26ga (min) SNAPMAX over 15/32" (min) plywood
Extreme Metal Fabricators
21'20 SW Poma Dr I Palm City FL 34990
Product Description
Nailstrip, snaplock style panel with a 16" maximum panel width and a
nominal rib height of 1"
Product Material
26ga (min) steel
Corrosion resistant per FBC 1507.4.3 where required
RECEIVED
Fastener
#10 x 1-inch pancake style fastener Jp�� 2011
Compliant with FBC 1506.6 where required. PermittingDcPartme1lt
Substrate/Deck St. Lucie County
15/32" (min) plywood or
3/4" (min) thick wood plank (min S.G. of 0.42)
Evaluated by:
David Eng, PE
Timberlake Cove, LLC
3324 W Univ Ave #206 1 Gainesville FL
FL PE 81377 1 FL CA 33344
www.Ti m be rLa keCove.co m
Underlayment: Comply with local building code or FBC 1507.1.1/1518.2 where required.
Slope: Comply with local building code or FBC 1507.4.2/FBC 1515.2 where required.
Re -Roofing: This panel may be installed over a single layer of existing shingles as permitted
by local building code or FBC 1511/1521, provided the existing roof meets the conditions
required by the applicable code.
Fire Barrier: Comply with FBC 1516.1`and 1516.2 where required.
Maximum Allowable Loads & Installation Requirements:
Method A: #10 x 1" fastener at 6" o.c. along nail strip: 116 PSF
Method B: #10 x 1" fastener at 6" o.c. along nail strip WITH sealant: 176 PSF
For Method B, use continuous bead of Geocel 2320 sealant or similar.
A factor of safety of 2 has been applied.
Fasteners are installed through the metal flange, NOT through the pre -punched slots.
Technical Documentation:
This product has been tested to the TAS 125 / UL 580 standard by Intertek Testing (TST-1527),
report G3443.48-450-44 as referenced in.FL 28059.04-RO.
Compliance Statement:
This product as described has demonstrated compliance with Florida Building Code 2020,
1504.3.2 (non-HVHZ) and 1518.9.1/1523.6.5.2.4 (HVHZ), as required by FL Rule 61G20-3, method ID.
This product as described has been tested and demonstrated compliance with:
• UL580 - Test for Uplift Resistance of Roof Assemblies
• UL 1897 - Uplift test for roof covering systems
• TAS 125 - Standard Requirements for Metal Roofing Systems
• TAS 100 - Wind and Wind -Driven Rain
Design Process:
The load tables in this report provides one prescriptive option for the fastening requirement
for the applicable wind loads for roofs within •the parameters described. For roofs outside of
the listed parameters, design wind loads shall be determined as required by FBC 1609, ASCE 7, or
other design code in force, using allowable stress. These load tables are based on ASCE 7-16.
Use of these tables assumes that the structure is:
• Enclosed and conforms to wind-borne debris provisions and is a regular shaped building
• Is not subject to across -wind loading, vortex shedding, or instability; nor does it have a
site location for which channeling or buffeting warrant consideration
Engineering analysis may be completed by other licensed engineers for project specific
approval by local authorities having jurisdiction.
Certification of Independence:
David Eng, PE and Timberlake Cove, LLC do not have, nor will acquire a financial interest in any company
manufacturing or distributing products under this evaluation. The same entities do not have, nor will
acquire, a financial interest in any other entity involved in the approval process of the product.
Exclusions and Limitations:
Design of deck and roof structure (to include 'attachment of plywood or wood plank) shall be completed by
others. Fire classification and shear diaphragm design are outside the scope of this evaluation. Accelerated
weathering/salt spray is outside the scope of this evaluation.
This report is limited to compliance with structural wind load requirements of FBC 1504.3.2. as required by
Rule 61G20-3. Neither Timberlake Cove nor the manufacturer shall be responsible for any conclusions,
interpretations, or designs made by others based on this evaluation report. This report is limited solely to
documenting compliance with Rule 61G20-3, and makes no express or implied warranty regarding
performance of this product. Installation shall be subject to the .local building code and authority having
jurisdiction; this report shall not be construed to supersede local codes in force.
Instructions:
Select the appropriate load table that applies to the
structure in question.
Determine the design wind speed for the project
location.
Use the attachment method indicated for that
windspeed within each roof zone.
NOTE: ASCE 7-16 and FBC 2020 adopt a 7-zone concept.
For the load tables below, the worst case was taken
for each zone and reported using the standard zones
1-2-3:
Zone 1 includes zones 1 and 1'
Zone 2 includes zones 2e, 2r, and 2n
Zone 3 includes zones 3e and 3r
Combining these zones creates a clear, simple
scheme, at the expense of some design efficiency.
Contact the manufacturer for further information,
or consult a licensed design professional.
METHOD.A
a-
.""C
2
2
3
2 1
2
1
2
I
2 1 2
2
2
� I
a l
2
3
2
3
�a
7�I
1
1
2
2/
I
3 2
I Gnnp
2
real F Rnnr —�
3
''1
L
METHOD B
a: 10%OF LEAST HOIZONTAL DIMENSION OR 04h. WHICHEVER IS SMALLER. BUT NOT
LESS THAN EITHER 4%OF LEAST HORIZONTAL DIMENSION OR 3Fr (0.9hfI.
