Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Project Information (3)
POWERLIE- T HYDRAULIC DOORS Installation Instructions Metal Frame Inside Mount November 2012 FILE COPI�,, SAFETY You are responsible for the safe use of this product. Unsafe use could result in property damage, serious personal injury, serious injury to others or a fatality. Do not operate the door until you understand all the safety instructions. If you have any questions, contact your door provider or go to www.powerliftdoors.com for assistance. • Recognize safety information and labels: • The labels are located on the pump and at eye level at each door frame jamb. • Understand the label's meaning and the potential risk it identifies • Follow all information on the label • Keep the labels in good condition • Replace unreadable labels by contacting: your door installer or www.powerliftdoors.com Follow all safety instructions: • Read and understand all safety, operation and maintenance instructions • Allow only those persons who have read and understand the instructions to operate the door • Turn off power when making electrical connections or conducting any electrical work • Install all electrical connections per state and local codes • Do not re-adjust or modify the settings completed by the door installer • Avoid electrical shock by not operating controls with wet hands or standing on a wet surface • Operate the door only for the door's intended purpose • Inspect and verify that the area in the path of the door swing is free of equipment, vehicles or obstructions. • Stay alert and watch during the door's operation • Keep fingers and extremities away from pinch points located between the door and door frame • Keep children and pets away from the door while door is operating • Maintain the door in good operating condition • Wear safety glasses when using hydraulic connections • If a remote control is ordered, do not leave the remote transmitter where unauthorized persons could operate the control Maintenance Yearly inspect hoses, lines and connectors for signs of deterioration. Contact your door installer if deterioration is detected. In high moisture buildings, (dairy buildings, livestock confinements) replace the hydraulic oil to prevent moisture accumulation. Protect motor from excessive moisture. Installation Instructions for Metal Buildings PowerLift Hydraulic Doors is delighted to be providing our product on your project. We look forward to working with you and arranging for a quick and trouble-free installation. All PowerLift Hydraulic Doors will only be installed by our company representatives. By cooperating together we can provide an expedited project schedule. Several procedures should be completed for a trouble free installation. Prior to door fabrication and installation: The rough opening should be completed with the side columns plumb, straight and the header level, straight and without bow or twist. To eliminate any building movement, installation of roof framing, wall girts, and cross bracing should be concluded. Minimum 10 ga., 8" C-Channels are recommended. The Project must have drivable access to the project site and door rough opening. Door installation is preferred to be completed prior to concrete floor placement. By allowing our door frame posts to extend and the concrete placed around them, the post are soundly secured. For completed concrete floors, the PowerLift door installer will install anchor bolts and anchor plates. Door side jamb trim installed prior to door installation. This method is quicker and less problematic for the builder than installing the trim after the door is installed. PowerLift hydraulic doors field weld to the bottom of the header. Bracing should not extend into the rough opening. (See Typical Metal Header Detail drawing) The door purchaser is responsible to provide a telehandler, or other acceptable equipment capable of lifting the door from the trailer and carrying the door to the building opening. Four to five gallons of hydraulic oil, compatible to the Owner's equipment, available for pump installation. ISO 32 hydraulic oil is recommended. Permanent electrical power is not required for the door installation. However, a 220v and 30 amp breaker is required for permanent door operation. Door arrival: The door will arrive on a trailer pulled by our delivery truck with at least one door installer. The door and frame will arrive as one painted component. All horizontal wood girts, cylinders and hydraulic lines will be installed with the door. Metal girls can be provide in lieu of the wood if noted during the planning process The door will be moved from the trailer to the door rough opening with the help of the contractor supplied equipment. The PowerLift Installer, will then position, adjust and field weld the door to the building. Fastening is completed in two stages. First stage is by welding the door frame legs to the side post of the building. The second stage is by welding the door header to the building header. (See Typical Metal Header Detail and Typical Metal Side Jamb Detail drawings). Upon completion of securing the door, the hydraulic pump and connecting hydraulic hoses will be installed on the designated door side. Field framing should be provided for the installation of the pump. If the pump requires to be removed (for the example, for lining the building interior) fasteners of the same diameter but of longer length can be used. The height of the pump controls should located at 72" off finished floor. This discourages young or unauthorized individuals from operating the door. • The Powerlift Installer will connect temporary power and pour the hydraulic oil (supplied by others) into the pump reservoir. The door will be temporarily operated through several cycles. Any final adjustments will be completed prior to the installer leaving the project. If the Owner is available, operating instructions will be provided by the installer. A rubber membrane is provided as a weatherstripping to cover the hinges at the top of the door. The weatherstripping is fastened prior to door cladding installation. The weatherstripping should be placed on the building behind the steel above the door, approximately 2" in height. The weatherstripping will lay across the hinges, and be fastened to the door. Care should be taken to remove wrinkles and provide a smooth neat appearance when installing the weatherstripping. The weatherstripping is fastened on the outside of the door cladding. In the case of steel panels, fasten the weatherstripping with screws in every raised rib location through the J-channel. Any door trim and cladding must be sealed with a good quality sealant to prevent moisture from penetrating the door envelope. (See Typical Metal Header Detail drawing) Inspect the door to verify that the vertical margins are equal between the door and the building jambs. Window framing, windows and service doors can now be installed. When installing the door trims and cladding a minimal distance of 5 1/2" must be maintained between the trim or cladding above the header and the trim or cladding on the door. This allows the door to open past 90 degrees without damaging either material. Cladding material with deeper than 1" profiles will require more distance. In these circumstance raise the building trims and cladding above the rough opening. Operate the door to verify that the trims and cladding will not collide. (See Typical Metal Header Detail drawing) The door bottom weatherstripping has been left long at each end of the door. After door cladding completion the weatherstripping should be trimmed to snuggly touch each side jamb. This provides the best door seal. Seal the door frame to building jamb materials with a color matching sealant. Powerl-ift Hydraulic Doors are fabricated with the anticipation that the door will be insulated