HVAC Load Calculations
' PEl;:+fi ITT INC,
• for St. Lucie County, FL
Renar Homes
R""VAC
HVAC LoAns
Prepared By:
Preferred Air Conditioning&Mechanical
1643 Donna Road
West Aplm Beach, FI.33409
Saturday,May 20,2017
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D. FILE COPY
,
Rfiwac=.Resideiitia f&'li Light Commercial HV "g AC loads „ EMte Software Development,Inc:
Preferred AirConditiomng&Mech r 9316 Windrrft Circle;
West Palm Beach,FL 33409: Noe 2
Project Report
General Pro'ect Information
Project Title: 9316 Windrift Circle
Project Date: Wednesday, May 17, 2017
Client Name: Renar Homes
Company Name: Preferred Air Conditioning&Mechanical
Company Address: 1643 Donna Road
Company City: West Aplm Beach, FI. 33409
Company E-Mail Address:
Company Website: GETCOLD.NET
De'si n Data -
Reference City: Fort Pierce, Florida
Building Orientation: House faces North
Daily Temperature Range: Medium
Latitude: 27 Degrees
Elevation: 25 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 42 39.4 n/a n/a 70 n/a
Summer: 90 78 59% 50% 75 61
Check Fi ores
Total Building Supply CFM: 812 CFM Per Square ft.: 0.385
Square ft. of Room Area: 2,108 Square ft. Per Ton: 531
Volume(ft'): 16,862
Buildm Loads
Total Heating Required Including Ventilation Air: 32,728 Btuh 32.728 MBH
Total Sensible Gain: 25,676 Btuh 54 %
Total Latent Gain: 21,915 Btuh 46 %
Total Cooling Required Including Ventilation Air: 47,590 Btuh 3.97 Tons(Based On Sensible+ Latent)
Notes . �..°-. ,-'�' � - _ ., _...;- � �• - - - ;
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\renar sales.rh9 Saturday, May 20, 2017, 11:29 AM
Rhvac Residential Light;Commercial HVAC Loads Elite Software Development;Inc:
Preferred Air Conditioning&.Mech 9316 Wmil Circle'
West Palm Beach,FL 33409. Pa e3
Miscellaneous Report
System 1=Main Outdoor Outdoor Outdoor Indoor Indoor Grains:;
Ir ut Data::: D .UIb - Wet;�Bulbr R-1 Hum;; Rel Hum = D Bulb_ Difference
Winter: 42 39.4 80% n/a 70 n/a
Summer: 90 78 59% 50% 75 61.09
System 2 Sales Outdoor Outtloor Outdoor Indoor.: Indoor. Gr,'ams;
Iri `ut,Data,: 13 .Bulb UVef_Bulb ' .-R' Hum:, Rel Hum D . Bulb,: Difference'.
Winter: 42 39.4 80% n/a 70 n/a
• Summer: 90 78 59% 50% 75 61.09
Duct Sizin `Iri uts- •., " , - •- -
Main Trunk Runouts
Calculate: Yes Yes
Use Schedule: Yes Yes
Roughness Factor: 0.00300 0.01000
Pressure Drop: 0.1000 in.wg./l00 ft. 0.1000 in.wg./100 ft.
Minimum Velocity: 650 ft./min 460 ft./min
Maximum Velocity: 900 ft./min 750 ft./min
Minimum Height: 0 in. 0 in.
Maximum Height: 0 in. 0 in.
Winter Summer
Infiltration Specified: 0.438 AC/hr 0.397 AC/hr
123 CFM 111 CFM
Infiltration Actual: 0.000 AC/hr 0.000 AC/hr
Above Grade Volume: X 16,862 Cu.ft. X 16,862 Cu.ft.
