Loading...
HomeMy WebLinkAboutPole barn plans0 0 0 0 SIRC 62.66' W 78.22' Z 79.59' SIRC LEGEND: SIRC = SET IRON ROD AND CAP PSM#6376 NORTH LINE OF THE SOUTHEAST Y4 OF SECTION PROPOSED o POLE BARN M S 8 9 05 6' 15" E 0 SHIP 35 SOUTH, RANGE 39 EAST NORTH SAINT LUCIE WATER MANAGEMENT DISTRICT CANAL NO. 43 0 6 6 7.6 5SIRC PROPOSED 20'INGRESS—EGRESS EASEMENT 529.08' 4, TOWN 70' 547.52 ................... ..................._..._ PROPOSED 10' N 89056'15" W 674.28' ft I: 2314-m-aootl-00 -s SIRC w 0 0 Ln N N n O 0 O 0 Cn PARCEL 2 LOCAT�ON MAP LEGAL DESCRIPTION: NW Y4 OF THE NW Y4 OF THE SE Y4 OF SECTION 4, TOWNSHIP SOUTH, RANGE 39 EAST LESS N 35 FT OF CANAL R/W (OR 3957-2506) LOT AREA: PARCEL 1 420,354 SQ. FT.; 9.65 ACRES± STREET ADDRESS: NOT AVAILABLE. SURVEYORS NOTES: 1. BEARINGS SHOWN HEREON ARE BASED ON THE NORTH LINE OF SECTION 4. 2. WRITTEN DIMENSIONS TAKE PRECEDENCE OVER SCALED DIMENSIONS AND NONE ARE INTENDED FCR CONSTRUCTION AND/OR DESIGN PURPOSES. 3. ALL DISTANCES AND BEARINGS ARE AS FIELD MEASURED AND ARE COINCIDENT WITH "PLAT AND DESCRIPTION DATA UNLESS OTHERWISE NOTED. 4. THIS DRAWING IS NOT VALID WITHOUT THE SIGNATURE AND ORIGINAL RAISED SEAL OF A FLORIDA LICENSED SURVEYOR & MAPPER. 5. THIS SURVEY IS BASED UPON A DESCRIPTION PROVIDED BY THE CLIENT. THERE HAS BEEF NO EXTENSIVE SEARCH OF THE PUBLIC RECORDS BY THIS OFFICE. 6. NO ATTEMPT HAS BEEN MADE TO LOCATE UNDERGROUND IMPROVEMENTS. 7. FENCE OWNERSHIP IS UNDETERMINED. 8. PARCEL ID NO. 2304-422-0001-000-2. CERTIFIED TO: DAVID BELLEVILLE MELIISSA BELLEVILLE. CERTIFICATION: I HEREBY CERTIFY THAT THE SURVEY REPRESENTED HEREON WAS PERFORMED UNDER MY SUPERVISION AND IT COMPLIES WITH THE MINIMUM TECHNICAL STANDARDS, AS SET FORTH BY THE FLORIDA BOARD SURVEYORS & MAPPERS IN CHAPTER 5J-17.050(10)(A)-(K) OF THE FLORIDA ADMINISTRATIVE CODE, PURSUANT TO SECTION 472.027, FLORIDA STATUTES, AND FURTHER THAT THERE ARE NO VISIBLE, ABC GROUND ENCROACHMENTS UNLESS SHOWN OR NOTED. RECEk D APR - 2017 vIARSHALL Surveying & Mapping 321 HOLLY AVE Port Saint Lucie, Florida 34952 .3t: � , Lc �.o STEVEN D. MARSHALL PSM 637 Boundary Survey/Site Plc Prepared on the order of: DAVID BELLEVILLE Field: SM & RA Job No 16 ,"(�;1 Drawn: SDM Date: 10/17/2( Scale: 1 " = 40' Sheet: 1 of UNSHEETED CONTINUOUS BRACING NOTE Bottom Chords are not sheeted. Builder must laterally brace unsheeted chords. See individual truss engineering for bracing requirements. 12 - 4.00 CID 14' M 3 upset=1/4" heel=315/16" 1 � SQUARE CUT END 2'-10 5/6" 2 x 4 Top Chord WALL HEIGHT 14' TYPICAL END DETAIL i 90.11 MITEK 4.2 SUCH AS SBC 1604.6.UCIBLE DESIGN CRITERIA PER LOADING/DESIGN County SAINT LUCIE Building Department City of PORT ST LUCIE Wind Design Criteria ASCE 7-2010 Wind Design Method Main Wind Force Resisting Roofing Material Metal Roof Loading in PSF Roof R.D.L. Top Chord Live 20 Top Chord Dead 7 4.2 Bottom Chord Live 10 Non -Concurrent Bottom Chord Dead 10 3 TOTAL Load 37 7.2 Duration Factor 1.25 Wind Speed 170mph Top Chord C.B. Sheeting by builder. Bottom Chord C.B. Bracing (See Note) Highest Mean Height 17'-0" Building Type OPEN Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2014 R.D.L.