Loading...
HomeMy WebLinkAboutProduct Approval ` _ r M lY! M BCIS Home I Log In User Registration I Hot Topic Submit Surcharge I Stats&Facts I Publications I FBC Staff I BCIS Site Map I Links I Search b a Product Approval i USER:Public User ��Tec uarc�:s &Po�.rJkgiL;;P;n Product Approval Menu>Product or Application Search>Application List>Application Detail • FL# FL2774-RB Application Type Editorial Change 3 (+ram z0 17 Code Version 2014 Application Status Approved *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary. 60 Comments Archived Product Manufacturer United Structures of America, Inc. Address/Phone/Email 1912 Buschong Houston,TX 77039 (281)442-8247 Ext 235 anan@usabldg.com Authorized Signature Anan Almughrabi anan@usabldg.com Technical Representative Anan Almughrabi Address/Phone/Email 1912 Buschong Houston TX 77039 (281)442-8247 Ext235 anan@usabldg.com Quality Assurance Representative Thomas Escobar Address/Phone/Email 1912 Buschong Houston,TX 77039 (281)442-8247 engr@usabidg.com Category Roofing Subcategory Metal Roofing Compliance Method Certification Mark or Listing Certification Agency UL LLC Validated By UL LLC Referenced Standard and Year(of Standard) Standard Year Underwriters Laboratories UL 580 2006 Equivalence of Product Standards Certified By Approved Certification Agency FL2774 R8 Eouiv UL-031116.1.odf ; FILE , Product Approval Method Method 1 Option A Date Submitted 11/10/2016 Date Validated 01/04/2017 Date Pending FBC Approval Date Approved 01/05/2017 Summary of Products FL# Model,Number or Name Description 2774.1 Guardian I or II Standing Seam Metal Roof Panel Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2774 R8 C CAC CONST NO. 180B TGKX.180B.pdf Approved for use outside HVHZ:Yes FL2774 R8 C CAC CONST NO. 205A TGKX.205A.pdf Impact Resistant: No FL2774 R8 C CAC CONST NO. 308B TGKX.308Bpdf Design Pressure: +N/A/-52.5 FL2774 R8 C CAC CONST NO. 534 TGKX.534.pdf Other: Minimum Roof Slope = 1/4:12 This product is not FL2774 R8 C CAC CONST NO. 536 TGKX.536.pdf approved for High Velocity Hurricane Zones. Design Pressure FL2774 R8 C CAC TJPV.R9610 CERT.odf varies depending on panel gage and span. FL2774 R8 C CAC USA UL Insp Dec 2011.pdf Quality Assurance Contract Expiration Date 12/31/2019 Installation Instructions FL2774 R8 II Guardian.InstaIlati on.Manual.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2774.2 Guardian-Lok Standing Seam Metal Roof Panel Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2774 R8 C CAC CONST NO. 180C TGKX.180C.pdf Approved for use outside HVHZ:Yes FL2774 R8 C CAC CONST NO. 287 TGKX.287.pdf Impact Resistant: No FL2774 R8 C CAC CONST NO. 538 TGKX.538.pdf Design Pressure: +N/A/-52.5 FL2774 R8 C CAC CONST NO. 539 TGKX.539.odf Other: Minimum Roof Slope = 1/4:12 This product is not FL2774 R8 C CAC TJPV.R9610 CERT.odf approved for High Velocity Hurricane Zones. Design pressure FL2774 R8 C CAC USA UL Inso Dec 2011.odf varies depending on panel gage and span. Quality Assurance Contract Expiration Date 12/31/2019 Installation Instructions FL2774 R8 II Guardia nLok.Instal Iation.Manual.