ft2 6 ft 0 in 1 ft 5 in None
0.54 0.25 N 37.5 ft2 1 ft 0 in 1 ft 5 in None
0.55 0.25 N 40.0 ft2 8 ft 0 in 1 ft 5 in Drapes/blinds
Exterior 5
None
None
None
Exterior 5
GARAGE
# Floor Area
Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1 315ft2
315ft2
24ft 8ft 11
INFILTRATION
# Scope Method
SLA
CFM 50 ELA Egi-A ACH ACH 50
1 Whole house Proposed ACH(50) .000356
1349.6 74.09 139.34 .1233 7
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1 Electric Heat Pump/
Split
Singl HSPF:8.5 34.8 kBtu/hr 1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
Singl SEER: 15 34.8 kBtu/hr cfm 0.8 1
sys#1
HOT WATER SYSTEM
# System Type
SubType
Location
EF Cap Use SetPnt Conservation
1 Electric
None
Garage
0.97 50 gal 60.9 gal 120 deg None
4/21/2020.10:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
I
FORM R405-2017 WPHT RHMMARY'CHECKL1RT REPnRT
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
/ ---- Supply ---
---- Return --
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic .
6 250 ft2
Attic
65 ft2
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:
Cooling Jan Feb
Jan HFeb
Hr
Ma
Mar
Apr
f Appr
f
May
May
Jun X] Jul
f Jun 4 ] Jul
Aug
4 Au .
Sep
4 Sepp.
Oct
f
Nov
Nov
Dec
Dec
Venting
Ventin Jan Feb
Mar
[X] Apr
[
May.
[ Jun [ ]Jul
[ Aug
[ Se
.Oct
[X] Oct
Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours,
Schedule Type
1
2
3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78
78
78
78 78
78
78
80, 80
80
80
PM
80
80
78
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78
78
78
78 78
78
78
78 78
78
78
PM
78
78
78
78
78 78
78
78
78 78
78
78
Heating (WD) AM
66
66
66
66
66 68
68
68
68 68
68.
68
PM
68
68
68
68
'68 68
68
68
68 68
66
66
Heating (WEH) AM
66
66
66
66
66 68
68
68
68 68
68
68
PM
,68
68
68
68.
68 68
68
68
68 68
66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 Ibs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8 Ibs/sq.ft.
ft2
ft
0.3
DINING/GREAT R
Defauli(8 lbs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(81bs/scit.
ft2
ft
0.3
HALL
Default(8 lbs/sq:ft.
ft2
ft
0.3
FOYER
Default(8 lbs/s .ft.
ft2
ft
0.3
BEDROOM 3
4/21/2020 10:24 AM EnergyGauge® USA 6.0.02 (Rev. 1) - F16Res2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA,
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION -COMPONENT CRITERIA
i
Project Name: WYNNE THE GRAND CARLTON Builder Name: WYNNE BUILDING COPR.
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,. Permit Number:
Y
Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY
Design Location: FL, Fart Pierce
v
COMPONENT AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
The exterior thermal envelope contains a. continuous air barrier.
requirements
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
The air barrier in any dropped ceiling/soffit shall be aligned with
Ceiling/attic
The insulation in any PP 9 dropped ceiling/soffit
/soffit
the insulation and any gaps in the.alr.barder shall be sealed.
shall be aligned with the air barrier.
Access. openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls The junction of the foundation and sill :plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity,
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights The space between window/doorjambs and framing, and
and doors skylights and framing shall be sealed.
Rim joists Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be•installed.to
(including insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing
g cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of -floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations ,Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned s ace shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation Air sealing shall be provided between the garage and conditioned spac
3s.
Recessed lighting Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to, fit around wiring
and, plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall tubs shall separate them from the'showers. and tubs.
be insulated.
Electrical/phone box or The air barrier shall be installed behind electrical or communication
exterior walls boxes or air -sealed boxes shall be installed.
HVAC register boots HVAC register boots that penetrate building thermal envelope shall
be sealed to'the sub -floor or drywall.
Concealed When required'to be sealed, concealed fire sprinklers shall only be
sprinklers sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
I between fire snr'nkler cover niates and walls or ceilonas.
a. In addition, inspection of log walls shall be. in accordance with .the provisions of ICC-400.
4/21/2020 10:25 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index,.the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
2. Single-family or multiple -family 2. Single-family a) Supply ducts R 6.0
b) Return ducts R 6.0
c) AHU location Attic
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms
4.
2
5: Is this a worst case? (yes/no)
5.
Yes
6. Conditioned floor area (sq. ft.)
6.
1446
7. Windows, type and area .
a) U-factor:(weighted average)
7a.
0.543
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
c) Area
7c.
141.3
8. Skylights
a) U-factor:(weighted average)
8a.
NA
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (insulation R-value)
11.. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
13. Cooling system: Capacity 34.8
a) Split system SEER 15.0
b) Single package SEER
c) Ground/water source SEER/COP
d) Room unit/PTAC EER
e) Other
14. Heating system:
Capacity 34.8
a) Split system heat pump
HSPF 8.5
b) Single package heat pump HSPF
o) Electric resistance
COP
d) Gas furnace, natural gas
AFUE
e) Gas furnace, LPG
AFUE
f) Other
9a.
0.0
9b.
15. Water heating system
9c.
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG . EF
d) Solar system with tank EF
10A1.
e) Dedicated heat pump with.tank EF
10A2.
4.1
f) Heat recovery unit HeatRec%
g) Other
10131.
11.0
1062.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11a.
30.0
b) Cross ventilation
No
11b.
c) Whole house fan
No
11c.
19.0
d) Multizone cooling credit
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
"Label required by Section R303.1.3 of the Florida Building Code,' Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded): in. this home before final inspection. Otherwise, a new EPL
display card will .be completed based on installed code compliant features.
Builder Signature: _ Date:_X_Wk�
Address of New. Home: City/FL Zip: FT. PIERCE. FL t)`�S5?_
4/21/202010:24:57 AM EnergyGauge® USA 6.0.04 (Rev: 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1