OR AS DETERMINED BY DESIGN OR OTHER APPLICABLE CODE.
ROOF ZONES FOR GENERIC BUILDING
�� FEMALE LEG SNAPS FEMALE LEG SNAPS
ONTO MALE LEG ONTO MALE LEG
' SEALANT APPLIED TO
BASE OF MALE LEG
#10 FASTENER #10 FASTENER
AT 6" O.C. AT 6" O.C.
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof, or gablelhip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
NR: NOT RATED
CONSULT DESIGN
PROFESSIONAL AS
NECESSARY
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area .
Have either a flat roof, or gable/hip roof with max slope of 12:12
Have a mean Roof Height of 30 feet or less
FL25621.05: 26
a Spa
Max on 15/32" phLwood
FL25621.05: 26
a Sna
Max on 15/32" I ood
Wind 105
110
120
130
140
150
160
170
180 190 200
Wind 105
110
120
130
140
150
160
170 180 190 200
Zone 1:. A
A
A
A
A
A
A
A
A A A
Zone 1: AAA
A
A
A
A
A A; B B
Zone 2: A
A
A
A
A
A
A
A
A A! B
Zone 2: A
A
A
A
A
A
B
B B B
Zone 3: A
A
A
A
A
A
A
A
A! B^ B
Zone 3: A
A
A
A
A
B.
B
B
Use this load table for structures which meet the following criteria:
Are located in Exposure B area
Have either a flat roof less than 7°, hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height of 30 feet or less
FL25621.05: 26aa SnaoMax on 15/32" plvwood
Wind
105
110
120
130
140
150
160
170
180
190
200
Zone 1:
A
A
A
A
A
A
A
A
A
A
A
Zone 2:
A
A
A
A
A
A
A
A
A
A
A
Zone 3:
A
A
A
A
A
A
A
A
A
A
B
Use this load table for structures which meet the following criteria:
Are located in B, C, or D exposure area
Have either a flat roof less than 7°, hip roof with
max slope of 12:12, or gable roof with slope between 4.4:12 & 12:12
Have a mean Roof Height -of 30 feet or less
FL25621.05: 26aa SnaDMax on 15/32" plvwood
Wind
105
110
120
130
140
150
160
170
180 190 200
Zone 1:
A
A
A
A
A
A
A
A
A _A_; B
Zone 2:
A
A
A
A
A
A_
A
B
B B B
Zone 3:
A
A
A
A
A
B
B
B
B_rQ
CBUCK EnQ1neerinQ
Specialty Strucf Urdl Enc;11 IPPf1ng CBUCK, Inc. Certificate of Authorization #8064
Evaluation Report
"MAT 40T"
Roof Underlayment
Manufactured By:
BITEC, Inca
#2 Industrial Park Drive
P.O. Box 497
Morrilton, AR 72110
(800) 535-8597
for
Florida Product Approval
# FL 5215.2 R6
Florida Building Code 7th Edition (2020)
Method: 1- D
Category: Roofing
Sub - Category: Underlayment
RECEIVED
JAN 2.� 70?1
permitting Department
St. Lucie County
Product: "MAT-40T"1'
Description: Self -Adhered
SBS Modified Membrane
This item has been electronically signed and sealed by
James L. Buckner, P.E., on this date using a Digital Signature.
Prepared by: Printed copies of this document are not considered signed
and sealed, and the signature must be verified on any
James L. Buckner, P.E., S.E.C.B. electronic copies.
Florida Professional Engineer # 31242
Florida Evaluation ANE ID: 1916
Project Manager: Diana Galloway
Report No. 20-246-MAT40-ER
(Revises 17-123-MAT40-ER, FL5215.2 R5)
Date: 10 / 01 / 20
Contents:
Evaluation Report Pages 1— 6 2020.10.02 18:48:16-04'00'
CBUCK, Inc. dba CBUCK Engineering
Phone: (561) 491-9927 • Email: cbuck@cbuckinc.net • Website: www.cbuckinc.net
Business: 1374 Community Dr., Jupiter, FL 33458 • Corp/Mailing: 2637 E. Atlantic Blvd, #34069, Pompano Beach, FL 33062
CBUCK Engineering
Speclalty Structural Engineering
Manufacturer: BITEC, Incorporated
#2 Industrial Park Drive
P.O. Box 497
Morrilton, AR 72110
(800) 535-8597
http://www.bi-tec.com
Product Name: "MAT-40'"1'
Product Category: Roofing
Product Sub -Category: Underlayment
FL #: FL 5215.2 R6
Date: 10 / 01 / 20
Report No.: 20-246-MAT40-ER
Page 2 of 6
CBUCK, Inc. Certificate of Authorization ##8064
Compliance Method: State Product Approval Rule 61G20-3.005 (1) (d)
Product Description: Self -adhering membrane composed of SBS polymer modified adhesive applied to the
bottom surface. A split release film treated with silicone is applied to the adhesive
surface. Top surface composed of polyester fabric and contains a 2" selvedge edge.
