Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Fl energy efficiency code
1, File Copy Air 2 7 201? FORM R405-2014 PLt`ic W Orks FLORIDA ENERGY' EFFICIENCY CODE FOR BUIbl-w- cCON°STRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method i Project Name: NEWMAN RESIDENCE Builder Name: MIKE DI FRANCESCO Street: 2275 BROCKSMITH RD Permit Office: ST LUCIE City,State,Zip: FORT PIERCE,FL, Permit Number: Owner: Jurisdiction: 611000 Design Location: FL,ST_LUCIE_CO_INTL County:: St.Lucie(Florida Climate Zone 2) i 1. New construction or existing New(From Plans) 9. Wall Types(2790.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2574.00"ftz b.Frame-Wood,Adjacent R=13.0 216.00;ftz �3. Numb its,of units,if multiple family 1 c.N/A R= ftz 4. Number of Bedrooms 3 d.N/A R= ftz 10.Ceiling Types (1593.0 sqft.) Insulation Area 5. Is this a worst case? No a.Roof Deck(Unvented) R=20.0 1593.00 ftz 6. Conditioned floor area above grade(ftz) 2931 b.N/A R= ftz Conditioned floor area below grade(ftz) 0 c.N/A R= ftz 11.Ducts R ; ftz 7. Windows(309.6 sqft.) Description Area a.Sup:Main,Ret:Main,AH:Main 6 200 a. U-Factor: Dbl,U=0.33 309.60 ftz SHGC: SHGC=0.22 b. U-Factor: N/A ftz 12.Cooling systems kBtu/hr Efficiency SHGC: a.Central Unit 42.0 SEER:16.00 c. U-Factor: N/A ftz SHGC: 13.Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a.Electric Strip Heat 32.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 6.319 ft. 1 Area Weighted Average SHGC: 0.220 14.Hot water systems 1 8. Floor Types (1593.0 sqft.) Insulation Area a.Propane Tankless Cap:1 gallonsEF:0.590 a.Slab-On-Grade Edge Insulation R=0.0 1593.00 ftz b. Conservation features b.N/A R= ftz None c.NIA R= ft2 15.Credits i CF Total Proposed Modified Loads: 80.68 Glass/Floor Area: 0.106 PASS Total Baseline Loads: 90.38 I hereby certify that the plans and specifications covered by Review of the plans and ES this calculation are in compli ce wi the Florida E y specifications covered by this 1, r� < ' = 0� Code. calculation indicates compliance � ,,,,1''�' �t+ tr with the Florida Energy Code. ti r,, � '_` = °'Intl,,�O PREPARED BY Before construction is completed v� DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, " in compliance Florida Statutes. with the Florida Energy Code G'Op,t,�,EI R OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: 1 - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory-sealed in accordance with R403.2.2.1. A Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage test report in accordance with R402.4.1.2. 4/12/2017 1:33 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 1 -b FORM R405-2014 PROJECT i I I ' I Title: NEWMAN RESIDENCE Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 2931 Lot# Owner: Total Stories: 2 Block/SubDivision: #of Units: 1 Worst Case: No PlatBook: Builder Name: MIKE DI FRANCESCO Rotate Angle: 0 Street: 2275 BROCKSIMITH R Permit Office: ST LUCIE i Cross Ventilation: County: St.Lucie Jurisdiction: 611000 Whole House Fan: City,State,Zip: FORT PIERCE, Family Type: Single-family FL, New/Existing: New(From Plans) Comment: CLIMATE i I / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5% 2.5% Winter Summer Degree Days Moisture Range FL,ST LUCIE_CO_INTL FL_VERO_BEACH_MUNI 2 39 90 70 75 299 58 Medium BLOCKS Number Name Area Volume 1 Blocki 2931 26379 I SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 Main 2931 26379 Yes 4 3 1 Yes Yes Yes FLOORS V. # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab-On-Grade Edge Insulatio Main 160.8 ft 0 1593 ftz ---- 0 0 1 ROOF Roof Gable Roof Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color i Absor. Tested Tested Insul. (deg) 1 Hip Metal 1782 ft2 0 ft2 Unfinishe 0.35 No 0.4 No 20 26.6 ATTIC V # Type Ventilation Vent Ratio(1 in) Area RBS IRCC 1 Full attic Unvented 0 1593 ft2 N N I CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic(Unvented) Main 0 Blown 1593 ft2 0 Wood I i I I 4/12/2017 1:33 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 4 I 6 FORM R405-2014 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below SpaceR-Vahle FtArenR-Valup Frartion _ 1 N Exterior Concrete Block-Int Insul Main 4.09999 36 8 9 330.0 ft2 0 0.75 0 2 E Exterior Concrete Block-Int Insul Main 4.09999 38 9 342.0 ft2 0 0.75 0 I 3 S Exterior Concrete Block-Int Insul Main 4.09999 36 8 9 330.0 ft2 0 0.75 0 4 W Exterior Concrete Block-Int Insul Main 4.09999 38 9 342.0 ft2 0 0.75 0 5 N Exterior Concrete Block-Int Insul Main 4.09999 12 9 108.0 ft2 0 0.75 0 _ 6 N Garage Frame-Wood Main 13 24 9 216.0 ft2 0 0.7;5 0 _ 7 E Exterior Concrete Block-Int Insul Main 4.09999 44 9 396.0 ft2 0 0.75 0 8 S Exterior Concrete Block-Int Insul Main 4.09999 36 8 9 330.0 ft2 0 0.75 0 _ 9 W Exterior Concrete Block-Int Insul Main 4.09999 38 9 342.0 ft2 0 0.75 0 10 W Exterior Concrete Block-Int Insul Main 4.09999 6 9 54.0 ft2 0 0.75 0 DOORS j # Omt Door Type Space Storms U-Value Width Height j Area Ft In Ft In 1 N Insulated Main None .4 3 6 8 20 ft2 I WINDOWS Orientation shown is the entered,Proposed orientation. Wall Overhang v # Omt ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 N 1 Vinyl Low-E Double Yes 