Loading...
HomeMy WebLinkAboutMule-Hide SA copy NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 1 of 29 MIAMI-DADE COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy Mule-Hide Products Co., Inc. 1195 Prince Hall Drive Beloit, WI 53511 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Mule-Hide Self-Adhered Roof System over Wood Decks LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #17-0824.11 and consists of pages 1 through 29. The submitted documentation was reviewed by Hamley Pacheco, P.E. NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 2 of 29 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub-Category: Modified Bitumen Materials SBS/APP/TPO Deck Type: Wood Maximum Design Pressure -112.5 psf TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT: TABLE 1 Product Dimensions Test Specification Product Description G2 Base Sheet 108’ x 36” ASTM D 4601, Type II Asphalt-coated fiberglass reinforced base sheet Nail Base 65’ 2” x 3’ 3-3/8” ASTM D 6163, Type I SBS modified asphalt coated fiberglass reinforced base sheet. SA Base Sheet 66’ 8” x 3’ 3-3/8” ASTM D 6163, Type I Self-adhered, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a smooth top surface. SA Base Sheet FR 66’ 8” x 3’ 3-3/8” ASTM D 6163, Type I Self-adhered, fire-rated, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a smooth top surface. Nail Base P 65’ 8” x 3’ 3-3/8” ASTM D 6164, Type I SBS modified asphalt coated polyester reinforced base sheet. SA-SBS Cap Sheet 32’ 10” x 3’ 3-3/8” ASTM D 6164, Type I Self-adhered, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a granule top surface. SA-SBS Cap Sheet FR 32’ 10” x 3’ 3-3/8” ASTM D 6164, Type I Self-adhered, fire-rated, polyester reinforced, SBS modified bitumen membrane with a self-adhering back face and a granule top surface. SA-SBS KoolCap® 32’ 10” x 3’ 3-3/8” ASTM D 6164, Type I Self-adhered, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a granule top surface. SA-SBS KoolCap® FR 32’ 10” x 3’ 3-3/8” ASTM D 6164, Type I Self-adhered, fire-rated, fiberglass reinforced, SBS modified bitumen membrane with a self-adhering back face and a granule top surface. APP Torch S 32’ 10” x 3’ 3-3/8” ASTM D 6222 Torch applied, polyester reinforced, APP modified bitumen membrane with a burn off polyethylene back face and a smooth or sanded top surface. SA-APP Cap Sheet 32’ 10” x 3’ 3-3/8” ASTM D 6222, Type I Self-adhered, polyester reinforced, APP modified bitumen membrane with a self-adhering back face and a granule top surface. SA-APP Cap Sheet FR 32’ 10” x 3’ 3-3/8” ASTM D 6222, Type I Self-adhered, fire-rated, polyester reinforced, APP modified bitumen membrane with a self-adhering back face and a granule top surface. NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 3 of 29 APPROVED INSULATIONS: TABLE 2 Product Name Product Description Manufacturer (With Current NOA) Mule-Hide Poly ISO 1 Polyisocyanurate foam insulation Polyglass USA, Inc. Poly ISO 2 Polyisocyanurate foam insulation Polyglass USA, Inc. ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp Structodek High Density Fiberboard Roof Insulation Wood fiber insulation board Blue Ridge Fiberboard, Inc. DensDeck, DensDeck Prime Gypsum insulation board Georgia-Pacific Gypsum LLC H-Shield Polyisocyanurate foam insulation Hunter Panels, LLC H-Shield CG Polyisocyanurate/perlite composite insulation Hunter Panels, LLC ENRGY-3 Polyisocyanurate foam insulation Johns Manville Corp. Fesco Board Expanded mineral fiber Johns Manville Corp. Multi-Max FA-3 Polyisocyanurate foam insulation Rmax Operating, LLC. SECUROCK Gypsum-Fiber Roof Board Fiber reinforced coverboard United States Gypsum Corporation APPROVED FASTENERS: TABLE 3 Fastener Number Product Name Product Description Dimensions Manufacturer (With Current NOA) 1. Dekfast DF-#12-PH3 Insulation fastener for wood, steel and concrete decks SFS Group USA, Inc. 2. Dekfast DF-#14-PH3 Insulation fastener for wood, steel and concrete decks Various SFS Group USA, Inc. 3. Dekfast DF-#15-PH3 Insulation fastener for wood, steel and concrete decks Various SFS Group USA, Inc. 4. Dekfast PLT-H-2-7/8 Galvalume hex stress plate. 