"MAT-40T""" is typically for use with metal & the roofs.
Product Dimension(s):
Product Material /
Standards:
Roll Size: 64.5 ftz x 3.28 ft'
Thickness: 76 mils minimum (with a production tolerance of ±9.9)
Top Surface:
Bottom Surface
Material Standard
Polyester fabric
SBS Polymer Bitumen
ASTM D 1970
Roof Cover Types: Allowable for use with the following roof cover types. Refer to Limitations &
Conditions of use for additional requirements. Material and application shall be in
compliance with FBC Section 1507.1.1 and in accordance with applicable code sections
and manufacturer's recommendations.
1. Asphalt Shingles
2. Clay & Concrete Tile
3. Metal roof
4. Metal shingles
Support: Type:
Wood Deck
(Design of support system is outside the scope of this evaluation)
Installation: Install the "MAT-40T""" in compliance with applicable code sections of FBC 7th Edition
(2020), this evaluation report and manufacturer's installation instructions subject to
the Limitations and Conditions of Use listed in this Evaluation Report. The installation
method described in this report is in accordance with manufacturer's recommended
installation instructions.
FL #: FL 5215.2 R6
Date: 10 / 01 / 20
meeting Page Report NO•' 3 of 6 MAT40 ER
Speclalty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
Performance Standards: The product described herein has demonstrated compliance with:
• ASTM D 1970-15a— Specification Self -adhering Polymer Modified Bituminous Sheet
Materials Used as Steep Roof Underlayment for Ice Dam Protection
• ASTM D 1623-78/AC152 —Standard Test Method for Tensile and Tensile Adhesion
Properties of Rigid Cellular Plastics
Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the prescribed
standards in ASTM D 1970-15a standard version adopted by the Florida Building Code
7th Edition (2020) for use as evaluated in this report.
Code Compliance: The products described herein have demonstrated compliance with the
performance standards listed above as referenced in the Florida Building Code 7th
Edition (2020).
Evaluation Report Scope: This product has been evaluated in compliance with the building envelope
requirements of the Florida Building Code, as related to the scope section of Florida
Product Approval Rule 61G20-3.001.
Product Limitations and
• Products are evaluated for use with approved roof coverings that are
Conditions of Use:
mechanically fastened through the underlayment and is attached to the
sheathing or rafters. For use with tile roof installation, refer to FRSA/TRI Florida
High Wind Clay and Concrete Roof Tile Installation Manual, Sixth Edition per FBC
1507.3.3 and 1507.3.3.1.
• "MAT-40T""" has been tested and evaluated for use with Polyfoam Products, Inc.
Polypro AH160. Refer to roof system product approval and FRSA/TRI Florida High
Wind Clay and Concrete Roof Tile Installation Manual, Sixth Edition for approved
attachment methods.
• "MAT-40T""" is acceptable for use with any roof covering system which references
"MAT-40""" in the FBC approval. If not listed, an application may be submitted to
the local building jurisdiction for approval based on this evaluation combined with
supporting data for the roof covering and its attachment to support.
General Limitations and
• Scope of "Limitations and Conditions of Use" for this evaluation:
Conditions of Use:
This evaluation report for "Optional Statewide Approval' contains technical
documentation, specifications and installation method(s) which include "Limitations
and Conditions of Use" throughout the report in accordance with Rule 61G20-
3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to
approve products under "Optional Statewide Approval'.
• Option for application outside "Limitations and Conditions of Use"
Rule 61G20-3.005(1)(e).allows engineering analysis for "project specific approval by
the local authorities having jurisdiction in accordance with the alternate methods
and materials authorized in the Code". Any modification of the product as
evaluated in this report and approved by the Florida Building Commission is outside
the scope of this evaluation and will be the responsibility of others.
• This report is a building code product evaluation per FLPE rule (FAC) 61G15-36 to
comply with Florida product approval rule (FAC) 61G20-3. This evaluation report is
part of the Florida Building Commission approval for the listed code related criteria.
This report by James Buckner, P.E. and CBUCK Engineering is not a design
certification of code compliance construction submittal documentation, per FBC
FL M FL 5215.2 R6
Date: 10 / 01 / 20
Page Report No.: 4 of 66 MAT40 ER
C81ICK Engineering
Speclalty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064
section 107, for any individual structure, site specific or permit design.
• Design of support system is outside the scope of this report.
• Fire Classification is outside the scope of Rule 61G20-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the High
Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance
with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a
quality assurance program audited by an approved quality assurance entity through
Keystone Certifications, Inc. (FBC Organization ID# QUA 1824).
