HomeMy WebLinkAboutMule-Hide SA copy
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 1 of 29
MIAMI-DADE COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION T (786) 315-2590 F (786) 315-2599
NOTICE OF ACCEPTANCE (NOA) www.miamidade.gov/economy
Mule-Hide Products Co., Inc.
1195 Prince Hall Drive
Beloit, WI 53511
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami-Dade County RER - Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami-Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami-Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Mule-Hide Self-Adhered Roof System over Wood Decks
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami-Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #17-0824.11 and consists of pages 1 through 29.
The submitted documentation was reviewed by Hamley Pacheco, P.E.
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 2 of 29
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub-Category: Modified Bitumen
Materials SBS/APP/TPO
Deck Type: Wood
Maximum Design Pressure -112.5 psf
TRADE NAMES OF PRODUCTS MANUFACTURED OR LABELED BY APPLICANT:
TABLE 1
Product
Dimensions
Test
Specification
Product
Description
G2 Base Sheet 108’ x 36” ASTM D 4601,
Type II
Asphalt-coated fiberglass reinforced base sheet
Nail Base 65’ 2” x 3’ 3-3/8” ASTM D 6163,
Type I
SBS modified asphalt coated fiberglass reinforced base
sheet.
SA Base Sheet 66’ 8” x 3’ 3-3/8” ASTM D 6163,
Type I
Self-adhered, fiberglass reinforced, SBS modified
bitumen membrane with a self-adhering back face and
a smooth top surface.
SA Base Sheet FR 66’ 8” x 3’ 3-3/8” ASTM D 6163,
Type I
Self-adhered, fire-rated, fiberglass reinforced, SBS
modified bitumen membrane with a self-adhering back
face and a smooth top surface.
Nail Base P 65’ 8” x 3’ 3-3/8” ASTM D 6164,
Type I
SBS modified asphalt coated polyester reinforced base
sheet.
SA-SBS Cap Sheet 32’ 10” x 3’ 3-3/8” ASTM D 6164,
Type I
Self-adhered, fiberglass reinforced, SBS modified
bitumen membrane with a self-adhering back face and
a granule top surface.
SA-SBS Cap Sheet FR 32’ 10” x 3’ 3-3/8” ASTM D 6164,
Type I
Self-adhered, fire-rated, polyester reinforced, SBS
modified bitumen membrane with a self-adhering back
face and a granule top surface.
SA-SBS KoolCap® 32’ 10” x 3’ 3-3/8” ASTM D 6164,
Type I
Self-adhered, fiberglass reinforced, SBS modified
bitumen membrane with a self-adhering back face and
a granule top surface.
SA-SBS KoolCap®
FR
32’ 10” x 3’ 3-3/8” ASTM D 6164,
Type I
Self-adhered, fire-rated, fiberglass reinforced, SBS
modified bitumen membrane with a self-adhering back
face and a granule top surface.
APP Torch S 32’ 10” x 3’ 3-3/8” ASTM D 6222 Torch applied, polyester reinforced, APP modified
bitumen membrane with a burn off polyethylene back
face and a smooth or sanded top surface.
SA-APP Cap Sheet 32’ 10” x 3’ 3-3/8” ASTM D 6222,
Type I
Self-adhered, polyester reinforced, APP modified
bitumen membrane with a self-adhering back face and
a granule top surface.
SA-APP Cap Sheet FR 32’ 10” x 3’ 3-3/8” ASTM D 6222,
Type I
Self-adhered, fire-rated, polyester reinforced, APP
modified bitumen membrane with a self-adhering back
face and a granule top surface.
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 3 of 29
APPROVED INSULATIONS:
TABLE 2
Product Name Product Description Manufacturer
(With Current NOA)
Mule-Hide Poly ISO 1 Polyisocyanurate foam insulation Polyglass USA, Inc.
Poly ISO 2 Polyisocyanurate foam insulation Polyglass USA, Inc.
ACFoam-II Polyisocyanurate foam insulation Atlas Roofing Corp
ACFoam-III Polyisocyanurate foam insulation Atlas Roofing Corp
Structodek High Density Fiberboard Roof
Insulation
Wood fiber insulation board Blue Ridge Fiberboard, Inc.
DensDeck, DensDeck Prime Gypsum insulation board Georgia-Pacific Gypsum LLC
H-Shield Polyisocyanurate foam insulation Hunter Panels, LLC
H-Shield CG Polyisocyanurate/perlite composite insulation Hunter Panels, LLC
ENRGY-3 Polyisocyanurate foam insulation Johns Manville Corp.
Fesco Board Expanded mineral fiber Johns Manville Corp.
Multi-Max FA-3 Polyisocyanurate foam insulation Rmax Operating, LLC.