0.33 0.22 6.9 ft2 2 ft 0 in 1 ft 0 in None None 2 E 2 Vinyl Low-E Double Yes 0.33 0.22 29.3 ft2 2 ft 0 in 1 ft 0 in None None 3 S 3 Vinyl Low-E Double Yes 0.33 0.22 48.6 ft2 2 ft 0 in 1 ft 0 in None None 4 W 4 Vinyl Low-E Double Yes 0.33 0.22 13.4 ft2 2 ft 0 in 1 ft 0 in None None 5 E 7 Vinyl Low-E Double Yes 0.33 0.22 64.8 ft2 8 ft 0 in 1 ft 0 in None None 6 E 7 Vinyl Low-E Double Yes 0.33 0.22 48.0 ft2 8 ft 0 in 1 ft 0 in None None 7 W 9 Vinyl Low-E Double Yes 0.33 0.22 18.4 ft2 10 ft 0 in 1 ft 0 in None None 8 W 9 Vinyl Low-E Double Yes 0.33 0.22 48.0 ft2 10 ft 0 in 1 ft 0 in None None 9 W 9 Vinyl Low-E Double Yes 0.33 0.22 16.2 ft2 10 ft 0 in 1 ft 0 in None None 10 W 10 Vinyl Low-E Double Yes 0.33 0.22 16.2 ft2 2 ft 0 in 1 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg.Wall Height Exposed Wall Insulation 1 672 ft2 384 ft2 92 ft 9 ft 1 INFILTRATION I I # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH*) .000286 2198.3 120.68 226.96 .264 5 w � 7 4/12/2017 1:33 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 4 FORM R405-2014 j HEATING SYSTEM # System Type '; Subtype Efficiency Capacity Block f Ducts 1 A Electric Strip Heat 1 None COP:1 16 kBtu/hr 1 sys#1 1 B Electric Strip Heat None COP:1 16 kBtu/hr 1 sy5#1 i COOLING SYSTEM # System Type j Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 A Central Unit None SEER:16 18 kBtu/hr 540 cfm 0.75 1 { sys#1 i 1 B Central Unit None SEER:16 24 kBtu/hr 720 cfm 0.75 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Propane Tankless Main 0.59 1 gal 60 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model# Collector Model# Area Volume FEF None None E ftz DUCTS —Supply—; —Return— Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 A attic 6 150 f12 attic 50 ftz Default Leakage main (Default) (Default) 1 1 1 B Main 6 200 f12 Main 100 ftz Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: None Ceiling Fans: CoolingJan � ]]Feb Mar ( �Apr May [X]Jun rj Jul rl 'Au X Se Oct Nov ]Dec Heatin Jan [X]Feb Mar j ]pr . May i ]Jun Jul Au4 Sep j Oct Nov [X]Dec Vent Jan [[ ]]Feb X Mar [X]A r [ Ma [ ]Jun Jul Aug [ Se [xl Oct X Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling(WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating(WEH) AM 68 68 68 68 68 68 68 68 68 68 68, 68 PM 68 68 68 68 68 68 68 68 68 68 68 ' 68 I I i I I' 411 2/201 7 1:33 PM EnergyGauge®USA-FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 4 FORM R405-2014 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 89 The lower the EnergyPerformance Index, the more efficient the home. 2275 BROCKSMITH RD, FORT PIERCE, FL, 1. New construction or existing New(From Plans) 9. Wall Types Insulation Area 2. Single family or multiple family Single-family a.Concrete Block-Int Insul,Exterior R=4.1 2574.00 ft2 b.Frame-Wood,Adjacent R=13.0 216.00 ft2 3. Number of units,if multiple family 1 c.N/A R= ft2 4. Number of Bedrooms 3 d.WA R= ftZ 5. Is this a worst case? No 10.Ceiling Types Insulation Area a.Roof Deck(Unvented) R=20.0 1593.00 ft2 6. Conditioned floor area(ft2) 2931 b.N/A R= ft2 7. Windows" Description Area c.N/A R= ft2 11.Ducts R ! ft2 a. U-Factor: Dbl,U=0.33 309.60 ft2 a.Sup:Main,Ret:Main,AH:Main 6 �200 SHGC: SHGC=0.22 b. U-Factor: N/A ft2 SHGC: 12.Cooling systems kBtu/hr Efficiency c. U-Factor: N/A ft2 a.Central Unit 42.0 SEER:16.00 SHGC: 1 d. U-Factor: N/A ft2 13.Heating systems kBtu/hr Efficiency SHGC: a.Electric Strip Heat 32.0 COP:1.00 Area Weighted Average Overhang Depth: 6.319 ft. Area Weighted Average SHGC: 0.220 8. Floor Types Insulation Area 14.Hot water systems Ca 1 gallons a.Slab-On-Grade Edge Insulation R=0.0 1593.00 ft2 a.Propane p' EF:0.59 b.N/A R= ft2 c.N/A R= ft2 b. Conservation features None 15.Credits CF ! ! I certify that this home has complied with the Florida Energy Efficiency Code for Building O�T$E STATt� Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed ,,,r =€ based on installed Code compliant features. ,Z',, Builder Signature: Date: -' IZ - Address of New Home: 02�� lGs n�,�1 L, 2 City/FL Zip: �� � 3�rSYS r4 �5`� i "Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at(321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. f **Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. 4/12/2017 1:34 PM EnergyGauge®USA-FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1 ! �I I i- Job: 'writ htsoft Project:Summary Date: Apr 11,2ot7 9 UNIT ONE By: DI IFRANCESCO I Proirect Information For. j NEWMAN RESIDENCE 2275 BROCKSMITH RD, FORT PIERCE,FL Notes: Design Infor • i Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 °F Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 0 Btuh Structure 12652 Btuh Ducts 0 Btuh Ducts 2101 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) Humidification 0 Btuh Blower 2048 Btuh Piping 0 Stuh Equipment load 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 15961 Btuh. Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 2 (Average) Structure 2408 Btuh Ducts 1801 Btuh Central vent(0 cfm) 0 Btuh Heatingg Cooling (none) Area(ftz) D 1542 Equipment latent load 4209 Btuh Volume(ft3) 0 13817 Air changes/hour 0 0.21 Equipment total load 20170 Btuh Equiv.AVF(cfm) 0 48 Req. total capacity at 0.70 SHR 1.9 ton Heating Equipment Summary Cooling Equipment Summary j Make Make Trane Trade Trade TRANE Model Cond 4TTR4025L1 AHRI ref Coil `AM7AOB30H21 AHRI ref 7548208 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 0 kW Sensible cooling 16800 Btuh Heating output 0 Btuh Latent cooling 7200 Btuh ; Temperature rise 0 OF Total cooling 24000 Btuh Actual airflow 800 cfm Actual air flow 800 'cfm Air flow factor 0 cfm/Btuh Air flow factor 0.054 'cfm/B uh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.80 I i Calculations approved byACCA to meet all requirements of Manual J 8th Ed. Wrii httoit 2017-Apr-1214;a'" 9 Right Sutte®UNversal 201717A.17 RSU06570 Page 1 JATransfer\Manual JINEWMAN RESIDENCE-2.rup Cale=MJS Front Door faces: E Job: L ry htsoft� Project Summary Date: Apr 11,2017 w 9 UNIT TWO By: DI FRANCESCO For. 'I NEWMAN RESIDENCE 2275 BROCKSMITH RD, FORT PIERCE, FL Notes: I Design Information. Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/Ib Heating Summary Sensible Cooling Equipment Load Sizing Structure 0 Btuh Structure 9337 Btuh Ducts 0 Btuh Ducts 1601 Btuh Central vent(0 cfm) 0 Btuh Central vent(0 cfm) 0 Btuh (none) Humidification 0 Btuh Blower 1707 Btuh Piping 0 Btuh Equipment load 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 12012 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 2 (Average) Structure 2259 Btuh Ducts 1341 Btuh Central vent(0 cfm) 0 Btuh ' Heating Cooling (none) Area(ft2) 0 1404 Equipment latent load 3600 Btuh Volume (ft3) 0 12636 Air charges/hour 0 0.21 Equipment total load 15612 Btuh Equiv.AVF(cfm) 0 45 Req. total capacity at 0.70 SHR 1.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade XR15 Model Cond 4TTR5018E1 AHRI ref Coil *AM7AOA24H21 AHRI ref 4385349 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 0 kW Sensible cooling 12390 Btuh Heating output 0 Btuh Latent cooling 5310 ;Btuh Temperature rise 0 °F Total cooling 17700 �Btuh Actual air flow 590 cfm Actual air flow 590 ;cfm Air flow factor 0 cfm/Btuh Air flow factor 0.054 cfm/B uh Static pressure 0 in H2O Static pressure 0.10 in H2O Space thermostat Load sensible heat ratio 0.78 I � Calculations approved byACCAto meet all requirements of Manual J 8th Ed. -F�+ wr➢ghtsoft" Rlght-suftes universal 201717.0.17 RSu06570 2017-Apr-1214:age 2 p i Page 2 ,4M inransferwanual JINEWMAN RESIDENCE-2.rup Cale=MJ8 Front Door faces: E i I - -wrightsoW RI ht-J®Worksheet o�; pprlf,ao�� UNIT ONE By: DI FMNCESCO 1 Room name UNIT ONE kitchen 2 Exposed wall 162.0 ft 28.0 ft 3 Room height 9.0 ft 9.0 ft cool only 4 Room dimensions 12.0 x 16.0 ft 5 Room area 1542.0 ft' 192 0 ft2 Ty Construction U-value Or HTM Area (ft) Load Area (ft-) Load (Btuhfftz-°F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 w 12C4)sw 0.091 n 0.00 1.96 187 187 0 365 0 0 0 0 1RJ 13A 4ocs a143 n 0.00 219 138 117 0 255 0 0 0 0 4A5r2ov Q470 n 0.00 0.00 0 0 0 0 0 0 0 0 11130 0.290 n 0.00 7.68 21 21 0 161 0 0 0 0 11 vLiMAWS 0.143 a 0.00 219 405 297 0 650 0 0 0 0 10D-4' 0.490 e. 0.00 28.67 48, 0 0 1280 0 0 0 0 4A5-2ov 0.470. .e . 0.0D 36.84 W 0 0 2210 0 0 0 0 13A4ocs 0.143 s 0.00 219 324 324 0 709 144 144 0 315 Y-G 05-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 VP 13A4ocs 0 143 ,w 0.00 219 405 318 0 696 108 96 0 210 4A5.2ov 0 470 w 0.00 36.84 24 0 0 884 12 0' 0 442 4A5-26v 0.470 w 0.00 13.55. 15 15 0. 2D3 0 0 0 0 4AS2ovd ! 0.470: W 0.00: 15.59 -48 44 a 748 0 0 0 0 C 16X19-0rnd 0.408 - 0.00 1.37 138 138 0 189 0 0 0 0 F 22Gbtpl 0.9w = O.OD 0.00 1542 162 0 0 192 28 0 0 i i i i i i I i I 6 c)AEDeocursion 149 -301 Envelope loss/gain 0 8500 0 666 12 a) Infiltration 0 793 0 137 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliances/other 2900 200D Subtotal(lines 6 to 13) ( 0 12652 0 2803 Less external load Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 12652 0 2803 15 Duct loads 0% 17% 0 2101 0% 17% 0 465 Total room load Air required(cfm) 0 14753 0 32681 01 800 0 177 Calculations approved bvACCAto meet all requirements of Manual J 8th Ed wrightSOft RghtSuite®Universal 2017 17.0.17 RSU08570 2o17-Apr-12 94:24:40 �CGA J:\TranderlManual ANEWMAN RESIDENCE-2.rup Cale=MJ8 Front Door faces: E Page 1 i i f i - -wrightsoft' Right-JO Worksheet Job: Bate: Apr 11,2017 UNIT ONE I By: 61 FRMCESCO 1 Room name dining great no 2 Exposed wall 10.0 ft 45.0 ft 3 Room height 9.0 ft cool only 9.0 ft cool only 4 Room dimensions 10.0 x 16.0 It 1.0 x 462.0 ft 5 Room area j 160.0 ft2 452.0 ft2 Ty Constriction 11 value Or HTM Area (ft2) Load Area (ft2) Load 1 number (Btuwit-F) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6'.W 12C-0sw I 0.091 n 0.00 1.96 0 0 0 0 0 01 0 0 1fN 13A-4ocs 0.143 n 0.00 Z19 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 11PO Q290 n 0.00 7.68 0 0 0 0 0 0 0 0 11 13A4ocs 0.143 a 0.00 219 0 0 0 . 0 - 225 147 0 322 10D-v 0.490 a 0.00 26.67, 0 0 0 0 48 0 0 1280 4A5-2ov 0.470. a 0.00 36.84 0 0 0 0 30 0 0 1105 t13A-4ocs 0.143 s 0.00 219 0 0 0 0 180 180 0 394 -G 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 h13A4ocs 0.143 w 0.00 219 90. 