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2774.3 Supreme-Lok Standing Seam Metal Roof Panel Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2774 R8 C CAC CONST NO. 176 TGKX.176.pdf Approved for use outside HVHZ:Yes FL2774 R8 C CAC CONST NO. 180 TGKX.180.odf Impact Resistant: No FL2774 R8 C CAC CONST NO. 238B TGKX.23813.pdf Design Pressure: +N/A/-52.5 FL2774 R8 C CAC CONST NO. 437 TGKX.437.pdf Other: Minimum Roof Slope = 1/4:12 This product is not FL2774 R8 C CAC TJPV.R9610 CERT.pdf approved for High Velocity Hurricane Zones. Design Pressure FL2774 R8 C CAC USA UL Insp Dec 2011.odf varies depending on panel gage and span. Quality Assurance Contract Expiration Date 12/31/2019 Installation Instructions FL2774 R8 II Supreme Lok.Installation.Manual.pdf Verified By: Window and Door Manufacturers Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2774.4 Sure-Lok Standing Seam Metal Roof Panel Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2774 R8 C CAC CONST NO. 176 TGKX.176.pdf Approved for use outside HVHZ:Yes FL2774 R8 C CAC CONST NO. 180 TGKX.180.pdf Impact Resistant: No FL2774 R8 C CAC CONST NO. 238B TGKX.238B.pdf Design Pressure: +N/A/-52.5 FL2774 R8 C CAC CONST NO. 437 TGKX.437.pdf Other: Minimum Roof Slope = 1/4:12 This product is not FL2774 R8 C CAC TJPV.R9610 CERT.odf approved for High Velocity Hurricane Zones. Design Pressure FL2774 R8 C CAC USA UL Inso Dec 2011.pdf varies depending on panel gage and span. Quality Assurance Contract Expiration Date 12/31/2019 Installation Instructions FL2774 R8 II SureLok.Installation.Manual.lid f Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 2774.5 U.S.A.R. Through-fastened Metal Roof Panel Limits of Use Certification Agency Certificate Approved for use in HVHZ: No FL2774 R8 C CAC CONST NO. 161 TGKX.161.pdf Approved for use outside HVHZ:Yes FL2 74 R8 C CAC CONST NO. 167 TGKX.167. df .n PP d 7 P Impact Resistant: No FL2774 R8 C CAC TJPV.R9610 CERT.Ddf Design Pressure: +N/A/-52.5 FL2774 R8 C CAC USA UL Insp Dec 2011.pdf Other: Minimum Roof Slope = 1/2.12 This product is not Quality Assurance Contract Expiration Date approved for High Velocity Hurricane Zones. Design Pressure 12/31/2019 varies depending on panel gage and span. Installation Instructions FL2774 R8 II PBR Installation Instructions.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Back Next Contact Us::2601 Blair Stone Road,Tallahassee FL 32399 Phone:850-487-1824 The State of Florida is an AA/EEO employer.Copyright 2007-2013 State of Florida. ::Privacy Statement::Accessibility Statement::Refund Statement Under Florida law,email addresses are public records.If you do not want your e-mail address released in response to a public-records request,do not send electronic mail to this entity.Instead,contact the office by phone or by traditional mail.If you have any questions,please contact 850.487.1395.-Pursuant to Section n 455.275(1),Florida Statutes,effective October 1,2012,licensees licensed under Chapter 455,F.S.must provide the Department with an email address if they have one.The emalls provided may be used for official communication with the licensee.However email addresses are public record.If you do not wish to supply a personal address,please provide the Department with an email address which can be made available to the public To determine If you are a licensee under Chapter 455,F.S.,please dick here. Product Approval Accepts: Y � ��' sCAeck Credit Card Safe PANEL &TRIM Page No. 7-21 CONNECTIONS Rev. 1 Date 11-1-91 