Loading...
HomeMy WebLinkAboutFL22513_R2_II__FL0211/ revision1)11 MASO! ! I ■ Ea WOOD -EDGE STEEL DOOR UNIT 6'-8" DOUBLE DOOR WITH / WITHOUT SIDELITES GENERAL NOTES 1. EVALUATED FOR USE IN LOCATIONS ADHERING TO THE FLORIDA BUILDING CODE AND WHERE PRESSURE REQUIREMENTS AS DETERMINED BY ASCE 7, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES, DOES NOT EXCEED THE DESIGN PRESSURES LISTED. 2. HURRICANE PROTECTIVE SYSTEM (SHUTTERS) IS NOT REQUIRED ON OPAQUE PANELS, BUT IS REQUIRED ON GLAZED SIDELITES. 3. WHEN INSTALLED IN THE WIND-BORNE DEBRIS REGION, EXCLUDING THE HIGH VELOCITY HURRICANE ZONE (HVHZ), HURRICANE PROTECTIVE SYSTEM IS NOT REQUIRED ON OPAQUE PANELS OR PANELS WITH IMPACT GLASS, BUT IS REQUIRED ON PANELS WITH NON -IMPACT GLASS. 4. POLYURETHANE CORE FLAME SPREAD INDEX OF 50 AND SMOKE DEVELOPED INDEX OF 60 PER ASTM E84. 5. PLASTICS TESTING: TEST DESCRIPTION DESIGNATION LITE FRAME SELF IGNITION TEMP ASTM D1929 842 'F > 650 'F RATE OF BURNING ASTM D635 1.28 IN/MIN SMOKE DENSITY ASTM D2843 70.2% TENSILE STRENGTH* ASTM D638 1 1.8% DIFF * COMPARATIVE TENSILE STRENGTH AFTER WEATHERING 4500 HOURS XENON ARC METHOD 1 SINGLE_ DOOR UNIT DOUBLE DOOR UNIT SINGLE DOOR UNIT WITH SIDELITE SINGLE DOOR UNIT WITH SIDELITE 21" MAX 149" MAX. OVERALL FRAME WIDTH 36.375" MAX. PANEL WIDTH W/ASTRAGAL DOUBLE DOOR UNIT WZSIDELITES Due SINGLE DOOR UNIT aZ2QELLjES 37.5" MAX. FRAME WIDTH DOUBLE DOOR UNIT WI IDELITES DESIGN PRESSURE RATING WHERE WATER REQUIRED TO INFILTRATION PERFORMANCE IS BE 15% OF DESIGN PRESSURE CONFIG MAX WIDTH INSWING OUTSWING INSWING BUMPER 0 S Z-SERIES 0 S HIGH DAM 0 S T4 0 S HP BUMP 0 S X 37.5 +70.0 -70.0 +70.0 -70.0 N A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 +50.0 -50.0 +50.0 -50.0 XX 74 +55.0 -55.0 +55.0 -55.0 N/A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 N A N/A OX or XO 75 +55.0 -55.0 +55.0 Z -55.0 N A +20.0 4-20.0 +30.0 4 -30.0 +50.0 -50.0 N A N A OXO 112.5 +55.0 -55.0 1 +55.0 4 -55.0 N A +20.0 4 -20.0 +30.0 4 -30.0 +50.0 4 -50.0 N/A N A OXXO 149 +55.0 Z -55.0 1 +55.0 Z -55.0 N/A +20.0 -20.0 +30.0 -30.0 +50.0 -50.0 N/A N/A TABLE OF CONTENTS SHEET # DESCRIPTION 1 TYPICAL ELEVATIONS & GENERAL NOTES 2 ANCHORING LOCATIONS & DETAILS 3 ANCHORING LOCATIONS & DETAILS ::exns �+ � ■ s ef';e_ KURT BALTHAZOR FLORIDA P.E. #56533 00 O p O�D O � J �O z cl-U J LU C/) �cl) Ld 0 Lw D o Z cry aoW r¢z O cps and Oco�N WWW z O0'Jp�j VNI�CW� =W O C� a 5. DATE: 5126117 SCALE: N. T. S. DWG. BY: SWS CHK. BY: DRAWING NO.: DWG-MA-FLO211-17 SHEET 1 OF 3 i3" SEE DETAI "^" 3" #8 x 2" #8x2" DETAIL "D" 6"3. LSEE DETAIL 3" }- "6" DETAIL "C" #10 x 1" �10 x I" co i 0 U a SEE DETAIL "D" J a G a Of W r 0 m �Wrm—ll pf DETAIL "E" ASTRAGAL ATTACH ASTRAGAL RETAINER BOLT STRIKE PLATE TO FRAME AS SHOWN. 