Loading...
HomeMy WebLinkAboutHealth Department Septic Approval PERMIT #:56-SF-1 733732 �+ STATE OF FLORIDA APPLICATION #:AP 1271797 DEPARTMENT OF HEALTH DATE PAID: J ONSITE SEWAGE TREATMENT AND DISPOSAL FEE PAID: SYSTEM RECEIPT #: DOCUMENT #:PR1049523 CONSTRUCTION PERMIT FOR: OSTDS New APPLICANT: Lary A[tkens PROPERTY ADDRESS: Lot 98 Navion Rd' Port Saint Lucie,FL 34987 LOT: 98 BLOCK: SUBDIVISION: Treasure Coast Air Park PROPERTY ID #: 4224-501-0098-000-1 [SECTION, TOWNSHIP, RANGE, PARCEL NUMBER] [OR TAX ID NUMBER] SYSTEM MUST BE CONSTRUCTED IN ACCORDANCE WITH SPECIFICATIONS AND STANDARDS OF SECTION 351.0065,_ F.S. , AND CHAPTER 64E-6, F.A.C. DEPARTMENT APPROVAL OF SYSTEM DOES NOT GUARANTEE SATISFACTORY PERFORMANCE FOR ANY SPECIFIC PERIOD OF TIME. ANY CHANGE IN MATERIAL FACTS, WHICH SERVED AS A BASIS FOR ISSUANCE OF THIS PERMIT, REQUIRE THE APPLICANT TO MODIFY THE PERMIT APPLICATION. SUCH MODIFICATIONS MAY RESULT IN THIS PERMIT BEING MADE NULL AND VOID. ISSUANCE OF THIS PERMIT DOES NOT EXEMPT THE APPLICANT FROM COMPLIANCE WITH OTHER FEDERAL, STATE, OR LOCAL PERMITTING REQUIRED FOR DEVELOPMENT OF THIS PROPERTY. SYSTEM DESIGN AND SPECIFICATIONS % [ 900 ] GALLONS / GPD Septic new CAPACITY ] GALLONS / GPD N/A CAPACITY N [ ] GALLONS GREASE INTERCEPTOR CAPACITY [MAXIMUM CAPACITY SINGLE TANK:1250 GALLONS] IC= [ ] GALLONS DOSING TANK CAPACITY [ ]GALLONS @[ ]DOSES PER 24 HRS #IPumps [ ] D [ 334 ] SQUARE FEET Drainfield new SYSTEM R [ ] SQUARE FEET N/A SYSTEM A TYPE SYSTEM: [ ] STANDARD [ ] FILLED [x] MOUND • [ ] I CONFIGURATION: [ ] TRENCH [x] BED [ ] N F LOCATION OF BENCHMARK: orange spot NE corner of existing transformer pad elev 29.6?3? I ELEVATION OF PROPOSED SYSTEM SITE [ 13.00 ] [ INCHES FT ] [ ABOVE BELOW BENCHMARK/REFERENCE POINT E BOTTOM OF DRAINFIELD TO BE [ 12.001 [ INCHES FT ] [ABOVE BELOW BENCHMARK/REFERENCE POINT L D FILL REQUIRED: [ 19.001 INCHES EXCAVATION REQUIRED: [ 41.001 INCHES The system is sized for 1 bedrooms with a maximum occupancy of 2 persons(2 per bedroom),for a total estimated flow of ° 200 gpd. T The licensed contractor installing the system is responsible for installing the minimum category of tank in accordance with H s.64E-6.013(3)(0,FAC. E R loll No INA 7 SPECIFICATIONS BY: Brian J Ingrc3g TITLE: Environmental Speclali APPROVED BY: , LE: Environmental Specialist II St. Lucie CHD Brian J Ingr DATE ISSUED: 02/14/2017 EXPIRATION DATE: 08/14/2018 DE 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.003, FAC Page 1 of 3 v 1.1.4 AP1271797 SE1023032 .t .L NOTICE OF RIGHTS A party whose substantial interest is affected by this order may petition for an administrative hearing pursuant to sections 120.569 and 120.57, Florida Statutes. Such proceedings are governed by Rule 28-106, Florida Administrative Code. A petition for administrative hearing must be in writing and must be received by the Agency Clerk for the a Department, within twenty-one (21) days from the receipt of this order. The address of the Agency Clerk is 4052 Bald Cypress Way, BIN A-02, Tallahassee, Florida 32399. The Agency ` Clerk's facsimile number is 850-413-8743. Mediation is not available as an alternative remedy. Your failure to submit a petition for hearing within 21 days from receipt of this order will constitute a waiver of your right to an administrative hearing, and this order shall become a 'final order. Should this order become a final order, a party who is adversely affected by it is entitled to judicial review pursuant to Section 120.68, Florida Statutes. Review proceedings are governed by the Florida Rules of Appellate Procedure. Such proceedings may be commenced by filing one copy of a Notice of Appeal with the Agency Clerk of the Department of Health and a second copy, accompanied