Loading...
HomeMy WebLinkAbout SITE PHOTOMETRICS.pdfDPU231P.O.S.CO28680.0.00.00.00.00.10.10.10.20.20.20.20.30.20.20.20.20.20.20.20.20.20.20.20.20.20.20.20.30.30.51.02.23.73.33.73.2 0.0.00.00.00.10.10.10.20.30.40.60.60.60.40.30.30.30.30.30.30.30.30.30.30.30.30.30.30.40.50.71.22.15.9 0.0.00.00.10.10.10.20.41.11.81.91.91.41.00.70.50.40.40.40.40.40.40.40.50.50.40.40.50.50.71.01.72.45.6 0.0.00.00.10.10.20.31.23.43.74.65.23.11.81.20.90.70.70.70.70.70.70.70.80.80.80.80.80.81.01.21.96.2 0.0.00.10.10.10.20.62.34.35.55.85.9 0.0.00.10.10.10.20.82.34.46.1 0.0.00.10.10.10.30.72.46.13.02.6 0.0.00.10.10.10.30.71.84.13.23.32.7 0.0.00.10.10.10.30.61.22.315.314.84.14.83.5 0.0.00.10.10.10.20.40.81.417.28.47.34.0 0.0.00.10.10.10.20.30.61.015.25.02.7 0.0.00.10.10.10.20.30.50.911.95.63.0 0.0.00.10.10.10.20.30.50.98.55.53.0 0.0.00.10.10.10.20.30.51.06.95.22.8 0.0.00.10.10.20.20.30.51.16.08.78.17.53.9 0.0.10.10.10.20.30.40.51.116.016.815.15.04.73.4 0.0.10.10.20.20.30.50.61.014.316.012.72.72.82.3 0.0.10.10.20.50.91.01.01.013.013.09.77.414.519.019.919.113.613.915.42.91.21.21.1 0.0.10.30.71.63.13.72.81.97.510.29.94.23.51.00.60.5 0.0.30.61.53.13.94.73.96.410.17.68.16.01.00.50.3 0.0.41.12.96.05.66.57.89.96.611.01.10.50.2 0.0.51.310.210.26.910.11.10.50.2 0.0.51.27.77.03.74.44.46.912.49.30.90.40.2 0.0.41.14.94.25.65.26.66.98.97.25.95.96.56.56.66.15.34.54.34.13.75.30.60.30.1 0.0.41.12.12.32.32.42.52.73.23.84.94.95.04.03.33.43.83.93.93.63.12.72.62.63.15.06.07.62.00.60.30.20.1 0.0.40.70.91.11.41.61.41.11.21.62.63.83.72.51.41.11.01.11.21.21.10.90.91.21.52.12.32.22.62.31.50.60.30.20.10.1 4.47.15.8 3.86.78.4 2.54.06.18.2 5.63.32.31.81.51.41.41.41.41.41.41.41.51.61.61.51.61.71.72.02.63.97.65.95.0 8.18.68.26.45.14.03.53.43.43.23.33.33.23.23.43.53.83.33.33.73.22.53.04.65.05.55.1 8.66.66.58.411.010.79.610.410.99.810.111.010.09.710.79.77.77.98.19.78.75.33.82.72.7 6.18.15.88.119.331.731.525.331.533.326.929.533.628.826.832.929.215.210.712.511.911.59.16.13.1 3.85.84.910.428.622.614.414.016.310.75.4 2.44.04.610.430.624.915.515.618.918.114.211.1 1.92.94.19.728.123.616.116.414.515.3 1.93.04.28.219.331.031.125.430.431.625.728.132.428.727.333.230.218.713.210.211.210.5 2.24.65.27.410.913.414.412.511.010.69.59.911.412.614.414.914.412.08.88.47.87.2 2.15.59.811.613.014.412.17.14.94.13.84.04.97.011.615.014.213.211.38.45.95.6 2.56.89.813.815.514.69.85.53.82.82.62.93.95.69.315.116.214.311.18.85.66.08.99.9 2.57.910.413.913.410.45.74.13.23.13.54.66.010.313.911.29.85.25.25.65.64.0 2.05.68.711.215.29.36.25.15.96.57.17.97.79.815.89.97.64.44.03.83.22.2 1.43.16.111.012.414.212.77.75.13.93.62.01.3 1.62.13.75.97.28.57.96.65.14.83.12.1 3.43.03.13.23.75.05.75.68.49.08.35.62.5 5.36.24.15.34.44.75.45.04.87.514.312.711.97.12.7 