0 Cu.ft./hr 0 Cu.ft./hr
X 0.0167 X 0.0167
Total Building Infiltration: 0 CFM 0 CFM
Total Building Ventilation: 475 CFM 475 CFM
--System 1—
Infiltration &Ventilation Sensible Gain Multiplier: 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference)
Infiltration&Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference)
Infiltration &Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference)
Winter Infiltration Specified: 0.110 AC/hr(26 CFM), Construction: Tight
Summer Infiltration Specified: 0.060 AC/hr(14 CFM), Construction: Tight
---System 2---
Infiltration &Ventilation Sensible Gain Multiplier. 16.49 = (1.10 X 0.999 X 15.00 Summer Temp. Difference)
Infiltration &Ventilation Latent Gain Multiplier: 41.50 = (0.68 X 0.999 X 61.09 Grains Difference)
Infiltration &Ventilation Sensible Loss Multiplier: 30.77 = (1.10 X 0.999 X 28.00 Winter Temp. Difference)
Winter Infiltration Specified: 2.000 AC/hr(98 CFM)
Summer Infiltration Specified: 2.000 AC/hr(98 CFM)
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\renar sales.rh9 Saturday, May 20, 2017, 11:29 AM
i
,
Rhvac-ResidentialA Light Commercial RVAC.Loads.,: Elite Software Development,Inc.
Preferred Ai� onditionrig&Mech `' 9316 Windrift Circle
West Palm Beach,.FL.33409 `' . . ,. Paq e 4
Loan! Preview Report
: Mini Min Sys Sys Sys
Hasl Net, ft. Sen; LatiI Netl Sen Htg Clg Htg, CigI Act Duct
Scope AED oss IIII Ton! /Ion Area; Gains Gainl Gain L Size
CFM CFM CFM! CFMI CFM
Building 3.11 678 2,108 22,750 14,549 37,299 27,266 354 1,035 354 1,035 1,035
System 1 Main No 2.11 824 1,742 15,675 9,701 25,376 17,972 234 713 234 713 713 10x14
Zone 1 1,742 15,675 9,701 25,376 17,972 234 713 234 713 713 10x14
1-M Wic 61 387 0 387 1,186 15 18 15 18 18 1-4
2-M Bath 78 608 0 608 770 10 28 10 28 28 1-4
3-M Bedroom(2) 213 2,772 4,550 7,323 4,365 57 126 57 126 126 1-7
_ 5-Den!Br 147 696 200 896 1,040 14 32 14 32 32 1-4
6-Br2 143 699 200 899 1,001 13 32 13 32 32 1-4
7-Kitchen 170 4,022 0 4,022 1,463 19 183 19 183 183 1-8
8-Laundry 63 1,217 0 1,217 481 6 55 6 55 55 1-4
9-Living 385 620 0 620 345 4 28 4 28 28 1-4
10-Bath 64 417 0 417 512 7 19 7 19 19 1-4
11-Bedroom 3 164 974 200 1,174 1,329 17 44 17 44 44 1-4
12-Foyer 42 491 0 491 1,115 14 22 14 22 22 1-4
System 2 Sales Yes 0.99 368 366 7,075 4,848 11,923 9,294 121 322 121 322 322 8x8
Zone 2 366 7,075 4,848 11,923 9,294 121 322 121 322 322 8x8
13-Sales 366 7,075 4,848 11,923 9,294 121 322 121 322 322 1-10
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\renar saies,rh9 Friday, May 19, 2017, 1:48 PM
Rhvac-Residential&Light.Commercial HyAC Loatls': Elite Softwate Development,'Inc..
