Loading...
HomeMy WebLinkAboutProduct Approval Florida Building Code Online Fie, COPY Page 1 of 3 -- = BCIS Home Log In c User Registration Hot Topics Submit Surcharge Stats&Facts Publications FBC Staff BC[S Site Map ; Links Search j FA TS"1�� OR T�iACHMEN ci— Product Approval USER:Public User ARE.K '��+Ixllkn� 181D��srlfn�1`nF{1nT1��; Product Approval Menu>Product or Aoolication Search>Aoolication List>Application Detail MC TOR OR of END FL# FL11651-R2 - Application Type Revision Code Version 2014 THESE PLANS AND ALL PROPOSED WORK Application Status Approved ;r ARE SUBJECT TO ANY CORRECTIONS Comments .REQUIRED ff�f FIELD INSPECTORS THAT Archived �9 1�is y�7�9� I�EC 67a: Y•:SCN 0RDER:TO` Product Manufacturer Gulf Coast Supply&M q �$X , LLLI�ALL APPLICAM CODES.- Address/Phone/Email 4020 S.W. 449th Street Horseshoe Beach, FL 32648 (352)498-7852 ray@gulfcoastsupply.com Authorized Signature Ray Bowen ray@gulfcoastsupply.com rr`` Technical Representative Address/Phone/Email ST•Lj CT-F..',C0LjNj'TN-' —RUTL'DTN 'DIVISION RIMEWLD FOR c'2—j L4 NICE Quality Assurance Representative REVIL"" Address/Phone/Email DATE�A- PLANS AIND PERMIT IMUST BE KEPT ON JO Category Roofing ©Q �I1`Cp,EGTMN Wk v!iDE. Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report-Hardcopy Received Florida Engineer or Architect Name who developed the Daniel S. Kuhn Evaluation Report Florida License PE-75519 Quality Assurance Entity Keystone Certifications,Inc. Quality Assurance Contract Expiration Date 04/12/2024 Validated By Locke Bowden Validation Checklist-Hardcopy Received Certificate of Independence FL11651 R2 COI Cert of Ind Kuhn Eno.odf FL11651 R2 COI Letter of Name chanoe.Ddf Referenced Standard and Year(of Standard) Standard Year FM 4471 1992 TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2004 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Code http://www.floridabuilding.org/pr/pr app_dtl.aspx?param—wGEVXQwtDqsQFc5K%2frr... 3/28/2017 Florida Building Code Online* Page 2 of 3 Product Approval Method Method 1 Option D Date Submitted 07/01/2015 Date Validated 07/10/2015 Date Pending FBC Approval 07/18/2015 Date Approved 08/18/2015 Summary of Products Go to Page Page 2/2 FL# Model,Number or Name Description 11651.21 26 Ga. GulfRib 26 Ga.GulfRib over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R2 II 21 R2 26GulfRib 1x4 15-32Plvwood NonHVHZ.odf Approved for use outside HVHZ: Yes FL11651 R2 II 21 R2 Metal Roof Panel Detail.pdf Impact Resistant: N/A Verified By: Dan Kuhn,P.E. 75519 Design Pressure: +N/A/-164.2PSF Created by Independent Third Party: Yes Other:-109.25 psf @ 24"o.c. fastener spacing. Evaluation Reports -164.25 psf @ 12" fastener spacing. Install per FL11651 R2 AE 21 R2 26GulfRib 1x4 15-32Plvwood NonHVHZ.pdf manufacturer's details. Not for use in HVHZ Created by Independent Third Party: Yes Zones 11651.22 26 Ga. GulfRib 26 Ga.GulfRib over 15/32" Plywood Li se' Installation Instructions Approved for use in HVHZ: No FL11651 R2 II 14FL11651 22 R2 26GulfRib IS- Approved for use outside HVHZ: Yes 32Plvwood NonHVHZ.Ddf Impact Resistant: N/A FL11651 R2 II 22 R2 Metal Roof Panel Detail.odf Design Pressure: +N/A/-159.2PSF Verified By: Dan Kuhn,P.E.75519 Other:-69.25 psf @ 24"o.c.fastener spacing. Created by Independent Third Party: Yes -159.25 psf @ 12" fastener spacing. Install per Evaluation Reports manufacturer's details. Not for use in HVHZ FL11651 R2 AE 14FL11651 22 R2 26GulfRib 15- Zones 32Plvwood NonHVHZ.pdf Created by Independent Third Party: Yes 11651.23 26 Ga. GulfRib 26 Ga.GulfRib over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R2 II 23 R2 26GulfRib 15-32Plvwood HVHZ.odf Approved for use outside HVHZ: Yes FL11651 R2 II 23 R2 Metal Roof Panel Detail.pdf Impact Resistant: N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure: +N/A/-159.2PSF Created by Independent Third Party:Yes Other: -71.75 psf @ 24"o.c.fastener spacing. Evaluation Reports -159.25 psf @ 12" fastener spacing. Install per FL11651 R2 AE 23 R2 26GulfRib 15-32Plvwood HVHZ.pdf manufacturer's details.For use in HVHZ Zones Created by Independent Third Party: Yes 11651.24 26 Ga. GulfRib 26 Ga.GulfRib over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes FL11651 R2 II 24 R2 26GulfRib 1x4 15-32Plvwood HVHZ.pdf Approved for use outside HVHZ: Yes FL11651 R2 II 24 R2 Metal Roof Panel Detail.pdf Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-164.2PSF Created by Independent Third Party: Yes Other:-106.75 psf @ 24"o.c. fastener spacing. Evaluation Reports -164.25 psf @ 12" fastener spacing. Install per FL11651 R2 AE 24 R2 26GulfRib 1x4 15-32Plvwood HVHZ.pdf manufacturer's details. For use in HVHZ Zones Created by Independent Third Party: Yes 11651.25 29 Ga. GulfRib 29 Ga.GulfRib over 1x4 Wood Purlins over 15/32"Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R2 II 25 R2 29GulfRib 1x4 15-32Plvwood NonHVHZ.pdf Approved for use outside HVHZ: Yes FL11651 R2 II 25 R2 Metal Roof Panel Detail.0f Impact Resistant: N/A Verified By: Dan Kuhn,P.E.75519 Design Pressure: +N/A/-123.5PSF Created by Independent Third Party: Yes Other: -76.75 psf @ 24"o.c.fastener spacing. Evaluation Reports -123.5 psf @ 24" fastener spacing. Install per FL11651 R2 AE 25 R2 29GulfRib 1x4 15-32Plvwood NonHVHZ.Ddf manufacturer's details. Not for use in HVHZ Created by Independent Third Party:Yes Zones 11651.26 29 Ga. GulfRib 29 Ga.GulfRib over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No FL11651 R2 II 26 R2 29GulfRib 15-32Plvwood NonHVHZ.pdf Approved for use outside HVHZ: Yes FL11651 R2 II 26 R2 Metal Roof Panel Detail.pdf Impact Resistant: N/A Verified By: Dan Kuhn,P.E.75519 http://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsQFc5K%2f Tr... 3/28/2017 �. �e illo : G SUPPLY & MANUFACTURING Y e ;. ULFR"AB FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 Product Evaluation Report He Copy GULF COAST SUPPLY& MANUFACTURING, LLC 26 Ga. GulfR®bTm Roof Panel over 15132"Plywood Florida Product Approval #11651.22 R2 Florida Building Code 2014 Per Rule 61 G20-3 Method: 1 —D Category: Roofing Subcategory: Metal Roofing Compliance Method: 61 G20-3.005(1)(d) NON HVHZ Product Manufacturer: Gulf Coast Supply & Manufacturing, LLC. 14429 SW 2nd Place, Suite G30 Newberry, FL 32669 `�.oPN.. . S G E IVS� Engineer Evaluator: *; No. 75519 ®an Kuhn, RE. #75519 = � Florida Evaluation ANE ID: 10743 ;13-, STATE OF :4Z %IFS AI � O R I 0 P ,-���;� s'••.. .. •' . Validator: �'1,�ONAL &GN Locke Bowden, P.E. #49704 0�'3 0' 2075 9450 Alysbury Place / Montgomery, AL 36117 Contents: Evaluation Report