and completed with a liner panel. No additional door modifications are required if this application is undertaken in the future. P Wainscoting If wainscoting is scheduled, the bottom of the lowest girt will be the top of the wainscot height from the finished floor. Field framing members are fastened vertically under the girt by the builder. This results in 5" of fastening space for the wainscot and trims. Wiring Connections Both the pump and the remote control option can be wired by the same power supply. A 220v 30 amp breaker is required. All wiring is completed using the color coded wiring located in the pump switch box. (See Typical Electrical Connections drawing) ELECTRICAL WIRING SHALL BE INSTALLED BY AN ELECTRICAL CONTRACTOR AND MEET FEDERAL, STATE AND LOCAL CODES. Operating the door temporarily until permanent power is provided. READ AND FOLLOW ALL SAFETY INSTRUCTIONS The door is provided with pioneer e hydraulic nipples. These are located on the P type Y pP hydraulic lines directly above the locking valve. Tractors or other hydraulic equipment can operate the door using these connections. Hydraulic connections should left attached for the entire door cycle to prevent pressure buildup. If a generator must be used to supply temporary power for door operation, wiring, connections and power must be of adequate size. Do NOT starve the pump unit of electrical power. This will adversely affect the lifetime of the power unit and void the warranty. Only use a generator that can provide 10,000kw. Powerl-ift Hydraulic Doors cannot be responsible for field conditions or temporary connections associated with temporary generators. Suggested Framing Requirements DUE TO FIELD CONDITIONS AND VARYING BUILDING PRACTICES POWERLIFT HYDRAULIC DOORS CAN ONLY MAKE RECOMMENDATIONS BASED UPON PAST EXPERIENCE. THE BUILDING SUPPLIER IS RESPONSIBLE FOR INCORPORATING ANY REACTIONS OR STRESSES IMPOSED BY POWERLIFT HYDRAULIC DOORS INTO THE BUILDING DESIGN. THE FINAL BUILDING STRUCTURE'S INTEGRITY IS THE RESPONSIBILITY OF THE BUILDING SUPPLIER. Steel Buildings: Side Jamb: Minimum one 8" wide, full length 10 gauge c-channel securely anchored to the foundation and fastened to intermediate supports and rough opening framing. Jamb material shall run the entire height of the wall from foundation to roof main framing. Provide diagonal bracing (45 degree) at the vertical jamb at the top of the door opening to roofing members. Install a vertical jamb molding to finish the jamb opening. I-Beam or Wide Flange Beam Side Jambs: Columns must be securely anchored to the foundation and securely fastened to the building main frame. Weld 2" x 2" x 1/" angles horizontally between the column flanges every 24" on center or as specified by the building manufacturer. Position the angles so that the vertical 2" side is toward the rough opening to provide a surface for door welding. After the PowerLift door installation, install a vertical building jamb molding from the edge of the building to the PowerLift door frame to enclose the building. Header: Minimum single 8" wide, full header length 10 gauge c-channel or flanged beam • securely fastened or welded to side vertical supports and supported by the building structure. Provide diagonal bracing from header top to roofing members every hinge location or as specified by the building supplier. Minimum horizontal header deflection is 1". On 20' high doors, a diagonal from the upper cylinder mount is also recommended. Recommended diagonal bracing angle is 45 degrees. Windows: Windows can be installed in our doors. The window type selected is restricted to awning, fixed or sliding. The recommended rough opening or total size can be no larger than 5' wide or 4' high with no individual pane of glass being larger than 9 square feet (width multiplied by height). Recommended window mounting is by continuous molded or permanently attached window nail flange lapping the rough opening at least 1" at each edge and permanently fastened per manufactures instructions. All windows shall be installed per applicable building codes. Window supplier is responsible for: (a) providing windows of the correct glazing type, (b) sufficient framing and track depth so windows remain intact for door movement or varying horizontal positions, (c) installation of windows,per manufacturer's instructions and (d) warranty for installation conditions. Due to varying conditions, Powerlift Hydraulic Doors cannot be held liable for any conditions or circumstances resulting from window installation. 0 LPOwk ERLIFT HYDRAULIC DOORS www.powerliftdoors.com 1482 200th Ave. lake Beantoan,Mnnrnesota • Phone:507-368-9500 Fay 507-368-1358 Typical Metal Building Header Detail INSIDE OF BUILDING OUTSIDE-OF BUILDING Verify header requirements and wall construction with building supplier Metal building header Metal Sheeting Install diagonal bracing as required Minimum 8", 10 GA. minimum one at each hinge ' continous C-Channel I Bum thru weld Weld NOTES: Rubber weatherstripping to be installed o PRIOR to gable sheeting.Weatherstripping to be placed over door trims and under 5X5 Tube Header building trims and she" 5X2 Door top Door trim and sheeting to be 5 1/2"down from the bottom of header.Thicker Metal girt profiles require more distance.Weather- stripping over trims and sheeting 5X3 Tube Post Seal top to prevent water penetration Metal Sheeting Door Not to Scale Metal girt 11PkOWERLIFT )DRAULIC DOORS www.powerliftdoors.com 1482 200th Ave. Iahe Benton,Minnesota Phone:507-368-9500 Fay 507-368-1358 Typical I-Beam or Wide Flange Beam Side Jamb Detail INSIDE OF BUILDING OUTSIDE OF BUILDING &'metal building wall Jamb Column Metal Sheeting 2X2X1X'angle 24"O.C.installed by others NOTES: Welds Jamb coverings installed by others L 5X3 Door Tube 5X3 Tube Post Metal Sheeting Door Not to Scale 1rWftROELIFT HYDRAULIC DOORS www.powerliftdoors.com 1482 200thAve. • Izke Penton,Minnesota Phone:507-368-9500 Pax 507-368-1358 Typical Metal Building Side Jamb Detail OUTSIDE OF BUILDING 8"metal building wall INSIDE OF BUILDING Minimum 8", 10 GA. Metal Sheeting continous C-Channel 5" Bum thru weld NOTES: Weld Install side jamb coverings PRIOR to door installation 5X3 Door Tube 5X3 Tube Post Metal Sheeting Door ' Not to Scale PiOWERLIFT HYDRAULIC DOORS -www.powerliftdoors.com 1482 200th Ave. Lake Benton,DTmnesota Phone:507-368-9500 Fay 507-368-1358 Typical Inside Mount Threshold Detail w/Placed Concrete Metal Sheeting OUTSIDE OF BUILDING Swinging door Tube Post Not to Scale Bottom door truss LAG Exterior Grade NOTES: Existing Concrete Slope concrete and grade away bun building Ir i Typical Inside Mount Threshold Detail w/New Concrete Metal Sheeting OUTSIDE OF BUILDING Swinging Door INSIDE OF BUILDING Tube Post Bottom door truss Approx_2 U2' I � I 1 ' I NOTES: Exterior Grade New Concrete I I I `-----------f Slope concrete and grade away from budding i ji POWERLIFT HYDRAULIC DOORS www.powerliftdoors.com 1482 200thAve. Take Benton,Alinnesota Typical Electrical Connections Phone.507-3689500 Typical Motor Power Connections Pump unit Switch Control box Black Black White White Striped Green win: Green From permanent power supply 220vwith 30 amp breaker Switch Control box Typical Remote Control Electrical Connections Red Red Lower switch White White Capped Black Black and Taped together Green Green with black tape ;j From Remote Control Receiver Blue Box Fire . Rating Lemieux carrl�s a_full 6ne of ftrelated doors and lambs 'They range from 20 {rtegattve and posldve),_6Q,artd_90 minute rated models,In sw~zes up to 41p width _ _ and 8/Q height,_and are_................ availa6leln a range of custom sizes end designs,with either_ _ a.pllmed paint finish,or=a ahaice of�3 dtfferentspects of stain glade` 3 RI - — J Benefit frosts the:advantages of using a srngle source for all your fire rated door r y - _ _ requirements Our doors and lambs f1t with a quality end dural�iliry nothing shirt _ ON - - of-..enviable it's na longer a choice between form and fiunction because Lemie1�x's _ _ l _ t fire fated door products afford your phents the:peace of mand they need,and the — gteatlooks a - _ �IR� RATED pQOR SPECIFICAT�hIS __ _� n, �� _ Rating Cat.... a P. <: Maximum size opening Panel Prefit,. Av..ailable:~:z:;::- Standards - ro `:` to rail selection ..;:: coin liance i r Single:: ;:,.:.:.:::. Parrs . .file p. . p,......:_. Width Height Width Height Flat, 00:Prefit<_1/4 Square top door only Both positive and 1 4 A 48" 96" 84" 96" Raised(SH), 30:30-0"only with arched,classique neutral,UL 10(c), `4 Wgroove or round-top panel UBC 7-2(1997)Part 1, - 20 (SH&DH) o. NFPA 252, _ - 0a and 3. ASTM E2074-00 B 48" 96" N/A N/A Prefit s 1/4 Flat, 0°:Prefit_<1/4 Both positive and Raised(SH), 30:30-0"only neutral,UL 10(c), V-groove UBC 7-2(1997)Part 1, 60 A 48" 96" "84 96" ' (SH&DH) NFPA 252, ` ASTM E2074-00, ASTM E152-81a Flat, 00:Prefit s 1/4 Square top door only Both positive and = a Raised(SH), 30:3 -0 only with arched,classique neutral,UL 10(c), V-groove or round-tap panel UBC 7-2(1997)Part 1, 90 A 48" 96" N/A N/A (SH&DH) NFPA 252, ASTM E2074-01, ASTM E152 81a _ i. CATEGORY A: Lemieux Doors'category A doors are manufactured with a sealinto� � edges of the door.This means that no additional edge-sealing system is required le door and frLT CATEGORY B:These doors require an additional edge-sealing system between the "r d frame. I�KvinM44 si � tsusi � . Checking is.only for genital confornwnce wir, the design.concept of the'proiect and genera. :brnpliance with the information given in the lontraet documents. Any action shown is suf i ect to the requirements of the plans and Vecificetions. Contractor is responsible for.. Dimensions which shall be confirmed and coi itelatedet the job site;fabrication processes an lechniyuesoconstruction;.coordinauon o,hip= f"k with that of all other trades ar�d t#►e eatis factory perfOmtance 54 LEMIEUX DOORS BY MASONITE pate MIC-15405-2015-LEM-Oat-010416.indd 54 13Y �y-�.� 2/16/16 9:54AM �7:. -- ti a -t ' .. :'.C:+�.iii a'iii l..`,ll.lr �'i!,�.S,? i y':b - ._. •pis, .. ;�; .f!•�1 r..i:i s�.�'.;'� ,!•i, _ }'. ....a.y:`,p��ril`i"'�.:r4:!jis F�.�.i.`'�' .. s.v•. .. _�sit.:��:. ., .:i aRi .... .. .._ ." ..... �� P.�•,�.� s MASONITC. ARCHITECTURAL Standard Painted Doors • Min Models C-MDF-NR C-MDF-FR20 Thickness , 1-3/8",1-3/4"(20m 1-3/4"only) �- ITS-WH and UL-Max 20 Minute Sizes noted in this table are specific to 13/4•doors.Contact sales for intornation regarding other door thickness types. i — — i Non Rated Neutral Pressure ! CAT A Positive —I---_-- —�Pressure Maximum Size ; ----- � - --"'—'--'— Singles E 5'0"x8'0" 4'0"x8'0" '410"x810" i I Pairs E 81011x8101, 810"x8'0" ! 8'0"x8'0" DE Pairs N/A N/A N/A i Surface Material I Medium Density Fiberboard ..--...--... Crossbands N/A Vertical Edges' i Medium Density Fiberboard Horizontal Edges' 's Medium Density Fiberboard Face&Core Assembly Adhesive N/A .......... --- ——----- - • Core Construction Solid Panel Medium Density Fiberboard Factory glazing recommended. € Options of:Cut out,Cut-out with factory supplied MDF sticking, I 20m-Pyroswiss glass with Wood Vision Frame 7 • Lite Openings/Louvers i MDF Louvers-Non-rated only. IAvailable as:Vented,False,Chevron i Inset Mirrors Available:Non-rated only Distance from Lock&Lite Cutouts I N/A Details I N/A Machining i —Standard machining per hardware manufacturers templates --- _...____...----- --..._.__— ..----• ---------.._-_._.------- Factory Finish Primed and custom paint colors Acoustic Ratingt STC 35 Operable when installed with tested seals and gaskets Environmental Options 1 -CARB 2 i Environmental Product Declaration Yes Quality Standards I N/A WDMA Performance Duty Level N/A Door Weight Thickness Ibs/sf I Thickness Ibs/sf -- — 1-3/8" 4.8 ( 1-3/4" 6.1 Warranty 1 Limited Lifetime.No exterior warranty.Interior use only. Note:Doors are manufactured per the standards listed on this page.Specifications are subject to change without notice. Fire-Rated doors will be constructed per label service listing and may deviate from above. 877.332.4484 t STC Ratings is based on 1-3/4"doors. masonitea►chitectural.com MA_PDS-1055_v3 3/2017 9)2017 Masonite Architectural 3 MASONITC. ARCHITECTURAL Simulated Stile & Rail Doors i Multkayertom . . - • + Min MPF 20 Min Models i C-MDFSR-20 C-MDFSR-FR45 C-MDFSR-FR60 C-MDFSR-FR90 IThickness 1-3/4" r _ ITS-WH and UL-Max 20-90 Minute Sizes noted in this table are specific to 13/4"doors.Contact sales for Information regarding other door thickness types. 1CAT A Positive I CAT A Positive Neutral PressurePressure(45M-60M) Pressure(90M) Maximum Size j �Singles --^ -�4'O'x8'O" 14'0"x8'0" 14'O"x8'0"i Pairs j 8'O"x8'0" 7'0"x8'O" —� N/A DE Pairs^ N/A -f N/A N/A . . ..... . ... ---.._._._...__. .... . . ... .. . ... . . . ... .. ....._.._...- . - .... _ .. Surface Material Medium Density Fiberboard Crossbands N/A I 20 Min-Medium Density Fiberboard Vertical Edges' 45-90 Min-Hardwood Composite Fire Stile S Horizontal Edges' Manufacturers Standard per label agency listing Face&Core Assembly Adhesive j N/A Core Construction 20 Min-Medium Density Fiberboard i 45-90 Min-Multi-layer Composite . -----__-- � Factory glazing required -----_-- -^ - _-_-• `-- I 20m-Pyroswiss glass with Wood Vision Frame 7 • Llte Openings/Louvers 45m:Max vg.width 26".Max vg.length 48 Max total mg.1248sq in with 3/16"Keralite FR-F glass& Metal Vision Frame 60-90m: Max 100 Sq In vg.with Metal Vision Frame Distance from Lock&Lite Cutouts I N/A Details N/A - - - Machining { Per manufacturer's templates Factory Finish i Primed and custom paint colors Acoustic Rating+ STC 35 operable when installed with tested seals and gaskets --...----------- Environmental Options -CARE 2 I Environmental Product Declaration I Yes I Duality Standards I N/A WDMA Performance Duty Level N/A Thickness Ibs/sf I Thickness Ibs/sf Door Weight - - ---------- $..__ 1-3/4" 8(45-90 Min) 1-3/4" 6.1(20 Min) Warranty Limited Lifetime.No exterior warranty.Interior use only. Note:Doors are manufactured per the standards listed on this page.Specifications are subject to change without notice. Fire-Rated doors will be constructed per label service listing and may deviate from above. 877.332.4484 *STC Ratings is based on 1-3/4"doors. masonitearchitectural.com MA PDS-1058 v3 3/2017 ©2017 Masonite Architectural , t 3 � a�toazite, Molded Fire Ratings " nn�nTltdo« 20 min 45 min 60 min Positive Positive Positive Pressure Pressure Pressure as of:111OV2015 Cat a only Cat 8 only Cal a only 6o min " Masonite Commercial Boors 3'0•Sh�es 31P SaV- 3l0'Ssyka WA 2 Panel Commercial Smooth 6H' 60'Paha 70 � Smooth711" 6'0'Pts a0'Si�at Srglss NIA a*. S"drs 3VSig"ea 3'0'Sn0'tl MIA 2 Panel Roman Commercial Smooth 6'6` 60•Pahs 36-SPP— 3W qV aW ftk. NIA Smooth TO' 6n•Paas ad'Sa�es WA WA MIA 6 Panel Commercial Smooth 6'H" Co•P.S, 30'%V. WA WA NIA Smooth7'0" 6o•Pars Masonite Classics" 2 Panel Smooth 6'8• 6o•Psss 3W 5*" 30'Siglaa WA 30•Shrdes 3L'Sigte: a0'1-1 MIA Smooth 7'0" 6'0•PaSs Smooth 60" 3'0'Sades WA WA WA 36914fts wsav 30•BYg%. WA 2 Panel Roman Smooth 6'H" 6o•Pms 3'65ades 3WSiK* aw Sigtn WA Smooth TO" or Pd+s Smooth 60" 30'8n4es WA WA MIA 30'Snges 3T&V. 3U'Sryha WA 2 Panel Arch Tap Smooth 6'B• 60'Pa4s .To*STd I 3'0`S,01. 3W sivirs MIA Smooth TO' or Pak. Smooth 60" ao,ftq s WA WA WA 2 Panel Arch Top Teximed 6H" 60'Pue �`� 3tY 5igks MIA 76 sodas WA WA WA 3 Panel To..6, 60'P6. 30.sk4. WA WA WA 4 Panel Smooth 6'H" 6v Pass 360"Ssr,}'aa WA WA WA Smooth TO" 6a•PaSs Smooth 60" 3,(rwgte, WA WA WA %m Sit a` WA WA WA 6 Panel Smooth 6H" 60•PAFs Smooth T6' 60• MIA WA NIA i Smooth 60" 3'0'64es NIA WA NIA 36 S"dac NIA WA NIA 6 Panel Tenured We" 60•Pans ' 663§glss WA WA NIA Toxtured 710" 6.0'Pei9 TB dUred OW 30•Sildrs WA WA MIA Masonite Select- To.Sages WA WA NIA Cheyenne Smooth 6.6' 66 Paks Smooth 8'0" 30•Sln4es WA WA NIA To'-d- WA WA NIA I ' Riverside Smooth 6B" 610,Nk. 3P%V. WA WA NIA Smooth TO" 60'Paus Smooth 0'0" Mr sud. WA WA MIA xT 9+4os ae'S"¢es a6 s aka NIA Saddfabroak Smoolhfi'a" sn•P&s I Smaotha'0" 3a`SU4. aU'Siides so-sigl0a NA Masonite Expo-. 