Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
BW Res AeroTherm Series 50 to 80 gal
Residential AeroTherm™ Series Heat Pump Water Heater AeroTherm™ Heat Pump Model Features: ■ ENERGY STAR® Qualified—Meet or exceed requirements for ENERGY STAR® per the latest ENERGY STAR® criteria revision, as well as most utility rebate programs. ■ The AeroTherm™ Series Control Panel—Provides detailed diagnostic information including water heater fault codes, tank codes, need-to-assess codes, and heat pump codes. Additional functions allow you to monitor the status of temperature sensing thermistors and heating components. -- User-Friendly, Easy to Read Display. -- LED’s Clearly Indicate the Current Operating Mode. -- Display Communicates Current Status, Mode and Set Point, and Displays Error Messages When Applicable. ■ Operating Modes Offer Flexibility. -- Heat Pump (Only) Mode—Maximizes consumer savings. The most energy-efficient mode as it only utilizes the heat pump. -- Hybrid Mode—Saves while experiencing fast recovery. Hybrid mode is the factory setting combining heat pump efficiency and savings with recovery rates of standard electric when needed. -- Electric (Only) Mode—Operates like a standard electric water heater, and eliminates the air flow and sound from the heat pump system when preferred (fastest recovery time, but least energy efficient). -- Vacation Mode—Adjusts the temperature set point down to 50°F for extended periods of time. ■ Quiet Operation—Operating sound level of approximately 55 DBA. ■ Can Be Laid Down for Easier Transportation—Easy-to-open, protective packaging. ■ Easily Accessible Top Mounted Washable Air Filter—User is automatically alerted when the air filter needs to be cleaned. ■ Operating air temperature range of 35-120°F for the Heat Pump—(Unit operates in Standard/Electric Mode outside of this range). ■ Backup Electric Heating Elements. ■ Direct Heat Transfer with Immersed Elements—Transfers heat directly and efficiently to the water. Screw-in style. ■ Insulation System—2" (51mm) Non-CFC foam insulation covers the sides and top of the tank, reducing heat loss. This results in less energy consumption, improved efficiencies, and jacket rigidity. ■ Water Connections—3⁄4" (19mm) NPT factory-installed true dielectric fittings extend water heater life and simplify water line connections. ■ Factory-Installed Heat Traps—Design incorporates a flexible disk that reduces heat loss in piping and eliminates the potential for noise generation. ■ Protective Magnesium Anode Rod—Provides added protection against corrosion for long-term, trouble-free service. ■ T&P Relief Valve—Installed. ■ Low Restrictive Brass Drain Valve—Durable tamper proof design. ■ Design Certified to NSF/ANSI 372 (Lead Content). ■ Northern Climate Tier 3 Capable. ■ Optional Ducting Kit—Maximum duct length of 100 feet combined between inlet and exhaust. Photo is of RE2H50R10B 10-Year Limited Tank and Parts Warranty. For more information on warranty, please visit www.bradfordwhite.com For products installed in USA, Canada and Puerto Rico. Some states do not allow limitations on warranties. See complete copy of the warranty included with the heater. MANUFACTURED UNDER ONE OR MORE OF THE FOLLOWING U.S. PATENTS: 5,682,666; 7,634,976; 5,660,165; 5,954,492; 6,056,542; 6,935,280; 5,372,185; 5,485,879; 5,574,822; 7,971,560; 7,992,526; 6,684,821; 6,442,178; 7,334,419; 7,866,168; 7,270,087; 7,007,748; 5,596,952; 6,142,216; 7,699,026; 5,341,770; 7,337,517; 7,665,211; 7,665,210; 7,063,132; 7,063,133; 7,559,293; 7,900,589; 5,943,984; 8,082,888; 5,988,117; 7,621,238; 7,650,859; 5,761,379; 7,409,925; 5,277,171; 8,146,772; 7,458,341; 2,262,174. OTHER U.S. AND FOREIGN PATENT APPLICATIONS PENDING. CURRENT CANADIAN PATENTS: 2,314,845; 2,504,824; 2,108,186; 2,143,031; 2,409,271; 2,548,958; 2,112,515; 2,476,685; 2,239,007; 2,092,105; 2,107,012. 