Loading...
HomeMy WebLinkAboutApproved PlansST. LtTCTE CnUNTY RE nn f• nn7SION BF;VTF N%'ED FOR DNIPL ILk'SCE NEVIEWE B �— DATE T PLANS PE tMIT MUST BE KEPT ON JO^ OR NO LNSPECTION WILL BE GLADE, File Copy CONCEALED FASTENERS OR ATTACHMENTS ARE THE RESPONSIBUTY OF THE QR of1AiYm THESE PLANS AND ALL PROPOSED WOFK ARE SUBJECT TO ANY CORRECTIONS REQUIRED BY FIELD INSPECTORS THAT MAYBE NECESSARY IN ORDER TO COMPLY WITH ALL APPLICABLE CODES,' Til II II II II II II II III { II II II II II II II II II III I II li I I I III (E) zxlo @ 1s" O.C. II II II II II II II II II III I II II II II II II II II I II II II LI II II II II II III I II II II II II II II II II III I II II II II II II li II II {I� II II II II II II II II II II I II II II II II II II II II III I II II II II II II II LI II III I II II II II II II II II II III { II II II II II II II II II III I l II I I I III (N) 2x12 P.T. FASCIA W/ (2) #12 SCR. @ EA. JOIST �Ir IT l DECK FRAMING PLAN SCALE 1/4" = T-O" (E) BEDROOM (E) FLOOR co CD O O i ti r SECTION SCALE: 1/2" = V-0" SGD (N) 44 P.T. WOOD POST @ 60" O.C. MAX. W/ (2) J" x 6" S.S. LAG BOLTS THRU FASCIA 2x6 TOP RAILING REMAIN) `(E) 2x2 PICKETS (TO REMAIN) 4x4 P.T. WOOD POST REMAIN) (N) 4x4jWT. WOOD POST @ 60;,O.C. MAX. (N) (2) J' x 6" S.S. LAG BOLTS \—(E) DECK \—(E) 2x10 @ 16" O.C. 6" (TO REMAIN) 2x12 P.T. FASCIA ?. ,. W/ (2) #12 SCR. @ EA, JOIST I I (E) GARAGE I I�(E)GARAGE ENTRANCE (N) 4x4 P.T. WOOD POST (N)(2) I" x 6" S.S. -N,� @ 60" O.C. MAX. LAG BOLTS (N) 2xl0 P.T. BLOCKING W/ (2) #12 SCR. @ EA. J .(E) 2x10 @ 16" O.C. TOP VIEW (N) 2xl2 P.T. FASCIA W/ (2) #12 SCR. @ EA. JOIST I I I � I I I I E ABOVED ARAGE I I I I I I I I � I AREA OF WORK EXISTING CONDITIONS PLAN SCALE 1/8" = V-0" ABBREVIATIONS AB - ANCHOR BOLT FIG - FOOTING AHJ - AUTHORITY HAVING JURISDICTION HORIZ - HORIZONTAL ALT - ALTERNATE IN - INCH/INCHES BOTT - BOTTOM MAS - MAS RY CMU - CONCRETE MASONRY UNIT MAX - MAXIMUM COL - COLUMN MFR - MANUFACTURER CONC - CONCRETE MIN - MINIMUM CONT - CONTINUOUS MISC - MISCELLANEOUS DIA - DIAMETER MPH - MILES PER HOUR DIM - DIMENSION NIS ' - NOT TO SCALE D&E - DRILLED AND EPDXIED OC - ON CENTER EA - EACH PSF - POUNDS PER SQUARE FOOT ELEV - ELEVABON/ELEVATOR REV - REW YON/REWSED ENGR - ENGINEER SCHED - SCHEDULE EW - EACH WAY TYP - TYPICAL E - EXISTING UNO - UNLESS NOTED OTHERWISE EXP - EXPANSION VERT - VERTICAL EXT - EXTERIOR W/ - WITH FBC - FLORIDA BUILDING CODE W/a _ WMOUT FF - FINISH FLOOR µfW1 - WELDED WIRE FABRIC FND - FOUNDATION Wl{b/ - WELDED WIRE MESH FT - FEET/FOOT 15 - STEEL REINFORCING BAR (REBAR) 15 (5/8 ) STRUCTURAL -GENERAL NO I'ES DESIGN CRITERIA AND LOADS; 1. WIND DESIGN: WIND SPEED (MPH) V(ADJ)=140 V(ULT)=170 RISK CATEGORY /I EXPOSURE CATEGORY