Loading...
HomeMy WebLinkAboutBoral Tile underlayment FL14317-R11Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Small FL14317-R11 Revision 2020 Pending FBC Approval Boral Rooting 7575 Irvine Center Drive Suite 100 Irvine, CA 92618 (801)380-6091 Rob!nArdersor@boral.com Anderson Robin RobinAnderson@bora Lcom Adrian Cooper 135 N W 20th Street Boca Raton, FL 33431 (954) 520-5461 acocpeer@mfnierlifetife.com 6s Contact Us BCIS Site Map Unks . Search i Category Roofing Subcategory Underlayments Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert J. M. Nieminen Evaluation Report Florida License PE-59166 Quality Assurance Entity A LLC Quality Assurance Contract Expiration Date 04/30/2023 Validated By Ichn W. Ifnezevich, PE Validation Checklist - Hardcopy Received -ertificate of Independence FL14317 R1I COI 2020 01 COI KirrmiNEN pdf teferenced Standard and Year (of Standard) Standard Year ASTM D1970 2015 FRSA/TRI 6th Edition 2018 7A5 103 zozo UL1897 2015 quivelence at Product Standards ertified By ections from the Code Product Approval Method Date Submitted Date Validated Date Pending FBC Approval nni of Products FL # Model, Number or Name 14317.1 Baral Roof Underfdyments Limits of Use Approved for use in JHl No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-210 Other: 1.) The design pressure in this application pertains to a particular underlayment system for use in tile roof systems. Refer to ER Section 5.8.2. 2.) Refer to ER Section 5 for Limits of Use. Method 1 Option D 11/25/202C 12/05/2020 12/12/2020 Description Roof underlayments: for use in prepared roof assemblies - Ynstallation Instructions FL14 17 R11 11 2020 11 25 FINAL ER B©RAL Un rlaym nYs FL1A 17 Rii.pdf Verified By: Robert 1. M. Nierrinen PE - 59166 Created by Independent Third Party: Yes Evaluation Reports FL14317 R11 AF 2020 11 25 FINAL ER BORAL Underlayments FL14317- R11.pdf Created by Independent Third Party: Yes Contact tfs :: Z501 Blair Stone Road Tal[ahassce FL 32349 Phpne:550-487-1824 The State of Florida is an AA/EEO employer, Copyright 2007-7013 State of Florida.:: Privacy Statement :: Accessibility Statement ;: Refund Statement Under Florida law, email addresses are public records. If you do not want your e-mail address released In response to a Publicrecordsrequest, do not send electronic Mail to this entity. Instead, contact the office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(l ), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an email address if they have one. The email5 provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 4SS, F.S., please dick here . Product ApFprroo'vvaa,�l Accepts: ril ® Jil E�hEEk Sec[1i•!tyMllhl S_ MIAMI-DADS COUNTY DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES RER PRODUCT CONTROL SECTION 08 BOARD AND CODE ADMINISTRATION DIVISION t 18Miami, Florida3 05 SW 26 Street,3175-2974 Room 2 M T (796) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economv Boral Roofing LLC. 7575 Irvine Center Drive, Suite 100 Irvine, CA 92618 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Mian-ii-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction, RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: BORAL TileSeal and BORAL MetalSeal HT LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically tenninate this NOA_ Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA# 18-0502.03 and consists of pages I through 4. The submitted documentation was reviewed by Alex Tigera. a DADE COUNTY � NOA No.: 19-0109.08 ' IExpiration Date: 08/02/23 Approval Date: 02/07/19 Page I of 4 ROOFING COMPONENT APPROVAL Cateiory: Roofing Sub-Catevrv: Underlayment Material: SBS PRODUCTS DESCRIPTION: Product BORAL TileSeal BORAL MetalSeal HT Boral Citadel Plus Dimensions 36" x 36' rolls 36" x 72' rolls Test Specification Product Description TAS 103 SBS self -adhering asphalt sheet material with a ASTM D1970 white glass re -enforced polyester surfacing fabric; for use as an uaderlayment in sloped roof assemblies. 36" x 36' rolls TAS 103 SBS self -adhering asphalt sheet material with a 36" x 72' rolls ASTM D1970 white glass re -enforced polyester surfacing fabric; for use as an underlayment in. sloped roof assemblies. 