SECUROCK Gypsum-Fiber Roof Board Fiber reinforced coverboard United States Gypsum
Corporation
APPROVED FASTENERS:
TABLE 3
Fastener
Number
Product
Name
Product
Description
Dimensions
Manufacturer
(With Current NOA)
1. Dekfast DF-#12-PH3 Insulation fastener for wood, steel
and concrete decks
SFS Group USA, Inc.
2. Dekfast DF-#14-PH3 Insulation fastener for wood, steel
and concrete decks
Various SFS Group USA, Inc.
3. Dekfast DF-#15-PH3 Insulation fastener for wood, steel
and concrete decks
Various SFS Group USA, Inc.
4. Dekfast PLT-H-2-7/8 Galvalume hex stress plate. 2 7/8" x
3 ¼”
SFS Group USA, Inc.
5. #14 Roofgrip Insulation and membrane fastener Various OMG, Inc.
6. Flat Bottom Metal Plate A2-SS aluminized steel plate 3" square OMG, Inc.
7. Mule-Hide HDP Fastener Insulation fastener for steel and
wood decks
Mule-Hide Products
Co., Inc.
8. Mule-Hide 3” Metal Insulation
Plate
Round Galvalume AZ50 steel plate 3.23 round
3" round
Mule-Hide Products
Co., Inc.
9. #12 Standard Roofgrip Insulation fastener for wood, steel
and concrete decks
Various OMG, Inc.
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 4 of 29
APPROVED FASTENERS:
TABLE 3
Fastener
Number
Product
Name
Product
Description
Dimensions
Manufacturer
(With Current NOA)
10. OMG 3 in. Ribbed Galvalume
Plate (Flat)
Galvalume stress plate. 3” round OMG, Inc.
11. OMG 3" Galvalume Steel Plate Galvalume stress plate. 3” round OMG, Inc.
12. Dekfast PLT-R-3 Galvalume stress plate. 3” round SFS Group USA, Inc.
13. Millennium One-Step
Foamable Adhesive
A two component, low rise,
polyurethane foam adhesive
H.B. Fuller Company
14. Millennium One Step Green
Foamable Insulation Adhesive
A two component, low rise,
polyurethane foam adhesive
H.B. Fuller Company
15. Millennium PG-1 Pump Grade
Adhesive
A two component, low rise,
polyurethane foam adhesive
H.B. Fuller Company
16. PG 100 A penetrating solution of solvent
and a blend of selected asphalts used
to promote adhesion.
1, 3, 5, 50, 55
gal, tube or 17
oz. spray can
Polyglass USA, Inc.
17. PG 350 A fibered rubberized adhesive
designed for use with modified
bitumen membranes.
1, 3, 5, 50, 55
gal. or tube
Polyglass USA, Inc.
18. PG 400 A thick, fibered, rubberized flashing
cement for use in dry or damp
conditions.
1, 3, 5, 50, 55
gal. or tube
Polyglass USA, Inc.
19. PG 425 A thick, fibered, rubberized flashing
cement for use in dry or damp
conditions.
1, 3, 5, 50, 55
gal. or tube
Polyglass USA, Inc.
20. PG 450 A thick, fibered, rubberized flashing
cement.
1, 3, 5, 50, 55
gal. or tube
Polyglass USA, Inc.
21. PG 500 A thick, fibered, rubberized flashing
cement for use with modified
bitumen membranes.
1, 3, 5, 50, 55
gal. or tube
Polyglass USA, Inc.
22. POLYPLUS 35 A fibered rubberized adhesive
designed for use with modified
bitumen membranes.
1, 3, 5, 50, 55
gal. or tube
Polyglass USA, Inc.
23. POLYPLUS 45 A thick, fibered, rubberized flashing
cement.
1, 3, 5, 50, 55
gal. or tube
Polyglass USA, Inc.
24. POLYPLUS 50 A thick, fibered, rubberized flashing
cement for use with modified
bitumen membranes.
1, 3, 5, 50, 55
gal. or tube
Polyglass USA, Inc.
25. XtraFlex 10 A penetrating solution of solvent
and a blend of selected asphalts used
to promote adhesion.
1, 3, 5, 50, 55
gal, tube or 17
oz. spray can
Polyglass USA, Inc.
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 5 of 29
APPROVED FASTENERS:
TABLE 3
Fastener
Number
Product
Name
Product
Description
Dimensions
Manufacturer
(With Current NOA)
26. XtraFlex 35 A fibered rubberized adhesive
designed for use with modified
bitumen membranes.
1, 3, 5, 50, 55
gal. or tube
Polyglass USA, Inc.
27. XtraFlex 50 Premium Modified
Wet/Dry Cement
A thick, fibered, rubberized flashing
cement for use with modified
bitumen membranes.