Referenced Data: 1. ASTM D 1970-01 Test
By PRI Asphalt Technologies (FBC Organization #TST ID: 1556)
Report #: BIT-004-02-01, Report Date: 07/18/05
2. ASTM D 1623-78 Test (in compliance with ICC-ES AC152)
By Trinity ERD, (FBC Organization #TST ID: 6049)
Report #: P12890.10.09-1, Report Date: 10/30/09
3. Letter from Polyfoam Products, Inc. authorizing use of:
Test Report #1312890.10.09-1, Signed by Riku Ylipelkonen, Dated: 11 / 15 / 10
4. Equivalency of Test Standard. Certification
By James L. Buckner, P.E. @ CBUCK Engineering
5. Quality Assurance
Keystone Certifications, Inc. (FBC Organization ID# QUA 1824)
Bitec, Inc.. Licensee #340 .
6. 'Certification of Independence
By James L. Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
FL M FL 5215.2 R6
Date: 10 / 01 / 20
CBUCK Engineerinq Re,oPage rt No.: 6 Of 6 MAT40-ER
Speclalty Structural Englneerinq ceucK, Inc. Certificate of Authorization u8064
INSTALLATION METHOD
BITEC, Incorporated
„MAT 40TM"
Self -Adhered Roofing Underlayment
ucceening courses'.
e nr
o MAT-40.
U,ndeftyent n
:2 .inEn . sldelaps
wi Mfg
,
�ertdlaps,
` - MAT-40 ,rr
-
, Un�d:e'rlayment..
MAT 44 must ,-
tEil`dowlt by N
MOtal drip.; dd ge,
;apt�©�aG.
..
t "041' drObdge at-calte
. l�cpw6d f8dia.below,
over
ilclp.ade.,.
Typical Installation
t -
tN
SCIS Home Log In I User Registration I Hot Topics I Submit Surcharge Stats & Facts Publications Contact Us BCIS Site Map I Links I Search
Florida
d b r 4u.r.:,.blic Product Approval
User
ProductAoproval Menu > Product or Application Search > Application List > Application Detail
FL # FL1654-R27
T
Application Type Revision
Code Version 2020
Application Status Approved
Comments
Archived C�
Product Manufacturer POLYGLASS USA
Address/Phone/Email 1111 W. Newport Center Drive
Deerfield Beach, FL 33442
(954) 233-1330 Ext242
malpert@polyglass.com
Authorized Signature Maury Alpert
malpert@polyglass.com
Technical Representative TECH REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(866) 802-8017
uspolyglasstechnical@polyglass.com
Quality Assurance Representative QA REP
Address/Phone/Email 1111 West Newport Center Drive
Deerfield Beach, FL 33442
(888) 410-1375
uspolyglasstechnical@polyglass.com
Category Roofing
Subcategory Modified Bitumen Roof System
Compliance Method
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional
Engineer
C:) Evaluation Report - Hardcopy Received
Florida Engineer or Architect Name who developed the Evaluation
Robert Nieminen
Report
Florida License
PE-59166
Quality Assurance Entity
UL LLC
Quality Assurance Contract Expiration Date
11/07/2022
Validated By
John W. Knezevich, PE
E7 Validation Checklist - Hardcopy Received
Certificate of Independence
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL1654 R27 COI 2020 01 COI NIEMINEN.pdf
Standard
Year
ASTM D4601
2012
ASTM D4897
2009
ASTM D6162
2015
ASTM D6163
2015
ASTM D6164
2011
ASTM D6222
2011
ASTM D6509
2015
ASTM G155
2013
FM 4470
2016
FM 4474
2011
UL 1897
2012
Product Approval Method Method 1 Option D
Date Submitted 10/02/2020
Date Validated 10/04/2020
Date Pending FBC Approval 10/12/2020
Date Approved 12/15/2020
Summary of Products
r
FL #
Model, Number or Name
Description
1654.1
Polyglass Modified Bitumen Roof Systems
SBS and APP modified bitumen roof systems
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1654 R27 II 2020 09 30 FINAL Al ER PG MODBIT FL1654-R27.odf
Verified By: Robert Nieminen PE-59166
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-622.5
Evaluation Reports
Other: 1.) The design pressure in this application relates to one particular
FL1654 R27 AE 2020 09 30 FINAL ER PG MODBIT FL1654-R27.Ddf
Created by Independent Third Party: Yes
assembly over concrete deck. Refer to the ER Appendix for other systems and
deck types. 2.) Refer to ER, Section 5 for other Limits of Use. 3.) Refer to
FL16717 for HVHZ jurisdictions.
Back Next
Contact Us :: 2601 Blair Stone Road, Tallahassee Fl. 32399 Phone: 850-487-1824
The State of Florida is an AA/EEO employer. Cho y=ght 2007-2013 State of Florida :: Privacy Statement :: Accessibility Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your a -mail address released in response to a public -records request, do not send electronic mail to this entity. Instead, contact the
office by phone or by traditional mail. If you have any questions, please contact 850.487.1395. -Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter
455, F.S. must provide the Department with an email address if they have one. The emails provided may be used for official communication with the licensee. However email addresses are public record. If you
do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please
click er .
Product Approval Accepts:
~eR ® fChe_ck
Credit Card
Safe
-ONEMOletc.