2 7/8" x 3 ¼” SFS Group USA, Inc. 5. #14 Roofgrip Insulation and membrane fastener Various OMG, Inc. 6. Flat Bottom Metal Plate A2-SS aluminized steel plate 3" square OMG, Inc. 7. Mule-Hide HDP Fastener Insulation fastener for steel and wood decks Mule-Hide Products Co., Inc. 8. Mule-Hide 3” Metal Insulation Plate Round Galvalume AZ50 steel plate 3.23 round 3" round Mule-Hide Products Co., Inc. 9. #12 Standard Roofgrip Insulation fastener for wood, steel and concrete decks Various OMG, Inc. NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 4 of 29 APPROVED FASTENERS: TABLE 3 Fastener Number Product Name Product Description Dimensions Manufacturer (With Current NOA) 10. OMG 3 in. Ribbed Galvalume Plate (Flat) Galvalume stress plate. 3” round OMG, Inc. 11. OMG 3" Galvalume Steel Plate Galvalume stress plate. 3” round OMG, Inc. 12. Dekfast PLT-R-3 Galvalume stress plate. 3” round SFS Group USA, Inc. 13. Millennium One-Step Foamable Adhesive A two component, low rise, polyurethane foam adhesive H.B. Fuller Company 14. Millennium One Step Green Foamable Insulation Adhesive A two component, low rise, polyurethane foam adhesive H.B. Fuller Company 15. Millennium PG-1 Pump Grade Adhesive A two component, low rise, polyurethane foam adhesive H.B. Fuller Company 16. PG 100 A penetrating solution of solvent and a blend of selected asphalts used to promote adhesion. 1, 3, 5, 50, 55 gal, tube or 17 oz. spray can Polyglass USA, Inc. 17. PG 350 A fibered rubberized adhesive designed for use with modified bitumen membranes. 1, 3, 5, 50, 55 gal. or tube Polyglass USA, Inc. 18. PG 400 A thick, fibered, rubberized flashing cement for use in dry or damp conditions. 1, 3, 5, 50, 55 gal. or tube Polyglass USA, Inc. 19. PG 425 A thick, fibered, rubberized flashing cement for use in dry or damp conditions. 1, 3, 5, 50, 55 gal. or tube Polyglass USA, Inc. 20. PG 450 A thick, fibered, rubberized flashing cement. 1, 3, 5, 50, 55 gal. or tube Polyglass USA, Inc. 21. PG 500 A thick, fibered, rubberized flashing cement for use with modified bitumen membranes. 1, 3, 5, 50, 55 gal. or tube Polyglass USA, Inc. 22. POLYPLUS 35 A fibered rubberized adhesive designed for use with modified bitumen membranes. 1, 3, 5, 50, 55 gal. or tube Polyglass USA, Inc. 23. POLYPLUS 45 A thick, fibered, rubberized flashing cement. 1, 3, 5, 50, 55 gal. or tube Polyglass USA, Inc. 24. POLYPLUS 50 A thick, fibered, rubberized flashing cement for use with modified bitumen membranes. 1, 3, 5, 50, 55 gal. or tube Polyglass USA, Inc. 25. XtraFlex 10 A penetrating solution of solvent and a blend of selected asphalts used to promote adhesion. 1, 3, 5, 50, 55 gal, tube or 17 oz. spray can Polyglass USA, Inc. NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 5 of 29 APPROVED FASTENERS: TABLE 3 Fastener Number Product Name Product Description Dimensions Manufacturer (With Current NOA) 26. XtraFlex 35 A fibered rubberized adhesive designed for use with modified bitumen membranes. 1, 3, 5, 50, 55 gal. or tube Polyglass USA, Inc. 27. XtraFlex 50 Premium Modified Wet/Dry Cement A thick, fibered, rubberized flashing cement for use with modified bitumen membranes. 1, 3, 5, 50, 55 gal. or tube Polyglass USA, Inc. 28. WB-3000 A low-VOC, water-based acrylic primer to enhance adhesion of self- adhered membranes. 5 gallon pail Polyglass USA, Inc. NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 6 of 29 APPROVED SURFACING: TABLE 4 Chosen components must be applied according to manufacturer’s application instructions. Number Product Name Product Description Application Rate Specification Manufacturer 1. Gravel To be installed in a flood coat of approved asphalt at 60 lbs/sq 400 lbs/sq N/A Generic 2. v Slag To be installed in a flood coat of approved asphalt at 60 lbs/sq 300 lbs/sq N/A Generic 3. KM Acryl 15 A premium white or tinted elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 1-1½ gal/sq ASTM D6083 Polyglass USA, Inc. 4. KM Acryl 15 QS A premium white or tinted quick setting, elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 1-1½ gal/sq ASTM D6083 Polyglass USA, Inc. 5. KM Acryl 25 A premium white or tinted elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 1-1½ gal/sq ASTM D6083 Polyglass USA, Inc. 6. KM Acryl 25 QS A premium white or tinted quick setting, elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 1-1½ gal/sq ASTM D6083 Polyglass USA, Inc. 7. KM-PS #220 A single component, solvent, white or tinted, silicone coating. 