42 0 92 0 0 0 0 4AS2cv 0.470 w . O.OD 36.84 0 0 0 0 0 0 0 0 4AS26v 0.470 .w '0.00 13:55 0 0 0 0 0 0 0 0 .4A5-2ovd 0.470 vi 0.00 15.59 48 44 0 748 0 0 0 0 C 16X19-0md 0.408 - 0.00 1.37 0 0 0 0 0 0 0 0 F 2W.-W 0.Wo - 0.00- 0.00 160 10 0 0 452 45 0 0 I I i I I i i I i 6 c)AE D excursion 9D2 -407 Envelope loss/gain 0 1742 0 I 2694 12 a) Infiltration 0 49 0 220 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 900 Subtotal(lines 6 to 13) 0 1791 1 0 11 3814 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 1791 0 3814 15 Duct loads 0% 17% 0 297 0% 17% 0 633 Total room load 0 2089 0 4447 Air required(cfm) 0 113 0 241 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. - ' wrightsoft` 2017-Apr-12 4:24:40 RlghtSulte®Universal 2017 17.0.17 RSU06570 Page 2 J:%Transf hManual JINEWMAN RESIDENCE-2.rup Calc=MJ8 Front Door faces: E I 1 - -wrightsoft° M hW@ Worksheet Job: WT ONE Date: Apr 11,2017 By: DI'FRANCESCO 1 Room name pntry clt2 2 F)posed wall 5.0 ft 0 ft 3 Room height 9.0 ft cool only 9.0 ft cool only 4 Room dtsttensions 60 x 6.0 ft 50 x 60 ft 5 Room area 30.0 ftz 30.0 fN Ty I Construction U=value Or HTM Area (ft) Load Area (ft2) Load number (Btuhfftz-°F) (Btuhlftz) or perimeter (ft) (BM) or perimeter (ft) (Btuh) Heat Cool Gross N/p/s Heat Cool Gross N/P/S Heat Cool 6'W 12CAsw 0.091 h D.OD 1.96 0 0 0 0 0 0 0 0 yJ 13A4ocs 0.143 n 0.00 219 0 0 0 0 0 0 0 0 FL-_Cp 4AS-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 11po 0.290 n 0.00 7.68 0 0 0 0 0 0 D 0 11 13A flocs 0143 a 0.00 219 0 0 0 0 0 0 0 0 1013 v" 0.490 a 0.00 .26.67 0 0 0 0 0 0 0 0 4A5 2ov. 0.470, e 0.00. 36.84 0 0 0 0 0 0 0 0 y�► 13A.40cs 0.143 s 0.00 2-19 0 0 0 0 0 0 0 0 1-6 4A&2ov 0.470 s 0.00 0.000 0 0 0 0 0 0 0 13A�ocs 0.143 w 0.00 2-19 45 45 0 98 0 0 0 0 QA5-2ov 0 470 w 0.00 38.84 0 0 0 0 0 0 0 0 4Ar2ov. 0.470. w 0.00. 13.55 0 0 0 0 0 0 0 0 4A5.2ovd 0.470: vu 0:00 15.59 0 0 0 0 0 0 0: '0 C 16X19-0md 0.408 - 0.00 1.37 0 0 0 0 0 0 0 0 F 22C_tpt' 0.9w _ 0.00 0.00 30 5 0 0 30 0 0 0 i 6 c)AED ercursion 49 0 Envelope lossigain 0 79 0 I. 0 12 a) Infiltration 0 24 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @l; 230 0 0 0 0 Appliances/other 0 ` 0 Subtotal(limes 6 to 13) 0 104 0 0 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 104 0 0 15 Duct loads 00/0 17°/a 0 17 00/0 17% 0 0 Total room load 0 121 0 0 Air required(cfm) 0 71 0 0 Calculations appmved by ACCA to meet all requirements of Manual J 8th Ed. 4wrli htsoft" 2017-Apr-1214:24:40 --..r Q RightSuReS UnWersal 20l7 l7.0.17 RSU06570 bage 3 JATransfer\Manual JWEWMAN RESIDENCE-2.rup Cale=MJ8 Front Door faces: E i l I " f wrightsoft- Right- 6I Worksheet Job: 'UNIT ONE Date: Apr 11,20117 By: DIFRANCESCO I 1 Room name bedrrn 2 stairs 2 Exposed wall I 12.0 ft 0 ft 3 Room height 9.0 ft cool only 9.0 ft cool only 4 Room dimensions 12-0 x 12-0 ft 3.0 x 16A it 5 Room area 144.0 ft' 48.0 ft' Ty Construction U-value Or HTM Area (W) Load Area (" Load number (Btuh/fWF) (Btuhlf ) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I NIP/S Heat I Cool 6 w 12C4)sw 0.091' n 0.0D 1.96 0 0 0 0 0 0 0 0 13AAocs 0.143 n 0.00 219 0 0 0 0 0 0 0 0 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 n 0.00 7.68 0 0 0 0 0 0 O j 0 11 lak4ocs 0.143 a 0.00 219 0 0 0 0 0 0 0 0 -G 10D�.v 0.490 'e 0.00. 28.67 0 0 0 0 0 0 0 0 �--G 4A5.2ov OAM is -0.00 36.84 0 0 0 0 0 0 0 0 V,v 13AAocs 0.143 's 0.00 219 0 0 0 0 0 0 0 0 L_ G 4A5.2ov OAM s 0.00 0.00 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w O OD 219 10B 93' 0 203 0 0 0 0 4A5-2oy. 0AM w 040 36.84 0 0 0 0 0 0 0 0 4A5-2ov. 0.470 w 0.00 1155 15 15 0 2D3 0 0 0 0 4A5-2ovd 0.470 w 0.00 15.59 0 0 0 0 0 0 0 0 C 16X190nd 0.408 - 0.00 1.37 0 0 0 0 0 0 0 0 F 22C..61pl 0.9w: - 0.00 0.00 144 12 0 0 48 0 0 0 I it 6 c)AEDercursion 217 0 Envelope loss/gain 0 624 0 1 0 12 a) Infiltration 0 59 0 I 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Applianoe dBwr 0 I .0 Subtotal(lines 6 to 13) 0 913 0 0 Less external load I 0 0 0 0 Less transfer 1 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 913 0 0 151 Duct loads 0% 17% 0 152 00/0 17°h 0 0 Total room load 0 1064 0 0 Air required(cfm) 0 58 0 0 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wri htsOft` 2017 Apr-12 14:24:40 9 Rlght-Sulte®Universal 2017 17.0.17 RSUOM70 Page 4 R+JATranuarlManual JINEWAAAN RESIDENCE-2.rup Colo=MJ8 Front Door faces: E I I - Wrightsoft° Right-M Worksheet Job: UNIT ONE Date: Apr 11,2017 DI FRANCESCO By: 1 Room name bath 2 wic 3 . 2 Evosed wall 0 ft O ft 3 Room height 9.0 ft cool only 9.0 ft cool only 4 Room dimensions 8.0 x TA ft 6.0 x 7.0 1t 5 Room area 56.0 ft2 420 ft2 Ty I Construction ',U-value or HTM Area (W) Load Area (ft2) Load (Bt 2L'F) (Btutrlft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/PIS Heat Coal Gross NIPIS Heat 'Cool 6.'.W 120-0sw j 0.091 i n 0.00 1.96 0 0 0 0 0 0 0 0 V�f 13A4ocs 0.143 n 0.00 219 0 0 0 0 0 0 0 0 ;L-OG 4A5.2ov 0.470 n 0.00 0.00 0 0 0 0 0 0 0 0 11P0 0.290 n 0.00 7.68 0 0 0 0 0 0 0 0 11 'V 13AAoos 0.143 ,a 0.00 219 0 0 0 0 0 0 0 0 10D-v 0.490 a 0.00 26.67 0 . 