36" x 72' rolls ASTM D1970 SBS self -adhering asphalt sheet material with a poly film -facer; for use as a mid -ply underlayment in sloped roof assemblies. MANUFACTURIGN LOCATION: 1. Brentwood, NH. 2. Houston, TX. EVIDENCE SUBMITTED: Test A enc PR1 Construction Materials Technologies, LLC. Trinity ERD Test Identifier OCF-3 56-02-04 OCF-356-02-02 OCF-356-02-01 OCF-424-02-04 OCF-424-02-01 OCF424-02-03 BRLRF-SC l 6810.11.17 Test Name/Report Date ASTM D1623 07/25/18 TAS 103 07/24/18. ASTM D1970 07/26/18 ASTM D1623 07/25/19 ASTM D1970 07/25/18 TAS 103 07/25/18 ASTM D 1876 l l/28/17 MIAMI•bADECOUjf7Y NOA No.: 19-0109.08 Expiration Date: 08/02/23 Approval Date: 02/07/19 Page 2 of 4 APPROVED ASSEMBLIES: Deck Type 1: Wood, non -insulated Deck Description: 15/32" or greater plywood or wood plank System E(1): Anchor sheet mechanically fastened deck, membrane adhered. Base Sheet: One or more plies of ASTM D226 Type 11 or ASTM D2626 with a minimum 4" head lap and a 6" end lap mechanically fastened to deck with approved nails and tin caps 6" o.c, at the laps and two staggered. rows 12" o.c. the field of the roll. Ply Sheet Apply one layer of Boral Citadel Plus over Base sheet as per current approval. (Optional): Membrane: One or more plies of BORAL TileSeal or BORAL MetalSeal HT Underlayment with a minimurn 3" head lap and minimum 6" end lap. Place the first course of membrane parallel to the cave, rolling the membrane to obtain maximum contact. Remove the release membrane as the membrane is applied. Vertical strapping of the roof with BORAL TileSeal or BORAL MetalSeal HT Underlayment is acceptable. All end laps and laps without black selvage area shall be sealed under lap using an SBS modified mastic. Note: When used in Tile roof systems BORAL TileSeal or BORAL MetalSeal HT Underlayment shall be back nailed to deck with approved annular ring shank. nails and tin caps at a maximum 12" o.c. at the side laps. No nails or tin caps shall be exposed. Surfacing: Approved for Adhered Roof Tile using TILE BOND or AH-160, Mechanically Fastened Roof Tile, Metal Roofing, Wood Shake & Shingles, and Asphaltic Shingle assemblies. MIAMIK ADE COUNTY NOA No_: 19-0109.08 Expiration Date: 08/02/23 Approval Date: 02/07/1.9 Page 3 of 4 LIMITATIONS.: L Fire classification is not part of this acceptance. 2. This acceptance is for prepared roofing applications. Minimum deck requirements shall be in compliance with applicable building code. BORAL TileSeal and BORAL MetalSeal HT underlayment shall be installed in strict compliance with applicable Building Code. 3. BORAL TileSeal and 130RAL MetalSeal HT underlayment shall be applied to a smooth, clean and dry surface with deck free of irregularities. 4. BORAL TileSeal and BORAL MetalSeal HT underlayment shall not be applied over an existing roof membrane as a recover, but may be applied over a roofing Base/Anchor sheet underlayment. 5. BORAL TileSeal and BORAL MetalSeal HT underlayment shall not be left exposed as a temporary roof for longer than 180 days of application. 6. The standard maximum roof pitch for BORAL TileScal and BORAL MetalSeal HT underlayment shall be 6;12 when tiles are loaded directly to the BORAL TileSeal or BORAL MetalSeal HT underlayment; loading boards or battens are required on roof pitches greater than 6.12". 7. Refer to Prepared Roofing system Product Control Notice of Acceptance for listed approval of this product with specific prepared roofing products. 8. Tiles shall be stored on battens on roof pitches greater than 6.12". 9. BORAL TileSeal and BORAL MetalSeal HT underlayment may be used with any approved roof covering Notice of Acceptance listing BORAL TileSeal or BORAL MetalSeal HT underlayment as a component part of an assembly in the Notice of Acceptance. If BORAL TileSeal or BORAL MetalSeal HT underlayment is not listed, a request may be made to the Authority Having Jurisdiction (AHJ) or the Miami -Dade County Product Control Department for approval provided that appropriate documentation is provided to detail compatibility of the products, wind uplift resistance, and fire testing results, 10. All nails in the deck shall be carefully checked for protruding heads. Re -fasten any loose decking panels. Sweep the deck thoroughly to remove any dust and debris prior to application. 11. When applying the membrane in the valley, start at the low point and work to the high point, rolling the membrane from the center outward in both directions. For ridge applications, center the membrane and roll from the center outward in both directions. 12. Roll or broom the entire membrane surface so as to have 100% contact with the surface, giving special attention to overlap areas. 13. Flash vent pipes, stacks, chimneys and penetrations in compliance with Roof Assembly current Product Control Notice of Acceptance and applicable Building Code. 14. All protrusions or drains shall be initially taped with a 6" piece of underlayment. This target piece shall be pressed in place and formed around the protrusion to ensure a tight fit. A second layer of BORAL TileSeal or BORAL MetalSeal HT underlayment shall be applied over the underlayment, and sealed using an SBS modified mastic. 15. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. 16. All membranes or packaging shall bear the imprint or identifiable marking of the manufacturer's name or logo, city and state of manufacturing facility, and the following statement: "Miami -Dade County Product Control Approved" or the Miami -Dade County Product Control Seal as shown below MIAMI•DADE COUNTY END OF THIS ACCEPTANCE MIAMI•DADE COUNTY NOA No.: 19-0109.08 Expiration Date: 08/02/23 Approval Date: 02/07/19 Page 4 of 4