D ENCLOSURE CLASSIFICATION (DECK) OPEN INTERNAL PRESSURE COEFFICIENT CPI =+/- 0.00 TOPOGRAPHIC FACTOR KZT =1.0 2. DESIGN LIVE LOADS: a. WOOD DECK LIVE LOADS: 60 PSF b. BALCONY RAILING & GUARDRAILS 50 LBS/FT OR 200 LBS TO BE APPLIED AT ANY DIRECTION TO THE TOP RAIL. 3. DESIGN DEAD LOADS: a. WOOD DECK DEAD LOAD 12 PSF 4. THE CONTRACTOR HAS THE RESPONSIBILITY TO NOTIFY THE STRUCTURAL ENGINEER OF RECORD (SER) OF ANYARCHITECTURAL, MECHANICAL, ELECTRICAL, OR PLUMBING LOAD IMPOSED ONTO THE STRUCTURE THAT DIFFERS FROM, OR THAT IS NOT DOCUMENTED ON THE ORIGINAL CONTRACT DOCUMENTS (ARCHITECTURAL/STRUCTURAU MECHANICAL/ ELECTRICAL OR PLUMBING DRAWINGS). PROVIDE DOCUMENTATION OF LOCATION, LOAD, SIZEAND ANCHORAGE OF ALL UNDOCUMENTED LOADS IN EXCESS OF 400 POUNDS. PROVIDE MARKED -UP STRUCTURAL PLAN INDICATING LOCATIONS OF ANYNEW EQUIPMENT OR LOADS. SUBMIT PLANS TO THE ARCHITECT/ENGINEER FOR REVIEW PRIOR TO INSTALLATION. 5. LOADS ON THE STRUCTURE DURING CONSTRUCTION SHALL NOT EXCEED THE DESIGN LOADS AS NOTED IN DESIGN CRITERIA & LOADS BELOW OR THE CAPACITY OF PARTIALLY COMPLETED CONSTRUCTION AS DETERMINED BY THE CONTRACTOR'S SSE FOR BRACING/SHORING. 6, WHERE THE LIVE LOADS FOR WHICH EACH PORTION OF THE FLOOR HAS BEEN DESIGNED TO EXCEED 50 PSF, SUCH LOAD SHALL BE POSTED IN THAT PART OF EACH STORY IN WHICH THEY APPLY. GENERAL REQUIREMENTS 1. PLAN AND DETAIL NOTES AND SPECIFIC LOADING DATA PROVIDED ON INDIVIDUAL PLANS AND DETAIL DRAWINGS SUPPLEMENTS INFORMATION IN THE STRUCTURAL GENERAL NOTES. 2. THE DESIGN AND CONSTRUCTION OF THIS PROJECT IS GOVERNED BY THE "FL.ORIDA BUILDING CODE (FBC)", FIFTH EDITION, HEREAFTER REFERRED TO AS THE FBC, AS ADOPTED AND MODIFIED BYTHEAUTHORITYHAVING JURISDICTION (AHJ). 3. WHERE OTHER STANDARDS ARE NOTED IN THE DRAWINGS, USE THE LATEST EDITION OF THE STANDARD UNLESS A SPECIFIC DATE IS INDICATED. REFERENCE TO A SPECIFIC SECTION IN A CODE DOES NOT RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE ENTIRE STANDARD. 14. THE CONTRACTOR IS RESPONSIBLE FOR THE MEANS AND METHODS OF CONSTRUCTION AND ALL JOB RELATED SAFETY STANDARDS SUCH AS OSHA AND DOSH (DEPARTMENT OF OCCUPATIONAL SAFETY AND HEALNT 5. THE STRUCTURAL DRA WINGS ARE INTENDED TO SHOW THE GENERAL CHARACTER AND EXTENT OF THE PROJECTAND ARE NOT INTENDED TO SHO WALL DETAILS OF THE WORK. ARCHITECTURAL DRAWINGS SHALL GOVERN THE WORK FOR ALL DIMENSIONS. 