HomeMy WebLinkAboutInspection Docs Ilk
4
KELLER, SCHLEICHER & MacWILLIAM ENGINEERING ARID TESTING,' INC.
MARTIN(772)337-7755 P.O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772)589-0712
PALM BEACH (561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488
FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772)229-9093
C.A.:5693 FAX(772)589-6469
July 26, 2017
DiFrancesco Construction, Inc.
Michael DiFrancesco
8840 Lonesome Pine Trail
Ft. Pierce, FL. 34945
I
Re: 2275 Brocksmith Road _
Fort Pierce, Florida
Permit#: 1704-0577
KSM Project#: 172156-2d
Dear Mr. DiFrancesco:..
Enclosed, please find the nuclear density test results performed on the compacted
foundation fill at the above referenced project.
` #6 IYW'hoxe any questions, please feel free to contact the office.
y ' '
�• E� l e er.,
JE' b¢llli���`
E-mail to: difranconstinc@aol.com
Fax and Mail to: St. Lucie County Building Department �
i
RECEIVED AUG` 012017
Ronald G. Keller, P.E.: 37293 1 SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366
00
KELLER, SCHLEI'CHER & MacWILLIAM ENGINEERING AND TESTING,! INC.
MARTIN(772)337-7755 P.O. BOX 78-1377 SEBASTIAN FL 32978-1377 SEBASTIAN (772)589-0712
PALM BEACH (561)845-7445 www.ksmengineering.net MELBOURNE(321)7168-8488
FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE (772)229-9093
C.A.:5693 FAX(772)589-6469
I
SOIL COMPACTION REPORT
ASTM D 1557 and ASTM D 2922
DATE TESTED: 'July 26", 2017 KSM JOB #: 172156-2d/MH/cc
PERMIT#: 1704-0577 1
CONTRACTOR: DiFrancesco Construction
i
JOB LOCATION: 2275 Brocksmith Road
Fort Pierce, Florida
MATERIAL: Brown Sand with Shell Fragments
ITEM TESTED: Compacted Foundation Fill — Re-Test
- - -- -- - - -- - - - -- - - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - -- - - - - - - - - - - - - - - - --
TEST LOCATION DEPTH MOTS- PEN DRY MAX. DRY PERCENT
OF SAMPLE TURE READ DENSITY PROCTOR COMPACTION
VALUE
- -- - - - - - -- - - - - - - - - - - - - - - - - - - - - -- - - - - - - - - - - - - -- - - - - - - - - - - - - - -
1. S.W. 0" — 12" 14.6 52 112.0 113.6 98.6
I
2. N.W. 51 111.1 It97.8
3. Center 50 109.3 96.2!
4. S.E. 50 108.1 95.21,
5. N.E. 50 109.6 96.S
I
I
I
I
I
I
i
Ronald G. Keller; P.E.: 37293/SI Lic. No.: 860 / Julie E. Keller, P.E.: 68366
j
i
v Ilk 9 • �
KELLER, SCHLEICHER & MacWILLIAM ENGINEERING AND TESTING, JNC.
MARTIN(772)337-7755 P.O. BOX 78-1377, SEBASTIAN, FL 32978-1377 SEBASTIAN (772)589-0712
PALM BEACH (561)845-7445 www.ksmengineering.net MELBOURNE(321)768-8488
FAX(561)845-8876 E-Mail: KSM@KSMENGINEERING.NET ST. LUCIE(772)229-9093
C.A.:5693 FAX(772)589-6469
MOISTURE-DENSITY RELATIONSHIP
MODIFIED PROCTOR (ASTM D 1557)
DATE TESTED: July 26", 2017 KSM JOB #: -it 2-1
PERMIT#: 1704-0577
I
CONTRACTOR: DiFrancesco Construction Inc.
I
JOB LOCATION_ 2275 Brocksmith Road
Fort Pierce, Florida
115 - -- - - - - -- - - - -- - - - -- -
T T -� I r 7 �
I I I I I I I j
I I I I I I I
1144-- -- 4- -- - - - - - -I-- -- - -- - 4 -- --I
v= I I I I I
U 113 - - - - - - — - -I- - —\1T
W112 T- - - - T -- , - -- -I I
I I I I I I I
111 4- - - - + -- - -I - - - -I- - - - 4- - - - 4 -- --4
I I I I I I I
I I I I I I I
110 - - - -- - - - -- - -- -- �- - - - - - - -�
8 9 10 11 12 13 14
Moisture- Percent of Dry Weight
Soil Description: Brown Sand with Shell Fragments
Max. Dry Density: 113.6 P.C.F.
