Loading...
HomeMy WebLinkAboutBUNK #103 SE CELESTIA COURT SHED PLOT PLANLOT 16 LOT 15 Block 45 a a, Block 45 (OCCUPIED) z (OCCUPIED) .)N 75'14'OQ"_ E _-08.53'. 0 at i� 0 A A r*i n 0 W tJs LOT 34 Block 45 (OCCUPIED) O1 Va. n 0 z air �rn oio 8.02' 12.00' a� rn 0 0 0 0 12.00' 8.02' PROPOSED WOODEN SHED 21.2' N COVERED ^' CONC v PORCH '� 10.7' R. ---- % 2 °' C LOT 35 • —` r_' �' 8.1' Block 45 o D - 329 m ONE—STORY RESIDENCE 28.8 r t 9.5, A A 0 0 A r N vrq' � � J � AiLl LOT 14 et Block 45 � (OCCUPIED) `6' WF (0.6'N.0.3'E) T A A ON C c LOT 36 rn Block 45 (VACANT) Ln 0 O LEGEND ® - SANITARY CLEANOUT -OHE- = OVERHEAD UTILITY LINES 0 = WOOD POWER POLE CL = CENTERLINE RIGHT OF WAY EP = EDGE OF PAVEMENT FIRC = FOUND 5/8" IRON ROD & CAP (NO I.D.) FIR = FOUND 5/8" IRON ROD & CAP tNO I.D.) FIP - FOUND 2 IRON PIPE & CAP (NO I.D.) CLF = CHAIN LINK FENCE WF - WOOD FENCE CONC = CONCRETE • = WATER METER A/C - AIR CONDITIONER PAD D = DELTA ANGLE L = ARC LENTH R = RADIUS �.15• 57fi3 8 N 75' 14'00" E 9 51.33' •FIR / .00 CONC CONC 2' CONC CONC .� WALK CURBING 10 APRON CONC � APRON ;0 APRON �0 EP %D=15'57' 38 ii R-55.00' 1 CL S 7514'00" W 51.33' 499.68' h ems" �15'32 CUR ATUREF Basis of Bearings �I _ C VATUPOINT of Q� CURVATURE 1' 2' CONC Qi rbrb- CURBING EP i SE Celestia Court (60' Right—of—way) 20' Pavement Z6 NOVEMBER 30, 2020 Dote of Signature WILLIAM B. SENNETT Professional Surveyor & Mapper norido Certificate No. 6353 LB No. 7608 M Saba a gA mv Ss tCA 'fl+ ftna a SI T.,:E y s N rtK"a se ►earn a »a W Vicinity Map (Hot To Scale) LEGAL DESCRIPTION: LOTS 35, BLOCK 45. RIVER PARK —UNIT 5, according to the mop or plat thereof, as recorded in Plot Book 34, at Page 28 ("A" through "N"), of the Public Records of St. Lucie County, Florida. Subject to all pertinent matters of record. LOT AREA: 10.617 Sq. Ft.: 0.24 Acres* STREET ADDRESS: 103 SE Celestia Court, Port St. Lucie. Florida 34983. SURVEYORS' NOTES: 1. Bearings shown hereon are based on the centerline of SE Celestia Court as platted and bears S 75'14'00" W. 2. Written dimensions take precedence over scaled dimensions and distances are not to be scaled for construction and/or design purposes. 3. All distances and bearings are as field measured and are coincident with "PLAT" and description data unless otherwise noted. 4. This drawing is not valid without the signature and original raised seal of a Florida licensed Surveyor & Mapper. 5. This survey is based upon a description furnished by the client, there has been no search of the public records done by this office. 6. Property lies in Flood Zone "X' as scaled from the National Flood Insurance Program Rate Map, Community Panel Number 12111CO280 J, with an effective dote of February 16, 2012. 7. This survey is not covered by professional liability insurance. 8. City water & sewer are available in this area. 9. This survey meets the required accuracy as shown in Ch. SJ-17.051 (2) (b) based on its expected use. 10. No underground utilities or improvements were located unless otherwise shown. 11. This plan information to be verified by contractor prior to construction. CERTIFIED TO: JAY BUNK Revised: Add proposed 12'x24' shed to Lot 36, WB, 10-16-15. Revised: Add proposed 12'06' shed/Remove Lot 36, WEI, 11-30-20. Date of Last field work:07/30/201' � Boundary Survey & Site Plan 'k n n e tt Prepared on the order of: Bennett Surveying, Inc. Jay Bunk 107 Augusto Court Field: L,M/BB Job No.: 15-0309 Jupiter, FAdda 33458 tel: 772.336.4933 Drown: LM Date: 08 26 2015 email: bennettsurveyingOyahoo.com Scale: 1 "=20' Sheet: 1 of 1