Pteferred'Air.Condltloning&Mech ' .9316 Windrift Circle
West Palm Beach, RL 33409 „; ;' Page 5
Duct Size Preview
Room or ;Source ; Minimum Maximum! Rough. Design SP Duct Duct; Htg Clg + Act. Duct
Duct Name II Velocity Velocity- Factor'L/1001 Loss} Velocity Length; Flow ..Flow Flow�.__Size._-
_....._._..----_-._�_...-__......-^..___._.__�i___�._J _-
System 1
Supply Runouts
Zone 1
1-M Wic Built-In 450 750 0.01 0.1 201.6 15 ::18 18 1-4
2-M Bath Built-In 450 750 0.01 0.1 317.1 10 28# 28 1-4
3-M Bedroom Built-In 450 750 0.01 0.1 471.9 57> 126 126 1-7
4-Family Built-in 450 750 0.01 0.1 0 0 0 0 0_0
5-Den/Br Built-In 450 750 0.01 0.1 362.8 14 P :32 32 1-4
6-Br2 Built-In 450 750 0.01 0.1 364.4 13'^f32 32 1-4
7-Kitchen Built-In 450 750 0.01 0.1 524.2 19 r 183' 183 14
8-Laundry Built-In 450 750 0.01 0.1 634.3 64"55 55 1-4
9-Living Built-In 450 750 0.01 0.1 323.4 4 ". `;28 28 1-4
10-Bath Built-In 450 750 0.01 0.1 217.4 7 `'' 9 19 1-4
11-Bedroom3 Built-In 450 750 0.01 0.1 507.7 17 °: :.w.44 44 1-4
12-Foyer Built-In 450 750 0.01 0.1 256.2 14>^'="s=22. 22 1-4
Other Ducts in System 1 _
Supply Main Trunk Built-In 650 900 0.003 0.1 733.5 234 713 10x14
System 2
Supply Runouts
Zone 2
13-Sales Built-in 450 750 0.01 0.1 690.2 121 j'>322 322 1-10
Other Ducts in System 2
Supply Main Trunk Built-In 650 900 0.003 0.1 724.2 121 322 8x8
Summary
System 1
Heating Flow: 234
Cooling Flow: 713
System 2
Heating Flow: 121
Cooling Flow: 322
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\renar sales.rh9 Friday, May 19, 2017, 1:48 PM
Rhvac Residen6a1:8 Light Co.mmerelal.HVAC Loads pment,lnc:
Elite Software t)epelo
Prefened Aii Conditiornng&Mech 9316 Wmd_rrf_f Circle
West Palm Beach,FL 33409. Page 6
Total Building Summary Loads
Component Area Sen Lat Sen>. Total°
;pesc�i tion Quan, Loss Gain, Gam_. Gain
RENAR gGL BK Glazing-RENAR SINGLE HUNG, u 13.3 175 0 358 358
value 0.47, SHGC 0.24
RENAR SGH: Glazing-RENAR SINGLE HUNG, u-value 6.7 114 0 94 94
0.61, SHGC 0.23
RENAR SGH: Glazing-RENAR SINGLE HUNG, u-value 27.1 411 0 745 745
0.54, SHGC 0.25
RENAR FIXED: Glazing-RENAR SINGLE HUNG, u-value 7.8 103 0 95 95
0.47, SHGC 0.24
RENAR SGH: Glazing-RENAR SINGLE HUNG, u-value 70.8 2,142 0 1,878 1,878
1.08, SHGC 0.49
11 P: Door-Metal-Polyurethane Core 20 162 0 151 151
13A-4ocb:Wall-Block, board insulation only, R-4 board 1577.5 6,534 0 3,573 3,573
insulation, open core, brick finish
1613-30: Roof/Ceiling-Under Attic with Insulation on Attic 1518.5 1,361 0 2,430 2,430
Floor(also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-30 insulation
16BR-30: Roof/Ceiling-Under Attic with Insulation on Attic 425.3 382 0 680 680
Floor(also use for Knee Walls and Partition
Ceilings), Unvented Attic with Radiant Barrier, Any
Roofing Material,Any Roof Color, R-30 insulation
22A-ph: Floor-Slab on grade, No edge insulation, no 177 6,727 0 0 0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure: 18,111 0 10,004 10,004
People: 11 2,200 2,530 4,730
Equipment: 0 5,200 5,200
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0
Ventilation: Winter CFM:475, Summer CFM:475 14,617 19,715 7,830 27,545
AED Excursion: _ _ 0_ 0 111
Total Building Load Totals: 32,728 21,915 25,676 47,590
Check Figures
Total Building Supply CFM: 812 CFM Per Square ft.: 0.385
Square ft. of Room Area: 2,108 Square ft. Per Ton: 531
Volume(ft'): 16,862
Buildin Loads - -
Total Heating Required Including Ventilation Air: 32,728 Btuh 32.728 MBH
Total Sensible Gain: 25,676 Btuh 54 %
Total Latent Gain: 21,915 Btuh 46 %
Total Cooling Required Including Ventilation Air: 47,590 Btuh 3.97 Tons(Based On Sensible+ Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\renar sales.rh9 Saturday, May 20,2017, 11:29 AM
Rhvac Residential Ught Commercial HVAC Loads elopment,lnc
Preferretl Air Conditioning&.Mech
Elite Software Dev
9316.Windnft Circle
�'VV6st.P.alm Beach,FL,33409.....