3P S"dav NIA WA NtA Winslow Smooth We" 60•Pass ,To-Vogs WA WA WA Smooth TO" 6V Pa'rs 3R Smdaa WA WA NA Lincoln Park Smooth 6'H' sn•PAs 30•S4gas WA WA NIA Smooth 7V" 6'6P&. Smoath60" 3C Wq- WA WA WA Berkley Smoalh WV �6WPaass WA WA NIA Smooth TO" 37 si4® WA WA WA 3-0•Smdu WA WA WA Hamel Smooth 6'B" 6,,. 30•STdes WA WA NIA Smooth o•TO" 6P&s 3'0•Smdes WA WA WA Melrose Smooth TV 60•PASs 70•Sages WA WA NA Smooth T6" 60'palm a0'S"dm WA WA NIA Bellaglo Smooth 6'H" OW Pa4s a66a4a WA WA NIA Smooth TO' 6W Pa>s Smooth 60" O'o'M4. WA WA NIA 70'%n. WA WA NA Capri SmaoU 6'H" 6o'paY 6e'%nde9 Smooth T WA WA NIA O" 6e•Pme SmDOth 60' 365iidn WA WArWA WA NIANA NA 3?SNdes Treviso Smooth 6'H' 6v'Pass 36 S"dn Smooth TO" 60•Pais Smooth 60' 7P S4gles raA WA WA NOTE: 24"is the smallest width that is available in Fire Rated Molded Doors 8'0"2 panel Door Designs are available in Neutral Pressure Masonite Fire Door Offering Residential Flush & Molded Panel = Molded Panel • 20-minute Positive Pressure o 3'-0"x 8'-0"Max Singles o 6'-0"x T-0"Max Pairs • 45-minute Positive Pressure 0 3'-0"x T-0"Max Singles o No Pairs • 60-minute Positive Pressure o 3'-0"x 7'-0"Max Singles • 60-minute Neutral Pressure 0 3'-0"x >7'-0"-8'-0" Max Singles o No Pairs Flush -Species: Hardboard, Maple, Birch, Red Oak& Okume • 20-minute Positive Pressure o 3'-0"x 8'-0" Max Singles o 6'-0"x 7'-0"Max Pairs • 45-minute Positive Pressure ' o 3'-6"x 8'-0"Max Singles o No Pairs • 60-minute Positive Pressure 0 3'-6"x 8'-0"Max Singles o No Pairs • 90-minute Positive Pressure n W-R"x R'-n"AAgY..ginnlPs o No Pairs Factory Hardware Preparations • Cylindrical Latch • Deadbolt Latch • Mortise Latch • Hinge (4"or 4-1/2") • Viewer/Peepsite (1"maximum diameter hole) • Cutouts for Fire Rated Glazing (Flush Doors only) 0 20-minute= 1,296 sq in maximum 0 45-minute=960 sq in maximum 0 60-minute=960 sq in maximum 0 90-minute = 100 sq in maximum r � BXUV.U419-Fire Resistance Ratings-ANSI/UL 263 ONLINE CERTIFICATIONS DIQCfl IORY Design No. U419 BXUV.U419 Fire Resistance Ratings - ANSI/UL 263 "Reprinted from the Online Certifications Directory with permission from UL" ` Design/System/Construction/Assembly Usage Disclaimer . Authorities Having Jurisdiction should be consulted in all cases as to the particular requirements covering the installation and use of UL Certified products, equipment, system, devices, and materials. . Authorities Having Jurisdiction should be consulted before construction. • Fire resistance assemblies and products are developed by the design submitter and have been investigated by UL for compliance with applicable requirements. The published information cannot always address every construction nuance encountered in the field. . When field issues arise, it is recommended the first contact for assistance be the technical service staff provided by the product manufacturer noted for the design. Users of fire resistance assemblies are advised to consult the general Guide Information for each product category and each group of assemblies. The Guide Information includes specifics concerning alternate materials and alternate methods of construction. • Only products which bear UL's Mark are considered Certified. SXUV - Fire Resistance Ratings - ANSI/UL 263 SXUV7 - Fire Resistance Ratings - CAN/ULC-S101 Certified for Canada Deign No. U419 Y April 12, 2016 Nonbearing Wall Ratings—1,2,3 or 4 Hr(See Items 4&5 through 5K) *Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification(such as Can�da),respectively. Al tiz 1/11 r BXUV.U419-Fire Resistance Ratings-ANSIIUL 263 3 r x i to A 1. Floor and Ceiling Runners— (Not Shown) — For use with Item 2- Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min depth to accommodate stud size, with min 1-1/4 in. long legs, attached to floor and ceiling with fasteners 24 in. OC max. ^ 1A. Framing Members*—Floor and Ceiling Runner— Not Shown — In lieu of Item 1 — For use with Item 26, ` proprietary channel shaped runners, 3-5/8 in. deep attached to floor and ceiling with fasteners 24 in. OC max. CALIFORNIA EXPANDED METAL PRODUCTS CO —Viper25'" Track w Y CRACO MFG INC— SmartTrack25'" MARINO/WARE,DIV OF WARE INDUSTRIES INC—Viper25—Track 16. Framing Members*—Floor and Ceiling Runner— Not Shown— In lieu of Item 1 — For use with Item 2C, proprietary channel shaped runners, 1-1/4 in. wide by 3-5/8 in. deep fabricated from min 0.020 in. thick gaiv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. CALIFORNIA EXPANDED METAL PRODUCTS CO —Viper20— Track MARINO/WARE,DIV OF WARE INDUSTRIES INC—Viper201"Track IC. Framing Members*—Floor and Ceiling Runners— (Not Shown) — In lieu of Item 1 - Channel shaped, attached to floor and ceiling with fasteners 24 in. OC. max. ALLSTEEL&GYPSUM PRODUCTS INC—Type SUPREME Framing System CONSOLIDATED FABRICATORS CORP,BUILDING PRODUCTS DIV —Type SUPREME Framing System QUAIL RUN BUILDING MATERIALS INC—Type SUPREME Framing System SCAFCO STEEL STUD MANUFACTURING CO —Type SUPREME Framing System STEEL CONSTRUCTION SYSTEMS INC—Type SUPREME Framing System 2/11 BXUV.U419-Fire Resistance Ratings-ANSI/UL 263 UNITED METAL PRODUCTS INC—Type SUPREME Framing System ID. Floor and Ceiling Runners— (Not Shown) — For use with Item 2A—Channel shaped, fabricated from min 20 MSG corrosion-protected or galv steel, min depth to accommodate stud size, with min 1 in. long legs, attached to floor and ceiling with fasteners spaced max 24 in. OC. 1E. Framing Members*—Floor and Ceiling Runners— (Not Shown, As an alternate to Item 1) — For use with Items 2E, 5F or 5G or 5I only, channel shaped, fabricated from min. 0.015 in. (min bare metal thickness) galvanized steel, attached to floor and ceiling with fasteners 24 in. OC, max. CLARKDIETRICH BUILDING SYSTEMS— CD ProTRAK DMFCWBS L L C— ProTRAK MBA METAL FRAMING — ProTRAK RAM SALES L L C— Ram ProTRAK STEEL STRUCTURAL PRODUCTS L L C—Tri-S PrcTRAK 1F. Framing Members*—Floor and Ceiling Runner— Not Shown— In lieu of Item 1 — For use with Item 2F, proprietary channel shaped runners, minimum width to accommodate stud size, with 1- 1/8 in. long legs fabricated from min 0.015 in. (min bare metal thickness) gaiv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. SUPER STUD BUILDING PRODUCTS—The Edge 1G. Framing Members*-Floor and Ceiling Runner— For use with Item 2G, proprietary channel shaped runners, minimum width to accommodate stud size attached to floor and ceiling with fasteners 24 in. OC max. STUDCO BUILDING SYSTEMS— CROCSTUD Track 1H. Floor and Ceiling Runners— (Not Shown) —Channel shaped, fabricated from min 0.02 in. gals steel, min width to accommodate stud size, with min 1 in. long legs, for use with studs specified below and fabricated from min 0.02 in. gaiv steel or thicker, attached to floor and ceiling with fasteners spaced max 24 in. OC. MARINO/WARE,DIV OF WARE INDUSTRIES INC—Viper201"Track VT100. 