HomeMy WebLinkAboutFL14911_R11_II_SWD050 SS 2018-10-11SILVER LINE BUILDING PRODUCTS CORP. V1 SERIES170 SERIES SINGLE HUNG WINDOW (2127) (IMPACT RA TED) (H VHZ) GENERAL NOTES: 1. THE PRODUCT SHOWN HEREIN IS DESIGNED AND MANUFACTURED TO COMPLY WITH THE CURRENT EDITION FLORIDA BUILDING CODE (FBC), INCLUDING HVHZ AND HAS BEEN EVALUATED ACCORDING TO THE FOLLOWING: • TAS 201-94 • TAS 202-94 • TAS 203-94 • ASTM E330-02 • ASTM E1886-05 • ASTM E1996-06/09/12 • AAMA/WDMA/CSA 101/I.S.2/A440-08 2. ADEQUACY OF THE EXISTING STRUCTURAL CONCRETE/MASONRY, 2X FRAMING, AND METAL FRAMING AS A MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WITHSTANDING AND TRANSFERRING APPLIED PRODUCT LOADS TO THE FOUNDATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 3. 1X AND 2X BUCKS (WHEN USED) SHALL BE DESIGNED AND ANCHORED TO PROPERLY TRANSFER ALL LOADS TO THE STRUCTURE. BUCK DESIGN AND INSTALLATION IS THE RESPONSIBILITY OF THE ENGINEER OR ARCHITECT OF RECORD FOR THE PROJECT OF INSTALLATION. 4. THE INSTALLATION DETAILS DESCRIBED HEREIN ARE GENERIC AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT IN NON-HVHZ AREAS. IN HVHZ AREAS, ONETIME PRODUCT APPROVAL TO BE OBTAINED FROM MIAMI-DADE RER OR AHJ. 5. APPROVED IMPACT PROTECTIVE SYSTEM IS NOT REQUIRED ON THIS PRODUCT IN AREAS REQUIRING IMPACT RESISTANCE. 6. WINDOW FRAME MATERIAL: PVC 7. IN ACCORDANCE WITH THE CURRENT EDITION FBC, WOOD COMPONENTS SHALL HAVE BEEN PRESERVATIVE TREATED OR SHALL BE OF A DURABLE SPECIES AS DEFINED IN CHAPTER 23. 8. GLASS MEETS THE REQUIREMENTS OF ASTM E 1300 GLASS CHARTS. SEE SHEET 1 FOR GLAZING DETAILS. MAX OVERALL SIZE CONFIG. DESIGN MISSILE WIDTH HEIGHT PRESSURE IMPACT RATING 52" 73" O/X +55 / -60 PSF LMI/SMI TABLE OF CONTENTS SHEET REVISION SHEET DESCRIPTION 1 GENERAL NOTES & GLAZING DETAIL 2 ELEVATION & ANCHOR LAYOUTS 3 VERTICAL SECTIONS 4 HORIZONTAL SECTIONS S HORIZONTAL & VERTICAL SECTIONS, INSTALLATION NOTES & REINFORCEMENT DETAILS EXTERIOR STEELSPACER 1/8" OR 3/32" SETTING BLOCK GLAZING DETAIL 1 43/64" O.A. I.G. LAMINATED GLASS CONSISTING OF: 1/8" ANNEALED GLASS 7/32"STEEL SPACER 3/32" ANNEALED GLASS 0.090" SAFLEX PVB INTERLAYER BY EASTMAN CHEMICAL COMPANY 3/32" ANNEALED GLASS INTFRinR MIN. GLASS BITE 7/16" U 995 SEALANT NOTE: ALL GLAZING CONFIGURATIONS SHALL COMPLY WITH SAFETY GLAZING REQUIREMENTS OUTLINED IN CURRENT FBC AND ASTM E 1300 GLASS LOAD RESISTANCE. Silver Line byAndei4efi ONE SILVERLINE DRIVE NORTH BRUNSWICK, NJ 08902 W U _j (D ^ Z m e Z_ N N N � o m m n n o N N p2f N wLu o m Q m? a m 0 0 ° a W O (n F z Q J w w 3 O Z J a ccZ Z a a a x 3 Z u N H Z o o E W l7 N W Z 0 J w 3 N ? } m M = m r-I m <C w J W � a REMARKS BY I DATE AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. Digitally signpoft{l-IJ44 fF.,Norero, P.E Dat :'e 8 V. A •'38. ' :�•N .7 7 OF ; tYZ OT O 4DQ':'• w.