=Restraining Dead Load C.B.=Continuous Bracing Chambers Truss Inc. Drawing Name: 73954 Scale: 1 /4 = 1' 24 total trusses, 2 different trusses. Date:12/09/16 REVISED:2/21/17 FOR HIGGINS BROTHERS DESCRIPTION: DAVE BELLVILLE 73954 / CLOUDED AREAD ARE OF SPECIAL CONCERN 4 MUST BE CHECKED C,4RE=FULLY 4 MAY i INDICATE DEVIATION FROM PLANS. NOTES: ' - - *ALL BEAMS BY OTHERS. *CEILING IS FLAT. *DESIGNED WITH STRUCTURAL GABLE ENDS. TDI IC TYPICAL GAIDLE ENDS NOT SHOWN GALV. STEEL ROOFING SCREWED PER MFG. SPECS OVER is/32" CDX PLYWOOD ENGINEERED WOOD 2 x 4 - 4' O.G. NAILED TO BOTTOM OF TRUSSES o 24" O.C. TOP CHORD OF IST 4 TRUSSES w/ (2) I&D NAILS EACH PLY OF EACH TRUSS 5/8" COX SHEATHING NAILED I I I I ® 6"1. w/ IOd NAILS I I lU ROW 2 x 4 GROSS BRACING IN CENTER OF TRUSS NAILED I w/ (2) 111 NAILS (U LSTAIS 14-I0d NAILS I I I I I o GABLE TRUSS TO BEAM —' H o EA UPRIGHT TYPICAL / (2) 2 x 12 2 x 4 4' O.C. NAILED FLITCH BEAM TO TOP OF BOTTOM CHORD OF EA TRUSS w/ (2) 160 NAILS EACH PLY OF EACH TRUSS TYPICAL GABLE END STRUCTURAL GABLE ENDS STRUCTURAL GABLE ENDS METAL ROOFS SHOW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN LAYOUT BY OTHERS TYPICAL " 0 TYPICAL TRUSS CONNE.TIONS w/ (1) LSTAIS 14-I0d MILS g EA TRUSS TO BEAM TYPICAL METAL ROOFING BY SUh_AST METALS "KEY WEST SERIES" �V CRIMP FL 019621.1 / -181325 PSF " PRE-ENG. TRUSSES 024 O.G. 12 SCREWED 8 O.C. PER'IFG. SPECS w/ (1)LSTAIS 14-IOd NAILS 4 OVER TYP/ PEEL 4 STICK FOLLED ROOFING R TRUSS TO BEAM OVER 19/32" CDX PLYWOOD TYPICAL PT 2 x 4 RAT RUNS ® MAX 4' O.G. NAILED TO EA TRUSS w/ (2) 16D TYPICAL BEAM CONNECTED TO POST w/ (4) 111 NAILS 4 (1) 5/8" THRU BOLT Lill 2" WASHER 4 NUT TYPICAL w/ (1) LSTAIS 14-I0d NAILS Is GABLE TRUSS TO BEAM m EA UPRIGHT TYPICAL (2) 2 x 12 PT FLITCHED BEAM w / 1/2" COX PW BETWEEN NAILED TOGETHER w/ (3) ROWS OF 120 NAILS 0 MAX 12" O.G. TYPICAL ROUND POLES TO' OF BEAMGRADE 2'-oil F �- -- - - - - CONCRETE GRADE -- - F------------- - -------1 Q TYPICAL ROIND POLES MIN TYPICAL POLE BARN END ELEVATION INTO GROUND 410'-0" 9l�s" 8'-IOf's" 8'-IOIh° 8'-II" - 8'-I01'2" 8'-101"S" 9l�I d d ° d ° d ° 4 ` ° 4 ° 4 ° ® ° d ° 4 Do D'o DA Do o Do Do Do . DA Do D•o Do Do Do Do D'o Do DA Do D o D o D rr D o D P D o D o D o D > D o D o D o D. o� D. o D,> D. n D. o D o D o D o D o D o D o ° ) ° 4 ° �o DA ) o D o n d ° ) > D o ° d ° A D,o ) ° 4 ° A Do o D o ° d ° •o D •o ) P D o ° d ° o D,o � D o e d n o Do ) o D P ° d ° D .)o- o .dD•o .dD'.dD•.dD•.dD•.d A o o o D•o .dD•o .db% .db% n n d Do d , D•o D o D o d d 16% D,o ° ° p °, d Do d ° Do . D o D o d d ° D P n p n D o 4 ° d ° d ° D P D o d d " Do Do ) D P- D °' SEE TYPICAL POLE BARN SECTION' °' d ° ° d °° ° d ° d ° d °° d d ° °, 4 n p o °12 o D o D•o D•o D•o o D•o D o ,o D o� p D o D o- D n n n Y o D n x o� p