1I. Framing Members*—Floor and Ceiling Runners— (Not Shown, As an alternate to Item 1) —For use with Items 2H, channel shaped, fabricated from min. 0.015 in. (min bare metal thickness) galvanized steel, attached to floor and ceiling with fasteners 24 in. OC. max. TELLING INDUSTRIES L L C—TRUE-TRACK' 13. Framing Members*—Floor and Ceiling Runner— Not Shown —In lieu of Item 1 — For use with Item 2I, proprietary channel shaped runners, 3-5/8 in. deep attached to floor and ceiling with fasteners 24 in. OC max. TELLING INDUSTRIES L L C—Viper25'" Track 1K. Framing Members*—Floor and Ceiling Runner— Not Shown —In lieu of Item 1— For use with Item 23, proprietary channel shaped runners, 1-1/4 in. wide by 3-5/8 in. deep fabricated from min 0.020 in. thick galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. TELLING INDUSTRIES L L C—Viper20'" Track 1L. Framing Members*—Floor and Ceiling Runners— (Not Shown) —As an alternate to Item 1- For use with Item 2N. Channel shaped, attached to floor and ceiling with fasteners 24 in. OC, max. BAILEY METAL PRODUCTS LTD—Type PLATINUM PLUS 3/11 BXUV.U419-Fire Resistance Ratings-ANSI/UL 263 1M. Framing Members*—Floor and Ceiling Runners— Not Shown — As an alternate to Item 1— For use with Item 20, proprietary channel shaped runners, min width to accommodate stud size, galv steel, attached to floor and ceiling with fasteners spaced 24 in. OC max. RONDO BUILDING SERVICES PTY LTD— Rondo Wall Track 2. Steel Studs— Channel shaped, fabricated from min 25 MSG corrosion-protected steel, min depth as indicated under Item 5, spaced a max of 24 in. OC. Studs to be cut 3/8 to 3/4 in. less than assembly height. " 2A. Steel Studs— (As an alternate to Item 2, For use with Items 513, 5E, 5H, 5) and 5K) Channel shaped, fabricated from min 20 MSG corrosion-protected or galv steel, 3-1/2 in. min depth, spaced a max of 16 in. OC. Studs friction-fit ' into floor and ceiling runners. Studs to be cut 5/8 to 3/4 in. less than assembly height. 213. Framing Members*-Steel Studs— (As an alternate to Item 2, For use with Items 5C, 5I or 5K) - Proprietary channel shaped studs, 3-5/8 in. deep spaced a max of 24 in. OC. Studs to be cut 3/4 in less than the assembly height and installed with a 1/2 in. gap between the end of the stud and track at the bottom of the wall. For direct attachment of gypsum board only. CALIFORNIA EXPANDED METAL PRODUCTS CO —Viper25•" CRACO MFG INC— SmartStud25TM MARINO/WARE,DIV OF WARE INDUSTRIES INC— Viper25TM 2C. Framing Members*—Steel Studs— Not Shown — In lieu of Item 2— proprietary channel shaped steel studs, min depth as indicated under Item 5, spaced a max if 24 in. OC, fabricated from min 0.020 in. thick galv steel. Studs cut 3/8 in. to 3/4 in. less in lengths than assembly heights. CALIFORNIA EXPANDED METAL PRODUCTS CO —Viper20'" MARINO/WARE,DIV OF WARE INDUSTRIES INC— Viper20TM 2D. Framing Members*—Steel Studs— In lieu of Item 2- Channel shaped studs, min depth as indicated under f Item 5, spaced a max of 24 in. OC. Studs to be cut 3/4 in. less than assembly height. • ALLSTEEL&GYPSUM PRODUCTS INC—Type SUPREME Framing System CONSOLIDATED FABRICATORS CORP,BUILDING PRODUCTS DIV —Type SUPREME Framing System QUAIL RUN BUILDING MATERIALS INC—Type SUPREME Framing System SCAFCO STEEL STUD MANUFACTURING CO —Type SUPREME Framing System STEEL CONSTRUCTION SYSTEMS INC—Type SUPREME Framing System UNITED METAL PRODUCTS INC—Type SUPREME Framing System 2E. Framing Members*—Steel Studs— (Not Shown, As an alternate to Item 2) —For use with Items 5F or 5G or 5I or 5K only, channel shaped studs, min depth as indicated under Item 5F, 5G or 5I, fabricated from min. 0.015 in. (min bare metal thickness) galvanized steel, spaced a max of 24 in. OC. Studs to be cut 3/4 in. less than assembly height. CLARKDIETRICH BUILDING SYSTEMS— CD ProSTUD DMFCWBS L L C— ProSTUD MBA METAL FRAMING — ProSTUD RAM SALES L L C— Ram ProSTUD 4/11 BXUV.U419-Fire Resistance Ratings-ANSIIUL263 STEEL STRUCTURAL PRODUCTS L L C—Tri-S ProSTUD 2F. Framing Members*—Steel Studs— Not Shown — In lieu of Item 2— proprietary channel shaped steel studs, minimum width indicated under Item 5, 1-1/4 in. deep fabricated from min 0.015 in. (min bare metal thickness) galvanized steel. Studs 3/8 in. to 3/4 in. less in lengths than assembly heights. SUPER STUD BUILDING PRODUCTS—The Edge 2G. Framing Members*—Steel Studs— Not Shown— In lieu of Item 2- proprietary channel shaped studs, minimum width indicated under Item 5, Studs to be cut 3/8 to 3/4 in less than the assembly height. STUDCO BUILDING SYSTEMS— CROCSTUD 2H. Framing Members*—Steel Studs— (Not Shown, As an alternate to Item 2) — Fabricated from min. 0.015 in. (min bare metal thickness) galvanized steel, spaced a max of 24 in. OC. Studs to be cut 3/4 in. less than assembly height. TELLING INDUSTRIES L L C—TRUE-STUD•" 2I. Framing Members*—Steel Studs— (As an alternate to Item 2, For use with Items 5C or 5L or 5K) - Proprietary channel shaped studs, 3-5/8 in. deep spaced a max of 24 in. OC. Studs to be cut 3/4 in less than the assembly height and installed with a 1/2 in. gap between the end of the stud and track at the bottom of the wall. For direct attachment of gypsum board only. TELLING INDUSTRIES L L C—Viper2.5T" *— d — Not Shown —In lieu of Item 2— proprietary channel shaped steel studs, 27. Framing Members Metal Studs min depth as indicated under Item 5, spaced a max if 24 in. OC, fabricated from min 0.020 in. thick galv steel. Studs cut 3/8 in. to 3/4 in. less in lengths than assembly heights TELLING INDUSTRIES L L C—Viper20'" _ 2K. Framing Members*—Steel Studs— As an alternate to Item 2— For use with Item 1, channel shaped studs, fabricated from min 25 MSG corrosion-protected steel, min depth as indicated under Item 5, spaced a max of 24 in. OC. Studs to be cut 3/8 to-3/4 in. less than assembly height. EB METAL INC— EB Stud 2L. Framing Members*—Steel Studs—As an alternate to Item 2— For use with Item 1, channel shaped studs, fabricated from min 25 MSG corrosion-protected steel, min depth as indicated under Item 5, spaced a max of 24 in. OC. Studs to be cut 3/8 to 3/4 in. less than assembly height. OLMAR SUPPLY INC— PRIMESTUD 2M. Framing Members*—Steel Studs— As an alternate to Item 2— For use with Item 1, channel shaped studs, fabricated from min 25 MSG corrosion-protected steel, min depth as indicated under Item 5, spaced a max of 24 in. OC. Studs to be cut 3/8 to 3/4 in. less than assembly height. MARINO/WARE,DIV OF WARE INDUSTRIES INC— StudRiteTM 2N. Framing Members*—Steel Studs— As an alternate to Item 2— For use with Item 1L, channel shaped, min 3- 5/8 in. wide, spaced a max of 24 in. OC. Studs to be cut 3/8 to 3/4 in. less than assembly height. BAILEY METAL PRODUCTS LTD—Type PLATINUM PLUS 20. Framing Members*—Steel Studs— As an alternate to Item 2— proprietary channel shaped steel studs, min width as indicated under Item 5, galy steel. Studs to be cut 3/8 to 3/4 in. less in lengths than assembly height. Spaced 24 in. OC max. RONDO BUILDING SERVICES PTY LTD— Rondo Lipped Wall Stud 3. Wood Structural Panel Sheathing— (Optional, For use with Item 5 Only.) — (Not Shown) - 4 ft wide, 7/16 in. thick oriented strand board (OSB) or 15/32 in. thick structural 1 sheathing (plywood) complying with DOC PS1 or PS2, or APA Standard PPP-108, manufactured with exterior glue, applied horizontally or vertically to the steel studs. Vertical 5/11 BXUV.U419-Fire Resistance Ratings-ANSI/UL 263 joints centered on studs, and staggered one stud space from wallboard joints. Attached to studs with flat-head self- drilling tapping screws with a min. head diam. of 0.292 in. at maximum 6 in. OC. in the perimeter and 12 in. OC. in the field. When used, gypsum panels attached over OSB or plywood panels and fastener lengths for gypsum panels increased by min. 1/2 in. 4. Batts and Blankets*— (Required as indicated under Item 5) — Mineral wool batts, friction fitted between studs and runners. Min nom thickness as indicated under Item 5. See Batts and Blankets(BKNV or BZJZ)Categories for names of Classified companies. 4A. Batts and Blankets*— (Optional) — Placed in stud cavities, any glass fiber or mineral wool insulation bearing the UL Classification Marking as to Surface Burning Characteristics and/or Fire Resistance. See Batts and Blankets (BKNV or BZJZ)Categories for names of Classified companies. ` 4B. Batts and Blankets*— For use with Item 5K. Placed in stud cavities, any min. 3-1/2 in. thick glass fiber insulation bearing the UL Classification Marking as to Surface Burning Characteristics and/or Fire Resistance. See Batts and Blankets(BKNV or BZJZ)Categories for names of Classified companies. S. Gypsum Board*— Gypsum panels with beveled, square or tapered edges, applied vertically or horizontally. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Vertical joints in adjacent layers (multilayer systems) staggered one stud cavity. Horizontal joints need not be backed by steel framing. Horizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered. Horizontal edge joints and horizontal butt joints in adjacent layers (multilayer systems) staggered a min of 12 in. The thickness and number of layers for the 1 hr, 2 hr, 3 hr and 4 hr ratings are as follows: Gypsum Board Protection on Each Side of Wall Min No.of Min Stud Layers Thkns of Depth,in. &Thkns Insulation Rating,Hr Items 2,2C,2D,2F,2G,20 of Panel (Item 4) 1 3-1/2 1 layer, 5/8 in. thick Optional 1 2-1/2 1 layer, 1/2 in. thick 1-1/2 in. 1-5/8 1 layer, 3/4 in. thick Optional 1-5/8 2 layers, 1/2 in. thick Optional 2 1-5/8 2 layers, 5/8 in. thick Optional 3-1/2 1 layer, 3/4 in. thick 3 in. 3 1-5/8 3 layers, 1/2 in. thick Optional 3 1-5/8 2 layers, 3/4 in. thick Optional 3 1-5/8 3 layers, 5/8 in. thick Optional 1-5/8 4 layers, 5/8 in. thick Optional 4 1-5/8 4 layers, 1/2 in. thick Optional 4 2-1/2 2 layers, 3/4 in. thick 2 in. CGC INC— 1/2 in. thick Type C, IP-X2 or IPC-AR; WRC, 5/8 in. thick Type AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, WRX or WRC; 3/4 in. thick Types IP-X3 or ULTRACODE UNITED STATES GYPSUM CO — 1/2 in. thick Type C, IP-X2, IPC-AR or WRC; 5/8 in. thick Type SCX, SGX, SHX, WRX, IP-X1, AR, C, WRC, FRX-G, IP-AR, IP-X2, IPC-AR ; 3/4 in. thick Types IP-X3 or ULTRACODE USG BORAL ZAWAWI DRYWALL L L C SFZ— 1/2 in. Type C; 5/8 in. Types C, SCX USG MEXICO S A DE C V— 1/2 in. thick Type C, IP-X2, IPC-AR or WRC; 5/8 in. thick Type AR, C, IP-AR, IP-X1, IP- X2, IPC-AR, SCX, SHX, WRX, WRC or; 3/4 in. thick Types IP-X3 or ULTRACODE When Item 7B, Steel Framing Members*, is used, Nonbearing Wall Rating is limited to 1 Hr. Min. stud depth is 3-1/2 in., min. thickness of insulation (Item 4) is 3 in., and two layers of gypsum board panels(1/2 in. or 5/8 in. thick) shall be attached to furring channels as described in Item 6. One layer of gypsum board panels (1/2 in. or 5/8 in. thick) attached to opposite side of stud without furring channels as described in Item 6. 5A. Gypsum Board*— (As an alternate to Item 5) — 5/8 in. thick, 24 to 54 in. wide, applied horizontally as the outer layer to one side of the assembly. Secured as described in Item 6. CGC INC—Type SHX. 6/11 BXUV.U419-Fire Resistance Ratings-ANSI/UL 263 UNITED STATES GYPSUM CO —Type FRX-G, SHX. USG MEXICO S A DE C V —Type SHX. 5B. Gypsum Board*— (Not Shown) —As an alternate to Item 5 when used as the base layer on one or both sides of wall when 5/8 in or 3/4 in. thick products are specified. For direct attachment only to steel studs Item 2A, (not to be used with Item 3) -- Nom 5/8 in. or 3/4 in. may be used as alternate to all 5/8 in. or 3/4 in. shown in Item 5, Wallboard Protection on Each Side of Wall table. Nom 5/8 in. or 3/4 in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min 1 stud cavity on opposite sides of studs. Gypsum board secured to 20 MSG steel studs Item 2A with 1-1/4 in. long Type S-12 steel screws spaced 8 in. OC at perimeter and 12 in. OC in the field. To be used with Lead Batten Strips (see Item 11) or Lead Discs or Tabs (see Item 12). RAY-BAR ENGINEERING CORP—Type RB-LBG 5C. Gypsum Board*— (For Use With Item 2B) Rating Limited to 1 Flour. 5/8 in. thick, 48 in. wide, Gypsum panels with beveled, square or tapered edges, applied vertically or horizontally. (Vertical Application) -The gypsum board is to be installed on each side of the studs with 1 in. long Type S coated steel screws spaced 8 in. OC starting 4 in. from the edge of the board at the vertical edges and 12 in. OC starting 6 in. from the edge of the board at the center of each board. Gypsum boards are to be secured to the top and bottom track with screws spaced 8 in. OC starting 4 in. from the board edge. Fasteners shall not penetrate through both the stud and the track at the same time. Vertical joints are to be centered over studs and staggered one stud cavity on opposite sides of studs. (Horizontal Application) -The gypsum board is to be installed on each side of the studs with 1 in. long Type S coated steel screws spaced 8 in. OC starting 4 in. from the edge of the board at the vertical edges and 12 in. OC starting 6 in. from the edge of the board at the center of each board. Gypsum boards are to be secured to the top and bottom track with screws spaced 8 in. OC starting 4 in. from the board edge. Fasteners shall not penetrate through both the stud and the track at the same time. All horizontal joints are to be backed as outlined under section VI of Volume 1 in the Fire Resistive Directory. CGC INC—Type SCX. UNITED STATES GYPSUM CO —Type SCX, SGX. USG SORAL ZAWAWI DRYWALL L L C SFZ—Type SCX USG MEXICO S A DE C V —Type SCX. 5D. Gypsum Board*— (As an alternate to Item 5) — 5/8 in. thick, 48 in. wide, applied vertically or horizontally. Secured as described in Item 6. For use with Items 1 and 2 only. CGC INC—Type USGX. UNITED STATES GYPSUM CO —Type USGX. USG MEXICO S A DE C V —Type USGX. 5E. Gypsum Board*— (Not Shown) — (As an alternate to Item 5 when used as the base layer on one or both sides of wall when 1/2 in. or 5/8 in thick products are specified, For direct attachment only to steel studs Item 2A, not to be used with Item 3). Nominal 5/8 in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min 1 stud cavity on opposite sides of studs. Wallboard secured to studs with 1-1/4 in. long Type S-12 (or No. 6 by 1-1/4 in, long bugle head fine driller) steel screws spaced 8 in. OC at perimeter and 12 in. OC in the field. NEW ENGLAND LEAD BURNING CO INC,DBA NELCO — Nelco 5F. Gypsum Board*--- (As an alternate to Item 5) — For use with Items 1E and 2E and limited to 1 Hour Rating only, Gypsum panels with beveled, square or tapered edges, applied vertically, and fastened to the steel studs with 1 in. long Type S screws spaced 8 in. OC along vertical and bottom edges and 12 in. OC in the field. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Steel stud depth shall be a minimum 3-5/8 in. UNITED STATES GYPSUM CO — 5/8 in. thick Type SCX, SGX. 7/11 BXUV.U419-Fire Resistance Ratings-ANSIIUL 263 USG BORAL ZAWAWI DRYWALL L L C SFZ — 5/8 in. thick Type SCX 5G. Gypsum Board*— (As an alternate to Item 5) — For use with Items 1E and 2E only, Gypsum panels with beveled, square or tapered edges, applied vertically or horizontally, as specified in the table below and fastened to the steel studs as described in Item 6. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Vertical joints in adjacent layers(multilayer systems) staggered one stud cavity. Horizontal joints need not be backed by steel framing. Horizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered. Horizontal edge joints and horizontal butt joints in adjacent layers(multilayer systems) staggered a min of 12 in. The thickness and number of layers for the 2 hr, 3 hr and 4 hr ratings are as follows: Gypsum Board Protection on Each Side of Wall Min Stud No.of Layers Min Thkns of Rating, Depth,in. &Thickness Insulation Hr Item 2E of Panel (Item 4) 2 1-5/8 2 layers, 1/2 in. thick Optional 2 F111ptiii,ons, 5/8 in. thick Optional 3 s, 1/2 in. thick Optional3 s, 5/8 in. thick Optional4 s, 5/8 in. thick Optionalrs, 1/2 in. thick Optional CGC INC— 1/2 in. thick Type C, IP-X2 or IPC-AR;, 5/8 in. thick Type AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, or; 3/4 in. thick Types IP-X3 or ULTRACODE UNITED STATES GYPSUM CO — 1/2 in. thick Type C, IP-X2, IPC-AR or; 5/8 in. thick Type SCX, SGX, SHX, IP-X1, AR, C, , FRX-G, IP-AR, IP-X2, IPC-AR ; 3/4 in. thick Types IP-X3 or ULTRACODE ~ USG BORAL ZAWAWI DRYWALL L L C SFZ — 1/2 in. Type C; 5/8 in. Types C, SCX K USG MEXICO S A