FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: RJM SHAPARD RESIDENCE 2571
Builder Name: RJM BUILDERS
Street: 1530 PINEBROOK
LANE
Permit Office: PORT ST LUCIE
City, State, Zip: FT PIERCE, FL,
Permit Number:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (2740.0 sqft-)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 2400.00 ftz
3. Number of units, if multiple family
1
b. Frame - Wood, Adjacent
R=1 1.0 340.00 ft'
c. N/A
R= ftz
4. Number of Bedrooms
4
d. N/A
R- ftz
5. Is this a worst case?
Yes
10. Ceiling Types (2571.0 sqft.)
Insulation Area
a. Roof Deck (Unvented)
R=20.0 2571.00 ftz
6. Conditioned floor area above grade (ftz)
2571
b. N/A
R= ftz
Conditioned floor area below grade (ftz)
0
c. N/A
R= ftz
7. Windows(400.1 sqft.) Description
Area
11. Ducts
a. Sup: Attic, Ret: Attic, AH: Garage
R ftz
6 144
a. U-Factor: Sgl, U=0.52
316.11 ftz
SHGC: SHGC=0.30
b. U-Factor: Sgl, U=0.53
64.00 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.31
a_ Central Unit
46.5 SEER:14.00
c. U-Factor: Dbl, U=0.52
20.00 ftz
SHGC: SHGC=0.30
U-Factor: N/A
13. Heating systems
kBtu/hr Efficiencyd.
SHGC:
ftz
a. Electric Heat Pump
46.5 HSPF:8.20
Area Weighted Average Overhang Depth: 5.325 ft.
Area Weighted Average SHGC:
0.302
14. Hot water systems
8. Floor Types (2571.0 sqft.)
Insulation Area
a. Electric Tankless
Cap: 1 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 2571,00 ftz
b. Conservation features
EF: 0.920
b. N/A
R= ftz
None
c. N/A
R= ftz
15. Credits
Pstat
Glass/Floor Area: 0.156
Total Proposed Modified Loads: 85.05
PASS
Total Baseline Loads 86.93
I hereby certify that the plans and specifications covered by
Review of the plans and
VIAE S7,4?,
this calculation are in compliance wit
the Florida Energy
specifications covered by this
A., O
�'''
Code,
calculation indicates compliance
yam,,, = r,• •,.•
_
with the Florida Energy Code.
F. +n,r, �.,, .._;' ;.•,;;. `� p
PREPARED BY:
Before construction is completed
DATE: _A__
this building will be inspected for
)i d
°
compliance with Section 553,908
*
I hereby certify that this building, as
gned, is in compliance
Florida Statutes.
r�(;pD
with the Florida Energy Code.
WE
OWNER/AGENT:
BUILDING OFFICIAL. -
DATE:
DATE:
Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2,1.
Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4,1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 6.00 ACH50 (R402.4.1.2).
10/8/2020 10:13 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPIIT SUMMARY ril-IFr_Kl 1CT RGIanOT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
RJM SHAPARD RESIDENCE Bedrooms: 4
User Conditioned Area: 2571
Total Stories: 1
1 Worst Case: Yes
RJM BUILDERS Rotate Angle: 270
PORT ST LUCIE Cross Ventilation:
Whole House Fan:
Single-family
New (From Plans)
Address Type:
Lot #
Block/Subdivision:
PlatBook:
Street:
County:
City, State, Zip:
Street Address
1530 PINEBROOK LAN
St. Lucie
FT PIERCE,
FL
CLIMATE
J
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70 75 299
62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
2571 23139
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms InfilID Finished Cooled Heated
1
Main
2571 23139 Yes 8
4 1 Yes
Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Wood Carpet
