HomeMy WebLinkAboutRevision - SepticGENERAL NOTES
FRONT-
SIDES _
C11B SIDES
REAR -
ZNG,
EXIST. BARBWIRE FENCE
1. SEE SHEET A-1 FO2 ALL INTERIOR & EXTERIOR DIMENSIONS.
2. SEE SHEET S-1 FOt FOUNDATION DETAILS.
3. BEFORE SOD IS LAD, THE FINISH SITE GRADING SHALL BE INSPECTED BY
THE GOVERNING VATER CONTROL DISTRICT &/OR SAINT LUCIE COUNTY
AS APPLICABLE.
4. SITE GRADING SHILL DRAIN TO MATCH EXISTING.
5. SIDE PROPERTY SIOPES SHALL NOT EXCEED A 4:1 SLOPE PER
SAINT LUCIE COUJTY AS APPLICABLE.
6. DRIVEWAY TURNQUTS SHALL BE PER SAINT LUCIE COUNTY SPECIFICATIONS
AS APPLICABLE.
LAND CLEARING& FILL NOTES:
1. THERE ARE NO PL\TTED PRESERVE AREAS ON SITE.
2. THE VACANT PARCEL HAS BEEN SURVEYED AND THERE ARE
NO ENVIRONMENFALLY SENSITIVE OR ENDANGERED FLORA OR
FAUNA ON SITE, IIICLUDING GOPHER TORTOISES.
3. ENTIRE SITE PREVDUSLY CLEARED AS NECESSARY.
4. PROOF ROLL BUIL)ING PAD AREA.
5. PROVIDE COMPACT CLEAN FILL IN 12" LIFTS.
6. ALL LIFTS SHALL B_ TESTED FOR COMPACTION, INCLUDING
PROOF ROLLING, V/ (4) DENSITY TEST PER LIFT.
7. ALL COMPACTIONSHALL INCLUDE PASSES W/ ROLLER AND
AS PER GEOTECHPIICAL ENGINEER'S RECOMMENDATIONS.
8. PROVIDE PROCTOR FOR FILL MATERIAL.
9. ALL DENSITIES REQUIRE MIN. 98% AASHTO-T180.
SITE SPECIFICATIONS:
1. COORDINATE W/ OWNER & SOILS REPORT (IF APPLICABLE) FOR PROPER
SITE PREPARATION & BUILDING PAD COMPACTION.
2. PROVIDE COMPACTION TESTS AND CONCRETE TESTS PER CODE.
3. PROVIDE TEMPORARY SANITARY, WATER AND ELECTRICAL SERVICES
AS REQUIRED.
4. PROVIDE MAIL BOX PER SAINT LUCIE COUNTY REQUIREMENTS.
S. IRRIGATION SYSTEM W/ 2" WELL REQUIRED.
6. FPL, ATT, & CABLESERVICE AND CONNECTION FEES BY OWNER.
HEALTH DEPARTMENT NOTES:
1. CONFIRM ALL SEPFIC SYSTEMS REQUIREMENTS W/
ST. LUCIE COUNTY HEALTH DEPT.
2. HEALTH DEPT. SHALL DICTATE SIZES/CAPACITY OF SEPTIC TANK
& DRAIN FIELD & SETBACK REQUIREMENTS.
3. COORDINATE PERv11T REQUIREMENTS & APPLICATION W/
SURVEYOR AND/CR HEALTH DEPT. CONSULTANT -
FIND. I.B.& C.
UNREADABLE
Y
p V
N � F
SITE DATA:
PROPERTY ADDRESS: LOT 98, NAVION ROAD
ST. LUCIE COUNTY, FLORIDA 34987
P.C.N.:4224-501-0098-000-1
LEGAL DESCRIPTION: LOT 98, OF TREASURE COAST AIRPARK, ACCORDING
TO THE PLAT THEREOF, RECORDED IN PLAT BOOK 26, PAGE 18,1JA
THROUGH 18F, OF THE PUBLIC RECORDS OF ST.LUCIE COUNTY, FLORIDA
ZONING: AG-5
LOT SIZE: 216,199 S.F. (4.96 ACRES)
STRUCTURE LOT COVERAGE:
ALLOWED - 10.0% MAX. Q
PROVIDED - 1.9% = OK
SETBACKS: PROVIDED REQUIRED
FRONT (SOUTH) 350.0' to PL 50.0'
320.0'to RWL
REAR (NORTH) 270.0' 30.0'
SIDE (EAST) 193.3' 20.0'
SIDE (WEST) 60.0' 20.0'
REVISIONS:
No: DATE COMMEN
1Q 05-17-17 PERMIT I
2 06-28-17 SEPTIC / I
DESIGN CRITERIA
2014 FBC CHAPTER 16
ST. LUCIE COUNTY, FL
V ult. WIND SPEED:
165 MPH
EQUIV. BASIC WIND SPEED:
128 MPH
RISK CATEGORY: 2
EXPOSURE: C
MEAN HEIGHT: 19'-91,
SLOPE: 3:12
ENCLOSED STRUCTURE
INTERNAL PRESSURE:
±0.18
IMPORTANCE FACTOR:
1.00
BUILDING AREA S.F. BREAKDOWN
�-
HANGAR: 2,641 S.F.