3.35.97.87.86.56.54.45.78.06.57.94.74.87.412.216.713.89.03.2 2.96.66.96.07.76.34.36.06.18.79.711.713.98.52.7 3.24.53.63.93.610.49.39.47.04.51.6 2.07.74.5 CPY-FLAT-C MH: 12 CPY-FLAT-C MH: 12 XSPW MH: 12 XSPW MH: 12 XSPW MH: 12 XSPW MH: 12 XSPW MH: 12 XSPW MH: 12 XSPW MH: 12 XSPW MH: 12 XSPW MH: 12 XSPW MH: 12 CPY-FLAT-B MH: 15 CPY-FLAT-B MH: 15 CPY-FLAT-B MH: 15 CPY-FLAT-B MH: 15 CPY-FLAT-B MH: 15 CPY-FLAT-B MH: 15 XSPLG-4ME MH: 20 XSPLG-4ME MH: 20 XSPLG-4ME-2 MH: 20 XSPLG-4ME-2 MH: 20 XSPLG-4ME MH: 20 XSPLG-4ME MH: 20 XSPLG-4ME-2 MH: 20 XSPLG-4ME-2 MH: 20 XSPW MH: 12 XSPW MH: 12 XSPW MH: 12 XSPW MH: 12XSPW MH: 15 XSPW MH: 15 XSPW MH: 15 XSPW MH: 15 XSPW MH: 15 XSPW MH: 15 36 40 40 37 32 31 34 38 40 39 35 30 31 35 39 39 37 33 30 32 37 39 38 33 43 49 50 47 40 37 42 48 50 49 44 38 39 45 49 50 47 41 37 40 47 49 47 40 47 53 54 51 44 41 46 53 55 54 48 42 43 49 54 54 51 44 41 44 51 53 51 43 49 56 57 53 46 43 48 55 57 56 51 44 45 52 57 57 54 47 42 46 53 56 54 45 49 56 57 53 46 43 48 55 58 57 51 44 45 52 57 57 54 47 42 46 53 56 54 46 47 53 54 51 44 41 46 53 55 54 49 43 43 50 54 55 52 45 41 44 51 53 52 44 43 49 50 47 40 37 42 49 50 50 44 38 39 46 50 50 48 41 37 40 47 49 48 41 34 39 39 37 32 30 34 39 40 40 35 31 31 36 40 40 38 33 30 32 37 39 38 33 1 SITE PHOTOMETRICS N.T.S. XSPW-B-WM-3ME-4L-57K-UL-BZ BOM: Complete Part DescriptionBOM: Complete Part Description CPY250-B-DM-F-C-UL-BZ-57K-HZ04 SSS-4-7-17-CW-BS-OT-N-BZ PD-1H4 PD-2H4(90) CPY250-B-DM-F-B-UL-WH-57K-HZ24 XSPLG-D-HT-4ME-24L-57K-UL-BZ-N 08 04 04 12 20 Luminaire Schedule Symbol Qty Label Arrangement LMF Lum. Lumens Lum. Watts Part Number 24 CPY-FLAT-B SINGLE 1.000 12860 96 CPY250-B-DM-F-B-UL-WH-57K-HZ 4 CPY-FLAT-C SINGLE 1.000 4520 31 CPY250-B-DM-F-C-UL-BZ-57K-HZ 4 XSPLG-4ME SINGLE 1.000 23600 184 XSPLG-D-HT-4ME-24L-57K7-UL-BZ-N 4 XSPLG-4ME-2 2 @ 90°1.000 23600 184 XSPLG-D-HT-4ME-24L-57K7-UL-BZ-N 20 XSPW WALL MOUNT 1.000 4270 31 XSPW-B-WM-3ME-4L-57K-UL-BZ Calculation Summary (Footcandles calculated using predicted lumen values @ 50K hrs of operation) Label Units Avg Max Min Avg/Min Max/Min Canopy Fc 45.02 58 30 1.50 1.93 Grass and Property Spill Fc 1.41 19.9 0.0 N.A.N.A. Paved Area Fc 8.96 33.6 1.3 6.89 25.85 FIXTURE MOUNTING HEIGHTS AS SHOWN (8) SSS-4-7-17-CW-BS-OT-N-BZ (17' x 4" x 0.125" STEEL SQUARE POLE, TENON MOUNT) (4) PD-2H4(90) TWIN 90° TENON (4) PD-2H4(180) TWIN 180° TENON PROPOSED POLES MEET 180MPH SUSTAINED WIND LOADS POLES MOUNTED ON 3' BASE ADDITIONAL EQUIPMENT REQUIRED: *** CUSTOMER TO VERIFY ORDERING INFORMATION AND CATALOGUE NUMBER PRIOR TO PLACING ORDER ***N2 10 10 10 EXTERIOR LIGHTING GUIDELINES 1.EXTERIOR LIGHTING SHALL INCLUDE ALL PARKING, CANOPY AREAS, AND WALKS PROVIDED WITH LED LIGHTING, MINIMUM 