�` � HERME� / IwoRFkb� •E.� FLORIDA P.E. No 73778 BUILDING DROPS, INC 398 E. DANIA BEACH BLVD. / 338 DANIA BEACH, FL 33004 FBPE CERT. OF AUTHORIZATION No. 29578 FL #: FL14911 DATE: 01.23.18 DWG. BY: CHK. BY: FIRHFN SCALE: NTS DWG. #: SW D050 SHEET: OF 5 a a MAX. O.A FRAME HEIGHT 73" MAX HEIGH MAX HEIGH MAX. O.A FRAME WIDTH 52" NAAV r% 1 n ELEVATION SINGLE HUNG WINDOW 3" MAX. 6" MAX. FROM O.C. CORNERS 6" MAX. O.C. 3" MAX. FROM CORNERS In "X" ANCHOR LAYOUT NAIL FIN - SINGLE HUNG WINDOW 6.25" MAX. FROM f CORNERS NOTE: ALL FASTENERS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK MUST BE FLAT HEAD 12.50" MAX. O.C. 6.25" MAX. FROM CORNERS .'X'. ANCHOR LAYOUT THROUGH FRAME - SINGLE HUNG WINDOW Silver Line brAnderseri ONE SILVERLINE DRIVE NORTH BRUNSWICK, N108902 w F U 0 Z M e a N N < Na d o a m o W v m LL \ 0 m w0 u N 0 Z (D m m o m 3 O Z N Q Z a z a x 3 p m W Z 0 J w 3 0= Z LU 0 ~ m I = � m J W w a Lli J Lu F a REMARKS BY I DATE AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. ```���Illlttllllff` �.� E S 'i :�•N .7 7 OF OT O // d HEdkki 1k111AFtW �1. FLORIDA P.E. No 73778 BUILDING DROPS, INC 398 E. DANIA BEACH BLVD. N 338 DANIA BEACH, FL 33004 FBPE CERT. OF AUTHORIZATION No. 29578 FL #: FL14911 DATE: 01.23.18 DWG. BY: BY: CHK. HR HFN SCALE: NTS DWG. #: SW D050 SHEET: a OF 5 H C7 w 2 w Q LL w X Q FXTFRI(1R SEE GLAZING DETAIL, SHEET 1 INTFRI(1R SEE GLAZING DETAIL, SHEET 1 A VERTICAL SECTION ��3j NAIL FIN w 2 w Q LL w X Q 2 SEE GLAZING DETAIL, SHEET 1 INTFRI(1R SEE GLAZING DETAIL, SHEET 1 g VERTICAL SECTION 3 THRU FRAME Silver Line brAnderseri ONE SILVERLINE DRIVE NORTH BRUNSWICK, N108902 w U m J (D^ Z M E 0 Z _ N N Z vi N o m n d o o v 0 Q LLI \ Lu S _ F == m n o O w 0 N Q w N W w v (D m m rn m O Z Q Z Z Z Q LL 3 U_ o0o Q m N DC z H w J w 3 w > } C� 2 CID r > < w m <<Q w J a w LZ REMARKS BY I DATE AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. ```�I%11111IIIIIff` % E O ,`� ••��� .... ICI L� E s • p 'i :�•N .7 7 OF ; tYZ OT O O L E� `e`�1 HEdI. 1lF! 114RFkb��1.