1, 3, 5, 50, 55
gal. or tube
Polyglass USA, Inc.
28. WB-3000 A low-VOC, water-based acrylic
primer to enhance adhesion of self-
adhered membranes.
5 gallon pail Polyglass USA, Inc.
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 6 of 29
APPROVED SURFACING:
TABLE 4
Chosen components must be applied according to manufacturer’s application instructions.
Number Product
Name
Product
Description
Application
Rate
Specification Manufacturer
1. Gravel To be installed in a flood coat
of approved asphalt at 60 lbs/sq
400 lbs/sq N/A Generic
2. v Slag To be installed in a flood coat
of approved asphalt at 60 lbs/sq
300 lbs/sq N/A Generic
3. KM Acryl 15 A premium white or tinted
elastomeric acrylic based roof
coating (water-based). A
polyester fabric may be used
for reinforcement with this
coating.
1-1½ gal/sq ASTM D6083 Polyglass USA,
Inc.
4. KM Acryl 15 QS A premium white or tinted
quick setting, elastomeric
acrylic based roof coating
(water-based). A polyester
fabric may be used for
reinforcement with this coating.
1-1½ gal/sq ASTM D6083 Polyglass USA,
Inc.
5. KM Acryl 25 A premium white or tinted
elastomeric acrylic based roof
coating (water-based). A
polyester fabric may be used
for reinforcement with this
coating.
1-1½ gal/sq ASTM D6083 Polyglass USA,
Inc.
6. KM Acryl 25 QS A premium white or tinted
quick setting, elastomeric
acrylic based roof coating
(water-based). A polyester
fabric may be used for
reinforcement with this coating.
1-1½ gal/sq ASTM D6083 Polyglass USA,
Inc.
7. KM-PS #220 A single component, solvent,
white or tinted, silicone
coating.
1.25 gal/sq ASTM D6694 Polyglass USA,
Inc.
8. KM-PS #250 A premium grade high solids,
white or tinted, single
component, moisture cure,
fluid applied silicone coating
1.25 gal/sq ASTM D6694 Polyglass USA,
Inc.
9. PG 300 An asphalt cutback fibered roof
coating. May be applied by
brush or spray equipment to
rejuvenate aged BUR
1½-2 gal/sq ASTM D4479 Polyglass USA,
Inc.
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 7 of 29
APPROVED SURFACING:
TABLE 4
Chosen components must be applied according to manufacturer’s application instructions.
Number Product
Name
Product
Description
Application
Rate
Specification Manufacturer
10. PG 600 Non-fibered aluminum roof
coating.
½-1 gal/sq ASTM D2824
Type I
Polyglass USA,
Inc.
11. PG 650 Fibered aluminum roof coating. 1½-2 gal/sq ASTM D2824
Type III
Polyglass USA,
Inc.
12. PG 700 A premium white or tinted
elastomeric acrylic based roof
coating (water-based). A
polyester fabric may be used
for reinforcement with this
coating.
1-1½ gal/sq ASTM D6083 Polyglass USA,
Inc.
13. PG 700 QS A premium white or tinted
quick setting, elastomeric
acrylic based roof coating
(water-based). A polyester
fabric may be used for
reinforcement with this coating.
1-1½ gal/sq ASTM D6083 Polyglass USA,
Inc.
14. PG 800 An asphalt based, non-fibered
clay emulsion
3 gal/sq in two
coats
ASTM D1227 Polyglass USA,
Inc.
15. PolyBrite 70 A premium white or tinted
elastomeric acrylic based roof
coating (water-based). A
polyester fabric may be used
for reinforcement with this
coating.
1-1½ gal/sq ASTM D6083 Polyglass USA,
Inc.
16. PolyBrite 70 QS A premium white or tinted
quick setting, elastomeric
acrylic based roof coating
(water-based). A polyester
fabric may be used for
reinforcement with this coating.
1-1½ gal/sq ASTM D6083 Polyglass USA,
Inc.
17. PolyBrite 90 A premium grade high solids,
white or tinted, single
component, moisture cure,
fluid applied silicone coating
1.25 gal/sq ASTM D6694 Polyglass USA,
Inc.
18. PolyBrite 95 A single component, white or
tinted, solvent, moisture cure
silicone coating.
1.25 gal/sq ASTM D6694 Polyglass USA,
Inc.
19. POLYPLUS 60 Non-fibered aluminum roof
coating.
½-1 gal/sq ASTM D2824
Type I
Polyglass USA,
Inc.
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 8 of 29
APPROVED SURFACING:
TABLE 4
Chosen components must be applied according to manufacturer’s application instructions.
Number Product
Name
Product
Description
Application
Rate
Specification Manufacturer
20. POLYPLUS 65 Fibered aluminum roof coating. 1½-2 gal/sq ASTM D2824
Type III
Polyglass USA,
Inc.