1 Slab -On -Grade Edge Insulatio
Main 214 ft 0
--Tile
2571 ft2 _W
0 0 1
ROOF
/
V #
Roof Gable Roof
Type Materials Area Area Color
Rad Solar SA Emitt
Barr Absor. Tested
Emitt Deck Pitch
Tested lnsul. (deg)
1
Hip Composition shingles 2785 ft2 0 ft2 Light
N 0.96 No 0.9
No 20 22.6
ATTIC
/
y #
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Partial cathedral cei
Unvented 0 _ 2571 ft2 N Y
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Unvented)
Main 0 Blown
2571 ft2 0.11
Wood
10/8/2020 10:13 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
FORM R405-2017 INPI IT CI IMIUAOV rucrvi te-r n�nr%mr
WALLS
nrnt Tn Wall TypeAdjacent
Space
Cavity
Width
Height
Sheathing Framing
Solar Below
D
- 1
N=>W Exterior
Concrete Block - Int Insul
Main
4.1
55
10
550.0 ft'
0
0.05
0
2
NE=>NW Exterior
Concrete Block - Int Insul
Main
4.1
9
10
90.0 ft'
0
0.05
0
3
E=>N Exterior
Concrete Block - Int Insul
Main
4.1
54
10
540.0 ft2
0
0.05
0
- 4
SE=>NE Exterior
Concrete Block - Int Insul
Main
4.1
10
10
100.0 ft'
0
5
S=>E Exterior
Concrete Block - Int Insul
Main
4.1
31
10
310.0 ft2
0
0.05
0.05
0
6
SW=>SE Exterior
Concrete Block - Int Insul
Main
4.1
5
10
50.0 ft2
0
0.05
0
7
W=>S Exterior
Concrete Block - Ent Insul
Main
4.1
70
10
700.0 ft2
0
0.05
0
0
8
NW=>S Exterior
Concrete Block - Int Insul
Main
4.1
6
10
60.0 ft'
0
0.05
9
E=>N Garage
Frame - Wood
Main
11
8
10
80.0 ft2
0.5
0.05
0
0
10
S=>E Garage
Frame - Wood
Main
11
23
10
230.0 ft'
0.5
0.05
0
11
W=>S Garage
Frame - Wood
Main
11
3
10
30.0 ft2
0.5
0.05
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
_...___
Ft
In
Ft In
S=>E Insulated
Main
None
.46
6
8
48 ft2
2 S=>E Insulated
Main
None
.46
3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation
=> chan ed to Worst Case.
/
V
Wall
Overhang
# Ornt ID
Frame Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 N=>W 1
Metal Single (Tinted)
Yes
0.52
0.3
N
22.5 ft2
7 ft 0 in
1 ft 0 in
None
None
2 NE=>NW 2
Metal Single (Tinted)
Yes
0.52
0.3
N
33.3 ft2
8 ft 0 in
1 ft 0 in
None
None
3 N=>W 1
Metal Single (Tinted)
Yes
0.53
0.31
N
64.0 ft'
10 ft 0 m
1 ft 0 in
None
None
4 W=>S 7
Metal Single (Tinted)
Yes
0.52
0.3
N
10.0 ft2
16 ft 0 in
1 ft 0 in
None
None
5 NW=>SW 8
Metal Single (Tinted)
Yes
0.52
0.3
N
10.0 ft'
5 ft 0 in
1 ft 0 in
None
None
6 N=>W 1
Metal Single (Tinted)
Yes
0.52
0.3
N
10.0 ft'
8 ft 0 in
1 ft 0 in
None
None
7 W=>S 7
Metal Single (Tinted)
Yes
0.52
0.3
N
64.0 ft'
5 ft 0 in
1 ft 0 In
None
None
8 N=>W 1
Metal Single (Tinted)
Yes
0.52
0.3
N
45.0 ft'
1 ft 0 in
1 ft 0 in
None
None
9 W=>S 7
Metal Single (Tinted)
Yes
0.52
0.3
N
17.8 ft2
1 ft 0 in
1 ft 0 in
None
None
10 E=>N 3
Metal Single (Tinted)
Yes
0.52
0.3
N
12.0 It'
1 ft 0 in
1 ft 0 in
None
None
11 E=>N 3
Metal Single (Tinted)
Yes
0.52
0.3
N
30.0 ft'
1 ft 0 in
1 ft 0 in
None
None
12 SE=>NE 4
Metal Single (Tinted)
Yes
0.52
0.3
N
6.0 ft2
1 ft 0 in
1 ft 0 in
None
None
13 S=>E 5
Metal Single (Tinted)
Yes
0.52
0.3
N
22.5 ft2
1 ft 0 in
1 ft 0 in
None
None
14 S=>E 5
Metal Single (Tinted)
Yes
0.52
0.3
N
18.0 ft'
16 ft 0 in
1 ft 0 in
None
None
15 S=>E 5
Metal Single (Tinted)
Yes
0.52
0.3
N
15.0 ft'
1 ft 0 in
1 ft 0 in
None
None
16 SE=>NE 4
Metal Double (Clear)
Yes
0.52
0.3
N
10.0 ft'
1 ft 0 in