D n P� ° n D o- ° n D ..o d o D u� ° n D o� O n D TYPICAL �° D o ° D >' � o° C d d 4 d ° d d ° d ° d d d FLITCHED BEAM a 4 4 p o D o D A D TYPICAL D m D •o x D •o , D A D •o D m (2) 2 x 12 Pt w/ 1/2" PW • d D o. d D •o D o. °, o D _ D o ) D o a D ) o p° °, ) D o o °, D NAILED TOGETHER w/ (3) ROWS o - D o - D dDA .dD'A .dD ROUND POLES dDA .dDn .dDo .4Do .dDo .4Do .d OF 12D m NAILS MAX 12" O.C, o . d D •o . d D o ° d D ,o x ) > ) D o� x oD x P� D ) _ o D x _ o x D o� ) D P� D x o x D o� D. ° 4 °, 4 °, p °, p° p n V. p n p D'o D'A d Do Do o d 16 Da q 6 d ° d Do d .6 d ° Do d ° Do Do ° d � d DA o bo ° Do Do Do d D e 8'-II' �, 8'-104s' 8'-IOs" CONNECT BEAMS w/ (2) SIMPSON META 18 411 W/ 14-lOD/ST noniiwin rnawlea TYPICAL VOLE 5ARN LAYOUT TO EA. BEAM (TYP.) SCALE: 1/4" . 1'-0" TYPICAL POLE 5ARN 6IDE ELEVATIM SCALE: 114" • 1'-0" 2014 5TH ED FBC RESIDENTIAL 4 AMENDMENTS BASIC WIND SPEECd MIN 1&0 (ULT) RISK FACTOR LO BUILDING CATEGOIFY OPEN EXPOSURE CATEGORY C LEE FASTENERS OR ATTACNlr1EN; TK RESPON MLM OF THE CONTRACTOR OF RECORD TOP OF BEAM GRADE THESE PLANS AND ALL PROPOSED WORK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAYBE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE COD88, THESE TRUSS DRAWINGS HAVE SEEN REVIEWED AND ACCEPTED AS SIGNED 6 SEALED HERE SELOUI. df 00�'OS ST. LUC CO7B L`(G DIVISIQN REVIEWED FOR LIANCE REVIE BY DATE ST BE KEPT ON JOB PLANS OR NO INSPE TION WILL BE MADE. RECEIv -0 APR, a 1017 Q 00 Wcn ON m ON 1 Q) 0 C7 a °G M N WQw� rF� �U� V Z C �:) r a V1 � Uj U in tn Ul 'mod If— z much Ln U � u-uC4 ((� _ U, lit Z3 M 5- JU III z O M LL C Copyright 2017 ROBERSON DESIGN GROUP All rights reserved. JOB I-IR DATE : 2/21/17 DRAWN BY SR SHEET 1 Of 1 SCALE: 114" . 1'-O" ®=LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. 5PAGING NOTE 'ALL TRUSSES APE TO BE SET - AT 2'-C: ON CENTER EXCEPT AS NOTED MULTIPLE PLY TRUSSES MUST BE ASTENED TOGETHER PER ENGINEERIN BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMINE A IF MULTIPLE PLY. A& DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 30' Span or less '&30' to 60' Span A 6o degrees Spreader Bar or less -1/2-1— Tag Line span approx. REFER TO BCSI Truss must be set this way If crone used. Truss is on exam Ple, your truss may not match. Insist crane operator sets truss this way. ifag—_Approx 2/3 to_* Line 1/2 of Span REFER TO BCSI iss must be set this way if crone used. This Is an example, truss may not match. Insist crane operator sets truss this way. All load bearing walls, headers, beams & lintels must be in place at indicated height before trusses A are installed. AL A I FR " A " E::> I— E FZ " O T- IE= UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS. CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR. Carrying Girder For Truss to Truss Connections see hanger/connectorTNailsbe as detabs o schedule in engineeringe nails. .package. Carried Truss 77 INDICATES LOAD BEARING REQUIRED BY TRUSSES SUPPLIED BY BUILDER AT A HEIGHT OF 14'-0" ABOVE FINISHED FLOOR ,A Do not stand on trusses until they are braced per BCSI & properly nailed to straps & hangers NOTES: *ALL BEAMS BY OTHERS. *CEILING IS FLAT. *DESIGNED WITH STRUCTURAL GABLE ENDS. METAL ROOFS SHOW IMPERFECTIONS. SPECIAL INSTALLATION CARE MUST BE TAKEN UNSHEETED CONTINUOUS BRACING NOTE Bottom Chords are not sheeted. Builder must laterally brace unsheeted chords. See individual truss engineering for bracing requirements. I STRUCTURAL GABLE ENDS I _ I SGEA A A A A A A - - - - A A A A A A A A A A A A A A A A - scEA I I / \ I l ; STRUCTURAL GABLE ENDS :a CLOU`bED AREAS ARE OF \ / SPECIAL CONCERN & MUST BE ' CHECKED CAREFULLY & MAY 1 INDICATE DEVIATION FROM ` PLANS. -- 12 i 4.010 ` x i n 14' I � 1 °' 3 1 I j 2 "05 1 ' \ upset=1/4" heel=315/16" ` SQUARE CUT END \ 2 x 4 Top Chord WALL HEIGHT 14' ` TYPICAL END D^TAIL , . a bxrt .:ne613° A FABRICATION AGREEMENT TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED The legal description of the property where the trusses will be Installed Is: Jti@underslgned acknowledges and agrees: - ".1, Trusses will be made In strict accordance wlth this truss placement diagram layout, Vfilch is the sole authority for determining successful fabrication of the trusses. 2. Ali dimensions In this layout have been verified by the undersigned. ' '.�.1. Unless written notice is provided by cortified mall to Chambers Truss within tan (10) days of delivery the undersigned agrees that no backcharges, will be allowed. In the event such written notice Is fumished Chambers Truss shall have three (3) bulIllatess days In which to, begin repairs required, or to substitute other trusses, at Chambers option. i'.'4oThe underafgned acknowledges recelpt of "BCSI 1-03' summary sheet by TPI & WTCA. 4 Delh+err la to job site. It Is the buyer's' responsibility to make fhe job site suitable for delivery. Chambers Truss has the sole authority to determine the sulf Wlity of the job site or a portion of the job site for delivery. Chambers Truss will be reeponslbie for dump delivery only. The buyer Is responsible for additional delivery expenses B Chambers Truss has to redetiver because job site is not prepared for delivery or buyer Is not prepared for delivery of trusses. "i saIs responsible to Chambers Trues for towing costs due to she conditions. '� 9>Pdoe as shown In paragraph 7 below Is subject to change Ifany changes ere. made In this layout A $50 per hour fee for revisions may be charged by Chambers Truss. , ': T:;:ThIs Is a PURCHASE ORDER to ChamberbTruss of the sum agreed to, or If n6.. ;agmWment a reasonable lodes. Invoice will be made on delivery and paid within terms of net' on�ddllvery. Invoice may be made at scheduled date of delivery If buyer cannot accept "4dt.very of fabricated trusses. The undersigned agrees to pay Chambers.TNas reasonable at6rney's fee for collections In event of payment not timely made. 1-1f2 %per month service charge will be added for all sums not paid within tens. , B: Signature or Initials anywhere on this sheet constitutes agreement to all terms herein. 9. In consideration of Chambers Truss extending credit for this material the undersigned uncondlgonally guarantees payment when due of any and all Indebtedness owed to 'Chambers Truss by any eni receiving material and the undersigned agrees to pay such Indebtedness Including attorneys fees, If default In payment for material be made by the recipient. 1. 10. In the event of any litigation conceming this agreement, the hems fumished hereunder or payments referred to herein, the, parties agree that the sole venue for any such action will 'beSalnt Lads County, Florida. �1t.; Design responslbillties are per "National Standard And Recommended Guidelines On Rasponsiblllties For Construction Using Metal Plate Connected_ Wood Trusses A,NSVTPVWTCA 4 - 2002" _ .'DATED .. .-..v. rit ,SIGNED :�oR TITLE . c•L: 7►spraaderbarmaybe regglled per"BCS11-03"te pregerlt6>fiay&damage. 'Multiple ply trusses must be fastened together per engineering '-" isiore they are set; failure to do so can result In roof collapse.' Riporary and permanent bracing are required and can save life and property and Is the responsibility of the truss erector. Sltlidy the contents of the Information packet Included on delivery before setting trusses. tsati'1:�. ^a TniasesmustbesetandbracedperdesigntopmvatkiW&damage. Trusses must be set plumb and square `Do not set bunks or stack of plywood, roofing material or any ,.other Concentrated loads on trusses, this can cause collapse. ,.I DO NOT SET TRUSSES USING THIS LAYOUT USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES CHAMBERS TRUSS INC dtll �. "' ° 3105 Oleander Avenue Fort Pierce; Florida 34982-6423 800-551-5932 xkrtPierce 772466.2012 Fax 772.465-8711 11 o V?o Beach 772-569.2012 Stuart 772-286-3302 4 Yt' Wah SIM! CHAMRERSTRUSS.COM 92.0/93.2 MITEK 4.2 DESIGN CRITERIA County SAINT LUCIE Building Department City of PORT ST LUCIE Wind Design Criteria ASIDE 7-2010 Wind Design Method Main Wind Force Resisting Roofing Material Metal Roof Loading in PSF Roof R.D.L. Top Chord Live 20 Top Chord Dead 7 4.2 Bottom Chord Live 10 Non -Concurrent Bottom Chord Dead 10 3 TOTAL Load 37 7.2 Duration Factor 1.25 Wind Speed 170mph Top Chord C.B. Sheeting by builder. Bottom Chord C.B. Bracing (See Note) Highest Mean Height 17'-0" Building Type OPEN Building Category II:Non Restrictive Exposure Category C Barrier Island No Conforms to FBC 2014 Verify DESIGN CRITERIA shown above with the building department and your engineer. Design Criteria is the responsibility of the Chambers Truss Inc. Drawing Name: 73954 Scale: 1 /4 = 1' 24 total trusses, 2 different trusses. MI 4: BLW ACAD: BLW Reviewed By: Date:12/09/16 Revised:02/21/17 FOR HIGGINS BROTHERS DESCRIPTION: DAVE BELLVILLE PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 2 TRUSS DRAWINGS ARE ATTACHED Tn !-AY0tJT 73954