21. XtraFlex 60 Aluminum
Roof Coating
Non-fibered aluminum roof
coating.
½-1 gal/sq ASTM D2824
Type I
Polyglass USA,
Inc.
22. XtraFlex 65 Aluminum
Roof Coating Fibered
Fibered aluminum roof coating. 1½-2 gal/sq ASTM D2824
Type III
Polyglass USA,
Inc.
23. XtraFlex 70 Premium
Acrylic FR Roof
Coating
A premium white or tinted
elastomeric acrylic based roof
coating (water-based). A
polyester fabric may be used
for reinforcement with this
coating.
1-1½ gal/sq ASTM D6083 Polyglass USA,
Inc.
24. XtraFlex 80 Emulsion
Roof Coating
An asphalt based, non-fibered
clay emulsion
3 gal/sq in two
coats
ASTM D1227 Polyglass USA,
Inc.
25. XtraFlex 30
Bituminous Roof
Coating Fibered
An asphalt cutback fibered roof
coating. May be applied by
brush or spray equipment to
rejuvenate aged BUR
1½-2 gal/sq ASTM D4479 Polyglass USA,
Inc.
26. XtraFlex SRC 8000 A single component, white or
tinted, solvent, moisture cure
silicone coating.
1.25 gal/sq ASTM D6694 Polyglass USA,
Inc.
27. XtraFlex SRC 9600 A premium grade high solids,
white or tinted, single
component, moisture cure,
fluid applied silicone coating
1.25 gal/sq ASTM D6694 Polyglass USA,
Inc.
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 9 of 29
EVIDENCE SUBMITTED:
Test Agency Test Name/Report Report No.
Date
Factory Mutual Research 4470 2W7A7.AM 08.04.94
Corporation 4450 2D5A9.AM 06.22.99
4470 3000857 01.12.00
4470 3004091 01.12.00
4470 3001334 02.15.00
4470 3014692 08.05.03
4450 3014751 08.27.03
4450 3019317 06.30.04
4470 3024311 11.01.06
4470 3012321 07.29.07
4470 3036182 07.31.09
4470 RR202591 10.22.15
Trinity | ERD TAS 114 11752.09.99-1 02.08.00
TAS 114 11751.05.03 05.30.03
TAS 117(B)-ASTM D903 020841.06.04 06.02.04
TAS 114 02762.03.05 03.30.05
TAS 114 02764.09.05 09.09.05
TAS 114 P1739.01.07 01.23.07
TAS 114 P1734.07.06-R1 02.27.07
TAS 117(B)-ASTM D6862 C8500SC.11.07 11.30.07
TAS 114 & FM 4470 P7860SC.11.07 11.30.07
TAS 114(D) – ASTM D1876 P10070.10.08 10.09.08
TAS 114 (H) P13760.09.09 09.10.09
FM 4470 & TAS 114 P33970.03.11 03.15.11
ASTM D6163 / ASTM D 4601 P33960.03.11 03.15.11
ASTM D6163 P37590.03.13-2-R1 02.05.13
ASTM D6164 P37590.03.13-3A 03.06.13
TAS 114 P1738.02.07-R2 04.29.13
TAS 114 & TAS 117 (B) 11757.04.01-1-R1 04.30.13
ASTM D6509 P37590.03.13-1-R1 06.26.13
ASTM D6222 P37590.03.13-5-R1 07.01.13
ASTM D6164 P37590.07.13-1 07.02.13
TAS 114 & FM 4474 P41630.08.13 08.06.13
ASTM D4601 / TAS 117 P45940.09.13 09.04.13
ASTM D6222 P37590.09.13 09.12.13
ASTM D4601 / TAS 117 P45970.05.14 05.12.14
ASTM D6162 SC5170.05.15 05.08.15
ASTM D6162 SC5170.12.15-1 12.29.15
TAS 114 & FM 4474 PLYG-SC8905.05.16-1 05.17.16
TAS 114 & TAS 117 (B) 11757.12.00-1-R2 04.05.17
PRI Construction Materials ASTM D6222 PUSA-061-02-02 01.28.08
Technologies ASTM D6163 PUSA-064-02-02 02.27.08
ASTM D6222 PUSA-062-02-02 12.04.08
ASTM D6694 PUSA-134-02-01 05.16.14
ASTM D6694 PUSA-135-02-01 05.16.14
TAS 117(B) PUSA-202-02-01 05.08.17
FM 4470 & TAS 114 PUSA-202-02-02 05.23.17
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 10 of 29
APPROVED ASSEMBLIES:
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c..
System Type A(1): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
Anchor Sheet: One ply of Nail Base, APP Torch S* or G2 Base Sheet, fastened to the deck as described
below:
*with OMG fasteners and Flat Bottom Metal Plates.