1 ft 0 in
None
None
17 SW -SE 6
Metal Double (Clear)
Yes
0.52
0.3
N
10.0 ft2
1 ft 0 in
1 ft 0 in
None
None
10/8/2020 10:13 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405-2017 IMPI IT CI IRAUADV f%uCr VI ie-r ocovto-r
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter Avg, Wall Height Exposed Wall Insulation
1
420 ft2
420 ft2
64 ft loft 1
INFILTRATION
# Scope
Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse
Proposed ACH(50)
.000343
2313.9 127.03 238.9 _ .1246 6
HEATING SYSTEM
#
System Type
Subtype
Speed Efficiency Capacity Block
Ducts
1
Electric Heat Pump/
None
Singl HSPF.8.2 46.5 kBtu/hr 1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Subtype Efficiency Capacity Air Flow SHR Block
Ducts
1
Central Unit/
None
Sing[ SEER: 14 46.5 kBtu/hr 1395 cfm 0.75 1
sys#1 W
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use SetPnt Conservation
1
Electric Tankless
Garage
0.92 1 gal 70 gal 120 deg None
m
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume FEF
None
None
ft'
DUCTS
J----
#
Supply ----
Location R-Value Area
---- Return ---- Air CFM 25 CFM25 HVAC #
Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool
1
Attic 6 144 ft'
Attic
41 ft2 Default Leakage Garage (Default) (Default)
1 1
10/8/2020 10:13 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R4D5-2fM7 IAIDI IT CI IRARRAw nurwr o■.T
v■■nnr��IL 1 w IL-Vr%L.1%.3 1 rxr-f-VM I
TEMPERATURES
Programable Thermostat: Y
Ceiling
Fans:
Cooling Jan
Venting Jan
Feb
�Xl Feb
Mar
�X�
�X�
A r
Ma Jun Jul
AugSe
Oct
Nov
Dec
Mar
Apr
May Jun Jul
rj
ri Aug
Sep
l7(� Oct
�X� Nov
Dec
Thermostat Schedule:
HERS 2006 Reference
Hours
Schedule Type
1
2
3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM
PM
78
80
78
80
78
78
78 78 78
78
78
80
80
80
80
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM
PM
78
78
78
78
78
78
78 78 78
78
78
78
78
78
78
78
78 78
78
78
78
78
78
78
Heating (WD)
AM
PM
66
68
66
68
66
68
66 66 68
68
68
68
68
68
68
68
68 68
68
68
68
68
66
66
Heating (WEH)
AM
PM
66
68
66
68
66
68
66 66 68
68
68
68
6B
68
68
68 68 68
68
68
68
68
66
66
MECHANICAL VENTILATION
Type
Supply CFM
Exhaust CFM
Fan Watts HRV Heating System
Run Time Cooling System
None
0
0
0 1 - Electric Heat Pump
0%
1 - Central Unit
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ft2
Oft
0.3
Main
10/8/2020 10:13 AM EnergyGauge& USA 6.0.02 (Rev. 1) - FlaRe$2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance index, the more efficient the home
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Sincile-family
b) Return ducts R
6.0
c) AHU location
Garage
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
46.5
a) Split system SEER
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
2571
d) Room unit/PTAC EER
e) Other
14.0
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.522
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.302
14. Heating system: Capacity
46.5
c) Area
7c,
400.1
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
8.20
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.92
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1081.
11.0
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance
Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
1 la.