6. SHOP DRAWINGS WILL BE REVIEWED FOR GENERAL COMPLIANCE WITH THE DESIGN INTENT OF THE CONTRACT DOCUMENTS ONLY. IT SHALL BE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY COMPLIANCE WITH THE CONTRACT DOCUMENTS AS TO QUANTITY, LENGTH, DIMENSIONS, ELEVATIONS,ETC. 7. SHOP DRAWINGS SHALL BE REVIEWED BY CONTRACTOR PRIOR TO SUBMITTAL TO THE ARCHITECT/ENGINEER DRAWINGS SUBMITTED WITHOUT REVIEW WILL BE RETURNED UNCHECKED. B. CHANGES AND ADDITIONS MADE ON RE -SUBMITTALS SHALL BE CLEARLY CLOUDED AND NOTED. ARCHITECT/ENGINEER REVIEW WILL BE LIMITED TO THOSE ITEMS CAUSING THE RE -SUBMITTAL, 9. DISCREPANCIES, OMISSIONS, OR INCONSISTENCIES WITH APPLICABLE CODE REQUIREMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT/ENGINEER IN WRITING BEFORE SUBMITTING A BID OR PROCEEDING WITH THE WORK. 10. THE CONTRACTOR SHALL VERIFYALL DIMENSIONS AND CONDITIONS AT THE SITE. CONFLICTS BETWEEN THE DRAWINGS AND ACTUAL SITE CONDITIONS SHALL BE BROUGHT TO THE ATTENTION OF THE ARCH17ECTIENGINEER IN WRITING BEFORE PROCEEDING WITH THE WORK. 11. THE CONTRACTOR IS RESPONSIBLE FOR THE STRENGTH AND STABILITY OF THE STRUCTURE DURING CONSTRUCTION AND SHALL PROVIDE TEI -RARY SHORING, BRACING AND OTHER ELEMENTS REQUIRED TO MAINTAIN STABILITY UN, , HE STRUCTURE IS COMPLETE. DO NOT LOr, , STRUCTURES, NEW OR EXISTING, WITH WEIGHT THAT WILL ENDANGER STRUCTURE, IT IS THE CONTRACTOR'S RESPONSIBILITY TO BEfAMILIAR WITH THE WORK REQUIRED IN THE CONSTRUCTION DOCUMENTS AND THE REQUIREMENTS FOR EXECUTING IT PROPERLY. 41 .2 - THE CONTRACTOR SHALL COMPLY WITH OCCUPA AL SAFETYAND HEALTH ADMINISTRATION STANDARD 1926 SUBPART M APP B 1926.502(b)(3). aQARDRAIL SYSTEMS SHALL BE CAPABLE OF WITHSTANDING, WITHOUT FAILURE, A FORCE OF AT LEAST 200 POUNDS APPLIED WITHIN 2 INCHES OF THE TOP EDGE, IN ANY OUTWARDS OR DOWNWARD DIRECTION, AT ANY POINT ALONG THE TOP EDGE. 13. THE CONTRACTOR SHALL COMPLY WITH OCCUPATIONAL SAFETYAND HEALTH ADMINISTRATION STANDARD 1926 SUBPART M APP B. FOR WOOD RAILINGS. WOOD COMPONENTS SHALL BE MINIMUM 1500 LB-FT/IN (2) FIBER (STRESS GRADE) CONSTRUCTION GRADE LUMBER; THE POSTS SHALL BEAT LEAST 2 INCH BY 4 INCH LUMBER SPACED NOT MORE THAN 8 FEET APART ON CENTERS; THE TOP RAIL SHALL BEAT LEAST 2 INCH BY 4INCH LUMBER, THE INTERMEDIATE RAIL SHALL BEAT LEAST 1 INCH BY 61NCH LUMBER, ALL LUMBER DIMENSIONS ARE NOMINAL SIZES AS PROVIDED BY THE AMERICAN SOFTWOOD LUMBER STANDARDS, DATED JANUARY 1970. 14. THE CONTRACTOR SHALL COMPLY WITH OCCUPATIONAL SAFETYAND HEALTH ADMINISTRATION STANDARD 1926 SUBPART M APP B 1926.502(b)(4). WHEN THE 200 POUND TEST LOAD SPECIFIED IN PARAGRAPH (b)(3) IS APPLIED IN A DOWNWARD DIRECTION, THE TOP EDGE OF THE GUARDRAIL SHALL NOT DEFLECT TO A HEIGHT LESS THAN 39 INCHES ABOVE THE WALKING/WORKING LEVEL. GUARDRAIL SYSTEM COMPONENTS SELECTED AND CONSTRUCTED IN ACCORDANCE WITH THE APPENDIX B TO SUBPART M OF THIS PART WILL BE DEEMED TO MEET THIS REQUIREMENT. §TRUCTURAL CERTIFICATION I. 1 CERTIFY THAT THE PLANS AND SPECIFICATIONS COMPLY WITH THE STRUCTURAL PORTION OF THE FLORIDA BUILDING CODE FIFTH EDITION. ?. 