0.962" 1 1 1.375" 1 1.437" T mtxDT C73T INSWING THRESHOLD BUMPER 0 S THRESHOLD T4 O/S THRESHOLD 1 1.482" T Z-SERIES O/S THRESHOLD 1 1.75" } 1.047" T 1 HIGH DAM O/S THRESHOLD 1 1.437" T HP O/S THRESHOLD HOT MELT ELASTOMER HOT MELT ELASTOMER 0 Lo N Lo ui 6" ;EE DETAIL C'• 6" ASTRAGAL RETAINER BOLT HOLE MUST BE DRILLED THROUGH THE THRESHOLD & INTO THE STRUCTURE DEEP ENOUGH FOR A 1.375" THROW DETAIL "F" ASTRAGAL #6 X 1-1/2" PHS BITE EXTEaLQa + ' INTERIOR TYPICAL GLAZING DETAIL NON -IMPACT GLASS c u x' l i r t•:s�-.• r .F cc � U pc) J Z � J O ZO R §iU �_u O Z CL2 LoLIJ O o- DATE: 5126117 SCALE: N.T.S. DWG. BY: SWS CHK. BY: DRAWING NO.: DWG—MA—FLO211-17 SHEET 2 OF 3 f MI All SEE DETAIL "C" SHT. 2 ATTACHMENT DETAIL 1. ANCHOR ANALYSIS FOR LOADING CONDITIONS PREPARED, SIGNED AND SEALED BY ROBERTO LOMAS, PE (FLORIDA #62514) WITH THE LOWEST (LEAST) FASTENER RATING FROM THE DIFFERENT FASTENERS BEING CONSIDERED FOR USE. JAMB, HEAD, AND THRESHOLD FASTENERS ANALYZED FOR THIS UNIT INCLUDE # 10 WOOD SCREWS OR 1 /4" TAPCONS. A PHYSICAL SHIM MUST BE PLACED IN SHIM SPACE AT EACH ANCHOR LOCATION. TAPCON EDGE DISTANCE MIN 2-1/2". WOOD SCREW EDGE DISTANCE MIN 3/4". 1.25" MIN 2. THE WOOD SCREW SINGLE SHEAR DESIGN VALUES COME FROM ANSI/AF&PA NDA FOR SOUTHERN PINE LUMBER AND ACHEIVEMENT OF 1-1/2" MINIMUM EMBEDMENT. THE TAPCON MUST ACHIEVE MINIMUM EMBEDMENT OF 1-1/4". 3. WOOD BUCKS BY OTHERS MUST BE ANCHORED PROPERLY TO TRANSFER LOADS TO STRUCTURE. 4. MINIMUM DESIGN VALUE STRENGTH OF ANCHORS 155 LBS. 3'- 0 N o � w U a SEE DETAIL En "D" SHT. 2 J 0 O 1.1 w M � in O Li 9 —7- 3" -� MA„ SHIM TYPICAL MASONRY ANCHOR INSTALLATION 6" — -- 6„ 3" 1 3" I` 3 i f s' s" � t0 0 W - - o_ U) J J — w 8 w io „ 3"f 3„6, 6 3"6" 6" 'MIN,. MAX" SHIM CL —I I— TYPICAL WOOD BUCK ANCHOR INSTALLATION 1. KWIKSET SERIES 400 GRADE 3 CYLINDRICAL LATCH AND SERIES 980 GRADE 1 DEADLOCK HARDWARE TO BE INSTALLED AT 5-1/2" CENTERLINE. 2. 4" X 4" FULL MORTISE BUTT HINGES. 1"X1/2" CORRUGATED #10X2" WOOD SCREW 3" FROM EACH END 6" FROM EACH END AND 7" OC AND 12" OC J ACRYLIC LATEX CAULK ACRYLIC j LATEX CAULK CL COMBINATION WOOD MULLION (BOXED) } COMBINATION WOOD MULLION (BOXED) (3) # 10X2-1 /2" WOOD SCREWS EACHEND I® INTEGRAL WOOD MULLION (CHS) a� Do C) C) J Q Q C) 0 cr- J z LO W 03 ? CL _2 Lo U O "-G jLLJ C z =a 0 0 W C, Q V O L.8 p C7 O m _J O Q C W 4, W Z 0 2 M.co 0 OQ 0 O I � D_ a 7 S. DATE: 5126117 SCALE: N.T.S. DWG. BY: SWS CHK. BY: DRAWING NO.: DWG-MA-FLO211-17 SHEET 3 OF 3