Pages 1 — 5 FL#11651.22 R2•JUNE 15,2015 1167033498 ID SUPPLY & MANUFACTURING TM GULFK 0 1 ' 26 GUAGE GULFRIBTMOVER • • r FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 r� r TM Compliance Statement: The product as described in this report has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Product Description: GulfRibTM, 3/a" Rib Roof Panel, Minimum 26 Ga. Steel, 36" Coverage, through fastened roof panel over minimum 15/32" Plywood Decking. Non Structural application. Panel Material/Standards: Material: Minimum 26 Ga. Steel, ASTM A792 or ASTM A653 G90 conforming to Florida Building Code 2014 Section 1507.4.3. Paint Finish Optional Yield Strength: Min. 80.Oksi Corrosion Resistance: Panel Material shall comply with Florida Building Code 2014, Section 1507.4.3. Panel Dimension(s): Thickness: 0.018" Minimum Width: 36" Coverage Rib Height: 3/a" Major Rib at 9" O.C. Panel Fastener: #9-15x1.5" HWH with sealing washing or approved equal '/a" minimum penetration through plywood. Corrosion Resistance: Per Florida Building Code 2014, Section 1506.6, 1507.4.4 Substrate Description: Minimum 15/32" thick,APA Rated plywood over supports at maximum 24" O.C. Design of plywood and plywood supports are outside the scope of this evaluation. Must be designed in accordance w/Florida Building Code 2014. Design Uplift Pressures: Table"A" fvlaxiirlum,To.talSUpirft Design Pre`ssu're° , 59 25psf pR z` Fastener Pattern 9"-9"-9"-9" 6.5"-2.5"-6.5"- 2.5"6.5"-2.5"-6.5" Fastener Pattern Spaang Design Pressure includes a Safety Factor=2.0. FL#11651.22 R2•1UNE 15,2015 • #30464 G ulfs SUPPLY & MANUFACTURING I BTIVI G U L F OR` 26 RIB PANEL OVER • • r Code Compliance: The product described herein has demonstrated compliance with the Florida Building Code 2014, Sections 1504.3.2. Evaluation Report Scope: The product evaluation is limited to compliance with the structural wind load requirements of the Florida Building Code 2014, as relates to Rule 61 G20-3. Performance Standards: The product described herein has demonstrated compliance with: • UL 580-06-Test for Uplift Resistance of Roof Assemblies • UL 1897-04- Uplift Test for Roof Covering Systems. Reference Data: 1. UL 580-94/1897-98 Uplift Test Force Engineering &Testing, Inc. (FBC Organization#TST-5328) Report No. 117-0062T-07A, B, Dated 02/19/2007 2. Certificate of Independence By Dan Kuhn, P.E. (FL#75519)@ Kuhn Engineering, LLC (FBC Organization #ANE ID: 10743) Test Standard Equivalence: 1. The UL 580-94 test standard is equivalent to the UL 580-06 test standard. 2. The UL 1897-98 test standard is equivalent to the UL 1897-04 test standard. Quality Assurance Entity: The manufacturer has established compliance of roof panel products in accordance with the Florida Building Code and Rule 61 G20-3.005(3)for manufacturing under a quality assurance program audited by an approved quality assurance entity. Minimum Slope Range: Minimum Slope shall comply with Florida Building Code 2014, including Section 1507.4.2 and in accordance with Manufacturers recommendations. For slopes less than 3:12, lap sealant must be used in the panel side laps. Installation: Install per Manufacturer's recommended details. Underlayment: Shall comply with Florida Building Code 2014 section 1507.4.5.1 and 1507.4.5.2. FL#11651.22 