APPENDIX 1: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
TABLE DECK APPLICATION TYPE DESCRIPTION PAGE
1A Wood New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 5
1B Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded.lnsulation, Bonded Roof Cover 6-12
1C Wood New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 1244
1D Wood New, Reroof (Tear -Off) or Recover B-1 Mech. Attached, Base Insulation, Bonded Top Insulation, Bonded Roof Cover 14-15 .
1E Wood New, Reroof (Tear -Off) or Recover C-1 Mech. Attached Insulation, Bonded Roof Cover 15-19
117, Wood New, Reroof (Tear -Off) or Recover D-2 Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 19-23
1G Wood New or Reroof (Tear -Off). E-2 Non -Insulated, Mech. Attached Base Sheet (nails), Bonded Roof Cover 23-29
1H
Wood.
New, Reroof (Tear -Off) or Recover
E-2
Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover
29-36
11
Wood
New or Reroof (Tear -Off)
F
Non -Insulated, Bonded Roof Cover
37
2A
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
B-1
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
38-43
2B ,
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
C-1
Mech. Attached Insulation, Bonded Roof Cover
44-50
2C
Steel or Structural concrete
New, Reroof (Tear -Off) or Recover
D-2
Insulated; Mech. Attached Base Sheet; Bonded Roof Cover
51-53
2D
Steel or Structural concrete
New,. Reroof (Tear -Off) or Recover
D-2
Insulated, Mech. Attached Velociflex, Bonded Roof Cover
53-55
3A -.
Structural concrete
New or Reroof (Tear -Off)
A-1
Bonded Insulation, Bonded Roof Cover
56-68
3B
Structural concrete
New or Reroof (Tear -Off) _
F
Non -Insulated, Bonded Roof Cover
68
4A
Lightweight concrete
New or Reroof (Tear -'Off)
A-1
Bonded Insulation, Bonded Roof Cover
69-73
4B
Lightweight concrete
New or Reroof (Tear -Off)
A 2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover ti
73-47
4C
Lightweight concrete
New or Reroof (Tear -Off)
E-2
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
74-78
5A
Cementitious wood fiber
Reroof (Tear -Off)
A-1
Bonded .Insulation,.Bonded Roof Cover
79-80
5B
Cementitious wood fiber
Reroof,(Tear-Off) or Recover
A-2
Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover
80-82
5C
Cementitious wood fiber
Reroof (Tear -Off) or Recover
B-1
Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover
82.
SD
Cementitious wood fiber
Reroof (Tear -Off) or Recover
C-1
Mech. Attached Insulation, Bonded Roof Cover
83
5E
Cementitious wood fiber
Reroof (Tear -Off) or Recover
E-2
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
83
6A
Existing gypsum
Reroof (Tear -Off) -
A-1
Bonded Insulation, Bonded Roof Cover
84-88
6B
Existing gypsum
Reroof (Tear -Off) or Recover
A-2
Mech. Attached Anchor Sheet,.Bonde.d Insulation, Bonded Roof Cover
88
6C
Existing gypsum
Reroof (Tear -Off) or Recover
C-1
Mech. Attached Insulation, Bonded Roof Cover
88
6D
Existing gypsum
Reroof (Tear -Off) or Recover
E-2
Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover
88.
7A
Various
Recover
A-1
Bonded Insulation, Bonded Roof Cover
89-94
7B
Various
Recover
F
Non -Insulated, Bonded Roof Cover
94
NEMO ETC, LLC Evaluation Report P9290,02.08-1125 for FL1654-1127
Certificate of Authorization 932455 .. 7T" EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020
©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 1 of 94
NNEMOjetc.
The following notes apply to the systems outlined herein:
1 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having
Jurisdiction.
2 Fasteners shall be of sufficient length for the following engagements:
➢ Wood Deck: Minimum 1-inch plywood penetration or wood plank embedment.
➢ Steel Deck: Minimum 0.75-inch steel penetration and engage the top flute of the steel deck.
➢ Structural Concrete: Minimum 1-inch embedment into pilot hole in accordance with published installation instructions.
3 Unless otherwise noted, insulation may be any one layer or combination of FBC Approved (Local or Statewide) board(s) that meet FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof
cover.
4 Minimum 200 psi, minimum 2-inch thick FBC Approved lightweight insulating concrete may be substituted for rigid insulation board for System Types B-1, C-1, C-2, D-1 or D-2, whereby fasteners are installed
through the lightweight insulating concrete to engage the structural deck. The structural deck shall be of equal or greater type, thickness and strength to the steel and structural concrete deck listings. Roof
decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. This is a wind uplift resistance allowance and does not purport to address
non -wind -uplift -related issues, such as deck venting or moisture levels within the LWIC and the potential effect on overlying components.
5 Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (February 2020).
6 Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published
instructions.
> Hot asphalt (HA): Full coverage at 25-30 Ibs/square.
> DuPont INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-inch c.c.
> H.B. Fuller Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
> H.B. Fuller Millennium PG-1 Pump Grade Adhesive (M-PG1): Continuous 0.25 to 0.5-inch wide ribbons, 12-inch o.c.
> OMG OlyBond 500 (013500): Continuous 0.75 to 1-inch wide ribbons, 12-inch o.c. Note: OlyBond Green may be used where OlyBond 500 is referenced.