0 0 0 0 0 0 0 ',5- v 0.470 -e 0.00 36.84 0 0 0 0 0 0 0 0 V,U 13A-4ocs 0.143 s 0.00 2-19 0 0 0 0 0 0 0 0 L-G 4A5-2ov 0.470 s 0.00 0.00 0 0 0 0 0 0 0 0 J3A1racs 0.143 w 0.00 21s 0 0 0 0 0 0 0 0 AS-2ov M470 w 0.00 36.84 0 0 0 0 0 0 0 0 A5.2cv: a470 w 0.00 13.55 0 0 0 0 0 0 0 0 A5-2ovd 0.470 W 0.00 15.59 0 0 0 0 0 0 0 0 C 16XISAMW 0.408 - 0.00 1.37 0 0 0 0 0 0 0 0 F 22Cao 0.980 - 0.00 0.00 56 0 0 0 42 0 0 0 f i i i i i I 6 c)AEDex:ursion 0 0 Envelope lossfgain 0 0 0 1� 0 12 a) Infiltration 0 0 0 ` 0 b) Room ventilation 0 0 0 0 13 internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 0 0 0 ` 0 Less external load 0 0 0 0 Low transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 0 0 0 15 Duct loads 0% 17% 0 0 0% 17% 0 0 Total roam load 0 0 0 0 Air required(oftn) j 0 0 0 I 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed.R�ghtSuite®Universal 2017 17.0.17 RSU08570 wrightsoft" 2017-Apr-1214:24:40 J:1TlransferlManual JINEWMAN RESIDENCE-,2sup Calc=MJ8 Front Door faces: E Page 5 i i -wrightsofta Ri hl Worksheet Job: IT •ONE Date: Apr 11,2Q1 T By: DIFRANCESCO 1 Room name bedrm 3 h 2 Exposed wall 27.0 ft 0 ft 3 Room height 9.0 ft cool only 8.1 ft cool only 4 Rmmd%mewAans 14A x 13A K 17A x 4.0 tt 5 Room area 182.0 ft2 68.0 ft' Ty I Construction 6-value Or HTM Area (ft�) Load Area (7) Load number (Btuh/ft'-°F) (Bt wff) or perimeter (ft) (Stuh) or perimeter (ft) (Btuh)i Heat cool Gross NIPIS Heat Cool Gross NIP/S Heat 6001 6 .W 12C-06w 0.091 n 0.00 1.96 0 0 0 0 0 0 0 0 IRJ 13A-4ocs 0.143 n 0.OD 219 117 117 0 256 0 0 0 0 4AS-2av 0.470 n O.OD O.W 0 0 0 0 0 0 0 0 11p0 0.290 n 0.00 7.68 0 0 0 0 0 0 0 0 11 13A-4ocs 0.143 a 0.00 . 219 125 96 0 210 0 0 0 --G 100-V Q490 a 0.00 28.67 0 0 0 0 0 0 0 I 0 L—G 4A5-2ov 0.470 a O.OD 36.84 30 0 0 1105 0 0 0 0 V►J 13AAws, 0.143 s 0.00 219 0 0 0 0 0 0 0 0 l--Ci 4A5-2ov 0.470 a 0.0D 0.00 0 0 0 0 0 0 0 0 13A-4ocs 0.143 w O.W 219 0 0 0 0 0 0 0 D 4A5-2ov 0.470 w. O.W 38.84 0 0 0 0 0 0 0 0 4A5-2ov 0.470 w OW 13.55 0 0 0 0 0 0 0 I 0 4A'r2avd 0.470 w 0.00 15.59 0 0 0 0 0 0 0 0 C 16X19-0md 0.408 - 0.00 1.37 0 0 0 0 0 0 .0 0 F 22Cftpl 0.980 0.00 0.00 182 27 0 0 68 0 0 0 j l I I I I I 1 6 c)AEDemrsion -185 j 0 Fsvelope loss/gain 0 1387 O 0 12 a) Infiltration 0 132 0 0 b) Room ventilation 0 0 0 I 0 13 1ntemal gains: Occupants @, 230 1 230 0 I 0 Appliances/other 0 0 Subtotal(lines 6 to 13) I 0 1749 0 0 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 0 1749 0 0 15 Duct loads 00/0 17%1 0 290 0% 17% 0 0 Total room load 0 2039 0 0 Air required(tiro) 0 111 0 ` 0 I . Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. �^11.• writ httsoft� 2017-Apr-1214:24:40 � -'f r 9 Right-Sulte®Universal 201717.0.17 RSU06570 Page 6 -4&CK J:\TransferlManual J\NEWMAN RESIDENCE-.2.rup Calc=MJ8 Front Door faces: E i - I I i wrightsoft& Right-J®Worksheet Job: UNIT ONE Date: Apr11,2017 By: DIFRANCESCO 1 Room name laundry 2 =ed wall 35.0 ft 3 Room height 9.0 ft cool only 4 Room dimensions 6.0 x 23.0 ft 5 Room area 13B.0 ft2 Ty I Construction 'U value Or HTM Area (ftz) Load Area Load number (Btuh/ftmF) (Btuh/ftz) or perimeter (ft) (Btuh) or perimeter f I Heat Cool Gross NIPIS Heat Cool Gross NIPIS Heat ICcol i 8'W 12C-0sw 0.091 n 0.00 1.96 167 197 0 365 Vpl 13A-4ocs 0.143 n 0.00 2.19 21 -1 0 -1 (L-----GD 4A5-2ov 0.470 n 0.00 0.00 0 0 0 0 11P0 0.290 n 0.00 7.68 21 21 0 161 11 W, , 13A4ocs 0143 e _ 0.M 2.19 54 54 0 118 -G 10D�v 0.490 a 0:00 26.67. 0 0 0 0 L---G 4P5-2ov 0:470 a 0.0- 36.84 0 0 0 0 1I,U 13A-4ocs 0.143 s 0.00 2.19 0 0 0 0 t-G 4A5 2ov 0.470 s 0.00 0.00 0 0 0 0 13A4ocs 0.143 iv 0.00 2.19 54 42 0 92 4A5-2ov 0.470 w 0.00 36.84 12 0 0 442 _4P&2ov 0.470 w 0.00 13.55 0 0 0 0 4A5-2ovd 0.470" vv 0.00 ISM 0 0 0 0 C 16X19-0md 0.408 - 0.00 1.37 138 138 0 189 f =C-6tpi 0.980 = 0:00 0.00 138 35 0 0 I 6 c)AED evursion Envelope loselgain 0 1308 12 a) Infiltration 0 171 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 0 Subtotal(lines 6 to 13) 4 0 1479 Less wdemal load 0 0 Less transfer 0 0 Redistribution 0 0 14 Subtotal 0 1479 151 Duct loads ov. 170A 0 246 Total room load 0 1725 Air required(cfm) 0 94 Calculations approved byACCAto meet all requirements of Manual J Sth Ed. .y wri htsofV 2017-Apr-1214:24:40 9 RightSuite(D Universal 2017 17.0.17 RSLMS570 I{I Page 7 JATraW. Manual JWEWMAN RESIDENCE-2.rup Cale=MJ8 Front Door faces: E -��-wrightsoft° Right-JO Worksheet Job: UNIT TWO Date: Apr 11,2017 By: DI FRANCESCO 1 Room name I UNIT 1WO MISTR BEDRM 2 Exposed wall 150.0 ft 45.0 ft 3 Room height 9.0 ft 9.0 ft coolllonly 4 Room dimensions 1.0 x 476.0ft 5 Room area 1404.0 ft' 476.0 IF Ty Construction U value Or HTM Area (ftz) Load Area Load number (Btuh/ft;-'F) (Btuh/ft') or perimeter (ft) (Btuh) or perimeter (ft) (Blob) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat j Cool 6,W 12C-0sw 0:091 n 0.00 0.00 0 0 0 0 0 0 0 0 1�J 13A4ocs 0.143 n 0.00 219 324 312 0 683 0 0 0 0 4A5-2ov 0.470 n 0.00 13.55 12 0 0 163 0 0 0 0 t--D 11130 0.290 n 0.00 0.00 0 0 0 0 0 0 0 0 11 13A4ocs 0.143 a 0.00 Z19 351 315 0 689 0 0 0 'j 0 %-G' 10Dir 0.490 a 0.00 0.00• 0 0 0 0 0 0 0 0 05-2ov 0.470 a. 0.00 36.84 36 0 0 1326 0 0 0 0 IN 13A-4ocs 0.143 s 0.00 219 324 279 0 610 180 150 0 328 I--C 4A5.2ov 0.470 a 0.00 14.83 45 0 0 667 30 0 0 445 13A-Rocs 0.143 w 0:00 219 351 339 0 742 225 213 0 465 4A5-20v 0.470 w . 