R2•JUNE 15,2015 _ O Gulfcco' T • a .' SUPPLY & MANUFACTURING TM GULFRIB 26 GUAGE GULFRIBTM PANEL OVER • • rr FLORIDA PRODUCT APPROVAL NO. 11651.22 R2 Roof Panel Fire Classification: Fire classification is not part of this acceptance. Shear Diaphragm: Shear Diaphragm values are outside the scope of this report. Design Procedure: For roofs within the parameters listed on the load table, fastening pattern must at a minimum meet those listed for the applicable wind zone. For all roofs outside the parameters listed on the load table, design wind loads shall be determined for each project in accordance with FBC 2014 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded.This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA or HVHZ evaluation report for use of this product in High Velocity Hurricane Zone. FL#11651.22 R2•JUNE 15,2015 G U I f c1a' I� ycrra SUPPLY Fa MANUFACTURING G �U .LFRI 26 GUAGE ' : PANEL OVER • •D FLORIDA PRODUCT APPROVAL NO. ENGINEER LOAD TABLE:26 Ga. GulfRibTM Panel over 15/32"Plywood Bu I lding's ( avmg a Roof.Mean Hejgh�s20 0" Roaf Slope 2,. L -,12 /12" Gal�{e or HIp,,,Roof W-Ind Speeds 120 .18i3rr1ph; Exposure C; Risk Category lI, EntlosecfrBuildirg based^on'Flonda B:tld(ng Code 2 120 130 140 150 160 170 180 WIIND FASTENER SUBSTRATE (MIN.1/4" SPEED penetration) (MIN.15l32") ON CENTER ON CENTER ON CENTER ON CENTER OIV CENTER ON CENTER ON CENTER SPACING SPACING SPACING SPACING SPACING SPACING SPACING ZONE 1.,' #9 15c1 5" ? Plyvyooci 24 TYPE 1 24'` TYPE 1'; 24",TYPE 1 ;24 ETYPE 1 24,',TYPE.1 24 TYPE 1 :24"TYPE 1,# ZONE 2 #9-15x1.5" Plywood 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 24",TYPE 1 �24",TYPE 1 12",TYPE 2 ZONE 3 #9 15x1.5" Plywoodr ' `24 TYPE 1 24'` TYPE 1 24",TYPE 7 :12 TYPE 2 12',TYPE 2 12 ':TYPE 2 12 TYPE,2 1.)PANEL DESCRIPTION:GULFRIBTM, MIN. 26 GA., GRADE 80,36"COVERAGE,3/4"TALL. 2.)PANEL FASTENER:#9-15X1.5" HWH WITH SEALING WASHER OR APPROVED EQUAL 3.)MAXIMUM ALLOWABLE PANEL UPLIFT PRESSURE: 69.25 PSF @ 24" O.C.FASTENER SPACING TYPE I FASTENER PATTERN, 159.25 PSF @ 12" O.C.FASTENER SPACING TYPE 2 FASTENER PATTERN BASED ON TAS 125, UL 580/UL 1897 TESTING. 4.)PLYWOOD DECKING:MIN.15/32"THICK PLYWOOD MUST BE DESIGNED IN ACCORDANCE WITH FLORIDA BUILDING CODE 2014. 5.)ROOF SLOPE:ON ROOF SLOPES LESS THAN 3:12, LAP SEALANT MUST BE USED IN PANEL SIDE LAPS. 6.)LOAD TABLE BASED ON WIND PRESSURES CALCULATED PER ASCE 7-10(KD=0.85)MULTIPLIED BY 0.6 PER FLORIDA BUILDING CODE 2014 ZONE 2 HIP ROOF Note:Dimension(a)is defined as 10%of the minimum width of the building or ZONE 3—,,af_ 40%of the mean height of the roof,whichever is smaller,however,(a)cannot be ---- r a less than either 4%of the minimum width of the building or 3 feet. 'TYPE 1 FASTENER PATTERN \) \---//—RIDGE 9„ 9" g /---_— t Panel la j t ' I / ZONE 1 \\\\ l Cant.Tape Seal for use on Slopes less than 3:12 I,/ fi9-15 x 1-1/2'w/Sealer Washer @ 241 O.C.Max. / — EAVE TYPE 2 FASTENER PATTERN ZONE2 GABLE ROOF ia a �('-6.5" 2.5"{-6.5"—{2.5" 6.5"—{2.5"{-6.5" 2.5" \ f ----------------- t � i / \` RIDGE L Cont.Tape Seal for use on Slopes less than 3:12� _\ l (1)#.9-15 x 1-1/2'w/sealer Washer @ 12'O.C.Max- ------------ 1-- I a --------------------- a F ZONE 1 � t i a -------------------- + \ZONE 3 EAVE FL#11651.22 R2•JUNE 15,2015 ® t •