� FLORIDA P.E. No 73778 BUILDING DROPS, INC 398 E. DANIA BEACH BLVD. # 338 DANIA BEACH, FL 33004 FBPE CERT. OF AUTHORIZATION No. 29578 FL #: FL14911 DATE: 01.23.18 DWG. BY: [CEH�KBY: FIR HFN SCALE: NITS DWG. #: SW D050 SHEET I OF 5 SECTION FOR BLOCK & TACKLE BALANCEI INTERIOR SEE GLAZING SEE GLAZING _ — / EXTERIOR D. L.O. MAX. FRAME WIDTH C HORIZONTAL SECTION 4 UPPER SASH SEE GLAZING SEE GLAZING DETAIL SHEET 1 INTERIOR DETAIL SHEET 1N EXTERIOR D. L.O. MAX. FRAME WIDTH p HORIZONTAL SECTION 4 LOWER SASH SECTION FOR r-CONSTANT FORCE 4NCERS Silver Line byAndi rts&ri ONE SILVERLINE DRIVE NORTH BRUNSWICK, N108902 w U -i z M E z_ N N rl z d o o v W O � m O m- a m w O w w w in Q J (D m m O Z F- Z z Z a z LL 3 N� m o o m �C z J w 3 w O } [� _ = m > o w <<Q w J a F w F- a REMARKS BY I DATE AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. ```���Illlttllllff` ,`� ••��� .... ICI L� E s • p 'i :�•N .7 7 OF HE114RFkb�•E.� FLORIDA P.E. No 73778 BUILDING DROPS, INC 398 E. DANIA BEACH BLVD. # 338 DANIA BEACH, FL 33004 FBPE CERT. OF AUTHORIZATION No. 29578 FL #: FL14911 DATE: 01.23.18 DWG. BY: CHK. BY: FIRHFN SCALE: NTS DWG. #: SW D050 SHEET 11 OF 5 a MIN. SUBSTRATE EDGE DISTANCE BY OTHERS MIN. EMBEDMENT PERIMETER SEALANT1/4" MAX. } BY OTHERS SHIM SPACE EXTERIOR IA INTERIOR q VERTICAL SECTION 6 THROUGH FRAME (HEAD) 79 1/4" MAX. SUBSTRATE\ SPACE BY OTHERS INTERIOR rorm Evil Ild Pilral ?I FXTFRInR 1/4" MAX. SHIM SPACE INTFRInR � PERIMETER SEALANT BY OTHERS EXTERIOR --SUBSTRATE BY OTHERS SCREW IN THE INTERIOR CHANNEL MIN. EDGE DISTANCE SCREW IN THE EXTERIOR CHANNEL MIN. EMBEDMENT g HORIZONTAL SECTION 6 THROUGH FRAME (JAMB) MIN. EMBEDMENT w 1u 0 U Z wQ SUBSTRATE BY OTHERS —7 1/4" MAX. SHIM SPACE INTERIOR C HORIZONTAL SECTION 6 NAIL FIN (HEAD) REINFORCEMENT DETAILS �{ �— 0.34" 0.83" 0.87" � 0.13" 0.77" 0 91, INTERIOR } 0.46" 0.45" 0.06" 0.87" O1 LOCK RAIL TOP 2 LOCK MEETING RAIL O BOTTOM LIFT RAIL & SASH ALUMINUM ALUMINUM ALUMINUM MIN. EDGE DISTANCE p HORIZONTAL SECTION E VERTICAL SECTION 6 NAIL FIN (JAMB) 6 MEETING STILE INSTALLATION NOTES: 1. ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH ANCHOR LOCATION SHOWN. 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED IS THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR PRODUCT INSTALLATION OF THE MAXIMUM SIZE LISTED. 3. INSTALL INDIVIDUAL INSTALLATION ANCHORS WITHIN A TOLERANCE OF ±1/2 INCH THE DEPICTED LOCATION & SPACING IN THE ANCHOR LAYOUT DETAILS (I.E., WITHOUT CONSIDERATION OF TOLERANCES). TOLERANCES ARE NOT CUMULATIVE FROM ONE INSTALLATION ANCHOR TO THE NEXT. 4. SHIM AS REQUIRED AT EACH INSTALLATION ANCHOR WITH LOAD BEARING SHIM(S). MAXIMUM ALLOWABLE SHIM STACK TO BE 3/8 INCH. SHIM WHERE SPACE OF 1/16 INCH OR GREATER OCCURS. SHIM(S) SHALL BE CONSTRUCTED OF HIGH DENSITY PLASTIC OR BETTER. 