CONDITIONED LIVING AREA: 959 S.F.
COVERED PORCH 410 S.F.
TOTAL GROSS AREA: 4,010 S.F.
�)
LOT 99 +"
VACANT
NO EXISTING WELLS OR +o
SEPTIC SYSTEMS PRESENT.
"6,ti0+ H I
EXISTINC CULVERT wI I
N 00 1 "W(C)690 00' P LMj TOREWIN. ya"+ -
n F-
p1 of � 'P6
EXISTING PILE OF FILL
TO BE SPREAD ON SITE.
1b ( bh
9
+ p
(lob "M
+ 4'x4'CONC.
270'� �--� y1 DOOR srooP. PROPOSED
-_ _ RFC1-hp IN, fP
30' 3,600 S.F. FOOTPRINT
REQ'D. SETBACK F.F ELEV. = 32.00
ARROWS DESIGNATE PROPOSED SEPTIC TANK
+ GRADING/DRAINAGE 900 GALLONS.
"off FLOW, TYP.
"
+"0p
- / t
/
/
EXISTING DRIVEWAY w I TO BE ABANDONED.
/ I
/
Fo 0� 5 6
+1'
/
DRIVEWAY CULVERT &
MTERED END SECTIONS
PER ST. LUCIE COUNTY
REQUIREMENTS. II
41,_
-4 \
i /0po \\
09
+"1' I ARROWS DESIGNATE
GRADING/DRAINAGE \I Q
FLOW, TYP. 50'
SEDGE OF POND 350,
PONBLDG. SETBACK TO PROPERTX LINE
0 320' \
±31 5' ryp' BLDG. SETBACK TO R.O.W.
O
PROPOSED DRAIN FIELD I I U 1 1/4"0 PVC WATER LINE TO \\
750 S.F. W/ 1.5 TIMES --� I ELEC. \ EXISTING WELL.
AVAILABLE AREA = 1,125 S.F. L - - - - - - -J U METER \ \ ap EXISTING WELL PUMP TO BE \\
12' 4" PVC SANITARY a� \ "9Nb \ + RELOCATED, SEE PLUMBING PLAN.
U.E. oo"� LINE TO SEPTIC TANK. \+ �SSIII 6 I EXISTING ELEC. SERVICE/METER TO BE
+" ry$ �6-RELOCATED, SEE ELECTRICAL PLAN.
EXISTING ELEC. TRANSFORMER
dQ � TO REMAIN, CONFIRMW/FPL-
------ /
N r +
N
N 00032'21"W(CL$ 690.00v(P)(M) $p'- 12' UTILITY EASE
12' UTILITY `1p. 200 AMP 120/240V
FIND I.B.& C. EASEMENT U.G. ELEC. SERVICE TO
UNREADABLE EXIST. PAD MOUNTED +"'I'
Tx'. VERIFY W/ FPL REP. +*
rp' +
.
+
�+ "p,tee
SITE PLAN
LOT 97
VACANT
NO EXISTING WELLS OR
SEPTIC SYSTEMS PRESENT.
REQ'D. SETBACK
UNDERGROUND UTILITY SERVICES:
1. PROVIDE PHONE U.G. SERVICE
/O VERIFY W/AREP.
Az 2. PROVIDE CABLE
U.G. SERVICE
,'t., VERIFY W/ CABLE REP.
NI
W
,I nil
rybh
+ 111
Qv/
A
r%
SCALE. 7" = 30'-0"
ra1
a ck
® a
Lift Z
Q
QF..0
Oc
06 v
ya �
C f0 CO ,.�_.. N Q
U (1) U U) 06 V /L�:
�y` I N = 0 N o7j vL
U O TI
w C 2 W
y�oa to
4 C
aQ 7
BENCHMARK O d � " U
FND.N&D LB 6018 LL W a InJ 4 Q.
ELEVATION 28.75 :ft N
0�9.� ►1
oS� C
C
c
O
c1c
� C
a
a
D.N&D
6018
I
IF 9
1
Ni
Job Number:
Drawn By:
rss
Date:
01-27-
Sheet Number
CALL 48 HOURS BEFORE YOU DIG C 1
IN FLORIDA 1-800-432-4770 IT'S
THE LAW SUNSHINE STATE ONE
CALL OF FLORIDA, INC.