Fastening #1: Attach base sheet using 11 ga. annular ring shank and 1-5/8” diameter tin caps spaced 8” o.c. in
a 4” lap and 8” o.c. in three equally spaced staggered rows in the center of the sheet.
Fastening #2: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates, Dekfast
DF-#14-PH3 with Dekfast PLT-H-2-7/8 plates or Mule-Hide HDP Fasteners with Mule-Hide
3” Metal Insulation Plates, spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced
staggered rows in the center of the sheet.
One or more of the following
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Poly ISO 2, Mule-Hide Poly ISO 1, ACFoam-II, ACFoam-III, H-Shield, Multi-Max FA-3, ENRGY-3
Minimum 1.5” thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation
attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of ap proved
top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top
layer placed with the polyisocyanurate side facing down.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
DensDeck, DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board
Minimum ¼” thick N/A N/A
Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the EVT range and
at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer
insulation installed as the final membrane substrate. Composite insulation panels may be used as a top layer placed
with the polyisocyanurate side facing down.
Primer:
(Optional)
Apply WB-3000 at 1 gal. per 300 sq. ft.
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered.
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 11 of 29
Ply Sheet:
(Optional)
One or more plies of SA Base Sheet, SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-52.5 psf; (See general limitation #7.)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 12 of 29
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c .
System Type A(2): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
Anchor Sheet: One ply of Nail Base, Nail Base P, APP Torch S, G2 Base Sheet, fastened to the deck as
described below:
Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12”
o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet.
One or more of the following
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Poly ISO 2, Mule-Hide Poly ISO 1, ACFoam-II, ACFoam-III, H-Shield, Multi-Max FA-3, ENRGY-3
Minimum 1” thick N/A N/A
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
DensDeck, DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board
Minimum ¼” thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation
attachment. Insulation listed as base layer only shall be use d only as base layers with a second layer of approved
top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top
layer placed with the polyisocyanurate side facing down.
Primer:
(Optional)
Apply WB-3000 at 1 gal. per 300 sq. ft.
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered.
Ply Sheet:
(Optional)
One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-60 psf; (See general limitation #7.)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 13 of 29
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c.
or #8 wood screws at 6” o.c .
System Type A(3): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
Anchor Sheet: One ply of G2 Base Sheet fastened to the deck as described below:
Fastening: Attach base sheet using 11 ga. Annular ring shank and 1-5/8” diameter tin caps spaced 8” o.c.
in a 4” lap and 8” o.c. in three equally spaced staggered rows in the center of the sheet.
One of more of the following:
Base Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Poly ISO 2, Mule-Hide Poly ISO 1, ACFoam-II, ACFoam-III, H-Shield, Multi-Max FA-3, ENRGY-3
Minimum 1” thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet in full mopping of approved hot asphalt within the EVT
range and at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation
attachment. Insulation listed as base layer only shall be used only as base layers wit h a second layer of approved
top layer insulation installed as the final membrane substrate. Composite insulation panels may be used as a top
layer placed with the polyisocyanurate side facing down.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Dens Deck, Dens Deck Prime, SECUROCK Gypsum-Fiber Roof Board
Minimum ¼” thick N/A N/A
Note: Apply top layer of insulation in a full mopping of any approved mopping asphalt within the EVT range and
at a rate of 20-40 lbs/100 ft2. Please refer to Roofing Application Standard RAS 117 for insulation attachment.
Insulation listed as Base Layer only shall be used only as base layers with a second layer of approved top layer
insulation installed as the final membrane substrate. Composit e insulation panels may be used as a top layer
placed with the polyisocyanurate side facing down.
Primer:
(Optional)
Apply WB-3000 at 1 gal. per 300 sq. ft.
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered.
Ply Sheet:
(Optional)
One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-52.5 psf; (See general limitation #7.)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 14 of 29
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank fastened at 24” spans with #8 wood screws at 6” o.c.
System Type A(4): All insulation layers are adhered to a mechanically attached anchor sheet. Membrane is
subsequently adhered to insulation.
All General and System Limitations apply.
Anchor Sheet: One ply of Nail Base or Nail Base P, fastened as below:
Fastening: 12 ga. Annular ring shank nails and 1-5/8” tin-caps attached 6” o.c. in 4” lap and 6” o.c. in four
equally spaced staggered rows.