> OlyBond Classic (OB Classic): Full coverage at 1 gal/square.
> ICP Adhesive & Sealants Polyset CR-20: Continuous 2.5-3.5-inch wide ribbons, 12-inch o.c.
> Note: When multiple loyers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, board joints shall be staggered.
> Note: The maximum edge distance from the adhesive ribbon to the edge of the insulation board shall be not less than one-half the specified ribbons spacing.
7 Unless otherwise noted, all insulations are flat -stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following
Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MDP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in
the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed in the table.
> H.B. Fuller Millennium One Step Foamable Adhesive (M-OSFA): MDP = -157.5 psf (Min. 0.5-inch thick)
> H.B. Fuller Millennium PG-1 Pump Grade Adhesive (M-PG1): MDP = -157.5 psf (Min. 0.5-inch thick)
> OMG OlyBond 500 (OB500): MDP = -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3)
> OMG OlyBond 500 (OB500): MDP = -187.5 psf (Min. 0.5-inch thick 150 95+GL)
> OMG OlyBond 500 (OB500): MDP = -315.0 psf (Min. 0.5-inch thick ENRGY 3)
> OMG OlyBond 500 (013500): MDP = -487.5 psf (Min. 0.5-inch thick ACFoam II)
> ICP Adhesives & Sealants Polyset CR-20: MDP = -117.5 psf (Min. 1.0-inch thick)
8 For adhered roof insulation and board -size: Unless otherwise noted, refer to Section 2.2.10.6.2 of FM Loss Prevention Data Sheet 1-29 (February 2020).
9 For mechanically attached components or partially -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed at least the Zone 1 PRIME design pressure determined in
accordance with FBC Chapter 16. Elevated pressure zones shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are
NEMO ETC, LLC Evaluation Report P9290.02.08-R25 for FL1654-R27
Certificate of Authorization #32455 7- EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020
©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 2 of 94
ONEMOletc.
ANSI/SPRI WD1, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (February 2020) for Zone 2/3 enhancements.
10 For assemblies with all components fully bonded, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No
rational analysis is permitted for these systems.
11 For mechanically attached components over existing decks, fasteners -shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105.
12 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be
installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance shall be conducted on mock-ups of the proposed new roof assembly. For bonded
insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority
Having Jurisdiction, as documented through field uplift testing. Field uplift testing shall be in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
13 Refer to FBC 1511 for requirements and limitations regarding recover installations. For Structural Concrete Deck or Recover Applications using System Type C-1, C-2, D-1 or D-2, the insulation is optional.
Alternatively, an FBC Approved insulation board or coverboard may be used as a separation layer. Board products shall be preliminarily attached prior to roof cover installation (Note 5 herein). The separator
component shall be documented as meeting FBC 1505 and, for foam plastic, FBC Chapter 26, when installed with the roof cover in Recover applications.
14 Lightweight insulating concrete (LWIC) shall be cast in accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWIC is referenced, refer to current
LWIC Product Approval for specific deck construction and limitations. Unless otherwise noted, for systems where specific LWIC is not referenced, the minimum design mix shall be 300 psi. In all cases, the
minimum top -coat thickness is 2-inches. For LWIC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. For "pre-existent" LWIC references, listings were established through testing
over lightweight concrete cast using only foaming agent (ASTM C896), water and Portland cement (ASTM C150), with no proprietary additives, in accordance with procedures adopted by Miami -Dade BCCO
(FBC CER1592). Use of these listings in new construction or re -roof (tear -off) applications is at the discretion of the Designer or Record and Authority Having Jurisdiction.
15 For bonded membrane applications, unless otherwise noted, refer to the following.
MEMBRANE / ADHESIVE COMBINATIONS
REFERENCE
LAYER
MATERIAL
APPLICATION
BP -AA
Base Ply
One or more plies Polyglass G2 Base, FBC Approved ASTM D4601, Type II
Base and PI sheets,
( Y
PI Y
One or more lies Polyglass PI IV, Polyglass PI VI, FBC A
plies Yg Y Yg Y Approved ASTM D2178, Type IV or VI
Hot Asphalt at 20-40
Asphalt -Applied)
Note:
Asphalt -applied sheets or insulation shall not be applied to poly film surfaced membranes.
Ibs/square
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield HT
SBS-CAI
Cap Ply
Elastoshield HT G, Elastoshield HT G FR, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex 56 HP, Elastoflex 56 G, Elastoflex
PG350 at 1.5-2.0
gal/square
S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply
One ply Elastobase (sand/sand), Elastoflex V, Elastoflex S6, Elastoflex 56 HP
SBS-CA2
Cap Ply
Elastoshield HT G, Elastoshield HT G FR, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G, Elastoflex
us at 1.5-2.0
gal/squarea
gal/square
S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Base Ply or Ply
One or more plies Elastobase (sand/sand or poly/sand), Elastobase P (sand/sand or poly/sand), Elastoflex V, Elastoflex S6, Elastoflex
SBS-AA
S6 HP, Elastoshield HT
Hot Asphalt at 20-40
(SBS, Asphalt -Applied)
Cap Ply
Elastoshield HT G, Elastoshield HT G FR, Elastoflex V, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6 G,
Ibs/square
Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (sand -backed), Polyfresko G SBS FR (sand -backed)
Note:
Asphalt -applied sheets or insulation shall not be applied to poly film surfaced membranes.