by the filing fees required by law, with the Court of Appeal in the appropriate District Court. The notice must be filed within 30 days of rendition of the final order. FILE COPY Al 4 APPLICATION- #:AP1271797 STATE OF FLORIDA PERMIT #:56-SF-1733732 DEPARTMENT OF HEALTH. c ' ' ONSITE SEWAGE TREATMENT" AND DISPOSAL SYSTEM DOCUMENT #:FI 1206116 ' y CONSTRUCTION .INSPECTION AND FINAL APPROVAL DATE PAID:06L29/2017 FEE PAID.:115.00 RECEIPT #:56-PID-3289221 APPLICANT: Larry Aitkens AGENT: Celentano Development Group PROPERTY ADDRESS: ' Lot 98 NaVion Rd Port.Saint Lucie, FL 34987 LOT: 98 BLOCK: SUBDIVISION: Treasure Coast Air Park ID#: 4224-501-0098-000-l' CHECKED [X] ITEMS ARE NOT IN COMPLIANCE WITH STATUTE OR RULE AND- MUST BE CORRECTED. TANK INSTALLATION SETBACKS [ ] [01'] TANK SIZE [1] 1090.00 [21 [ ] [271 SURFACE WATER 1;00+ FT [ ] [021 TANK ,MATERIAL Polyethylene [ ] [281 DITCHES FT [ ] [031 OUTLET DEVICE [ ] 12 9] PRIVATE WELLS 183 FT [ ] [041 MULTI--CHAMBERED [ Y N ] [ ] [30]' PUBLIC WELLS FT [ ] [05] OUTLET FILTER POlylok PL-68 [ ] [311 IRRIGATION' WELLS FT [ ] [061 LEGEND 1. 70-143-11DC4 2, [ ] [321 POTABLE WATER 20 FT [ ] [071 WATERTIGHT [ -] [33] BUILDING FOUNDATIONS 6 FT [ ] [081 LEVEL. [ ] [341 PROPERTY LINES FT' [ ] (09] DEPTH TO LID [ ] [35]1. OTHER. FT` DRAINFIELD INSTALLATION FILLED / MOUND SYSTEM [ ] [10] AREA [1] 408 [21 SQFT [ ] [361 'DRAINFIELD COVER [ ] [111 DISTRIBUTION BOX. HEADER x [ ] [371 SHOULDERS [ ] [12] NUMBER OF DRAINLINES 1. '6.00 2. [, ] [38] SLOPES [ ] [131 DRAINLINE SEPARATION [ ] [39] STABILIZATION 08/29/2018 [ ] [141 DRAINLINE SLOPE [ ] [15] DEPTH OF COVER ADDITIONAL INFORMATION [ ] [161 ELEVATION [ ABOVE / BELOW ]BM 10.00 [ ] [40], UNOBSTRUCTED AREA [ ] [:171 SYSTEM LOCATION [ ] [411 STORMWATER RUNOFF [ ] [181 DOSING PUMPS. [ ] [42] ALARMS [ ] [191 AGGREGATE SIZE [ ] [431. MAINTENANCE AGREEMENT [ ] (20] AGGREGATE EXCESSIVE FINES [ ] [44] BUILDING AREA f [ ] 1211 AGGREGATE DEPTH [ .] [451, LOCATION CONFORMS WITH SITE PLAN FILL / EXCAVATION MATERIAL [ ] [.4b] FINAL SITE GRADING [ ] [22] FILL AMOUNT [ '] [47] CONTRACTOR. (Cookes Eoyironmental SIN [ ] (23] FILL TEXTURE [ ] [48] OTHER INFILTRATOR Quick4EQ36(single c [ ] [24] EXCAVATION DEPTH ABANDONMENT [ ] [25] AREA REPLACED [ ] [4.9] TANK PUMPED [ ] j261 REPLACEMENT MATERIAL [ ] [50] TANK CRUSHED & FILLED Comments: Comments are on page 2. CONSTRUCTION [. APPROVED / St.Lucie CHD DATE: 04/13/2018 DISAPPROVED ]° Env ronmental Specialist I D a S May(Florida Department of Health FINAL SYSTEM C APPROVED / DISAPPROVED ]: St. Lucie CHI) DATE': 08/29/2018 Env ronmental Specialist 11 Br J Ingram(ENVIRONMENTAL HEALTH) (Explanation of Violations on following page) DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6..003, FAC Page 2 of 3 EH Database v 1.0.1 AP1271797 EID1733732 v APPLICATION #:AP1.271797 _9`' 'STATE OF FLORIDA� PERMIT #:56-SF-1733732 DEPARTMENT OF HEALTH Q ON91TE SEWAGE TREATMENT AND DISPOSAL SYSTEM DOCUMENT #:.F11:206116 'ry CONSTRUCTION INSPECTION AND FINAL APPROVAL DATE PAID:06/29/2017 FEE PAID. 115.00 RECEIPT #:56-PID-3289221 Violation Number Comment Comments The system is sized for 1 bedrooms with a maximum occupancy of 2 persons(2 per bedroom),for a total estimated flow of 200 gpd. New ST and DF installed 4x6 chambers long. Lid screwed down at time of inspection-CHECK FOR OUTLET FILTER AT FINAL INSPECTION.System ok to cover:.Contractor notified by phone.Well checked at time of inspection..Final required for mound system,final grading,and outlet filter. Final system approved.Contractor and'building department.emailed final approval. I DH 4016, 08/09 (Obsoletes all previous editions which may not be used) Incorporated: 64E-6.00.3, FAC Page 2 of 3 EH Database v 1.0.1 AP1271797 EID1733732