0.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
t) Programmable thermostat _
Yes
`Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date: "[ 171-1
Address of New Home: 1530 PINEBROOK LANE City/FL Zip: FT PIERCE, FL
10/8/2020 10:13:10 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 6th Edition (2017)
AA -
Mandato Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 1530 PINEBROOK LANE Permit Number:
FT PIERCE. FL,
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
R402.4.1 Building thermal enveloPW building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
❑ R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907
R402.4.3 Fenestration air leakage Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 L/s/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/t.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
10/8/2020 10 13 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
MANDATORY REQUIREMENTS - (Continued)
R402.4.4 Rooms containing fuel burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-13
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 Us) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
R403.1 controls. SECTION R403 SYSTEMS
R403.1.1 Thermostat provision (Mandatory). At least one thermostat shall be provided for each separate heating and cooling system
❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness shall be verified by testing in accordance with ANSIIRESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(0, (g) or (i), Florida Statutes, to be "substantially leak free' in
accordance with Section R403.3.3,
R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one of the following methods:
Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the
manufacturer's air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during the test.
Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code.
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 105°F (41 °C)
or below 55'17 (1 YC) shall be insulated to a minimum of R-3.
R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
R403.5.1 Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1 2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
❑ R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
10/8/2020 10:13 AM EnergyGaugee USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.5.5 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3112 inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the Intended use. The minimum temperature
setting range shall be from 1007 to 1407 (38°C to 60°C).
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
ElR403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
shall meet the following criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the space(s) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFM/WATT)
AIRFLOW RATE MAXIMUIV
(CFM)
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm = 28.3 L/min. a. When tested in accordance with HVI Standard 916
10/8/2020 10:13 AM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1,15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturer's product lines. The corresponding latent capacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
2. calculated total sensible load but not less than 80 percent of that load.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and ice -melting systems, supplied through energy service to the building,
shall Include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10°C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C).
❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions:
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
❑ R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
10/8/2020 10:13 AM EnergyGauge@ USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
R403.10.5 Heat pump pool heaters. Heat pump pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas (Mandatorynhe energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
10/8/2020 10:13 AM EnergyGaugee USA 6,0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: RJM SHAPARD RESIDENCE 2571 Builder Name: RJM BUILDERS
Street: 1530 PINEBROOK LANE Permit Office: PORT ST LUCIE
City, State, Zip: FT PIERCE, FL, Permit Number:
x
Owner Jurisdiction:
w
Design Location: FL, Fort Pierce
z
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and silt plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
above -garage
insulation.
maintain permanent contact with the underside of
and cantilevered
subfloor decking, or floor framing cavity insulation
floors)
shall be permitted to be in contact with the top side
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
a In 9d ditinn insp—tinn
_.... -__.-. _.., .....r,,,,,,,,, ,,, I" „a,,,, 1- 4 - ni awvivanuc vnui tilt: IJIUV1510115 OT ILA -4UU.
10/8/2020 10:13 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation. 6th Edition
Jurisdiction:
Permit #:
Job Information
Builder: RJM BUILDERS Community: Lot: NA
Address: 1530 PINEBROOK LANE
City: FT PIERCE State: FL Zip:
Air Leakage'test Results Passing results must meet either the Performance, Prescriptive, or ERI Method
PRESCRIPTIVE METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding 7 air
changes per hour at a pressure of 0.2 inch w.g. (50 Pascals) in Climate Zones land 2.
( PERFORMANCE or ERI METHOD -The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding
the selected ACH(50) value, as shown on Form R405-2017 (Performance) or R406-2017 (ERI), section labeled as infiltration. sub -section ACH50.
ACH(50) specified an Form R405-2017-Energy Cale (Performance) or R406-2017 (ERI): ' 6,000
x 60 = 23139 = Method for calculating building volume:
CFM(50) Building Volume ACH(50)
O Retrieved from architectural plans
FPASS
40 Code software calculated
When ACH(50) is less than 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set forth in Section
489.105(3)(f), (9), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
Testing Company
Company Name: Phone.
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester:
License/Certification #: Issuing Authority:
10/8/2020 10:13:17 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Residential System Sizing Calculation
Summary
Project Title:
1530 PINEBROOK LANE RJM SHAPARD RESIDENCE 2571
FT PIERCE, FL
10/8/2020
Location for weather data: Fort Pierce, FL - Defaults: Latitude(27.48) Altitude(25 ft.) Temp Range(L)
Humidi data: Interior RH 50%
Outdoor wet bulb 78F Humidity difference 62 r.