DE C V — 1/2 in. thick Type C, IP-X2, IPC-AR or; 5/8 in. thick Type AR, C, IP-AR, IP-X1, IP-X2, IPC-AR, SCX, SHX, or; 3/4 in. thick Types IP-X3 or ULTRACODE 5H. Gypsum Board*— (Not Shown) — (As an alternate to Item 5 when used as the base layer on one or both sides of wall when 5/8 or 3/4 in thick products are specified. For direct attachment only to steel studs Item 2A, (not to be used with Item 3) - Nom 5/8 or 3/4 in, may be used as alternate to all 5/8 or 3/4 in. shown in Item 5, Wallboard Protection on Each Side of Wall table. Nom 5/8 or 3/4 in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over 20 MSG steel studs and staggered min 1 stud cavity on opposite sides of studs. Wallboard secured to studs with 1-1/4 in. long Type S-12 steel screws spaced 8 in. OC at perimeter and 12 in. OC in the field. Gypsum board secured to 20 MSG steel studs Item 2B with 1-1/4 in. long Type S- 12 steel screws spaced 8 in. OC at perimeter and 12 in. OC in the field. For Joint Compound see Item 5. To be used with Lead Batten Strips(see Item 11A) or Lead Discs(see Item 12A). MAYCO INDUSTRIES INC—Type X-Ray Shielded Gypsum 5I. Gypsum Board*— (As an alternate to Item 5) — Nom. 5/8 in. thick gypsum panels with beveled, square or tapered edges installed as described in Item 5. Steel stud minimum depth shall be as indicated in Item S. CGC INC—Type ULX UNITED STATES GYPSUM CO —Type ULX USG MEXICO S A DE C V —Type ULX 53. Gypsum Board*— (Not Shown) — (As an alternate to Item 5 when used as the base layer on one or both sides of wall when 1/2 in. or 5/8 in thick products are specified, For direct attachment only to steel studs Item 2A, not to be used with Item 3). Nom 5/8 in. thick lead backed gypsum panels with beveled, square or tapered edges, applied vertically. Vertical joints centered over studs and staggered min 1 stud cavity on opposite sides of studs. Wallboard secured to studs with 1-1/4 in. long Type S-12 steel screws gypsum panel steel screws spaced 8 in. OC at perimeter and 12 in. OC in the field. Lead batten strips required behind vertical joints of lead backed gypsum wallboard and 8/11 BXUV.U419-Fire Resistance Ratings-ANSI/UL 263 optional at remaining stud locations. Lead batten strips, min 2 in, wide, max 8 ft long with a max thickness of 0.14 in. placed on the face of studs and attached to the stud with construction adhesive and two 1 in. long Type S-12 pan head steel screws, one at the top of the strip and one at the bottom of the strip. Lead discs, nominal 3/8 in. diam by max 0.085 in. thick. Compression fitted or adhered over the screw heads. Lead batten strips and discs to have a purity of 99.9% meeting the Federal specification QQ-L-201f, Grade"C". RADIATION PROTECTION PRODUCTS INC—Type RPP- Lead Lined Drywall • 5K. Gypsum Board*— (Not Shown) — (As an alternate to Item 5) — Nom. 5/8 in. thick gypsum panels with beveled, square or tapered edges, applied vertically or horizontally. Vertical joints centered over studs and staggered one stud cavity on opposite sides of studs. Vertical joints in adjacent layers(multilayer systems) staggered one stud cavity. Horizontal joints need not be backed by steel framing. Horizontal edge joints and horizontal butt joints on opposite sides of studs need not be staggered. Horizontal edge joints and horizontal butt joints in adjacent layers(multilayer systems) need not be staggered. The number of layers for the 1 hr, 2 hr, 3 hr and 4 hr ratings are as follows: Gypsum Board Protection on Each Side of Wall Min No.of Min Stud Layers Thkns of Depth,in. &Thkns Insulation Rating,Hr Items 2 through 20 of Panel (Item 4B) 1 3-5/8 glayer, Fthick Hin.2 1-5/8 3 1-5/8 4 1-5/8 UNITED STATES GYPSUM CO — 5/8 in. thick Type ULIX 6. Fasteners— (Not Shown) — For use with Items 2 and 2F- Type S or S-12 steel screws used to attach panels to studs(Item 2) or furring channels(Item 7). Single layer systems: 1 in. long for 1/2 and 5/8 in. thick panels or 1-1/4 in. long for 3/4 in. thick panels, spaced 8 in. OC when panels are applied horizontally, or 8 in. OC along vertical and bottom edges and 12 in. OC in the field when panels are applied vertically. Two layer systems: First layer- 1 in. long for 1/2 and 5/8 in. thick panels or 1-1/4 in. long for 3/4 in. thick panels, spaced 16 in. OC. Second layer- 1-5/8 in. long for 1/2 in., 5/8 in. thick panels or 2-1/4 in. long for 3/4 in. thick panels, spaced 16 in. OC with screws offset 8 in. from first Iayer.Three-Bayer systems:First layer- 1 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Second layer- 1-5/8 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Third layer- 2-1/4 in. long for 1/2 in., 5/8 in. thick panels or 2-5/8 in. long for 5/8 in. thick panels, spaced 12 in. OC. Screws offset min 6 in. from layer below. Four-layer systems:First layer- 1 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Second layer- 1-5/8 in. long for 1/2 in., 5/8 in. thick panels, spaced 24 in. OC. Third layer- 2-1/4 in. long for 1/2 in. thick panels or 2-5/8 in. long for 5/8 in. thick panels, spaced 24 in. OC. Fourth layer- 2-5/8 in. long for 1/2 in. thick panels or 3 in. long for 5/8 in. thick panels, spaced 12 in. OC. Screws offset min 6 in. from layer below. 6A. Fasteners— (Not Shown) — For use with Item 5K-Type S or S-12 steel screws used to attach panels to studs or furring channels(Item 7). Single layer systems: 1 in. long screws, spaced 8 in. OC when panels are applied horizontally, or 8 in. OC along vertical and bottom edges and 12 in. OC in the field when panels are applied vertically. Two layer systems: First layer- 1 in. long screws, spaced 16 in. OC. Second layer- 1-5/8 in. screws, spaced 8 in. OC with screws offset 8 in. from first layer. Three-layer systems: First layer- 1 in. long screws, spaced 24 in. OC. Second layer- 1-5/8 in. long screws, spaced 24 in. OC. Third layer- 2-5/8 in. long screws, spaced 8 in. OC. Screws offset min 6 in. from layer below. Four-layer systems: First layer- 1 in. long screws, spaced 24 in. OC. Second layer- 1-5/8 in. long screws, spaced 24 in. OC. Third layer- 2-5/8 in. long screws, spaced 24 in. OC. Fourth layer- 3 in. long screws, spaced 8 in. OC. Screws offset min 6 in. from layer below. 7. Furring Channels— (Optional, Not Shown, for single or double layer systems) — Resilient furring channels fabricated from min 25 MSG corrosion-protected steel, spaced vertically a max of 24 in. OC. Flange portion attached to each intersecting stud with 1/2 in. long Type S-12 steel screws. Not for use with Item 5A and 5E. 7A. Framing Members*— (Optional on one or both sides, not shown, for single or double layer systems) —As an alternate to Item 7, furring channels and Steel Framing Members as described below: a. Furring Channels— Formed of No. 25 MSG galv steel. 2-9/16 in. or 2-23/32 in. wide by 7/8 in. deep, spaced max. 24 in. OC perpendicular to studs. Channels secured to studs as described in Item b. Gypsum board attached to furring channels as described in Item 6. Not for use with Item 5A and 5E. b. Steel Framing Members*— Used to attach furring channels (Item 7Aa) to studs (Item 2). Clips spaced max. 48 in. OC. RSIC-1 and RSIC-1(2.75) clips secured to studs with No. 8 x 1- 1/2 in. minimum self-drilling, S-12 steel screw through the center grommet. RSIC-V and RSIC- V (2.75) clips secured to studs with No. 8 x 9/16 in. minimum self-drilling, S-12 steel screw through the center hole. Furring channels are friction fitted into clips. RSIC-1 and RSIC-V clips for use with 2-9/16 in. wide furring channels. RSIC-1 (2.75) and RSIC-V (2.75) clips for use with 2-23/32 in. wide furring channels. PAC INTERNATIONAL L L C—Types RSIC-1, RSIC-V, RSIC-1 (2.75), RSIC-V (2.75). 