0.00 36.84 12• 0 0 442 12 0 0 442 4A5-2ov 0.470 w- 0.00 0.00 0 0 0 0 0 0 0 0 4AS-2orvd 0.470 w 0.00 0.00 0 0 0 0 0 0 0 1 0 C 16X19-0md 0.408 - 0.00 1.37 1404 1404 0 1921 476 476 0 ; 651 F 22C-W 0.980 = 0.00 0.00 0 0 0 0 0 0 0 0 I I I I I i i I I i i 6 c)AED wcursion 0 47 Envelope loss/gain 0 7243 0 2379 12 a) Infittratlon 0 734 0 22D b) Room ventilation 0 0 0 0 13 Intemal gains: Occupants @ 230 2 460 2 460 Appliances/other 900 0 Subtotal(limes 6 to 13) 0 9337 0 III 3059 Less wdemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 13 [14 SuMotal 0 9337 0 3072 Duct loads 0% 17% 0 1601 00/0 170A 0 527 Total room load 0 Iowa 0 3599 Air required(cfm) 0 5901 1 0 194 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. wrightsoTt' 2o17-Apr-1214:24:40 Right-Sufte�Universal 201717.0.17 RS1106570 I JATr r\M ansfeanual ANEWMAN RESIDENCE-2.rup Cate=MJ8 Front Door faces: E Page 8 i I Job -V wrightsofta Ri ht-M Worksheet Date i JSIT TWO Date: Apr 11,2017 By: DI FRMCESCO 1 Room name I OFFICE STR2 2 Exposed wall 30.0 ft 0 ft 3 Room helgM I 9.0 ft cool only 9.0 ft cool only 4 Room dmetvsions 14.0 x 16.0 ft 3.0 x 16.0 ft I 5 Room area 224.0 ft2 48.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BtuhlfV-°F) (BWft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I N/P/S Heat 1 Cool 6:W 12C-0sw 0.aM n 0:00 0.00 0 0 0 0 0 0 0 0 13A400s 0.143 n 0.00 2.19 0 0 0 0 0 0 O I 0 4A5.2ov 0.470 n 0.00 13.55 0 0 0 0 0 0 0 1 0 11P0 0.290 n 0.00 0.00 0 0 0 0 0 0 0 0 11 yJ 13A-4ocs 0.143 a 0.00 219 128 114 0 249 0 0 0 0 It--GG 10D,v. 0.490 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470. a 0.00 36.84 12 0 0 442 0 0 0 0 V�! 13A-4ocs 0.143 s 0.00 2.19 144 129 0 282 0 0 0 0 --G 4A5-2ov 0.470 s 0.00 14.83 15 0 0 222 0 0 0 0 13A=4ocs 0.143 is 0.00 2.19 0 0 0 0 0 0 0 0 �1f--G 4Ar2ov 0.470. vo 0.00 36.84 a 0 0 0 0 0 0 0 1=-G 4A5-2ov. 0.470 w 0.00 a00 0 0 0 0 0 0 0 0 4A5-2ovd 0.470. w 0.00 0.00 0 .0 0 0 0 0 0 I 0 C 16X19-0md 0.408 - 0.00 1.37 224 224 0 306 48 48 0 66 F 220-51pl 0.980 - 0.00 0.00 0 0 0 0 0 0 0 1 0 I I I I I I I 6 c)AEDecursion -41 -1 Envelope lossigain 0 1462 0 65 12 a) Infiltration 0 147 0 0 b) Room ventilation 0 0 0 0 13 1rdemal gains: Occupanfs @ 230 0 0 0 0 Appliances/odwr 900 0 Subtotal(lines 6 to 13) 0 2509 0 I 65 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 -65 14 Subtotal 0 25M 0 0 151 Duct loads 00/0 17% 0 430 0% 17% 0 0 Total room load 0 2839 0 0 Air required(cfrn) 0 159 01 0 Calculations approved byACCAto meet all requirements of Manual J Sth Ed. .� wriglittsotFt° 2017-Apr-1214:24:40 Rlght-Suite®Universal 201717.0.17 RSU06570 Pages JATransferlManual JWEWMAN RESIDENCE-2.rup Cale=MJ8 Front Door faces: E i i -wrightsoft Right-M Worksheet Joe: UNIT TWO Date: Apr 11,2017 I11 By: DIFRANCESCO 1 Room name MSTR WIC 1 MSTR WIC2 2 FVosed wall 23.0 ft 12.0 ft 3 Room height 9.0 ft cool only 9.0 ft cool only 4 Room cfimertsions 14.0 x 9.0 ft 6.0 x 12A ft I 5 Room area 125.0 ft2 60.0 ftZ Ty I Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BtuhlftvF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I N!P!S Heat Cool 6 W 12C Osw 0.091 n 0:00 0.00 0 0 0 0. 0 0 0 0 Val 13A4ocs 0.143 n 0.00 2-19 81 81 0 177 108 1� 0 236 4A5-2ov OAM n 0.00 13.55 0 0 0 0 0 0 0 0 11150 0.290 n 0.00 0.00 0 0 0 0 0 0 0 0 11 13A4ocs 0.143 e . 0.00 2-19 0 0 0 0 0 0 0 0 10Dw 0.490 a -0.00 0.00 0 0 . 0 0 0 0 0 0 4A5-2ov 0.470 a 0.00 36.84 0 0 0 0 0 0 0 0 Val 13A-4ocs 0.143 s 0.00 2.19 0 0 0 0 0 0 0 0 G 4A5.2ov 0.470 s 0.00 14.83 0 0 0 0 0 0 0 0 vh13A4ocs 0.143 w 0.00 Z19 128 126 0 276 0 0 0 0 4AS-2ov OAM w 0.00 36.84 0 0 0 0 0 0 0 0 4A5-2ov 0.470. w 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ovd OAM yr 0.00 0.00 0- 0 0 0 0 0 0 1 0 C 16X190nd 0.408 - 0.00 1.37 126 126 0 172 60 60 0 82 F 22C-BV 0.980 - 0.00 0.00 0 0 0 0 0 0 0 0 i I i I I i I 6 c)AED excursion -12 1 -6 Frnelope losafgain 0 614 0 j 312 12 a) Infiltration 0 113 0 59 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(limes 6 to 13) 0 726 0 371 Less odemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 18 0 24 14 Subtotal 0 744 0 395 15 Duct IN 0% 17% 0 128 00/0 17% 0 68 Total room load 0 872 0 463 Air required(cfm) 0 47 1 1 0 25 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. wri htsoft° 2017-Apr-1214:24:40 9 Right-Suite®Universal 2017 17.0A7 RSUD6570 Page 10 .9C A J:\Transfer\Manual ANEWMAN RESIDENCE-2.rup Calc=MJ8 Front Door faces: E i 1 - -wrightsoft° Right-J®Worksheet Job: UNIT TWO Date: Apr 11,2017 DI FRANCESCO By. 1 Room name MSTR BATH STORAGE 2 Exposed wail 29.0 ft 0 ft 3 Room height 9.0 ft cool only 9.0 ft cool only 4 Room dimensions 14.0 x 16.0 ft 1.0 x 57.0 ft 5 Room area 210.0 ft2 57.0 fY Ty I Construction U-value Or HTM Area (ft2) load Area (W) Load number (Btuh/ft-F) (ft"" or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross I N/P/S Heat I Cool 6 W 12C-0sw ! 0.091 ;n 0.00 0.00 0 0 0 0 0 0. 