Base Ply or Ply
One or more plies Elastobase (sand/poly), Elastobase (poly/poly), Elastoflex V, Elastoflex S6, Elastoflex S6 HP, Elastoshield HT
SBS-TA
Elastoshield HT G, Elastoshield HT G FR, Elastoflex V, Elastoflex V G, Elastoflex V G FR, Elastoflex S6, Elastoflex S6 HP, Elastoflex S6
(SBS, Torch -Applied)
Cap Ply
G, Elastoflex S6 G FR, Elastoshield TS G, Elastoshield TS G FR, Polyfresko G SBS (poly -film backed), Polyfresko G SBS FR (poly -film
Torch -Applied
backed)
NEMO ETC, LLC
Certificate of Authorization #32455
©2018 NEMO ETC, LLC
7T" EDITION (2020) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (954) 233-1330
Evaluation Report P9290.02.08-R25 for FL1654-RZ7
Revision 25: 09/30/2020
Appendix 1, Page 3 of 94
ONEMOjetc.
MEMBRANE / ADHESIVE COMBINATIONS
REFERENCE
LAYER
MATERIAL
APPLICATION
SBS-SA-H
Base Ply
Elastobase SA
Self -adhering (followed
(SBS, Self -Adhering, Hybrid Systems)
by torch -applied sheet)
Base Ply
One or more plies Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V Plus, Elastoflex SA V Plus FR, Elastoflex SA Base HD
SBS-SA
Cap Ply
Elastoflex SA P, Elastoflex SA P FR, Polyreflect
(SBS, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substrates for SBS-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Elastobase (poly/sand) or Elastobase (poly/poly).
APP-CA1
Cap Ply
Polyflex G FR
PG350 at 1.5-2.0
gal/square
APP-TA
Base Ply or Ply
One or more plies Polyglass Base, Polyflex, Polybond
Torch -Applied
(APP, Torch -Applied)
Cap Ply
Polyflex, Polyflex G, Polyflex G FR, Polybond, Polybond G, Polyfresko G, Polyfresko G FR
APP-SA-H
Base Ply
Polyflex SA Base
Self -adhering (followed
(APP, Self -Adhering, Hybrid Systems)
by torch -applied sheet)
Cap Ply
Polyflex SA P, Polyflex SA P FR, Polyfresko G SA, Polyfresko G SA FR, Polykool
APP-SA
(APP, Self -Adhering)
Note:
Unless otherwise noted, permissible membrane substrates forAPP-SA are limited to the SBS-SA Base Ply options herein,
Self -Adhering
Elastobase (poly/sand) or Elastobase (poly/poly).
16 Vapor.barrier options for use over structural concrete deck followed by bonded insulation carry the following MDP limitations. The lesser of the MDP listings below vs. those in Table 3A applies.
VAPOR BARRIER OPTIONS; STRUCTURAL CONCRETE DECK; FOLLOWED BY ADHESIVE -APPLIED INSULATION PER TABLE 3A:
OPTION
#
PRIMER
VAPOR BARRIER
INSULATION ADHESIVE
MDP
(PSF)
TYPE (NOTE 15)
APPLICATION
C-VB-1.
PG100
Elastoflex SA V Plus
Self -Adhering
D-IS or CR-20, 12-inch o.c.
-60.0
C-VB-2.
PG100
Polyglass Base
Torch -applied
D-IS or CR-20, 12-inch o.c.
-75.0
C-VB-3.
PG100
Elastoflex SA P
Self -Adhering
D-IS, 12-inch o.c.
-75.0
C-VB-4.
PG100
Elastoflex SA P
Self -Adhering
M-OSFA, 12-inch o.c.
-157.5
C-VB-5.
PG100
Elastoflex SA P
Self -Adhering
CR-20, 12-inch o.c.
-270.0
C-VB-6.
PG100
Elastoflex SA V, Elastoflex SA V FR, Elastoflex SA V Plus, Elastoflex SA V Plus FR
Self -Adhering
M-OSFA,.M-PG-1, OB500 or CR-20, 12-inch o.c.
-290.0
C-VB-7.
PG100
SBS-TA (with sanded -top -surface)
Torch -applied
M-OSFA, M-PG-1, OB500 or CR-20, 12-inch o.c.
-290.0
17 The following surfacing may be applied to the Cap Ply without adverse effect on the system wind load performance. Refer to current Florida Product Approval for approved Polyglass and KM Coatings roof coatings
for application limitations and a Roofing Materials Directory for fire ratings associated with coating usage.
SURFACING OPTIONS FOR POLYGLASS MODIFIED BITUMEN ROOF SYSTEMS
OPTION #
SURFACING
FLORIDA PRODUCT APPROVAL
SURF-1.