9/11 BXUV.U419-Fire Resistance Ratings-ANSI/UL 263 7B. Framing Members*— (Optional, Not Shown) —As an alternate to Item 7, for single or double layer systems, furring channels and Steel Framing Members on only one side of studs as described below: a. Furring Channels— Formed of No. 25 MSG galv steel, spaced 24 in. OC perpendicular to studs. Channels secured to studs as described in Item b. Batts and Blankets placed in stud cavity as described in Item 5. Two layers of gypsum board attached to furring channels as described in Item 5. Not for use with Item 5A and 5E. b. Steel Framing Members*— Used to attach furring channels (Item 7Ba) to one side of studs(Item 2) only. Clips spaced 48 in. OC., and secured to studs with two No. 8 x 2-1/2 in. coarse drywall screws, one through the hole at each end of the clip. Furring channels are friction ' fitted into clips. KINETICS NOISE CONTROL INC—Type Isomax 7C. Framing Members*— (Not Shown) — (Optional on one or both sides, not shown, for single or double layer systems) —As an alternate to Item 7, furring channels and Steel Framing Members as described below: a. Furring Channels— Formed of No. 25 MSG galv steel. 2-3/8 in. wide by 7/8 in. deep, spaced max. 24 in. OC perpendicular to studs. Channels secured to studs as described in Item b. Gypsum board attached to furring channels as described in Item 6. Not for use with Item 5A and 5E. b. Steel Framing Members*— Used to attach furring channels (Item 7Aa) to studs (Item 2). Clips spaced max. 48 in. OC. GENIECLIPS secured to studs with No. 8 x 1-1/2 in. minimum self-drilling, S-12 steel screw through the center grommet. Furring channels are friction fitted into clips. PLITEQ INC—Type GENIECLIP 7D. Steel Framing Members*— (Optional, Not Shown) — Furring channels and resilient sound isolation clip as described below: a. Furring Channels— Formed of No. 25 MSG galv steel. Spaced 24 in. OC perpendicular to studs. Channels secured to studs as described in Item b. Ends of adjoining channels overlapped 6 in. and secured together with four self-tapping No. 8x1/2 Self Drilling screws(2 per side 1 in. and 4 in. from overlap edge). Gypsum board attached to furring channels as described in Item 4. Side joint furring channels shall be attached to studs with RESILMOUNT Sound Isolation Clips - located approximately 2 in. from each end of length of channel. Both Gypsum Boards at side joints fastened into channel with screws spaced 8 in. OC, approximately 1/2 in. from joint edge. Not for use with Item 5A and 5E. b. Steel Framing Members*— Resilient sound isolation clip used to attach furring channels (Item 7Da) to studs. Clips spaced 24 in. OC., and secured to studs with No. 10 x 2-1/2 in. coarse drywall screw through the center hole. Furring channels are friction fitted into clips. STUDCO BUILDING SYSTEMS— RESILMOUNT Sound Isolation Clips- Type A237 or A237R 8. Joint Tape and Compound—Vinyl or casein, dry or premixed joint compound applied in two coats to joints and screw heads of outer layers. Paper tape, nom 2 in. wide, embedded in first layer of compound over all joints of outer layer panels. Paper tape and joint compound may be omitted when gypsum panels are supplied with a square edge. 9. Siding,Brick or Stucco— (Optional, Not Shown) —Aluminum, vinyl or steel siding, brick veneer or stucco, meeting the requirements of local code agencies, installed over gypsum panels. Brick veneer attached to studs with corrugated metal wall ties attached to each stud with steel screws, not more than each sixth course of brick. 10. Caulking and Sealants*— (Optional, Not Shown) —A bead of acoustical sealant applied around the partition perimeter for sound control. UNITED STATES GYPSUM CO —Type AS 11. Lead Batten Strips— (Not Shown, For Use With Item 5B) — Lead batten strips, min 1-1/2 in. wide, max 10 ft long with a max thickness of 0.125 in. Strips placed on the interior face of studs and attached from the exterior face of the stud with two 1 in. long Type S-12 pan head steel screws, one at the top of the strip and one at the bottom of the strip. Lead batten strips to have a purity of 99.9% meeting the Federal specification QQ-L-201f, Grade "C". Lead batten strips required behind vertical joints of lead backed gypsum wallboard (Item 5B) and optional at remaining stud locations. Required behind vertical joints. 11A. Lead Batten Strips— (Not Shown, For Use With Item 5H) Lead batten strips, 2 in. wide, max 10 ft long with a max thickness of 0.140 in. Strips placed on the face of studs and attached to the stud with two min. 1 in. long min. Type S-8 pan head steel screws, one at the top of the strip and one at the bottom of the strip or with one min. 1 in. long min. Type S-8 pan head steel screw at the top of the strip. Lead batten strips to have a purity of 99.5% meeting the Federal specification QQ-L-201f, Grades "B, C or D". Lead batten strips required behind vertical joints of lead backed gypsum wallboard and optional at remaining stud locations. ' 12. Lead Discs or Tabs— (Not Shown, For Use With Item 5B) — Used in lieu of or in addition to the lead batten strips (Item 11) or optional at other locations- Max 3/4 in. diam by max 0.125 in. thick lead discs compression fitted or adhered over steel screw heads or max 1/2 in. by 1-1/4 in. by max 0.125 in. thick lead tabs placed on gypsum boards 10/11 BXUV.U419-Fire Resistance Ratings-ANSI/UL 263 (Item 513) underneath screw locations prior to the installation of the screws. Lead discs or tabs to have a purity of 99.9% meeting the Federal specification QQ-L-201f, Grade "C". 12A. Lead Discs— (Not Shown, for use with Item 5H) Max 5/16 in. diam by max 0.140 in. thick lead discs compression fitted or adhered over steel screw heads. Lead discs to have a purity of 99.5% meeting the Federal Specification QQ-L-201f, Grades "B, C or D". 13. Lead Batten Strips— (Not Shown, For Use With Item 5E) Lead batten strips, 2 in. wide, max 10 ft long with a max thickness of 0.142 in. Strips placed on the face of studs and attached to the stud with two min. 1 in. long min. Type S-8 pan head steel screws, one at the top of the strip and one at the bottom of the strip or with one min. 1 in. long min. Type 5-8 pan head steel screw at the top of the strip. Lead batten strips to have a purity of 99.9% meeting the Federal specification QQ-L-201f, Grade "C". Lead batten strips required behind vertical joints of lead backed gypsum wallboard (Item 5E) and optional at remaining stud locations. • 14. Lead Tabs— (Not Shown, For Use With Item 5E) 2 in. wide, 5 in. long with a max thickness of 0.142 in. Tabs friction-fit around front face of stud, the stud folded back flange, and the back face of the stud. Tabs required at each location where a screw (that secures the gypsum boards, Item 5E) will penetrate the steel stud. Lead tabs to have a purity of 99.9% meeting the Federal specification QQ-L-201f, Grade "C". Lead tabs may be held in place with standard adhesive tape if necessary. *Indicates such products shall bear the UL or cUL Certification Mark for jurisdictions employing the UL or cUL Certification (such as Canada),respectively. Last Updated on 2016-04-12 © 2016 UL LLC The appearance of a company's name or product in this database does not in itself assure that products so identified have been manufactured under UL's Follow-Up Service. Only those products bearing the UL Mark should be considered to be Certified and covered under UL's Follow-Up Service. Always look for the Mark on the product. UL permits the reproduction of the material contained in the Online Certification Directory subject to the following conditions: 1. The Guide Information, Assemblies, Constructions, Designs, Systems, and/or Certifications (files) must be presented in their entirety and in a non- misleading manner, without any manipulation of the data (or drawings). 2.The statement "Reprinted from the Online Certifications Directory with permission from UL" must appear adjacent to the extracted material. In addition, the reprinted material must include a copyright notice in the following format: "© 2016 UL LLC".