'Page-7-
[—Building Pie Chart
Floor 21%
°10 Ventilation 45%
Building Roof 5
Loss
32,728
Btuh
j
4y
k
Wall 20%
Door 0%
Glass 9%
i
Roof 7% ED Excursion 0%
Wall 8%
Glass 7/o\
Door 0%
Building
Gain People 10% k
47,590
Btuh
Ventilation 58%
Equipment 11%
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\renar sales.rh9 Saturday, May 20, 2017, 11:29 AM
Rhvac Residential&Light Commercial HVAC Loads Elite Software Development,inc.
Preferred Air Conditiornng 8 Mech em 9316 Wmdri t'0i 616,
West,Palm`Beach,'FL 3U69 Pa e 9
rSystem 2 Sales Summary Loads
Component Area - Sen Lat: Sen Total
<..
Descn tlon = Quan Loss Gain Game
RENAR SGH: Glazing-RENAR SINGLE HUNG, u-value 70.8 2,142 0 1,878 1,878
1.08, SHGC 0.49
13A-4ocb: Wall-Block, board insulation only, R-4 board 390.5 1,618 0 884 884
insulation, open core, brick finish
1613-30: Roof/Ceiling-Under Attic with Insulation on Attic 365.7 328 0 585 585
Floor(also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-30 insulation
22A-ph: Floor-Slab on grade, No edge insulation, no 58 2,205 0 0 0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure: 6,293 0 3,347 3,347
People: 4 800 920 1,720
Equipment: 0 1,200 1,200
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration:Winter CFM: 0, Summer CFM: 0 0 0 0 0
Ventilation: Winter CFM: 175, Summer CFM: 175 5,385 7,263 2,885 10,148
System 2 Sales Load Totals: 11,678 8,063 8,352 16,415
Supply CFM: 249 CFM Per Square ft.: 0.680
Square ft. of Room Area: 366 Square ft. Per Ton: 267
Volume(fP): 2,926
-
Total Heating Required Including Ventilation Air: 11,678 Btuh 11.678 MBH
Total Sensible Gain: 8,352 Btuh 51 %
Total Latent Gain: 8,063 Btuh 49 %
Total Cooling Required Including Ventilation Air: 16,415 Btuh 1.37 Tons(Based On Sensible+ Latent)
Notes v _
r
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\renar sales.rh9 Saturday, May 20, 2017, 11:29 AM
M44c Residential&Light Commercial HVAC Loads.., Elite Software Development,Inc.