PG 300
FL10291
SURF-2.
PG 600
FL10291
SURF-3.
PG 650
FL10291
SURF-4.
PG 700
FL10291
SURF-S.
PG 700 QS
FL10291
SURF-6.
PG 800
FL10291
SURF-7.
Polyplus 60
FL10291
NEMO ETC, LLC Evaluation Report 1`9290.02.08-1125 for FL1654-RZ7
Certificate of Authorization #32455 7TH EDITION (2020) FBC NON-HVHZ EVALUATION Revision 25: 09/30/2020
©2018 NEMO ETC, LLC Polyglass Modified Bitumen Roof Systems; (954) 233-1330 Appendix 1, Page 4 of 94
NNEMOletc.
TABLE 11: .... CONSTRUCTION ...... (TEAR -OFF)
SYSTEM TYPE F: .:... ROOF COVER
System Roof Cover (Note 15)
Deck (Note 1) Primer MDP (psf)
No.
Joint Treatment Base Ply Ply Cap Ply
SELF -ADHERING BASE PLY:
APA rated,
W 208
7/16 CAT,
OSB joints are covered with 4-inch wide strips of Elastoflex SA V, rolled into
Elastoflex SA V Plus
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA,
0.418 in.,
None
place to create continuous bond.
or Elastoflex SA V
TA, APP-TA
SBS-TA, APP-TA
52.5
Exposure 1 OSB
Plus FR
W 209
Min. 15/32-
None
None
SBS-SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA,
90.0
inch plywood
TA, APP-TA
SBS-TA, APP-TA
W-210
Min. 15/32-
PG100
None
SBS-SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA,
97.5
inch plywood
TA, APP-TA
SBS-TA, APP-TA
W-211
Min. 15/32-
(Optional) PG100
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled
Elastoflex SA V or
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA,
inch plywood
into place to create continuous bond.
Elastoflex SA V FR
TA, APP-TA
SBS-TA, APP-TA
97.5
W 212
Min. 15/32-
POLYBRITE 745
None
SBS-SA
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA,
105.0
inch plywood
or WB3000
TA, APP-TA
SBS-TA, APP-TA
W-213
Min. 15/32-
(Optional) PG100
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled
Elastoflex SA V Plus
or Elastoflex SA V
(Optional) SBS-SA, SBS-
SBS-SA, APP-SA,
-135.0
inch plywood
into place to create continuous bond.
TA, APP-TA
SBS-TA, APP-TA
Plus FR
HYBRID SYSTEMS WITH SELF -ADHERING APP BASE PLY:
Min. 15/32-
W-214
inch plywood
(Optional) PG100
None
APP SA H
(Optional) APP-TA
APP-TA
90.0
W-215
Min. 15/32-
(Optional) PG100
)
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled
APP-SA-H
(Optional) APP-TA
APP-TA
135.0
inch plywood
into place to create continuous bond.
HYBRID SYSTEMS WITHSELF-ADHERING SBS BASE PLY:
Min. 15/32-
W-216
inch plywood
None
None
SBS-SA-H
(Optional) SBS-TA
SBS-TA
90.0
Min. 15/32-
W 217
inch plywood
PG100
None
SBS-SA-H
(Optional) SBS-TA
SBS-TA
-97.5
Min. 15/32-
Plywood joints are covered with 4-inch wide strips of Elastoflex SA V Plus, rolled
W 218
inch plywood
(Optional) PG100
into place to create continuous bond.
SBS-SA-H
(Optional) SBS-TA
SBS-TA
-97.5
W-219
Min. 15/32-
POLYBRITE 745
None
SBS-SA-H
(Optional) SBS-TA
SBS-TA
105.0
inch plywood
or WB3000
NEMO ETC, LLC
Certificate of Authorization #32455
©2018 NEMO ETC, LLC
7T" EDITION (2020) FBC NON-HVHZ EVALUATION
Polyglass Modified Bitumen Roof Systems; (954) 233-1330
Evaluation Report P9290.02.08-R25 for FL1654-R27
Revision 25: 09/30/2020
Appendix 1, Page 37 of 94
COUNT Y
F L O R 1 D A
Building Permit #
Planning & Development Services Department
Building & Regulations Division
Product Review Affidavit
Owners Name Scott W Shipley
Applicant: Indian River Roofing & Repairs
Product
Opening Design
Pressures
Product Rated
Design Pressure
Manufacturer
Model Number
Product Approval
Number
Glass
Type
Method of Attachment
Windows
Mullions
Fixed Glass
Block Glass
Skylights
Sliding Glass Doors
Swing Type Doors
French Doors
Garage Doors
Hurricane Protection
Roof Ventilation
Roofing Material'�`JitOn•"�
C
C}- Mct+
I?
LIoGA t' 1164 35wp
t"C*yO uwdet
rL Zjc,2\.09-RN
F1,52tS1^Rv
til0 (" fasfw �" °►C
'14'` AC -id 4+/ T%Y. s
Revised 07/22/2014
I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the
wind loads and forces specified by current code provisions.
Name: Signature: seal
Design Prof: Cert. No. Date: