HomeMy WebLinkAboutBlower door test i SustahaBase XEM I:> OiA E I is� G SUSTAINAB lI"Y Envelope Leakage Test Report ( Blower Door Test ) Residential Prescriptive , Performance or ERI Method Compliance 2017 Florida Building Code , Energy Conservation , 6th Edition Jurisdiction : Permit # : WOO oo Job Inf©rmatior, Builder : OL J Community : � rZG� rOL� b� Lot : Address : Unit : City : 1 �. Pit « State : t�(� Zip : 314 e;l !S House S . F : Avg . Ceiling Height : Total Volume : (coo cl Air leakage Test Results Passing results most meet either the Performance, Prescriptive, or ERI Method 0PRESCRIPTIVE METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate or not exceeding 7 air change per hour at a pressure of 0 . 2 " inch wig . ( 50 pascals ) in climate zones 1 and 2 . PERFORMANCE OR ERI METHOD The building or dwelling unit shall be tested and verified as having an air leakage rate of not exceeding the selected ACH ( 50 ) value, as shown on FORM R405 "2017 ( Performance) orR406T2017 ( ERI ), section labeled as infiltration , sub - Ir section ACH . ACH(50) specified on Form R405�2017"Energy Gate (Performance) or R406OO,2017 (ERI) : Pressure & Flow Data ( For Single Point ) Test # House Pressure : Pascals Flow : CFM ( 50 ) Ring Used ACH50 = CFM ( 50 ) x 60 / House Volume = J - Method for calculating building; volume : a PASS FAIL 0 Retrieved from architectural plans Code Software calculated I When ACH ( 50 ) is less than 3 , Mechanical Ventilation installation must i Q Field measured and calculated be verified by building department . Testing . Testing shall be conducted in accordance with ANWRESNET/ICC 380 and reported at a pressure or 0. 2 inch w. g; (50 pascals ) . Testing shall be conducted by either individual as defined . in section 553 , 993 ( 5 ) or (7 ), 1~lorida Statues, or individuals licensed as set forth In Section 489.105 ( 3 ) (f), ( g), ' or ( i ) or an approved third party, A written report of the results of the test shall be signed by the party conducting the test and provided to the code official, Testing shall be performed at any time after creation of all penetrations of the building thermal envelops. Testiing Company Company Name : l�,� Wiz- Phone : 1 hereby verify that the above Air L akage results are in accordance with the 2017 61h Edition Florida Building Code Energy Conservation requireme actor Ong to the compliance method selected above . f Signature of Tester : Date of Test : Printed Name of Tester : License/ Certification # : Issuing Authority : 4 e f &jstainat3ase previously RunBrooks Duct Leakage Test Report Residential Prescriptive , Performance or ERI Method Compliance 2017 Florida Building Code , Energy Conservation , 6th Edition jurisdiction : Permit # : ,job Information Builder : Community : 1 . ),"Lot : � w1 CV (� T Address : 1 Unit : City: State , L Zip : Duct . Leakage Test Results System 1 Prescriptive Method cfm25 (Total ) 10 cfm25 To qualify as " substantially leak free " Qn must be less than or equal to System 2 cfm25 0 . 04 If air handler unit is Installed . If air handler unit is not installed , Qn Total must be less than or equal to 0 . 03 . This testing method System 3 cfm25 meets the requirements in accordance with Section R403 . 3 . 3 . Sum of any additional systems cfm25 a performance / ERI Method cfm25 (Out or Total ) Total of an systems cfm25 To qualify using this method , Qn must not be greater than the proposed duct leakage Qn specified on Form R405 -2017 or R406- 2017 .z Qn . . Leakage Type selected n Form n specified on Form R405-2094 Total of all Total Conditioned yP o Q systems Square Footage R405-2017 (Energy Calc) or R406-2017 (Energy Calc) or 40&2097 PASS FAIL Duct tightness shall be verified by testing in accordance with ANSI / RESNET/ ICC380 by either individuals as defined in Section 553 . 993 ( 5 ) or (7 ), Florida Statutes, or individuals licensed as set forth in Section 489 . 105 (3) (f), (g) or ( i ), Florida Statutes , Testing Company Company Name : � . . �h I hereby verify that the above duct leakage testing results are in accordance with the 2017 6th Edition Florida Building Code Energy Conservation requirements according to the compliance method selected above . Signature of Tester : A Date of Test : Id C Printed Name of Tester : A � 1