Winter design temperature(TMY3 99%) 40
F
Summer design temperature(TMY3 99%) 91
F
Winter setpoint
70
F
Summer setpoint
75
F
Winter temperature difference
30
F
Summer temperature difference
16
F
Total heating load calculation
43149
Btuh
Total cooling load calculation
45326
Btuh
Submitted heating capacity
% of calc
Btuh
Submitted cooling capacity
% of calc
Btuh
Total (Electric Heat Pump)
107.8
46500
Sensible (SHR = 0.75)
96.5
34875
Heat Pump + Auxiliary(O.OkW)
107.8
46500
Latent
126.5
11625
Total Electric Heat Pump)
102.6
46500
WINTER CALCULATIONS
Winlar Wan4inn I noif ffnr 9R71 enA\
Load component
Load
Window total
400
sqft
6261
Btuh
Wall total
2272
sqft
9649
Btuh
Door total
68
sqft
938
Btuh
Ceiling total
2571
sqft
3690
Btuh
Floor total
2571
sqft
7576
Btuh
Infiltration
77
cfm
2536
Btuh
Duct loss
12498
Btuh
Subtotal
43149
Btuh
Ventilation
0
cfm
0
Btuh
TOTAL HEAT LOSS
1
43149
Btuh
Summer Coolinq Load (for 2571 saft
wens(z24X)
Floors(17.6%)
SUMMER CALCULATION
Load component
Load
Window total
400 sqft
11177
Btuh
Wall total
2272 sqft
5146
Btuh
Door total
68 sqft
970
Btuh
Ceiling total
2571 sqft
3198
Btuh
Floor total
0
Btuh
Infiltration
58 cfm
1014
Btuh
Internal gain
6240
Btuh
Duct gain
8394
Btuh
Sens. Ventilation
0 cfm
0
Btuh
Blower Load
0
Btuh
Total sensible gain
36139
Btuh
Latent gain(ducts)
5156
Btuh
Latent gain(infiltration)
2430
Btuh
Latent gain (ventilation)
0
Btuh
Latent gain(internal/occupants/other)
1600
Btuh
Total latent gain
9186
Btuh
TOTAL HEAT GAIN
1 45326
Btuh
�rtNiiSllib �
Ceilings(7.1%)
Walls(11,454) AA
Doors(2.1%)
Infll.(7.6%)
Ducts{29.la°%)
Ceilings(8616)
windows(114A)
Ducts(290X)
Windows(24.7%)
EnergyGaugelD a S' '
PREPARED BY:
DATE: Z
EnergyGauge® / USRCZB v6.1.04
Latentint(3.5 )]
Int.Gain(13.8%)
System Sizing Calculations - Summer
Residential Load - Room by Room Component Details
Project Title:
1530 PINEBROOK LANE RJM SHAPARD RESIDENCE 2571
FT PIERCE, FL
10/8/2020
Reference City: Fort Pierce, FL Temperature Difference: 16.OF(TMY3 99%) Humidity difference: 62gr.
This calculation is for Worst Case. The house has been rotated 315 degrees.
Type*
Overhang
Window Area(sgft)
HTM
Load
Window
Panes SHGC U InSh
IS
Omt
Len
H t
Gross
Shaded Unshadec
Shaded Unshaded
1
1 NFRC 0.30, 0.52 No
No
NW
7.Oft
1.0ft
22.5
0.0 22.5
15
29
648
Btuh
2
1 NFRC 0.30. 0.52 No
No
N
8.Oft
1.0ft
33.3
0.0 33.3
15
15
491
Stuh
3
1 NFRC 0.31, 0.53 No
No
NW
10.Of
1.0ft
64.0
0.0 64.0
15
30
1897
Btuh
4
1 NFRC 0,30. 0.52 No
No
SW
16.Of
1.0ft
10.0
10.0 0.0
15
29
147
Btuh
5
1 NFRC 0.30, 0.52 No
No
W
5.0ft
1.0ft
10.0
6.3 3.7
15
37
231
Btuh
6
1 NFRC 0.30, 0.52 No
No
NW
8.Oft
1.0ft
10.0
0.0 10.0
15
29
288
Btuh
7
1 NFRC 0.30, 0.52 No
No
SW
5.Oft
1.0ft
64.0
62.4 1.6
15
29
966
Btuh
8
1 NFRC 0.30. 0.52 No
No
NW
1.0ft
1.0ft
45.0
0.0 45.0
15
29
1296
Btuh
9
1 NFRC 0.30, 0.52 No
No
SW
1.0ft
1.0ft
17.8
2.0 15.7
15
29
493
Btuh
10
1 NFRC 0.30, 0.52 No
No
NE
1.0ft
1.0ft
12.0
0.0 12,0
15
29
346
Btuh
11
1 NFRC 0.30, 0.52 No
No
NE
Loft
1.0ft
30.0
0.0 30.0
15
29
864
Btuh
12
1 NFRC 0.30. 0.52 No
No
E
1.0ft
1.0ft
6.0
0.0 6.0
15
37
225
Btuh
13
1 NFRC 0.30, 0.52 No
No
SE
1.Oft
1.0ft
22.5
3.4 19.1
15
29
612
Btuh
14
1 NFRC 0.30, 0.52 No
No
SE
16.Of
1.0ft
18.0
18.0 0.0
15
29
265
Btuh
15
1 NFRC 0.30, 0.52 No
No
SE
1.0ft
1.0ft
15.0
2.3 12.7
15
29
408
Btuh
16
2 NFRC 0.30, 0.52 No
No
E
1.0ft
1.0ft
10.o
0.0 10.0
15
37
374
Btuh
17
2 NFRC 0.30, 0.52 No
No
S
1.0ft
1.0ft
10.0
10.0 0.0
15
16
147
Btuh
Window Total
400 s ft
9700
Btuh
Walls
Type
U-Value
R-Value
Area(sgft)
HTM
Load
Cav/Sheath
1
Concrete Blk,Hollow- Ext
0.15
4.1/0.0
408.5
2.4
975
Btuh
2
ConcreteBlk,Hollow -Ext
0.15
4.1/0.0
56.7
2.4
135
Btuh
3
Concrete Blk,Hollow -Ext
0.15
4.1/0.0
498.0
2.4
1189
Stuh
4
Concrete Blk,Hollow - Ext
0.15
4.1/0.0
84.0
2.4
201
Btuh
5
Concrete Blk,Hollow - Ext
0.15
4.1/0.0
206.5
2.4
493
Btuh
6
Concrete Blk,Hollow - Ext
0.15
4,110.0
40.0
2.4
96
Btuh
7
Concrete Blk,Hollow - Ext
0.15
4.1/0.0
608.2
2.4
1452
Btuh
8
ConcreteBlk,Hollow -Ext
0.15
4.110.0
50.0
2.4
119
Btuh
9
Frame - Wood - Adj
0.09
11.010.0
80.0
1.5
121
Btuh
10
Frame - Wood - Adj
0.09
11.0/0.0
210.0
1.5
319
Btuh
11
Frame - Wood - Adj
0.09
11.0/0.0
30.0
1.5
46
Btuh
Wall Total
2272 (s ft)
5146
Btuh
Doors
Type
_._.
Area (sqft)
HTM
Load
1
Insulated - Exterior
48.0
14.3
684
Btuh
2
Insulated - Garage
20.0
14.3
285
Btuh
Door Total
68 s ft
970 Btuh
Callings
Type/Color/Surface
U-Value
R-Value
Area(sqft)
HTM
Load
1
Unvented Attic/Light/Shingle
0.048
0.0120.0
2571.0
1.24
3198
Btuh
Ceiling Total
2571 s ft
3198 Btuh
Ftoors
Type
R-Value
Size
HTM
Load
1
Slab On Grade
0.0
2571 (ft-perimeter)
0.0
0
Btuh
Floor Total
2571.0 (s ft)
0 Btuh
Zone Envelope Subtotal:
19014 Btuh
EnergyGaugeO / USRCZB v6.1.04 Page 1
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate: FL_VERO BEACH_MUNICIPAL_A
1530 PINEBROOK LANE RJM SHAPARD RESIDENCE 2571
FT PIERCE, FL
10/8/2020
Infiltration
Internal
ain
Type Wholehouse ACH Volume(cuft) Wall Ratio CFM=
Natural 0.15 23139 1.00 57.7
Occupants Btuh/occupant Appliance
8 X 230 + 4400
Load
1014 Btuh
Load
6240 Btuh
Sensible Envelope Load:
26269 Btuh
Duct load
-Average sealed, Su ly(R6.0-Attic), Return(R6.0-Attic) DGM of 0.303
7947 Btuh
Sensible Zone Load
34216 Btuh
T .e following window Lxcur trrn will be assigned to the system loads.