5. FOR MASONRY OR CONCRETE OPENINGS, 1X WOOD BUCK MAY BE USED (OPTIONAL AS LONG AS THE MINIMUM EMBEDMENT AND EDGE DISTANCE REQUIREMENTS ARE STILL MET WITHIN THE CORRESPONDING HOST SUBSTRATE. SEE GENERAL NOTE #3 ON SHEET 1 FOR MORE INFORMATION. 6. MINIMUM EMBEDMENT AND EDGE DISTANCE EXCLUDE WALL FINISHES, INCLUDING BUT NOT LIMITED TO STUCCO, FOAM, BRICK VENEER, AND SIDING. 7. INSTALLATION ANCHORS AND ASSOCIATED HARDWARE MUST BE MADE OF CORROSION RESISTANT MATERIAL OR HAVE A CORROSION RESISTANT COATING. 8. FOR HOLLOW BLOCK AND GROUT FILLED BLOCK, DO NOT INSTALL INSTALLATION ANCHORS INTO MORTAR JOINTS. EDGE DISTANCE IS MEASURED FROM FREE EDGE OF BLOCK OR EDGE OF MORTAR JOINT INTO FACE SHELL OF BLOCK. 9. INSTALLATION ANCHORS SHALL BE INSTALLED IN ACCORDANCE WITH ANCHOR MANUFACTURER'S INSTALLATION INSTRUCTIONS, AND ANCHORS SHALL NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS THAN THE MINIMUM STRENGTH SPECIFIED BY THE ANCHOR MANUFACTURER. ANCHOR SCHEDULE MIN. EDGE METHOD SUBSTRATE ANCHOR SCHEDULE MIN EMBEDMENT DISTANCE #8 WOOD SCREW WOOD: MIN. SG = 0.55 PAN HEAD 1.5" 0.75" NAILING FIN 3 THREADS MIN METAL: 18 GAUGE Steel, #8 TEK SCREW MIN. Fy = 33KSI PENETRATION BEYOND 0.50" METAL #10 PAN HEAD IN EXTERIOR CHANNEL 1.51, 0.75" WOOD: MIN. SG = 0.55 #10 FLAT HEAD IN THE INTERIOR CHANNEL 1.5" 0.75" 3 THREADS MIN #10 PAN HEAD IN PENETRATION BEYOND 0.501, METAL: 18 GAUGE Steel, EXTERIOR CHANNEL METAL THROUGH FRAME MIN. Fy = 33KSI #10 FLAT HEAD IN THE 3 THREADS MIN INTERIOR CHANNEL PENETRATION BEYOND 0.50" METAL 3/16" ITW TAPCON CONCRETE: fc=3000PSI FLAT HEAD 1.25" 1.75" MASONRY: CMU per ASTM 3/16" ITW TAPCON C90 MIN. 2000 PSI FLAT HEAD 1.25" 1.75" Silver Line byAndi ris&i ONE SILVERLINE DRIVE NORTH BRUNSWICK, N108902 w Z U J E z_ (V u06J vi 0 uW~ie o a N v (n N w H J I-w d 0 o o ?-a LL w � a 0 0 UZ� m m v m �umn-o OC Hzz O w O L') p cr w wua�N9 (7 m m o O Z j 2 Z Z z Q LL 3 06 u o o m C{ Z W m ZNZ CD } N = 0 z w r-I > N =CIO o lu <<Q a REMARKS BY I DATE AND MAY NOT REFLECT ACTUAL CONDITIONS FOR A SPECIFIC SITE. IF SITE CONDITIONS CAUSE INSTALLATION TO DEVIATE FROM THE REQUIREMENTS DETAILED HEREIN, A LICENSED ENGINEER OR ARCHITECT SHALL PREPARE SITE SPECIFIC DOCUMENTS FOR USE WITH THIS DOCUMENT. ```���Illlttllllff` O ''e :�•N .7 740 OF OT O 4UQ'�'� O HE lF! ljvfktb� •E.� FLORIDA P.E. No 73778 BUILDING DROPS, INC 398 E. DANIA BEACH BLVD. # 338 DANIA BEACH, FL 33004 FBPE CERT. OF AUTHORIZATION No. 29578 FL #: FL14911 DATE: 01.23.18 DWG. BY: CHK. BY: I I HFN SCALE: NTS SW D050 SHEET 10. FOR INSTALLATION ANCHORS ABOVE THE MEETING RAIL IN THE INTERIOR JAMB TRACK, USE FLATHEAD ANCHORS. OF 5