1.25 gal/sq ASTM D6694 Polyglass USA, Inc. 8. KM-PS #250 A premium grade high solids, white or tinted, single component, moisture cure, fluid applied silicone coating 1.25 gal/sq ASTM D6694 Polyglass USA, Inc. 9. PG 300 An asphalt cutback fibered roof coating. May be applied by brush or spray equipment to rejuvenate aged BUR 1½-2 gal/sq ASTM D4479 Polyglass USA, Inc. NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 7 of 29 APPROVED SURFACING: TABLE 4 Chosen components must be applied according to manufacturer’s application instructions. Number Product Name Product Description Application Rate Specification Manufacturer 10. PG 600 Non-fibered aluminum roof coating. ½-1 gal/sq ASTM D2824 Type I Polyglass USA, Inc. 11. PG 650 Fibered aluminum roof coating. 1½-2 gal/sq ASTM D2824 Type III Polyglass USA, Inc. 12. PG 700 A premium white or tinted elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 1-1½ gal/sq ASTM D6083 Polyglass USA, Inc. 13. PG 700 QS A premium white or tinted quick setting, elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 1-1½ gal/sq ASTM D6083 Polyglass USA, Inc. 14. PG 800 An asphalt based, non-fibered clay emulsion 3 gal/sq in two coats ASTM D1227 Polyglass USA, Inc. 15. PolyBrite 70 A premium white or tinted elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 1-1½ gal/sq ASTM D6083 Polyglass USA, Inc. 16. PolyBrite 70 QS A premium white or tinted quick setting, elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 1-1½ gal/sq ASTM D6083 Polyglass USA, Inc. 17. PolyBrite 90 A premium grade high solids, white or tinted, single component, moisture cure, fluid applied silicone coating 1.25 gal/sq ASTM D6694 Polyglass USA, Inc. 18. PolyBrite 95 A single component, white or tinted, solvent, moisture cure silicone coating. 1.25 gal/sq ASTM D6694 Polyglass USA, Inc. 19. POLYPLUS 60 Non-fibered aluminum roof coating. ½-1 gal/sq ASTM D2824 Type I Polyglass USA, Inc. NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 8 of 29 APPROVED SURFACING: TABLE 4 Chosen components must be applied according to manufacturer’s application instructions. Number Product Name Product Description Application Rate Specification Manufacturer 20. POLYPLUS 65 Fibered aluminum roof coating. 1½-2 gal/sq ASTM D2824 Type III Polyglass USA, Inc. 21. XtraFlex 60 Aluminum Roof Coating Non-fibered aluminum roof coating. ½-1 gal/sq ASTM D2824 Type I Polyglass USA, Inc. 22. XtraFlex 65 Aluminum Roof Coating Fibered Fibered aluminum roof coating. 1½-2 gal/sq ASTM D2824 Type III Polyglass USA, Inc. 23. XtraFlex 70 Premium Acrylic FR Roof Coating A premium white or tinted elastomeric acrylic based roof coating (water-based). A polyester fabric may be used for reinforcement with this coating. 1-1½ gal/sq ASTM D6083 Polyglass USA, Inc. 24. XtraFlex 80 Emulsion Roof Coating An asphalt based, non-fibered clay emulsion 3 gal/sq in two coats ASTM D1227 Polyglass USA, Inc. 25. XtraFlex 30 Bituminous Roof Coating Fibered An asphalt cutback fibered roof coating. May be applied by brush or spray equipment to rejuvenate aged BUR 1½-2 gal/sq ASTM D4479 Polyglass USA, Inc. 26. XtraFlex SRC 8000 A single component, white or tinted, solvent, moisture cure silicone coating. 1.25 gal/sq ASTM D6694 Polyglass USA, Inc. 27. XtraFlex SRC 9600 A premium grade high solids, white or tinted, single component, moisture cure, fluid applied silicone coating 1.25 gal/sq ASTM D6694 Polyglass USA, Inc. NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 9 of 29 EVIDENCE SUBMITTED: Test Agency Test Name/Report Report No. Date Factory Mutual Research 4470 2W7A7.AM 08.04.94 Corporation 4450 2D5A9.AM 06.22.99 4470 3000857 01.12.00 4470 3004091 01.12.00 4470 3001334 02.15.00 4470 3014692 08.05.03 4450 3014751 08.27.03 4450 3019317 06.30.04 4470 3024311 11.01.06 4470 3012321 07.29.07 4470 3036182 07.31.09 4470 RR202591 10.22.15 Trinity | ERD TAS 114 11752.09.99-1 02.08.00 TAS 114 11751.05.03 05.30.03 TAS 117(B)-ASTM D903 020841.06.04 06.02.04 TAS 114 02762.03.05 03.30.05 TAS 114 02764.09.05 09.09.05 TAS 114 P1739.01.07 01.23.07 TAS 114 P1734.07.06-R1 02.27.07 TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07 TAS 114 & FM 4470 P7860SC.11.07 11.30.07 TAS 114(D) – ASTM D1876 P10070.10.08 10.09.08 TAS 114 (H) P13760.09.09 09.10.09 FM 4470 & TAS 114 P33970.03.11 03.15.11 ASTM D6163 / ASTM D 4601 P33960.03.11 03.15.11 ASTM D6163 P37590.03.13-2-R1 02.05.13 ASTM D6164 P37590.03.13-3A 03.06.13 TAS 114 P1738.02.07-R2 04.29.13 TAS 114 & TAS 117 (B) 11757.04.01-1-R1 04.30.13 ASTM D6509 P37590.03.13-1-R1 06.26.13 ASTM D6222 P37590.03.13-5-R1 07.01.13 ASTM D6164 P37590.07.13-1 07.02.13 TAS 114 & FM 4474 P41630.08.13 08.06.13 ASTM D4601 / TAS 117 P45940.09.13 09.04.13 ASTM D6222 P37590.09.13 09.12.13 ASTM D4601 / TAS 117 