Wt do ows JUIy excursion for Sy-s t—e T 1 i 1477 Btuh
Excursion Subtotal: 1477 Btuh
Duct load
447 Btuh
Sensible Excursion Load 1924 Btuh
EnergyGauge®/ USRCZB v6.1.04 Page 2
Manual J Summer Calculations
Residential Load - Component Details (continued)
Project Title: Climate:FL_VERO_BEACH_MUNICIPAL_A
1530 PINEBROOK LANE RJM SHAPARD RESIDENCE 2571
FT PIERCE, FL
10/8/2020
WHOLE HOUSE TOTALS _
a
Sensible Envelope Load All Zones
27746 Btuh
Sensible Duct Load
8394 Btuh
Total Sensible Zone Loads
36139 Btuh
Sensible ventilation
0 Btuh
Blower
0 Btuh
Whole House
Total sensible gain
36139 Btuh
Totals for Cooling
Latent infiltration gain (for 62 gr. humidity difference)
2430 Btuh
Latent ventilation gain
0 Btuh
Latent duct gain
5156 Btuh
Latent occupant gain (8.0 people @ 200 Btuh per person)
1600 Btuh
Latent other gain
0 Btuh
Latent total gain
9186 Btuh
TOTAL GAIN
45326 Btuh
EQUIPMENT
1. Central Unit # 46500 Btuh
'Key: Window types (Panes - Number and type of panes of glass)
(SHGC - Shading coefficient of glass as SHGC numerical value)
(U - Window U-Factor)
(Irish - Interior shading device: none(No), Blinds(B), Draperies(D) or Roller Shades(R))
- For Blinds: Assume medium color, half closed
For Draperies: Assume medium weave, half closed
For Roller shades: Assume translucent, half closed
(IS - Insect screen: none(N), Full(F) or Half(YZ))
(Ornt - compass orientation)
EnergyGauge® / USRCZB v6.1.04 Page 3
DocuSign Envelope ID: 91809A67-3E6F-47EB-B2A1-B808E7C89F42
DS
Initial
*Due to the nature of materials, such as, granite, tile, cabinets and cultured marble, finishes may vary from
samples in showroom.
Initial
* Builders Risk Insurance will be required after In-house Production meeting and before Lot Prep Starts.
Customer Service will request this from the client in time to obtain the policy. DS
Initial
Customer(s) understand the next available time to make any changes will be at the framing walkthrough. It is
at this time RJM will waive our standard $500 change order fee. The cost of the change and any revision fees
will still apply. After the framing walk through, no changes will be permitted. There will be no more structural
changes at anytime.
FS;
niial
Once this is a fully executed document, a payment must be made in full within three business days. Please
notify the color out representative as soon as the payment has been made so that they can notify nting.
76(
ni ial
DocuSigned by:
�0CU ' '�`"7 3/2/2020
Signa Date
DS
S,d
Customer Initials
FDocuSigned by:
604 6WJA)- r 3/2/2020
----------- ; ... ^
Contractor Signature Date
DS
5 Contractor Initials
FORM R405-2017
,CJp1,i s 1-4 �14 P A .2L,
RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) Method
Applications for compliance with the 2017 Florida Building Code, Energy Conservation via the
residential Simulated Performance Method shall include:
This checklist
U A Form R405 report that documents that the Proposed Design p s gn complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a -ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst -case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report (one page) and an input summary checklist that can
be used for field verification (usually four pages/may be greater).
Energy Performance Level (EPL) Display Card (one page)
C? HVAC system sizing and selection based on ACCA Manual S or per exceptions provided in Section R403.7
,Mandatory Requirements (five pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checklist (Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report (usually one page)
El if Form R405 duct leakage type indicates anything other than "default leakage", then a completed
Form R405 Duct Leakage Test Report (usually one page)
10/8/2020 10.13:05 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software
Page 1 of 1