HomeMy WebLinkAboutEngineering ' . File Copy
ENGINEERING SUBMITTALS
April 11, 2017 APR a 5 sir
WIND LOAD CERTIFICATION: '
I
i
CODE FBC 2014 5TII ADDITION/FRC 2014/ASCE 7-10
CQNCFALED FASTENERS OR AlIIACNME0
WIND SPEED: 170 mph,3 SEC. GUST kg THE RESKNM1LfN'1bF T
EXPOSURE: "D"
r� TR�,C,I0R0FR rl R(!
IMPORTANCE FACTOR: 1.0
INTERNAL PRESSURE coEFF.: 0.00 ARE SUBJECT TO ANY PLANS AND ALL PROPOSED woRx
CORRECTIONS
REQUIRED BY MELD INSPECTORS THAT.
HE MECESSARY IN 0RDER TQ.
C M P W WITH a�
JOB:
MITCHELL RESIDENCE
248 NETTLES BLVD 4
S.T.F UCTE COT 7,Tti BUIrD7:13 DWISIGN
JENSEN BEACH,
PLAINS ANTI3 PE_0,T-1 T MUST BE Iv EEPT ON JOD
PAUL WELCH INC.
Mechanical Electrical Civil Engineering
1984 S.W. Biltmore St. Suite#114
Port Saint Lucie, FL 34984
Phone (772) 785 - 9888
Email —p_-welchinc@aol.com
Paul Welch, P.E. Fla Reg. No. 29945
a
' ISLA?3D S0UT,'H
0POO ;
�T*
; j
248 Nettles Boulevard {
�ri:SErvti - ¢
Z T-
(�w JLlI�
- ZJ LLLL•0
VUWWUO
• JHoUJZ
wVO::)w�
3U12�-3:w
—JLU CC
—�
-- <=CO U)
2 0)
O
MI TCHELL — -- --: - Jerner&Associates,Inc. SHEET 1
-'- - - Marine&Environmental Consulting Date: 318117
248 NETTLES BLVD `" 2537 SE Alfonso Ave. Port St.Lucie,FL34952
Ph.(772)283-2950
JENSEN BEACH . --w
(i=.5 _. 'r� JERNER@BELLSOUIH.NET
1
iz KAYAK LIFT/LADDER
0
CA-
�- ►� SEAWALL%MHW
5 6 34.64'SHORE %
NO PORTION OF DOCK STRUCTURE OR
2/ ELECTRIC TO BE AFFIXED TO SEAWALL /QQ Z J U
N
VUW OWU
J��U �Z
tuU.�?w
3w w
• :D JZJCL
:� co
aww��—°aw
rn�
r
I"— 10'
MI TCHELL ; _ �r _
---------1 Jerner Associates,Inc. SHEET 2
1 Marine&Environmental Consulting Date: 318117
• f
2537SEAl onsoAve. Port St.Lucie,FL34952
248 NETTLES BLVD y
JENSEN BEACH L Pl (77z)z83-29so
--A
JERNER@BELL.SOUTH.NET
Dock Section Thru Dock Plan View
---- - - - ----- - --- - -----
2-X 6-CAP,TOP&MID RAILS ON
EAST&NORTH SIDE OF DOCK Live Load 40 lbs./Sq Ft
Dead Load 5 lbs./Sq Ft
10.5
SGL Bolts,Nut, jai►
Washers 5/8"H.D.—gyp+_ !i i� - -•+!•-•-•-^
Galv. Or S.S. (304) 0�Tq �.
i Nut Fully Threade .......
- -;�•-•-• ._•'_•' ;T
SEAWALL
CAP - 1"x 6"LUMBEROCK
Decking w Minimal plank
••' ' ! `' 1 ! � spacing. Fasten w#10 3" i�
!,
• ' SS(304) Screws, 2 per j -----71 ;; i; ;u, O
+ Stringer 0 rn
2"x 8"P.T. SYP' .40
i;
�Q�—'��, ii n •• ni o
! ACQ treated stringers to
_.MN1!1�. be butt jointed,buff ' ' u •--+
_._..! .._.._.._.._.._.._.._.. ,
_,�]�Y►!_,. joints to be staggered.
I ,
_. _.._.._.._.._.._.._..$ I i i h i
2"x 8"P.T. SYP, .40
ACQ treated DBL bents
' —�
co
i Of
i - r(C
GRADE "— — - W N
��r s'v3;r ti%5" ^,'tip•.' ^v v,:n vt'rir�.'�" C) J W-
f��v. ✓ v v n 0_
.r "`�•'�'' '` � ��` �: y���c'• Stringers 24° Z�_F.;U. C)
Min. 8"Dia. 2.5 0.C.Ma =— w=
CCA treated piles t enter Stringer(s)toe Nailed w(2) #16 SS J U ui—U O
• (304)Ring Shank Nails @ Each Bent, Outside W O O D w Z
r
Stringers Face Nailed w#16 SS(304) Ring S'J i- :w
Shank Nails, Inside or Outside Stringers ::D W J Z D¢
Pilings jetted to a minimum depth of 6'and as - _ a0�U)CL
— necessary to provide adequate bearing and stability �Mm
UA O
MI TCHELL Jerner&Associates,Inc. SHEET 3
-- -- - -'- Marine&Environmental Consulting Date: 318117
248 NETTLES BLVD "- ; i J
- � 1—,"^" � 2537SEAIonsoAve Port St.Lucie,FL 34952
E _ PIL(772)283-2950
J NSEN BEACH ,d° . �A F 3 JERNER@BELLSOUTH.NET