Preferred Air Conditioning&Mech 9316 Windnft Circle
West Palm Beach,FL:33409I% Pe`a 10
4�quipment Data - System 1 - Main
Cooling
System Type: Air Source Heat Pump
Outdoor Model: CH14NB036*0**B*
Indoor Model: FB4CNP042L
Tradename: CARRIER AIR CONDITIONING
Outdoor Manufacturer: CARRIER AIR CONDITIONING
Description: Air Source Heat Pump
' AHRI Reference No.: 9162515
Capacity: 34200
Efficiency: 14.5 SEER
Heating
System Type: Air Source Heat Pump
Model: CH14NB036*0**B*
Tradename: CARRIER AIR CONDITIONING
Manufacturer: CARRIER AIR CONDITIONING
Description: Air Source Heat Pump
Capacity: 33800
Efficiency: 8.2 HSPF
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 ProjectsVenar sales.rh9 Saturday, May 20, 2017, 11:29 AM
Rhvac Pesidenttai&Light Commercial HVAC Loads Elite Software Development,Irtc.
Preferred MmConditiornng&Mkh _ 9316 Windriff Circle
West Palm BeacFi,FL 334U9 .Pa 611
Equipment Data - S stem 2 - Sales
Cooling
System Type: Air Source Heat Pump
Outdoor Model: MUZ-GE18NA-1
Indoor Model: MSZ-GE18NA
Tradename: MR. SLIM
• Outdoor Manufacturer: MITSUBISHI ELECTRIC COOLING&HEATING
Description: Air Source Heat Pump
AHRI Reference No.: 4939870
Capacity: 17200
Efficiency: 19.2 SEER
Heating
System Type: Air Source Heat Pump
Model: MUZ-GE18NA-1
Tradename: MR. SLIM
Manufacturer: MITSUBISHI ELECTRIC COOLING& HEATING
Description: Air Source Heat Pump
Capacity: 21600
Efficiency: 10 HSPF
This system's equipment was selected in accordance with ACCA Manual S.
Manual S equipment sizing data: SODB: 90F, SOWB: 78F, WODB: 42F, SIDB: 75F, SIRH: 50%, WIDB: 70F, Sen. gain:
8,352 Btuh, Lat. gain: 8,063 Btuh, Sen. loss: 11,678 Btuh, Entering clg. coil DB: 85.617, Entering clg. coil WB: 73.9F,
Entering htg. coil DB: 10.1 F, Clg. coil TD: 20F, Htg. coil TD: 70F, Req. c1g. airflow:249 CFM, Req. htg. airflow: 82 CFM
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\renar sales.rh9 Saturday, May 20, 2017, 11:29 AM
Rhvac Rssidenhal 8 Light Commerc141 HVAC Loads Elite Software Development,lnc:
Preferred Air Condittornng&Mech � 9316 Windrift Circle
West Palm Beacfi,FL'.33409 Ra`a 12
S stem 9, Zone 9 Summary Loads (Average Load Procedure for Rooms)
Component Area Sen Lat Sen 1 otak
Descn tior _ = Quan Loss Gain Gam.:'- Gam'
RENAR gGL BK: Glazing-RENAR SINGLE HUNG, u- 13.3 175 0 358 358
value 0.47, SHGC 0.24
RENAR SGH: Glazing-RENAR SINGLE HUNG, u-value 6.7 114 0 94 94
0.61, SHGC 0.23
RENAR SGH: Glazing-RENAR SINGLE HUNG, u-value 27.1 411 0 745 745
_ 0.54, SHGC 0.25
RENAR FIXED: Glazing-RENAR SINGLE HUNG, u value 7.8 103 0 95 95
0.47, SHGC 0.24
11 P: Door-Metal- Polyurethane Core 20 162 0 151 151
13A-4ocb: Wall-Block, board insulation only, R-4 board 1187 4,916 0 2,689 2,689
insulation, open core, brick finish
166-30: Roof/Ceiling-Under Attic with Insulation on Attic 1152.8 1,033 0 1,845 1,845
Floor(also use for Knee Walls and Partition
Ceilings),Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-30 insulation