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ACFoam-II, Poly ISO 2, ACFoam-III, H-Shield, Mule-Hide Poly ISO 1, H-Shield CG, Multi-Max FA-3, ENRGY
3
Minimum 1” thick N/A N/A
Note: All insulation shall be adhered to the anchor sheet with Millennium One-Step Foamable Adhesive,
Millennium One Step Green Foamable Insulation Adhesive or Millennium PG-1 Pump Grade Adhesive applied
over rows of tin-caps in continuous rows 7” o.c. Please refer to Roofing Application Standard RAS 117 for
insulation attachment. Insulation listed as base layer only shall be used only as base layers with a second layer of
approved top layer insulation installed as the final membrane substrate. Composite insulation panels may be
used as a top layer placed with the polyisocyanurate side facing down.
Primer:
(Optional)
Apply WB-3000 at 1 gal. per 300 sq. ft.
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered.
Ply Sheet:
(Optional)
One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-60 psf; (See general limitation #7.)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 15 of 29
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: Min. 19/32" plywood (15/32" for re-roof) or wood plank, fastened at 24” spans with 8d common
nails at 6” o.c.
System Type C(1): All layers of insulation are mechanically attached to roof deck. Membranes subsequently
adhered to insulation.
All General and System Limitations apply.
One or more of the following
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Any approved Polyisocyanurate listed in Table 2
Minimum 1.0” thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased
maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulati on
attachment.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
SECUROCK Gypsum-Fiber Roof Board
Minimum ¼” thick 2 with 4 or 12; 5 with 6, 10
or 11; 7 with 8
1:2 ft²
DensDeck Prime
Minimum ¼” thick 2 with 4; 5 with 6 or 11; 7
with 8
1:2 ft²
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Primer:
(Optional)
Apply WB-3000 at 1 gal. per 300 sq. ft.
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered.
Ply Sheet:
(Optional)
One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet FR, SA-APP Cap Sheet FR or SA-SBS KoolCap® FR, self-
adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-45 psf; (See General limitation #7.)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 16 of 29
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails or wood
screws at 4” o.c.
System Type C(2): All layers of insulation are mechanically attached to roof deck. Membranes subsequently
adhered to insulation.
All General and System Limitations apply.
One or more of the following
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Any approved Polyisocyanurate listed in Table 2
Minimum 1.5” thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased
maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Structodek High Density Fiberboard Roof Insulation
Minimum ½” thick 2 with 4 1:1.33 ft²
DensDeck
Minimum ¼” thick 2 with 4 1:1.33 ft²
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Primer:
(Optional)
Apply WB-3000 at 1 gal. per 300 sq. ft. to DensDeck prior to application of self-adhered base
sheets.
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered.
Ply Sheet:
(Optional)
One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-67.5 psf; (See General limitation #7.)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 17 of 29
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c.
System Type C(3): All layers of insulation are mechanically attached to roof deck. Membranes subsequently
adhered to insulation.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Any approved Polyisocyanurate listed in Table 2
Minimum 1.5” thick N/A N/A
Note: All layers shall be simultaneously fastened; see top layer below for fasteners and density. Insulation panels
listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be increased
maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for insulation
attachment.
Top Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Structodek High Density Fiberboard Roof Insulation
Minimum ½” thick 2 with 4 1:1.33 ft²
DensDeck
Minimum ¼” thick 2 with 4 1:1.33 ft²
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Primer:
(Optional)
Apply WB-3000 at 1 gal. per 300 sq. ft. to DensDeck prior to application of self-adhered base
sheets.
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered.
Ply Sheet:
(Optional)
One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-67.5 psf; (See General limitation #7.)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 18 of 29
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with wood screws at 6” o.c.
System Type C(4): All layers of insulation are mechanically attached to roof deck. Membranes subsequently
adhered to insulation.
All General and System Limitations apply. Roof accessories not listed in Table 1 of this NOA are not approved
and shall not be installed unless said accessories demonstrate compliance with prescriptive Florida Building Code
requirements and are field fabricated utilizing the approved membranes listed in Table 1.
One or more of the following:
Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
ENRGY 3, H-Shield, Mule-Hide Poly ISO 1, ACFoam-II, Poly ISO 2
Minimum 1.5” thick 2 with 4; 7 with 8 1:1.33 ft²
Note: All layers of insulation shall be mechanically attached using the fastener density listed above. The insulation
panels listed are minimum sizes and dimensions; if larger panels are used, the number of fasteners shall be
increased maintaining the same fastener density. Please refer to Roofing Application Standard RAS 117 for
insulation attachment.
Primer:
(Optional)
Apply WB-3000 at 1 gal. per 300 sq. ft.
Base Sheet: One ply of SA Base Sheet or SA Base Sheet FR, self-adhered.
Ply Sheet:
(Optional)
One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-82.5 psf; (See General limitation #7.)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 19 of 29
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c.
System Type D(1): All insulation is loosed laid with preliminary attachment to deck. Base sheet is subsequently
mechanically fastened through insulation to the roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Any approved Polyisocyanurate listed in Table 2
Minimum 1” thick N/A N/A
Top Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Fesco Board
Minimum ¾” thick N/A N/A
Structodek High Density Fiberboard Roof Insulation
Minimum ½” thick N/A N/A
DensDeck, DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board
Minimum ¼” thick N/A N/A
Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a
minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,
and four fasteners for any insulation board having no dimension greater than 8 ft.
Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below:
Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates, Dekfast
DF-#14-PH3 with Dekfast PLT-H-2-7/8 plates, or Mule-Hide HDP Fasteners with Mule-Hide
3” Metal Insulation Plates, spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced
staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-52.5 psf; (See General limitation #7.)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 20 of 29
Membrane Type: SBS/APP
Deck Type 1I: Wood, Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c.
System Type D(2): All insulation is loosed laid with preliminary attachment to deck. Base sheet is subsequently
mechanically fastened through insulation to the roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
One or more layers of the following:
Base Insulation Layer Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Any approved Polyisocyanurate listed in Table 2
Minimum 1” thick N/A N/A
Top Insulation Layer (Optional) Insulation Fasteners
(Table 3)
Fastener
Density/ft2
Fesco Board
Minimum ¾” thick N/A N/A
Structodek High Density Fiberboard Roof Insulation
Minimum ½” thick N/A N/A
DensDeck, DensDeck Prime, SECUROCK Gypsum-Fiber Roof Board
Minimum ¼” thick N/A N/A
Note: All insulation shall have preliminary attachment, prior to the installation of the roofing membrane at a
minimum application rate of two fasteners per board for insulation boards having no dimension greater than 4 ft.,
and four fasteners for any insulation board having no dimension greater than 8 ft.
Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below:
Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12”
o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, , self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-60 psf; (See General limitation #7.)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 21 of 29
Membrane Type: SBS/APP
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c.
or #8 wood screws at 6” o.c.
System Type E(1): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below:
Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8” diameter tin caps spaced 8”
o.c. in a 4” lap and 8” o.c. in three equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-52.5 psf; (See General limitation #7.).
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 22 of 29
Membrane Type: SBS/APP
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d ring shank nails at 6” o.c.
at edges and intermediate supports.
System Type E(2): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base, fastened to the deck as described below:
Fastening: Attach base sheet using 11 ga. annular grooved shank and 1” diameter caps spaced 6” o.c. in a
3” lap and 6” o.c. in four equally spaced staggered center rows.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet
FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-52.5 psf; (See General Limitation #7)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 23 of 29
Membrane Type: SBS/APP
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c.
or #8 wood screws at 6” o.c
System Type E(3): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below:
Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates spaced 12”
o.c. in a 4” lap and 12” o.c. in two equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet, SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet
FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-52.5 psf; (See General Limitation #7)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 24 of 29
Membrane Type: SBS/APP
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with 8d common nails at 4” o.c.
or #8 wood screws at 6” o.c .
System Type E(4): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below:
Fastening: Attach base sheet using 11 ga. annular ring shank nails and 1-5/8” diameter tin caps spaced 8”
o.c. in a 4” lap and 8” o.c. in three equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet
FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-52.5 psf; (See General Limitation #7)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 25 of 29
Membrane
Type:
SBS/APP
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened at 24” spans with #8 wood screws at 6” o.c.
System Type E(5): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base, fastened to the deck as described below:
Fastening: Attach base sheet using OMG #14 Roofgrip fasteners and Flat Bottom Metal Plates, Dekfast
DF-#14-PH3 with Dekfast PLT-H-2-7/8, or Mule-Hide HDP Fasteners with Mule-Hide 3”
Metal Insulation Plates, spaced 12” o.c. in a 4” lap and 12” o.c. in two equally spaced
staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap
Sheet FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-60 psf; (See General limitation #7.).
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 26 of 29
Membrane Type: SBS/APP
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24” o.c. and to blocking
members spaced 48” o.c. with TruFast TP #10x2-7/8” screws spaced 6” o.c.
System Type E(6): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below:
Fastening: Attach base sheet using 12 ga. annular ring shank nails and 1-5/8” diameter tin caps spaced 4”
o.c. in a 4” lap and 4” o.c. in four equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane:
One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet
FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-97.5 psf; (See General Limitation #7)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 27 of 29
Membrane Type: SBS/APP
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24” o.c. and to blocking
members spaced 48” o.c. with #10x3” wood screws spaced 6” o.c.
System Type E(7): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below:
Fastening: Attach base sheet using 12 ga. ring shank nails and tin caps spaced 4” o.c. in a 4” lap and 4” o.c.
in four equally spaced staggered rows in the center of the sheet.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet
FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-97.5 psf; With SA Base Sheet or SA Base Sheet FR (See General limitation #7.)