P45970.05.14 05.12.14 ASTM D6162 SC5170.05.15 05.08.15 ASTM D6162 SC5170.12.15-1 12.29.15 TAS 114 & FM 4474 PLYG-SC8905.05.16-1 05.17.16 TAS 114 & TAS 117 (B) 11757.12.00-1-R2 04.05.17 PRI Construction Materials ASTM D6222 PUSA-061-02-02 01.28.08 Technologies ASTM D6163 PUSA-064-02-02 02.27.08 ASTM D6222 PUSA-062-02-02 12.04.08 ASTM D6694 PUSA-134-02-01 05.16.14 ASTM D6694 PUSA-135-02-01 05.16.14 TAS 117(B) PUSA-202-02-01 05.08.17 FM 4470 & TAS 114 PUSA-202-02-02 05.23.17 NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 10 of 29 APPROVED ASSEMBLIES: Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c.. System Type A(1): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. Anchor Sheet: One ply of Nail Base, APP Torch S* or G2 Base Sheet, fastened to the deck as described below: *with OMG fasteners and Flat Bottom Metal Plates. Fastening #1: Attach base sheet using 11 ga. annular ring shank and 1-5/8” diameter tin caps spaced 8” o.c. in a 4” lap and 8” o.c. in three equally spaced staggered rows in the center of the sheet. Fastening #2: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates, Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 plates or Mule-Hide HDP Fasteners with Mule-Hide 3” Metal Insulation Plates, spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet. One or more of the following Base Insulation Layer (Optional) Insulation Fasteners (Table 3) Fastener Density/ft2 Poly ISO 2, Mule-Hide Poly ISO 1, ACFoam-II, ACFoam-III, H-Shield, Multi-Max FA-3, ENRGY-3 Minimum 1.5” thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of ap proved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 DensDeck, DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board Minimum ¼” thick N/A N/A Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Primer: (Optional) Apply WB-3000 at 1 gal. per 300 sq. ft. Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 11 of 29 Ply Sheet: (Optional) One or more plies of SA Base Sheet, SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See general limitation #7.) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 12 of 29 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c . System Type A(2): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. Anchor Sheet: One ply of Nail Base, Nail Base P, APP Torch S, G2 Base Sheet, fastened to the deck as described below: Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet. One or more of the following Base Insulation Layer (Optional) Insulation Fasteners (Table 3) Fastener Density/ft2 Poly ISO 2, Mule-Hide Poly ISO 1, ACFoam-II, ACFoam-III, H-Shield, Multi-Max FA-3, ENRGY-3 Minimum 1” thick N/A N/A Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 DensDeck, DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board Minimum ¼” thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be use d only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Primer: (Optional) Apply WB-3000 at 1 gal. per 300 sq. ft. Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. Ply Sheet: (Optional) One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -60 psf; (See general limitation #7.) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 13 of 29 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c. or #8 wood screws at 6” o.c . System Type A(3): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. Anchor Sheet: One ply of G2 Base Sheet fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. Annular ring shank and 1-5/8” diameter tin caps spaced 8” o.c. in a 4” lap and 8” o.c. in three equally spaced staggered rows in the center of the sheet. One of more of the following: Base Insulation Layer (Optional) Insulation Fasteners (Table 3) Fastener Density/ft2 Poly ISO 2, Mule-Hide Poly ISO 1, ACFoam-II, ACFoam-III, H-Shield, Multi-Max FA-3, ENRGY-3 Minimum 1” thick N/A N/A Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers wit h a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board Minimum ¼” thick N/A N/A Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the EVT range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composit e insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Primer: (Optional) Apply WB-3000 at 1 gal. per 300 sq. ft. Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. Ply Sheet: (Optional) One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See general limitation #7.) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 14 of 29 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank fastened at 24” spans with #8 wood screws at 6” o.c. System Type A(4): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is subsequently adhered to insulation. All General and System Limitations apply. Anchor Sheet: One ply of Nail Base or Nail Base P, fastened as below: Fastening: 12 ga. Annular ring shank nails and 1-5/8” tin-caps attached 6” o.c. in 4” lap and 6” o.c. in four equally spaced staggered rows. Base Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 ACFoam-II, Poly ISO 2, ACFoam-III, H-Shield, Mule-Hide Poly ISO 1, H-Shield CG, Multi-Max FA-3, ENRGY 3 Minimum 1” thick N/A N/A Note: All insulation shall be adhered to the anchor sheet with Millennium One-Step Foamable Adhesive, Millennium One Step Green Foamable Insulation Adhesive or Millennium PG-1 Pump Grade Adhesive applied over rows of tin-caps in continuous rows 7” o.c. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed with the polyisocyanurate side facing down. Primer: (Optional) Apply WB-3000 at 1 gal. per 300 sq. ft. Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. Ply Sheet: (Optional) One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -60 psf; (See general limitation #7.) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 15 of 29 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: Min. 19/32" plywood (15/32" for re-roof) or wood plank, fastened at 24” spans with 8d common nails at 6” o.c. System Type C(1): All layers of insulation are mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. One or more of the following Base Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1.0” thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulati on attachment. Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 SECUROCK Gypsum-Fiber Roof Board Minimum ¼” thick 2 with 4 or 12; 5 with 6, 10 or 11; 7 with 8 1:2 ft² DensDeck Prime Minimum ¼” thick 2 with 4; 5 with 6 or 11; 7 with 8 1:2 ft² Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: (Optional) Apply WB-3000 at 1 gal. per 300 sq. ft. Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. Ply Sheet: (Optional) One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet FR, SA-APP Cap Sheet FR or SA-SBS KoolCap® FR, self- adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -45 psf; (See General limitation #7.) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 16 of 29 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails or wood screws at 4” o.c. System Type C(2): All layers of insulation are mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. One or more of the following Base Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1.5” thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Structodek High Density Fiberboard Roof Insulation Minimum ½” thick 2 with 4 1:1.33 ft² DensDeck Minimum ¼” thick 2 with 4 1:1.33 ft² Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: (Optional) Apply WB-3000 at 1 gal. per 300 sq. ft. to DensDeck prior to application of self-adhered base sheets. Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. Ply Sheet: (Optional) One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -67.5 psf; (See General limitation #7.) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 17 of 29 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c. System Type C(3): All layers of insulation are mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. One or more layers of the following: Base Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1.5” thick N/A N/A Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Top Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Structodek High Density Fiberboard Roof Insulation Minimum ½” thick 2 with 4 1:1.33 ft² DensDeck Minimum ¼” thick 2 with 4 1:1.33 ft² Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: (Optional) Apply WB-3000 at 1 gal. per 300 sq. ft. to DensDeck prior to application of self-adhered base sheets. Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. Ply Sheet: (Optional) One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -67.5 psf; (See General limitation #7.) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 18 of 29 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with wood screws at 6” o.c. System Type C(4): All layers of insulation are mechanically attached to roof deck. Membranes subsequently adhered to insulation. All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code requirements and are field fabricated utilizing the approved membranes listed in Table 1. One or more of the following: Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 ENRGY 3, H-Shield, Mule-Hide Poly ISO 1, ACFoam-II, Poly ISO 2 Minimum 1.5” thick 2 with 4; 7 with 8 1:1.33 ft² Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation attachment. Primer: (Optional) Apply WB-3000 at 1 gal. per 300 sq. ft. Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered. Ply Sheet: (Optional) One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -82.5 psf; (See General limitation #7.) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 19 of 29 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c. System Type D(1): All insulation is loosed laid with preliminary attachment to deck. Base sheet is subsequently mechanically fastened through insulation to the roof deck. Membranes subsequently adhered. All General and System Limitations apply. One or more layers of the following: Base Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1” thick N/A N/A Top Insulation Layer (Optional) Insulation Fasteners (Table 3) Fastener Density/ft2 Fesco Board Minimum ¾” thick N/A N/A Structodek High Density Fiberboard Roof Insulation Minimum ½” thick N/A N/A DensDeck, DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board Minimum ¼” thick N/A N/A Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below: Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates, Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8 plates, or Mule-Hide HDP Fasteners with Mule-Hide 3” Metal Insulation Plates, spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See General limitation #7.) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 20 of 29 Membrane Type: SBS/APP Deck Type 1I: Wood, Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c. System Type D(2): All insulation is loosed laid with preliminary attachment to deck. Base sheet is subsequently mechanically fastened through insulation to the roof deck. Membranes subsequently adhered. All General and System Limitations apply. One or more layers of the following: Base Insulation Layer Insulation Fasteners (Table 3) Fastener Density/ft2 Any approved Polyisocyanurate listed in Table 2 Minimum 1” thick N/A N/A Top Insulation Layer (Optional) Insulation Fasteners (Table 3) Fastener Density/ft2 Fesco Board Minimum ¾” thick N/A N/A Structodek High Density Fiberboard Roof Insulation Minimum ½” thick N/A N/A DensDeck, DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board Minimum ¼” thick N/A N/A Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft., and four fasteners for any insulation board having no dimension greater than 8 ft. Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below: Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, , self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -60 psf; (See General limitation #7.) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 21 of 29 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c. or #8 wood screws at 6” o.c. System Type E(1): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8” diameter tin caps spaced 8” o.c. in a 4” lap and 8” o.c. in three equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See General limitation #7.). NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 22 of 29 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d ring shank nails at 6” o.c. at edges and intermediate supports. System Type E(2): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base, fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. annular grooved shank and 1” diameter caps spaced 6” o.c. in a 3” lap and 6” o.c. in four equally spaced staggered center rows. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See General Limitation #7) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 23 of 29 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c. or #8 wood screws at 6” o.c System Type E(3): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below: Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet, SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See General Limitation #7) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 24 of 29 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c. or #8 wood screws at 6” o.c . System Type E(4): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below: Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8” diameter tin caps spaced 8” o.c. in