Loading...
HomeMy WebLinkAboutX PA-5 SS MIAMI-QADE MIAMI-DADE COUNTY V PRODUCT CONTROL SECTION I _ 11805 SW 26 Street,Room 208 J DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES(RER) Miami,Florida 33175-2474 ROOFING SYSTEM APPROVAL: (� BOARD AND CODE ADMINISTRATION DIVISION T(786)315-2590 F(786)315-2599 w V +�—, Lo NOTICE OF ACCEPTANCE (NOA) Category: Roofing APPROVED ASSEMBLIES: www.miamidade.¢ov/economy a1 � (�� Sub-Category: Metal,Panels(Non-Structural) System: Versaloc 1.5 Steel Panel 24 gauge 12"-20"wide E � ` V Gulf Coast Supply& Manufacturing LLC. Material: Steel E o 14429 SW 2nd Place, G30 Deck Type: Wood Deck Type: Wood,Non-insulated V o I j Newberry,FL. 32669 Maximum Design Pressure -189.25 psf. Deck Description: New Construction 19/32"or eater plywood or wood lank or for re-roofing "/32"or eater t� +' 0 P • in p Yam' p g UJ o ^ I plywood. SCOPE: TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: Slope Range: 2": 12" or greater +' I This NOA is being issued under the applicable rules and regulations governing the use of construction materials.The Test Product Maximum Uplift See Table A below _ documentation submitted has been reviewed and accepted by Miami-Dade County RER-Product Control Section to be Product Dimensions Specifications Description U1 U used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction(AHJ). Pressure: �41 v 3 Versaloc 1.5 Steel Length: various TAS 110 Corrosion resistant, Galvalume,preformed, Deck Attachment: In accordance with applicable Building Code,but in no case shall it be less than 8d annular Z This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section Panel Height: 1 %2" standing seam. Coated,prefinished panels. ring shank nails spaced as listed in Table A below. In reroofing,where the deck is less O (In Miami Dade County) and/or the AHJ(in areas other than Miami Dade County)reserve the right to have this product Width: 12"-20"(coverage) than 19/32"thick(Minimum 15/32")The above attachment method must be in addition to L or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner,the Thickness 24 ga. existing attachment. manufacturer will incur the expense of such testing and the AHJ may immediately revoke,modify, or suspend the use Min. Yield Strength: 53.3 ksi V of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,if it is Versaloc Clip Length: 3" Corrosion resistant 24 gauge, G90 galvanized Underlayment: Minimum underlayment shall be an ASTM D 226 Type 11 installed with a minimum 4" determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements Height: 1 1/2" steel clip. side-lap and 6"end-laps. Underlayment shall be fastened with corrosion resistant tin-caps of the applicable building code. Width: 1" and 12 gauge 1 /4 annular ring-shank nails, spaced 6 o.c. at all laps and two staggered Thickness 24 ga. rows 12"o.c. in the field of the roll or any approved underlayment having a current NOA. Cn p This product is approved as described herein, and has been designed to comply with the Florida Building Code Cn 1-- LLj Z w J Fire Barrier Board: Any approved fire barrier having a current NOA. Refer to a current fire directory listing for u.1 0 0 w w including the High Velocity Hurricane Zone of the Florida Building Code. w w ¢ m U � � EVIDENCE SUBMITTED: fire ratings of this roofing system assembly as well as the location of the fire barrier within J 0 DESCRIPTION: Versaloc 1.5 Steel Panel over Plywood deck the assembly. See Limitation# 1. Cn U (3 W ¢ O CD 0 Yam' Test Agency Test Identifier Test Name/Report Date Cn w Valleys: Valley construction shall be in compliance with Roofing Application Standard RAS 133 ¢ = 0 < m O � m z Z U LABELING: Each unit shall bear a permanent label with the manufacturer's name or too city, state and following Valspar Lab Form ASTM B 117 and with the current ublished installation instructions and details in Gulf Coast Su 1 "� Z ¢ � z w W — � p g � Y� g p ppy � � QD - 3 = W ¢ OJ statement: "Miami-Dade County Product Control Approved",unless otherwise noted herein. Valspar Lab Form ASTM G 23 Rollformer Association's Installation Manual. w — w � ¢ ~ w 0 I Cn Metal Panels and Install the "Versaloc 1.5 Steel Panel" including flashing penetrations valleys end laps and — Z Z z 0 � m w 0 Z RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change ' _ ¢ U ¢ in the applicable building code negatively affecting the performance of this product. PRI Construction Materials HTL-018-02-01 TAS 100 08/06/09 Accessories: accessories in compliance Gulf Coast Supply Rollformer Association's current,published U z _J J O W 0 W ~O J J Technologies installation instructions and in compliance with the minimum requirements detailed in If W — H = O W ¢ Hurricane Test Laboratory, Inc. 