1900-A-0717 FEATURING: Printed in U.S.A.1900-A-0717 ©2017, Bradford White Corporation. All rights reserved. Ambler, PA For U.S. and Canada field service, contact your professional installer or local Bradford White sales representative. Sales 800-523-2931 l Fax 215-641-1670 / Technical Support 800-334-3393 l Fax 269-795-1089 l Warranty 800-531-2111 l Fax 269-795-1089 International: Telephone 215-641-9400 l Telefax 215-641-9750 / www.bradfordwhite.com Sales / Technical Support 866-690-0961 / 905-238-0100 l Fax 905-238-0105 / www.bradfordwhite.com AeroTherm™ Model C.E.C. Listed ModelNumber Approx.ShippingWeight lbs. EFloor toCold WaterConn. in. BJacketDia. in. AFloortoHeaterTopin. NominalCapacity RE2H50R10B RE2H80R10B 50 80 42 67 64 89 3.24 3.25 195 235 59 1/8 711/8 CFloortoWaterConn.in. 60 3/4 73 1/2 21 3/4 25 591/8 593/8 50 595/8 603/4 31/8383/4 50 3/8 FFloortoT&PConn.in. ModelNumber Approx.ShippingWeight kg. EFloor toCold WaterConn. mm. BJacketDia. mm. AFloortoHeaterTopmm.Liters NominalCapacity RE2H50R10B RE2H80R10B 189 303 Recovery90°F Rise U.S.GPH*U.S.Gal.Imp.Gal. 21 21 Imp.GPH* 18 18 Recovery50°C Rise Liters/*Hour 79 79 88 107 444 1502 1807 CFloortoWaterConn.mm. 1543 1867 DDistanceBetweenWaterConn.in. 8 8 DDistanceBetweenWaterConn.mm. 203 203 EFloortoCondensateConn.in. 46 3/4 58 3/4 EFloortoCondensateConn.mm. 1187 1492 552 635 79 FFloor to AnodeRod in. 161/2 F Floor to AnodeRod mm. GFloor toElectricalAccess in. 161/2 GFloor toElectricalAccess mm. 419 984 1280 FFloortoT&PConn.mm. FirstHourRating(Gal.) UniformEnergyFactor 242 303 3.24 3.25 FirstHourRating(Liters) 45 75 DOERatedStorageVolume(Gal.) 170 284 DOERatedStorageVolume(Liters) UniformEnergyFactor Residential Heat Pump Water Heater Meets NAECA Requirements General All models are UL listed. These heaters are wired inter-locking (Non-Simultaneous, Single Phase) 240V with 4500W upper element and 4000W lower element. All water connections are 3/4" NPT (19mm) and electrical connections are 1/2" NPT (13 mm). All models certified at 300 PSI test pressure (2068 kPa) and 150 PSI working pressure (1034 kPa.) Dimensions and specifications subject to change without notice in accordance with our policy of continuous product improvement. Suitable for Water (Potable) Heating. Toxic chemicals, such as those used for boiler treatment, shall NEVER be introduced into this system. This unit may NEVER be connected to any existing heating system or component(s) previously used with a non-potable water heating appliance. *Based on 4500/4000W, Non-Simultaneous operation. Uniform Energy Factor and First Hour Rating is based on the latest AHRI directory listings. AC D B E F Optional Ducting Kit: Part No. GVK8HS. Kit installation also requires - 8" insulated flexible ducting, ducting support hangers and exterior wall vents for inlet & outlet. Additional clearances required for ducting, refer to ducting kit instructions. PARTS INCLUDED Upper Inlet Duct Adapter Lower Inlet Duct Adapter Inlet Duct Filter Outlet Duct Adapter Drilling Screws (6) 8” Hose Clamps (2) Assembly Screws (8)