a 4” lap and 8” o.c. in three equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -52.5 psf; (See General Limitation #7) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 25 of 29 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c. System Type E(5): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base, fastened to the deck as described below: Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates, Dekfast DF-#14-PH3 with Dekfast PLT-H-2-7/8, or Mule-Hide HDP Fasteners with Mule-Hide 3” Metal Insulation Plates, spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -60 psf; (See General limitation #7.). NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 26 of 29 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24” o.c. and to blocking members spaced 48” o.c. with TruFast TP #10x2-7/8” screws spaced 6” o.c. System Type E(6): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below: Fastening: Attach base sheet using 12 ga. annular ring shank nails and 1-5/8” diameter tin caps spaced 4” o.c. in a 4” lap and 4” o.c. in four equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -97.5 psf; (See General Limitation #7) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 27 of 29 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24” o.c. and to blocking members spaced 48” o.c. with #10x3” wood screws spaced 6” o.c. System Type E(7): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below: Fastening: Attach base sheet using 12 ga. ring shank nails and tin caps spaced 4” o.c. in a 4” lap and 4” o.c. in four equally spaced staggered rows in the center of the sheet. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -97.5 psf; With SA Base Sheet or SA Base Sheet FR (See General limitation #7.) -112.5 psf; With all other base sheet options (See General limitation #7.) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 28 of 29 Membrane Type: SBS/APP Deck Type 1: Wood, Non-Insulated Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24” o.c. with #8x3” wood screws spaced 6” o.c. System Type E(8): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered. All General and System Limitations apply. Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below: Fastening: Attach base sheet using 12 ga. annular ring shanked nails and 1-5/8” tin-caps 6” o.c. in 4” lap and 6” o.c. in four equally spaced staggered rows. Tin-caps are primed with PG 100 or XtraFlex 10. Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered. Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered. Surfacing: (Optional) Install one of the approved surfacing products listed in Table 4 to obtain desired coating or required fire classification. Maximum Design Pressure: -97.5 psf; With SA Base Sheet or SA Base Sheet FR (See General limitation #7.) -112.5 psf; With all other base sheet options (See General limitation #7.) NOA No.: 19-0508.04 Expiration Date: 10/11/22 Approval Date: 08/08/19 Page 29 of 29 WOOD DECK SYSTEM LIMITATIONS: 1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet. GENERAL LIMITATIONS: 1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire ratings of this product. 2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the top layer 3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size shall be 4' x 4' maximum. 4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of either system shall be at a minimum rate of 12 lbs./sq. Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf. 5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below 275 lbf. insulation attachment shall not be acceptable. 6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum fastener resistance value in conjunction with the maximum design value listed within a specific system. Should the fastener resistance be less than that required, as determined by the Building Official, a revised fastener spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing Application Standard RAS 117. 7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this NOA, General Limitation #9 will not be applicable.) 8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to Roofing Application Standard RAS 111 and applicable wind load requirements. 9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field, perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically referred within this NOA, General Limitation #7 will not be applicable.) 10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. END OF THIS ACCEPTANCE