0 0 1/t!! 13A-4ocs 0.143 n 0.00 2.19 135 123 0 259 0 0 0 0 tl-----GD 4A5-2ov 0.470 n 0.00 13.55 12 0 0 163 0 0 0 0 1 11p0 0.290 n 0.00 0.00 0 0 0 0 0 0 0 0 11 VLI13A4ocs 0.143 a 0.00 2.19 128 114 0 249 0 0 0 0 10D=v 0.490 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2Dv 0.470 a 0.00 36.84 12 0 0 442 0 0 0 0 yJ 13A-4ocs 0.143 s 0.00 2.19 0 0 0 0 0 0 0 0 t-.G 4A5,2ov 0.470 s 0.00 14.83 0 0 0 0 0 0 0 0 1 At*Lj 13A4ocs 0.143 w 0.013 2.19 0 0 0 0 D 0 0 0 4A5-2Dv 0.470 w 0.00 36.84 0 0 0 0 0 0 0 0 4A5-2ov 0.470 W 0.00 0.00 0 0 0 0 0 0 0 0 4A54ovd 0.470 w 0.00. 0.00 0 O. 0 0 0 0 0 0 C 16X19-0md 0.408 - 0.00 1.37 210 210 0 287 57 57 0 78 F 22C-6tpl 0.9w O.OD 0.00 0 0 0 0 0 0 0 0 i 6 c)AED eoursion 25 ` -1 Envelope lossigain 0 1385 0 77 12 a) Infiltration 0 142 0 I 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) 0 1528 0 :1 77 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 27 0 42 14 Subtotal 0 1554 0 119 151 Duct loads 0%1 170/o 0 266 0% 17% 0 20 Total room load 0 1821 1 1 0 139 Air required(fin) 0 98 0 7 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 4*wriightsoft` Rlght-SuitedD Universal 201717.0.17 RSU06570 2017 Apr-12 14:Paggee 11 11 J.,MansfeAManual JWEWMAN RESIDENCE-,2.nrp Cale=MJ8 Front Door faces E I f • Job: 4-wrightsoft° Right-J®Worksheet UNIT.TUVO Date: Apr11,2017 61 FRMCESCO By: 1 Room name LANDING MH 2 Exposed wall 11.0 ft O ft 3 Room helght 9.0 ft cool only 9.0 ft cod only 4 Room dimensions 1.0 x 140.0 ft 1.0 x 63.0 ft 5 Room area I 140.0 ft2 63.0 W Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (BtuhtWF) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (13tuh)' Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat I Cool 6 W 12C-0sw 0.091 n 0.00 0.00 0 0 0 0 0 0 0 0 yU 13A-4acs 0.143 n 0.00 Me 0 0 0 0 0 0 0 0 I�---GD 4A&2ov 0.470 n 0.OD 13.55 0 0 0 0 0 0 0 0 11 PO 0.290 n 0.00 0.00 0 0 0 0 0 0 0 0 11 13A-Rocs 0.1.43 a 0.00 219 99 87. 0 190 0 0 0 0 10D-v 0.490 a 0.00 0.00 0 0 0 0 0 0 0 0 4A5-2ov 0.470 a 0.00 36.84 12 0 0 442 0 0 0 0 U,V 13A-4ocs 0.143 s 0.00 219 0 0 0 0 0 0 0 0 L.-G 4A5.2ov 0.470 a 0.00 14.83 0 0 0 0 0 0 0 0 13A4oas 0.143 w 0.00 219 0 0 0 0 0 . 0 0 0 4A526v 0.470 vi 000 36.84 0 0 0 0 0 0 0 0 4A5-2ov_ i 0.470 w 0.00 0.00 0 0 0 0 0 0 0 0 41 Zovd 0.470 w 0.00. 0.00 0 0 0 0 0 0 0 0 C 16X19-Cnd 0.408 - 0.00 1.37 140 140 0 192 63 63 0 86 F -=-s p( 0.8m 0.00 0.00 0 0 0 0 0 0 0 0 i i i I i ; 6 c)AE D wcursion 40 I -1 Envelope loss/gain 0 864 0 I 85 12 a) Infiltration 0 54 0 0 b) Room ventllation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6 to 13) I 0 918 0 85 Less eAemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 28 0 -85 14 Subtotal 0 943 0 0 15 Duct loads1 0% 17% 0 162 0% 171/16 0 0 Total room load 0 1105 0 0 Air required(cfm) 0 601 01. I 0 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. - - wrightsoft- 2017-Apr-12 14:24:40 Rlght-Suite®Unhrersal 2017 17.0.17 RSUM570 Page 12 O JATransferlManual ANEWMAN RESIDENCE-2.rup Calc-MJ8 Front Door faces: E i I ' N i Sheet 1 ptry $x4 ------------ °7 cfm 10 x 6 bedrm 2 113 cfm 42 x 12 Kitchen dining 4 j 10 x 10 clt2 ` 177 cfm Ne 10 x 6 f sundry: $'l 6 18x1:8' 3 i x;8 't h I 94 cfm CR 12 . �1 r 4 �„ 114 8" I I bath 2 _ wic 3 tit , .12 t 10 x 10 14 0800 cfm 121 cfm. - i Stairs 111OX6 great rrr, 6„ I 111 cfm 611 12)berm 3 II 121 cfm (� t�`i•1 ,8 i Job#: DI FRANCESCO Scale: 1 : 79 Performed for: Pagel NEWMAN RESIDENCE Right-Suite®Universal 2017 2275 BROCKSMITH RD 17.0.17 RSU06570 FORT P1ERC E,FL 2017-Apr-12 14:24:52 ...anual ANEWMANRESIDENCE-2.r... I; i i N I SECOND FLOOR MSTR WIC 1 , 8x4 Cr 47 cfm MSTR BEDRM j 4„ TORAGE i g MH 711 i STR WIC2 4 i�12x8 194 cfm '10° 8 x 4 i „ 8x4 6 25cfm 7cm o12x12' 110x6 98 cfm 711 STR2 1016 60 m OFF ICE 12x8 LANDING MSTR BATH 159 cfm I Job#: DI FRANCESCO Scale: 1 : 79` Performed for: NEWMAN RESIDENCE Righ Suite@ Universal tersal 2017 2275 BROCKSMITH RD 17.0.17 RSU065�`0 FORT P IERC E,FL 2017-Apr-1214:24t52 anual ANEWMAN RESIDENCE-2.r... I j N 5 Pvwyn rr � t7 oq ` 0 -7 7 i Sheet 1 r ntry 8x4 10 x 6 7 cfm R/A bedrm 2 kitcher dining 113 cfm 'y 12 x 12 4 10 x 10 clt� 4 177 cfm �6 10x6 laundry 8 6 8x18 6„ 6" 12x18 h y 94'cfm I ` 4" 4" 14" 8, 8 x 4 8 x 4 bath 2 _ �4 is : 12" 10 x 10 800 cfm; 121 cfm stairs 10x6 great r 6„ I 111 cfm 6" �12 x 12 bedrm I R/A 10x 10 [9.. 121cfm 18x18 R/A®-- RECEI D Jii?-) 0 7 2017 Job#: DI FRANCESCO Scale: 1 : 76 Performed for: Page 1 NEWMAN RESIDENCE Right-Suite®Universal 2017 2275 BROCKSMITH RD FORT PIERCE,FL 17.0.17 RSU06570 2017-Jun-01 07i55:28 ...anual JWEWMAN RESIDENCE I y I I I N I SECOND FLOOR i i MSTR WIC ' � I 8x4 47 cfm MSTR BEDRN R/A 4" fm 9" MH MSTR WIC 8" STORAGE 4" 12x8 4 8x4 194 cfm 10" /8.4 6" 25 cfm 7 m 12x12 10x6 RSA 98 cfm 5 STR2 7 10 6 0 fm OFFICE LANDING MSTR BATE 12x8 159 cfm i i I Job ; DI FRANCESCO Scale: 1 : 76 Performed for: Page 2 NEW2275 RESIDENCE Right-Suite(g)Uni�Isal 2017 275 BRO BROCKSMITH RD FORT PIERCE,F 17.0.17 RSU06570 L 2017-Jun-01 07:155:28 ...anual JWEVWM RESIDENCE I 1 Duct System SummaryJob: - - wrightsoft' YDate: Apr 11,2017 UNIT ONE By: DI FRANCESCO Project I • • For: NEWMAN RESIDENCE 2275 BROCKSMITH RD, FORT PIERCE, FL i I Heating Cooling External static pressure 0 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0.10 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.050/0.050 in H2O Lowest friction rate 0 in/100ft 0.028 in/100ft Actual air flow 