Loading...
HomeMy WebLinkAboutHealth Dept. Final Approval air 4E APPLICATION #:AP1464259 „ STATE OF FLORIDA PERMIT #:56-SF-2033810 DEPARTMENT OF HEALTH DOCUMENT #:F11564401 �r ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:01/28/2020 FEE PAID:545.00 RECEIPT #:56-PI D-4272810 APPLICANT: GHQ Homes AGENT: Richard Laventure(Layenture&Associates Inc) PROPERTY ADDRESS: 5816 Buchanan Dr Fort Pierce, FL 34982 LOT: 22 BLOCK: 9 SUBDIVISION: Indian River Estates ID#: 3402-603-0071-000-2 CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01] TANK SIZE [11 1090.00 [21 [ ] [271 SURFACE WATER FT [ ] [021 TANK MATERIAL Polypropylene [ ] [281 DITCHES 3$ FT [ ] [031 OUTLET DEVICE [ ] [291 PRIVATE WELLS FT [ ] [041 MULTI-CHAMBERED [ Y N ] [ ] [301 PUBLIC WELLS FT [ ] [051 OUTLET FILTER PolylokPL-68 [ ] [311 IRRIGATION WELLS $3 FT [ ] [0 6] LEGEND 1. 70-143-11 DC4 2. [ ] [32] POTABLE WATER 10 FT [ ] [071 WATERTIGHT [ ] [331 BUILDING FOUNDATIONS 18 FT [ ] [081 LEVEL [ ] [341 PROPERTY LINES 12 FT [ ] [091 DEPTH TO LID [ ] [351 OTHER FT DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [101 AREA [1] 679.2 [21 SQFT [ ] [361 DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX HEADER X [ ] [371 SHOULDERS [ ] [121 NUMBER OF DRAINLINES 1. 6.00 2. [ ] [381 SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [391 STABILIZATION 01/21/2021 [ ] [141 DRAINLINE SLOPE [ ] [151 DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 3.00 [ ] [401 UNOBSTRUCTED AREA [ ] [171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [181 DOSING PUMPS [ ] [421 ALARMS [ ] [191 AGGREGATE SIZE [ ] [431 MAINTENANCE AGREEMENT [ ] [201 AGGREGATE EXCESSIVE FINES [ ] [441 BUILDING AREA [ ] (211 AGGREGATE DEPTH [ ] (451 LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [461 FINAL SITE GRADING [ ] [221 FILL AMOUNT [ ] [471 CONTRACTOR MICHAEL W STUHR (ASHTO [ ] [231 FILL TEXTURE [ ] [481 OTHER INFILTRATOR Quick4 Plus EQ36 LP [ ] [241 EXCAVATION DEPTH ABANDONMENT [ ] [251 AREA REPLACED [ ] [491 TANK PUMPED [ ] [261 REPLACEMENT MATERIAL [ ] [501 TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [ APPROVED / St. Lucie CHD DATE: 12/04/2020 DISAPPROVED Envir ental Specialist I i J Ingram(ENVIRONMENTAL HEALTH) r— FINAL SYSTEM [ APpROVED / DISAPPROVED ]: St. Lucie CHD DATE: 01/21/2021 Environmental Specialist I ian J Ingram(ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1,0.1 AP1464259 EID2033810 s APPLICATION #:AP1464259 Y STATE OF FLORIDA PERMIT #:56-SF-2033810 r DEPARTMENT OF HEALTH DOCUMENT #:F11564401 ONSITE SEWAGE TREATMENT AND DISPOSAL SYSTEM CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:01/28/2020 FEE PAID:545.00 RECEIPT #:56-PID-4272810 Violation Number Comment Comments The system is sized for 4 bedrooms with a maximum occupancy of 8 persons(2 per bedroom),for a total estimated flow of 400 gpd. New ST,filter, and 6x10 long BED DF installed. No violations, system ok to cover. Contractor notified onsite. Needs final inspection for potable water line setback verification,filled system, and final site grading. Final system approved. Contractor and building department emailed final approval. DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 2 of 3 EH Database v 1.0.1 AP1464259 EID2033810