I
Optimum Moisture: 11.0 Percent
Julie E. Keller, P.L
President
Ronald G. Keller, P.E.: 37293/SI Lic. No.:860 / Julie E. Keller, P.E.: 68366
• Termite Ihspection eSUs Christ is nor 0772-323-7921
• Termite Pretreatment �® if Buy p Toll Free: 1-877-365-9990
• Pest Control Termite & Fax: 772-340-599.0
• Rodent Service Pest
• Fire Ant Lawn Service Control, Email: Evictabug@gmail.com
• Whitefly Treatment Inc. 2373 SW Woodridge St.
i
• Licensed & Insured Lic.JB175775 Port St. Lucie, FL 34953
I Notice of.Preventative Treatment for Termites
(as required by Florida Building Code(FBC)104.26 and Broward County Chapter FBC 105.2.2)
PEST PREVENTION I FIRE ANT SERVICE l TERMITE SERVICE I RODENT EXCLUSION&REMOVAL I WHITEFLY TREATMENT
DATE OF SERVICE L{/ f X TIME C G
DEV LOPMENT jNAME(PROJ CT) CONTRAC �/TOR'S. AMEN CONTA/CT PERSSON�
C Cl Y?dUl A/��.(J 1til 1�1 A/1'/ I!--�'
STRUCTURE ADDRESS(LOT/BLOCK) CITY,STATE _ COUNTY_
NOTES v ^ . ' ZIP CODE
TREATMENT TYPEIAREA
❑FLOATING ❑MONOLITHIC ❑PATIO ❑GARAGE ❑DRIVEWAY ❑STEM WALLIFOOTERS ❑ADDITION
1
❑CUTOUTS ❑FOOTER ❑FRONT ENTRY ❑RETREAT ❑BORA CARE TREATMENT ❑PLUMBING CUTOUTS ❑SIDEWALKS
❑TAMP&TREAT ❑TREAT ONLY 31FINAL ❑POOL DECK ❑OTHER
PRODUCTS
❑BASELINErDOMINION 2LACTIVE INGREDIENT ❑TERMIDOR SC I>BORACARE ❑PREMISE ❑TALSTAR
❑OTHER
ACTIVE INGREDIENT PIMIDACLAPRID ❑BIFENTHRIN ❑DISODIUM OCTABORATE TETRAHYDRATE,
CONCENTRATION
❑.06%o ❑.12% ❑.25% �7.05% ❑23% El9% ❑OTHER GALLONS APPLIED ( G
SQUARE FOOTAGE LINEAR FOOTAGE 1 S
RECEIVED
SQUARE FOOTAGE VERIFIED
0-YES ❑NO m MEASURED OR VERIFIED PER PLANS APR 2 5.7018
e
JOB READY CONDITIONS MET PermittingSt. LucieD Counmem
111 YES ❑NO DETAILS
4 �
As per 104.2.6 FBC-If soil chemical barrier method for termite prevention is used.Final exterior treatment shall be completed prior to final building approval.
jCertificate of Compliance:The building has received a complete treatment for the prevention of subterranean termites. Treatment is in accordance with rules and laws established
I by the Florida Department of Agriculture and Consumer Services.(Per the Florida Building Code.)
G If this notice is for the final exterior treatment,initial and date this line
1 ,
FINAL STICKER �1 /
❑ELECTRICAL PANEL ❑ ATE WATER HER �OTHER //it
I Payment Terms: Payment due at time of service.
I
IV
Date Applicator.—(E i�Bug Termite and Pest Control,Inc.)
Date , Customer property Owner orAgent)
! `/ www.evictabugpestcontrol.com
Planning &Development Services
Building &Code Regulation Division
2300 Virginia Ave
• Fort Pierce, FL 34982 I
772-462-2172 Fax 772-462-6443
CERTIFICATE OF TERMITE TREATMENT
CONSTRUCTION,SOIL TREATMENT
PERMIT #: JOB, ADDRESS: 22?3� /JIoG S�rc�� �� %� �P'�re
BUILDER/CONTRACTOR:
PEST CONTROL CONTRACTOR: EVICT-A-BUG TERMITE&PEST CONTROL INC.
PEST CONTROL LICENSE #:JB17577.5
We, the undersigned, hereby certify that we have pretreated the above described construction for
subterranean termites in accordance with the standards of the National Pest Control Association.
Square feet if area treated: ' Chemicals used: DOMINION 2L
Percentage of solution: .05% Total gallons used:
Date of Treatment: Y�%�h Time of Treatment: 00
Footing Slab
Ist Treatment Ist Treatment
Re-Treat Re-Treat
Driveway Pools
Ist Treatment Ist Treatment
Re-Treat Re-Treat
Other Perimeter for Final Inspection
Ist Treatment
Re-Treat
�Siture of Exterminator Date
Note: There must be a completed form for each required treatment or re-treatment and this form must be on the job
site to be picked up by the inspector at time of each inspection or the scheduled Inspection will fall and a re insp,'eetion
fee charged.
FOC104.2.6 Certificate of Protective Treatment for preventlon of termites A weather resistant jobsite posting board
shall be provided to receive duplicate Treatment Certificates as each required protective treatment Is completed
providing a copy for the person the permit/s issued to and another copy for the building permit flies, The Treatment
Certificate shall pro vide'the product used, Identity of the applicator, time and date of the treatment,site location, area
treated, chemical used,percent concentration and number of gallons used, to establish a verifiable record of
Protective treatment. If the soil chemical bander method for termite prevention Is used, final exterior treatment shall
be completed prior to final building approval.
St Lucia County requires for the final inspection for CO, a Permanent Sticker to be placed�lon
the electrical panel box cover, listing all the treatments and dates of applications.
Rcviscd 7/24/2024
I i
I