18 FT. HIGH, UNLESS PROHIBITED BY CODE, WITH ADEQUATE ILLUMINATION TO PROVIDE AN AVERAGE MINIMUM ACCEPTABLE LEVEL OF 3 FOOT CANDLES IN THE PARKING LOT AS REQUIRED BY APPLICABLE CODES, REGULATIONS OR LAWS. 2.GASOLINE DISPENSING ISLANDS / CANOPIES SHALL BE ILLUMINATED TO AN AVERAGE MINIMUM ACCEPTABLE LEVEL OF 30 FOOT-CANDLES / 300 LUX 3.ENTRIES, HIGH TRAFFIC AREAS SUCH AS AIR AND WATER, THE DUMPSTER ,DRIVES AND PARKING SHALL BE ILLUMINATED TO AN AVERAGE MINIMUM ACCEPTABLE LEVEL OF 10 FOOT-CANDLE / 100 LUX 4.STORE TO CANOPY WALK-WAY TO HAVE AN AVERAGE MINIMUM ACCEPTABLE LEVEL OF 10 FOOT-CANDLE / 100 LUX 5.STOREFRONT PARKING TO HAVE AN AVERAGE MINIMUM ACCEPTABLE LEVEL OF 10 FOOT-CANDLE / 100 LUX 6.7-ELEVEN, INC AVERAGE MINIMUM ACCEPTABLE LEVEL OF ILLUMINATION FOR THE REST OF THE SITE IS 3 FOOT-CANDLE / 30 LUX 7.IF THE STORE DOES NOT HAVE SIDE WALL PARKING, THEN THE AVERAGE MINIMUM ACCEPTABLE LEVEL OF ILLUMINATION FOR THE BACKWALL AND SIDE OF STORE IS 8 FOOT-CANDLE / 80 LUX. 8.IF THE STORE DOES HAVE SIDE WALL PARKING, THEN THE AVERAGE MINIMUM ACCEPTABLE LEVEL OF ILLUMINATION FOR THAT SIDE OF STORE IS 10 FOOT-CANDLE / 100 LUX. 9.CALCULATION ZONE "PAVEMENT" TO BE THE DRIVABLE APPROACH AND WALKWAY NOT ALREADY DEFINED BY OTHER CALCULATION ZONES. 10.CALCULATION ZONE "SITE" TO BE ANY OTHER AREA NOT ALREADY DEFINED BY OTHER CALCULATION ZONES. 11.RATED OPERATING TEMPERATURE SHALL BE -40C TO 50C (-40F TO 122F). 12.LEDS TO BE 5,000 TO 5,800K COLOR TEMPERATURE DEPENDING ON THE LED FIXTURE APPLICATION 13.LED COLOR RENDERING INDEX (CRI) OF A MINIMUM 70 14.OPERATING VOLTAGE SHALL BE 120-277V, AT 50/60 HERTZ 15.WARRANTY SHALL BE A MINIMUM OF 5 YEARS INCLUDING THE POWER SUPPLY UNIT. 16.PROPOSED POLES TO MEET 140MPH SUSTAINED WIND LOADS.SHEET TITLECLIENT NAMEPROJECT NAMECHECKEDRELEASEDRAWNDATECPROJECT NO. COPYRIGHT - All reports, plans, specifications, computer files, field data, notes and other documents are instruments of service prepared by: Cuhaci & Peterson, (C & P) as instruments of service remain the property of C & P. C & P shall retain all common law, statutory and other reserved rights, including the copyright thereto. Any use or reproduction of this document without written permission from C & P is a violation of Federal copyright laws.1925 Prospect Ave.Orlando, FL 32814P (407) 661-9100P (407) 661-9101Florida Corporate Certificate #AA C000526Architects Engineers Planners219026202/28/20207-ELEVEN - FORT PIERCE, FL7310 INDRIO RDFORT PIERCE, FL CREIGHTON CONST.900 SW PINE ISLAND ROAD, SUITE 202CAPE CORAL, FL 3399101/12/20219 E2.4 SITE PHOTOMETRICSMFJSPEER REVIEW COMMENTS #2 03/31/2020PERMIT RE-SUBMISSION 07/10/2020OWNER CHANGES 10/06/2020LIGHT POLE UPDATE 01/12/20219210