0527-1009-08 TAS 125 07/O1/09 g Application ¢ = J ¢ = Z = Z > TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the y, Roofing A 1lcation Standard RAS 133. m w z 0 U w J W OP 0 materials,use,and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for Panels shall be secured along the male rib with approved clips. Clips are to be fastened with O =In U_ _ C C� 0 ¢ z Q Z sales,advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of two corrosion resistant#10 x 1"pancake head screws of sufficient length to penetrate 0 LU W ¢ 0 z = w } � Q this NOA shall be cause for termination and removal of NOA. through the sheathing a minimum of 3/16". The panel clips were placed at a spacing listed in Z Z = O�C 0 z w CL W Table A below starting 3" from panel end. The female rib of panel is installed over the male Ir ¢ ~ 0 pC Ir z z O H C:) Z ADVERTISEMENT: The NOA number preceded by the words Miami-Dade County, Florida, and followed by the rib of panel. Panels are seamed as listed below in Table A. IW Z LI_ 0 In W U N w expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done Z O m Z Y w = w w Z 1-- in its entirety. TABLE A — U W — Iz = � Z W H U MAMUM DESIGN PRESSURES z Z > 0- 0 0 C3 �_ W XI INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and Roof Areas Field Perimeter and Corner' Perimeter and Corner' w 00 O Cn W 0 U _ _ shall be available for inspection at the job site at the request of the Building Official. Maximum Design Pressures -91.75 psf. -121.75 psf. -189.25 psf. 0 �z >- _ ¢ w LL 0 W Maximum Clip Spacing 16" o.c. 8" o.c. 8"o.c. pC ¢ 1-- Z 0 w = Z w This NOA renews NOA 14-0520.05 consists of pages 1 through 5. Panel Seam 901 degrees 901 degrees 1801 degrees H — — 0O U J O w = = O 0 UILmO � w ¢ oCcn The submitted documentation was reviewed by Freddy Semino Maximum Plywood 4" o.c. (at the plywood's edges) Er w z LL 0 0 > 10 Wp U w 1-- Fastening6"o.c. at the plywood's intermediate supports) LL. w O CO ¢ U) Q >- 0 w w NOA No.: 19-0814.04 I. Extrapolation shall not be allowed 0 co al W >_ Ir 2i 1-- 0 = 0 C0070 -DADE COUNTY Expiration Date: 10/02/24 Z H = ¢ ¢ _ ~ LL 0 ova Date: 09/19/19 0 Z O W LU Cc ~ _ PPZ 0- Page — [L 1of5 U � ¢ 0 } � NOA No.: 19-0814.04 O_ LL (n O MIAMI-DADE COUNTY Expiration Date: 10/02/24 (n 0 = J O W Z a- 1-- NOA _ 1 No.: 19-0814.04 Cn LL (� _ Approval Date: 09/19/19 >- 0 J O W cr J Page 2 of 5 MIAMI•DADE COUNTY Expiration Date: 10/02/24 L � ¢ m Z — = W 0- 0 ¢ ' 1 Approval Date: 09/19/19 O J Q m = w � J O 0 > Page 3of5 = m = l­- W UD W ¢ = Z 0 w � � z o Z J � � a_ 0 � zw ¢ ¢ Owe � 00 U2 0 � ~ � 0 ~ 0 00 wCnmoCw � � zwZOC OEQ W Z3:0 ¢ c~i� z W J 0 ¢ ¢ J Z ¢ 0 2i Z W = JZw = J0000w0 J H ¢ ¢ 2U ¢ UD � OCU U LIMITATIONS PROFILE DRAWINGS 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire LO ratings of this product. co 2. The maximum designed pressure listed herein shall be applicable to all roof pressure zones(i.e. field,perimeters, and corners).Neither rational analysis,nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones(i.e.perimeters,extended corners and corners). 1-1/2" LJO 3. Panels may be rolls formed in continuous lengths from eave to ridge. Maximum lengths shall be as described in Roofing Application Standard RAS 133 4. All panels shall be permanently labeled with the manufacturer's name and/or logo, city and state, and the following statement: "Miami-Dade County Product Control Approved" or with the Miami-Dade County Product Control Seal as seen below. All clips shall be permanently labeled with the manufacturer's name and/or logo, and/or model. U MIAMI•DADE COUNTY 12" - 20" J , . ..� J 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and -------- Rule 61 G20-3 of the Florida Administrative Code. 0- 6. Panels may be jobsite roll formed with machine model#'s S#8510804, S#10220207,S#2050711,S#2751012, S#9291105,and S#3270414 from Gulf Coast Supply Rollformer Association. J-11 O U z W 0L: I— _ V. U 6� 90DEGREE 180 D SEAM DEGREE f SEAM This report has been electronically signed and sealed using a Digital Signature. Printed copies of this document are not V! 1 1 considered signed and sealed and the Z L1._ signature must be verified on any electronic v CLIP CLIP copies. O _ PANEL PANEL PANEL PANEL %� R S/�,11��� r , Z �— iL (� No 64781 1 J PREP RED PREP/RED U-1 ROOF ROOF 0'... ,STATE O F ��`� Q O FASTENER FASTENER ♦ '� O P. END OF THIS ACCEPTANCE X NOA No.: 19-0814.04 ,',11111 J � � MIAMI-DADE COUNTY Expiration Date: 10/02/24 NOA No.: 19-0814.04 J 0 • MIAMI-DADECOUNTY Expiration Reviewed and Approved X Approval Date: 09/19/19 P Q X Page 4 of 5 Approval Date: 09/19/19 > Page 5 of 5 sco l} l+ r Digitally signed by scott r sanders 1212212020 1 1 :47:07 s Date: 2020.12.26 sander 20:31 :19 06'00' FA- 5 Scale