800 cfm 800 cfm j Total effective length(TEL) 361 ft SupplyDetail Table I Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (Cfm) (Cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk bath 2 c 0 0 0 0.028 4.0 Ox 0 VIFx 16.0 345.0 st3 bedrm 2 c 1064 0 58 0.037 6.0 Ox 0 VIFx 13.0 260.0 st3 bednn 3 C 2039 0 111 0.036 6.0 Ox 0 VIFx 19.0 260.0 st3 clt2 C 0 0 0 0.028 4.0 Ox 0 VIFx 22.0 335.0 st3 dining C 2089 0 113 0.029 6.0 Ox 0 VIFx 27.0 320.0 st3 great rm c 2223 0 121 0.042 9.0 Ox 0 VIFx 35.0 205.0 st5 great rm-A C 2223 0 121 0.032 6.0 Ox 0 VIFx 46.0 265.0 st5 kitchen c 3268 0 177 0.029 8.0 Ox 0 VIFx 42.0 300.0 st4 laundry c 1725 0 94 0.054 6.0 Ox 0 VIFx 4.8 180.0 st3 pntry C 121 0 7 0.028 4.0 Ox 0 VIFx 31.0 330.0 st3 mic3 c 0 0 0 0.037 4.0 Ox 0 VIFx 9.0 260.0 st3 SupplyDetail Table I Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st3 Peak AVF 0 800 0.028 748 14.0 0 x 0 RectFbg st4 Peak AVF 0 418 0.029 533 12.0 0 x 0 RectFbg st3 st5 Peak AVF 0 241 0.032 691 &0 0 x 0 RectFbg st4 Bold/italic values have been manually overridden i 2017-Jun-01I07:54:54 wrightsoft' Right-Suite®lhiversal 201717.0.17 FLSU06570 Page 1 J:\TransferWlanual JWEWMAN RESIDENCE-2.rup Calc=MJ8 Front Door faces: E i j l ' TableReturn Branch Detail Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FIR (fpm) (in) (in) Opening(in) Mat[ Trunk rb3 Ox 0 0 800 0 0 0 0 Ox 0 VIFx I I I � 2017-Jun-01I07:54:54 1ti wrightsoft' Right-Suite®lhiversal 201717.0.17 RSW6570 Page 2 ZC�% J:\TransferkManual JWEWMAN RESIDENCE-2.rup Calc=MJ8 Front Door faces: E I t Duct System Summary Job. - - wrightsoft� y Date: Apr 11,2017 UNIT TWO By: Dli FRANCESCO I Project I • • For: NEWMAN RESIDENCE 2275 BROCKSMITH RD, FORT PIERCE, FL Heating Cooling External static pressure 0 in H2O 0.10 in H2O Pressure losses 0 in H2O 0 in H2O Available static pressure 0 in H2O 0.10 in H2O Supply/return available pressure 0.000/0.000 in H2O 0.050/0.050 in H2O Lowest friction rate 0 in/100ft 0.068 in/100ft Actual air flow 590 cfm 590 cfm Total effective length(TEL) 148 ft Supply Branch DetailTable I Design Htg Clg Design Diam H x W Duct Actual Ftg.Egv Name (Btuh) (cfm) (cfm) FR (in) (in) Matl Ln(ft) Ln(ft) Trunk LANDING c 1105 0 60 0.068 5.0 Ox 0 VIFx 17.7 130.0 st2 MSTR BATH c 1821 0 98 0.069 6.0 Ox 0 VIFx 15.0 130.0 st1 MSTR BEDRM c 3599 0 194 0.070 8.0 Ox 0 VIFx 13.5 130.0 st2 MSTR WIC 1 c 872 0 47 0.069 4.0 Ox 0 VIFx 15.0 130.0 st1 MSTR WIC2 c 463 0 25 0.070 4.0 Ox 0 VIFx 12.5 130.0 st1 OFFICE c 2939 0 159 0.068 7.0 Ox 0 VIFx 16.8 130.0 st2 STORAGE c 139 1 0 7 1 0.070 1 4.0 1 Ox 0 I VIFx 1 13.7 130.0 st1 I i SupplyDetail Table I Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (cfm) FR (fpm) (in) (in) Material Trunk st1 Primary 0 178 0.069 402 9.0 0 x 0 RectFbg st2 Primary 0 412 0.068 756 10.0 0 x 0 RectFbg I Return Branch Detail Table i Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size(in) (cfm) (cfm) (ft) FR (fpm) (in) (in) Opening(in) Matl Trunk rb2 Ox 0 0 590 0 0 0 0 Ox 0 VIFx Bold/italic values have been manually overridden • 2017-Jun-01 07:54:54 wrightsoft° Right-Suite®thiversal 201717.0.17 MU06570 Page 3 + J:\Transfer\Manual J\NEWMAN RESIDENCE-2.rup Calc=MJ8 Front Door faces: E i i r Date: Static Pressure and Friction Rate D wrightsoft- I Date: Apr 11,2017 UNIT ONE By: DIFRANCESCO I Project I • • I For: NEWMAN RESIDENCE 2275 BROCKSMITH RD, FORT PIERCE, FL Available • Pressure Heating Cooling (in H2O) (in H2O) External static pressure 0 0.10 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0 0 Return grilles 0 0 Filter 0 0 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0 0.10 Total - • Supply Return (ft) (ft) Measured length of run-out 3 0 Measured length of trunk 13 0 Equivalent length of fittings 345 0 Total length 361 0 Total effective length 361 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0 <0.06 0.028 <0.06 Return Ducts 0 <0.06 0.028 <0.06 i Fitting Equivalent LengthDetails Supply 4AD=60, 911=85,2A5=80,911=85, 1A=35:TotalEL=345 Return TotalEL=0 i �A;. + wrightsoft° Right-Suite® 2017-Jun-01107:54:54 thiversal 201717.0.17 RSU06570 Page 1 J:\Transfer\Manual J\NEWMAN RESIDENCE-2.rup Calc=MJ8 Front Door faces: E I I I wrightsoft' Static Pressure and Friction Rate Date: Apr 11,2017 UNIT TWO By: Dli FRANCESCO I Project I • • For: NEWMAN RESIDENCE 2275 BROCKSMITH RD, FORT PIERCE, FL �s Available _ Heating Cooling I (in H2O) (in H2O) External static pressure 0 0.10 Pressure losses Coil 0 0 Heat exchanger 0 0 Supply diffusers 0 0 Return grilles 0 0 Filter 0 0 Humidifier 0 0 Balancing damper 0 0 Other device 0 0 Available static pressure 0 0.10 Total • Supply Return (ft) (ft) Measured length of run-out 8 0 Measured length of trunk 9 0 Equivalent length of fittings 130 0 Total length 148 0 Total effective length 148 Friction Heating Cooling (in/100ft) (in/100ft) Supply Ducts 0 <0.06 0.068 OK Return Ducts 0 <0.06 0.068 OK I Fitting Equivalent LengthDetails Supply 2A0=35,4AD=60, 1A=35:TotalEL=130 Return TotalEL=0 .� wri htSoft• 2017-Jun-0107:54:54 9 Right-Suite®lhiversal 201717.0.17 RS1�6570 Page 2 JATransfer\Manual JWEWMAN RESIDENCE-2.rup Calc=MJ8 Front Door faces: E i (