12" 1211 12" 91/2" 21/21 91/2„ 21/2„ 91/2„ 21/2" MEMBER SCREW LOCATION Detail "A" (ALL MEMBERS EXCEPT AS NOTED) 12" 12" 12" 21�2,' 7, 21/2" 21/2" 7" 21/21I 21/2," 7„ 21/2„ lo, MEMBER SCREW LOCATION Detail `'A"' (PEAK PURLIN, EAVE STRUT, AND PANEL END LAPS) Stitch Screws At Continuous Tape Sealer 20"On Center 3/8"x 3/32"(Standard) 1"x 3/32"(Optional) Extended Leg On "PBR"Panel Only DETAIL"A" Member ScrewsPanelsJrContinuous Tape Seale SATISFY UL-90 3/8"x 3/32°(Standard) 2" 4„ + REQUIREMENT FOR ROOF. 1"x 3/32"(Optional) Puldn Be Specified On Order) SECTION THRU PEAK PURLIN AND PANEL END LAPS "PBR" AND "R" PANEL ROOF 0 66PBR„ & 66R„ ROOF PANEL MASTER ERECTION DETAILS SCREW SPACING Technical information contained herein is subject to change without notice. UNITED STRUCTURES OF AMERICA i PANEL &TRIM Page No. 7-23 CONNECTIONS Rev. 0 Date 12-31-87 Roof. Steel Line Stitch Screws At 12" On Rake Trim Center With Continuous Tape (MK—RTO1) Sealant Under Trim Roof Panel Member Screws Stitch Screws i i Sheeting Angle At 12" On Center i Outside Closure N_Purlin Wall Panel (Beyond) RAKE DETAIL WITH SHEETED ENDWALL Roof Steel Line Stitch Screws At 12" On Rake Trim Center With Continuous Tape (MK—RT01) Sealant Under Trim Roof Panel Member Screws r At 24" On Center i Sheeting Angle Stitch Screws At 12" On Center _Z 2urlin (Beyond) Rake Spacer Member- Screws (MK—PF01) U114 At 24" On Center RAKE DETAIL WITH OPEN ENDWALL 17, MASTER ERECTION DETAILS ®s RAKE DETAIL WITH SHEETED OR OPEN ENDWALL Technical information contained herein is subject to change without notice. UNITED STRUCTURES of AMERICA I PANEL & TRIM Page No. 7-24 CONNECTIONS Rev. 0Date 12-31-87 X Purlin Extension Canopy Bldq Steel Line Rake Trim Stitch Screws At 12" On (MK—RT01) 3° Center With Continuous Tape Sealant Under Trim Roof Panel Member Screws r -- - -- - -- - -- - ----- At 24" On Center I I Sheeting Angle Stitch Screws At Stitch Screws 1 I 12" On Center At 12" On Center 1 Purlin (Beyond) I Rake Spacer —Member Screws (MK—PF01) Closure Trim (MK—PT01) 1'4 Member Screws Stitch Screws At 12" On Center Sheeting At 2411 On Center Angle Outside Closure (*)Standard Dimensions RAKE DETAIL WITH PURLIN Wall Panel 3'-3" or 5'-3" EXTENSION CANOPY WITHOUT SOFFIT Purlin Extension Canopy ,Bldg Steel Line Rake Trim Stitch Screws At 12" On 3" Center With Continuous Tape (MK—RT01) Sealant Under Trim Roof Panel Member Screws At 24" On Center I Sheeting Angle I Stitch Screws At Stitch Screws I 12" On Center At 121f On Center I Purlin (Beyond) I Rake Spacer High Rib Soffit Panel Sheeting (MK—PC01) 1,41 34 Closure Trim (MK—LT01) Angle Outside Closure 2h4' Member Screws (*�tandard Dimensions High Rib I 3'-3" or 5'-3" RAKE DETAIL WITH PURLIN Wall Panel EXTENSION CANOPY WITH SOFFIT MASTER ERECTION DETAILS RAKE DETAIL WITH tm PURLIN EXTENSION Technical information contained herein is subject to change without notice. UNITED STRUCTURES of AMERICA PANEL & TRIM Page No. 7-25 CONNECTIONS Rev. 0 Date 12-31-87 Attach To Eave Strut With Pop Rivets At 3'-0 On Center. Inside Closure 4„ Cn Member Screws U Member Screws Inside Closure Stitch Screws Stitch Screws at 6" On Center Roof Panel At 12" On Center Roof Panel Panel Cap Trim Member Screws Panel Cap Trim I Member Screws (MK—ET02) ( ) (MK—ET02) (*) Gutter (MK-EG_) Eave Trim (MK—ET_) I