16BR-30: Roof/Ceiling-Under Attic with Insulation on Attic 425.3 382 0 680 680
Floor(also use for Knee Walls and Partition
Ceilings), Unvented Attic with Radiant Barrier, Any
Roofing Material,Any Roof Color, R-30 insulation
22A-ph: Floor-Slab on grade, No edge insulation, no 119 4,522 0 0 0
insulation below floor, any floor cover, passive, heavy
moist soil
Subtotals for structure: 11,818 0 6,657 6,657
People: 7 1,400 1,610 3,010
Equipment: 0 4,000 4,000
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration:Winter CFM: 0, Summer CFM_0 _ _ 0 _ _ 0 0 0
System 1, Zone 1 Load Totals: 11,818 1,400 12,378 13,778
Check Fi.u4es
Supply CFM: 563 CFM Per Square ft.: 0.323
Square ft. of Room Area: 1,742 Square ft. Per Ton: 1,517
Volume(ft'): 13,936
Zone
Total Heating Required: 11,818 Btuh 11.818 MBH
Total Sensible Gain: 12,378 Btuh 90 %
Total Latent Gain: 1,400 Btuh 10 %
Total Cooling Required: 13,778 Btuh 1.15 Tons(Based On Sensible+ Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\renar sales.rh9 Saturday, May 20, 2017, 11:29 AM
Rhvac Resideat�a!`&L►gt►t COmmerCial HVAC Loads Elite SoElware Development,tic
Preferred it Conditioning&Mech
"� ,, ndP 0
e13._
9 316 Wi
West Palm'Beach,FL 334U9.
System 2, Zone 2 Summary Loads (Average Load Procedure for Rooms)
Component Area Sen Lat Sen
Description , _Quan- Loss Gain Garr.:_
RENAR SGH: Glazing-RENAR SINGLE HUNG, u-value 70.8 2,142 0 1,878 1,878
1.08, SHGC 0.49
13A-4ocb:Wall-Block, board insulation only, R-4 board 390.5 1,618 0 884 884
insulation, open core, brick finish
• 1613-30: Roof/Ceiling-Under Attic with Insulation on Attic 365.7 328 0 585 585
Floor(also use for Knee Walls and Partition
Ceilings),Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal,Tar and Gravel or
Membrane, R-30 insulation
22A ph: Floor-Slab on grade, No edge insulation, no 58 2,205 0 0 0
insulation below floor, any floor cover, passive, heavy
_ moist soil _ __ _
Subtotals for structure: 6,293 0 3,347 3,347
People: 4 800 920 1,720
Equipment: 0 1,200 1,200
Lighting: 0 0 0
Ductwork: 0 0 0 0
Infiltration: Winter CFM: 0, Summer CFM: 0 0 0 0 0
System 2, Zone 2 Load Totals: 6,293 800 5,467 6,267
Supply CFM: 249 CFM Per Square ft.: 0.680
Square ft. of Room Area: 366 Square ft. Per Ton: 700
Volume(ft3): 2,926
Zone Loads
Total Heating Required: 6,293 Btuh 6.293 MBH
Total Sensible Gain: 5,467 Btuh 87 %
Total Latent Gain: 800 Btuh 13 %
Total Cooling Required: 6,267 Btuh 0.52 Tons(Based On Sensible+ Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\renar sales.rh9 Saturday, May 20, 2017, 11:29 AM
Rhvac Residential 8 Light Commercial HVAC Loads Elite Software Development,Inc:
Preferred AirCondittornng&Mech 9316 0 drif Circle
wesf.pilrriteach,FL 33409 Fa a 15
System Z Zone 2 Pie Chart
Floor 35% Glass 34%
System
2, Zone
2
Loss
6,293
Btuh
Roof 5%
Wall 26%
Roof 9%
Equipment 19%
Wall 14%
System
2, Zone
2
Gain -
6,267
Btuh r
5:
People 27%
Glass 30%
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\renar sales.rh9 Saturday, May 20, 2017, 11:29 AM