1 ALSO CERTIFY THAT STRUCTURAL ELEMENTS DEPICTED ON THESE PLANS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS SPECIFIED IN SECTION 1609 IN THE FBC AND CHAPTER 3 IN THE FBC-RESIDENTIAL. VOOD CONSTRUCTION NOTES ALL WOOD AND WOOD CONSTRUCTION SHALL COMPLY WITH THE SPECIFICATIONS AND CODES INDICATED IN THE DESIGN CRITERIA. SHEATHING SHALL BE IN ACCORDANCE WITH PS 1-95/ANSI A 199.1. ALL SHEETS BEAR APPROPRIATE GRADING STAMP OF APA AND SPAN RATING. PROVIDE 1/8" SPACE AT PANEL EDGES AND END JOINTS UNLESS OTHERWISE NOTED. LUMBER 2-INCH OR LESS IN NOMINAL THICKNESS AND SHEATHING SHALL NOT EXCEED 19% MOISTURE CONTENT AT TIME OF INSTALLATION. AND SHALL BE STAMPED "S-DRY"; 'K-D , OR MC15". ALL LUMBER SHALL BE S4S. ALL WOOD MEMBERS EXPOSED TO WEATHER OR IN CONTACT WITH MASONRY, CONCRETE OR SOIL SHALL BE PRESSURE TREATED, OR HAVE APPROVED SEPARATING MATERIAL. ALL LUMBER SIZES NOTED AND SPECIFIED ON PLANS ARE NOMINAL SIZES UNLESS SPECIFICALLY INDICATED AS NET SIZE. pp UNLESS NOTED OTHERWISE, THE FOLLOWING MINIMUM LUMBER GRADES SHALL BE USED: G a. STRUCTURAL ROOFAND WALL FRAMING - #2 SYP. b. NON-STRUCTURAL WALL FRAMING - STUD GRADE SPF OR METAL STUDS. c. NONSTRUCTURAL FRAMING - #2 SPF. ). FASTENERS AND CONNECTORS USED ON UN -TREATED WOOD EXPOSED TO WEATHER SHALL BE HOT DIPPED GALVANIZED. J$f 4 FASTENERS AND CONNECTORS (INCLUDING TRUSS PLATES, NAILS, BOLTS, ANCHORS, ETC.) CONTACT WITH TREATED WOOD SHALL BE COMPATIBLE WITH THE TREATMET METHOD AA FOLLOWS: a. WOOD TREATED WITH DOT SODIUM BORATE (SBX) -MINIMUM G90 ZINC COATING. b. WOOD TREATED WITH ACQ-C OR ACQ-D (CARBONATE) OR OTHER BORATE (NON-D 7) MINIIvfIIk, G1851NCCOATING. t ," c. FOR ALL OTHER TREATMENT -COMPLY WITH THE RECOMMENDATIONS OF THE P �4VE WOOD SUPPLIER /OA+ d. STAINLESS STEEL CONNECTORS AND FASTENERS MAY BE USED FOR ALL TYPES OF TREATED WOOD WOOD FASTENING SHALL BEAS SPECIFIED IN THE DRAWINGS. FASTENING NOT SPECIFICALLY IDENTIFIED ON DRAWINGS SHALL COMPLY WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE. CONTRACTOR SHALL PROVIDEALL FASTENING DEVICES NECESSARYAND SUITED FOR EACH APPLICATION. FASTENINGS IN CONTACT WITH MOISTURE SHALL BE HOT -DIPPED GALVANIZED CONFORMING TO ASTM A-158-80. SHEATHING NAILS OR SCREWS SHALL BE DRIVEN SO THAT THEIR HEAD OR CROWN IF FLUSH WITH THE SURFACE OF THE SHEATHING. W Q C W W �. y W W .Wi O O O U O y O O� O IT Lo W N M r W N to (D O (0 = 0co c� ✓C �u-(D as =2Lo , I. LLLL OU QNN wui LJJI Z U NCO�� ow 4) cy) X W � 05000-WLU V a1 Zw Q00 04 QU Z°a(D im Z w uj!5z LL>Z w w CO ��'qge J Z t V coZD ¢� z ®Lu2° J Co Q (a�- U w V Z 06 2i co Q LJJ �Z0 Qz O w m U u) L_ -0 Q Q ry Z L L. rn � rn cam, 0 z O G U w U (n FL" V Vi 41000) 1�8 go 03/10/17 SHEET si OF 1 17-0086 PERMIT SET