Eave Strut " I Eave Strut C ter_ Stitch Screws At 12 On en Wall Panel Wall Panel LOW EAVE DETAIL WITH LOW EAVE DETAIL WITH EAVE GUTTER SCULPTURED EAVE TRIM (SHEETED SIDEWAW (SHEETED SIDEWALLI Outside Closure Stitch Screws At With Tape Sealer 6" 12" On Center On .Bottom Member Screws Inside Closure Eove Trim (MK—HT--) — Member Screws Roof Panel Roof Panel Member Screws Eave Trim (MK—ET05) Member Screws Stitch Screws At r 12" On Center I Stitch Screws At 12" On Center I Eave Strut Eave Strut Outside Closure I Wall Panel Wall Panel LOW EAVE DETAIL WITH HIGH EAVE DETAIL WITH SIMPLE EAVE TRIM SCULPTURED EAVE TRIM (SHEETED SIDEWAW (SHEETED SIDEWALL) MASTER ERECTION DETAILS f EAVE DETAILS WITH SHEETED SIDE WALL Technical information contained herein is subject to change without notice. UNITED STRUCTURES of AMERICA PANEL &TRIM Page No. 7-26 CONNECTIONS Rev. 0 Date 12-31-87 4 4„ Inside Closure 6„ Member Screws Member Screws Inside Closure Stitch Screws Stitch Screws at 6" On Center Roof Panel At 12" On Center Roof Panel Member Screws At Member Screws At 12" On Center 24" On Center Gutter (MK-EG__) Eave Trim (MK-ET—) Eave Strut Eave Strut Eave Spacer (MK-E501) Stitch Screws At 1,� 12" On Center 1'4 4 Eave Spacer (MK-ES01) LOW EAVE DETAIL WITH LOW EAVE DETAIL WITH EAVE GUTTER SCULPTURED EAVE TRIM (OPEN SIDEWALa (OPEN SIDEWQ 6" Outside Closure Screws Stitch Screws At With Tape Sealer Inside'Clo,,ret 12" On Center On Bottom Eave Trim (MK-HT—) — —— oof Panel Member Screws At Screws At 24" On Center Roof Panel Eave Trim (MK-ET05) enter Member Screws Stitch Screws At Stitch Screws At 12" On Center 12" On Centerave Strut Eave Spacer (MK-ESOI) Eave Spacer (MK-HT02) Eave Strut Member Screws At 24" On Center LOW EAVE DETAIL WITH HIGH EAVE DETAIL WITH SIMPLE EAVE TRIM SCULPTURED EAVE TRIM (OPEN SIDEWALL) (OPEN SIDEWALL) MASTER ERECTION DETAILS EAVE DETAILS WITH OPEN SIDEWALL Technical information contained herein is subject.to change without notice. UNITED STRUCTURES OF AMERICA I PANEL &TRIM Page No. 7-27 CONNECTIONS Rev. 0 Date 12-31-87 Member Screws At Member Screws At 6" On Center 12" On Center == Stitch Screws At 6" on Center Roof Panel Inside Closure Cutter (MK—EC_) Eave Trim Eave Channel (MK—ET05) Eave Strut Canopy Eave Trim Stitch Screws At (MK—CF_) I I 12" On Center (- Return Downspout i ——————— — (MK—RS_) - 234 T Member Screws At 6 On Center Member Screws 12" On Center I Wall Panel I Canopy Eave Trap (MK—CF� Eave Canopy Member Screws At SECTION THRU EAVE CANOPY � Standard Dimensions 12" On Center CANOPY WITH EAVE TRIM WITHOUT SOFFIT S-0" or 5'-0" Inside Closure Member Screws At Stitch Screws At Member Screws At 12" On Center 6" on Center 6" On Center Roof Panel Cutter (MK—EC_) Outside Closure Eave Strut Canopy Eave Trim Eave Channel Soffit Panel (MK—CS--) I i Stitch Screws At Return Downspout -t — ———— Soffit Trim (MK—ST01) 12" On Center (MK—RS_) Member Screws At ———— Inside Closure 234 1' 6* On Center Member Screws At I Wall Panel 12" On Center Canopy Eave Trim Soffit Panel (MK—CS_) Eave Canopy Member Screws At SECTION THRU EAVE CANOPY 12" On Center CANOPY WITH EAVE TRIM WITH SOFFIT M STANDARD CANOPY DETAILS ASTER ERECTION DETAILS �. W/ OR W/O SOFFIT Technical information contained herein is subject to change without notice. UNITED STRUCTURES OF AMERICA