-112.5 psf; With all other base sheet options (See General limitation #7.)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 28 of 29
Membrane Type: SBS/APP
Deck Type 1: Wood, Non-Insulated
Deck Description: 19/32" or greater plywood or wood plank, fastened to supports spaced 24” o.c. with #8x3” wood
screws spaced 6” o.c.
System Type E(8): Base sheet is mechanically attached to roof deck. Membranes subsequently adhered.
All General and System Limitations apply.
Base Sheet: One ply of Nail Base or Nail Base P, fastened to the deck as described below:
Fastening: Attach base sheet using 12 ga. annular ring shanked nails and 1-5/8” tin-caps 6” o.c. in 4” lap
and 6” o.c. in four equally spaced staggered rows. Tin-caps are primed with PG 100 or
XtraFlex 10.
Ply Sheet: One or more plies of SA Base Sheet or SA Base Sheet FR, self-adhered.
Membrane: One ply of SA-SBS Cap Sheet, SA-SBS Cap Sheet FR, SA-APP Cap Sheet, SA-APP Cap Sheet
FR, SA-SBS KoolCap® or SA-SBS KoolCap® FR, self-adhered.
Surfacing:
(Optional)
Install one of the approved surfacing products listed in Table 4 to obtain desired coating or
required fire classification.
Maximum Design
Pressure:
-97.5 psf; With SA Base Sheet or SA Base Sheet FR (See General limitation #7.)
-112.5 psf; With all other base sheet options (See General limitation #7.)
NOA No.: 19-0508.04
Expiration Date: 10/11/22
Approval Date: 08/08/19
Page 29 of 29
WOOD DECK SYSTEM LIMITATIONS:
1. A slip sheet is required with Ply 4 and Ply 6 when used as a mechanically fastened base or anchor sheet.
GENERAL LIMITATIONS:
1. Fire classification is not part of this acceptance; refer to a current Approved Roofing Materials Directory for fire
ratings of this product.
2. Insulation may be installed in multiple layers. The first layer shall be attached in compliance with Product
Control Approval guidelines. All other layers shall be adhered in a full mopping of approved asphalt applied
within the EVT range and at a rate of 20-40 lbs./sq., or mechanically attached using the fastening pattern of the
top layer
3. All standard panel sizes are acceptable for mechanical attachment. When applied in approved asphalt, panel size
shall be 4' x 4' maximum.
4. An overlay and/or recovery board insulation panel is required on all applications over closed cell foam insulations
when the base sheet is fully mopped. If no recovery board is used the base sheet shall be applied using spot mopping
with approved asphalt, 12" diameter circles, 24" o.c.; or strip mopped 8" ribbons in three rows, one at each side lap
and one down the center of the sheet allowing a continuous area of ventilation. Encircling of the strips is not
acceptable. A 6" break shall be placed every 12' in each ribbon to allow cross ventilation. Asphalt application of
either system shall be at a minimum rate of 12 lbs./sq.
Note: Spot attached systems shall be limited to a maximum design pressure of -45 psf.
5. Fastener spacing for insulation attachment is based on a Minimum Characteristic Force (F') value of 275 lbf., as
tested in compliance with Testing Application Standard TAS 105. If the fastener value, as field-tested, are below
275 lbf. insulation attachment shall not be acceptable.
6. Fastener spacing for mechanical attachment of anchor/base sheet or membrane attachment is based on a minimum
fastener resistance value in conjunction with the maximum design value listed within a specific system. Should
the fastener resistance be less than that required, as determined by the Building Official, a revised fastener
spacing, prepared, signed and sealed by a Florida registered Professional Engineer, Registered Architect, or
Registered Roof Consultant may be submitted. Said revised fastener spacing shall utilize the withdrawal
resistance value taken from Testing Application Standards TAS 105 and calculations in compliance with Roofing
Application Standard RAS 117.
7. Perimeter and corner areas shall comply with the enhanced uplift pressure requirements of these areas. Fastener
densities shall be increased for both insulation and base sheet as calculated in compliance with Roofing Application
Standard RAS 117. Calculations prepared, signed and sealed by a Florida registered Professional Engineer,
Registered Architect, or Registered Roof Consultant (When this limitation is specifically referred within this
NOA, General Limitation #9 will not be applicable.)
8. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall conform to
Roofing Application Standard RAS 111 and applicable wind load requirements.
9. The maximum designed pressure limitation listed shall be applicable to all roof pressure zones (i.e. field,
perimeters, and corners). Neither rational analysis, nor extrapolation shall be permitted for enhanced fastening at
enhanced pressure zones (i.e. perimeters, extended corners and corners). (When this limitation is specifically
referred within this NOA, General Limitation #7 will not be applicable.)
10. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61G20-3 of the Florida Administrative Code.
END OF THIS ACCEPTANCE