HomeMy WebLinkAboutApproved PlansSWIMOUTS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE T 20" max. 8"--I 3 ft. 0 in. C:) N.T.S. T DEEP 30 ft. 7 in. Fv TILED STEP _EDGES CpLpR<.EO VAC L 18" MIN. ( ENTIRE PERIN W.L. #8 SOLID COPPER SOyB- SOIL WIRE W/APVR. -- - CLAMPS (ONE ON EACH 8 GAUGE SOLID COPPER SIDE OF POOL WIRE TOTAL) -- F_QUIPOTENTIAL ONDING GRID DETAIL PER WE C. 2011 SEC, 680.26 MINIMUM 18" FROM EDGE OF POOL (WHERE ADOPTED) AROUND ENTIRE POOL PERIMETER BURIED 4" TO 6" DEEP Id TERMITE TREATMENT REQUIREp r 6D TILED BENCH EDGE SKIMMER x1x6Z076T 2• DOOR AND WINDOW 81 FASCIA X ALARMS BY OWNER HEIGHT POOL BARRIER PER FRIG R4501.17.1- R4501.17.3 AND ANSI/NSPI-5-1995 SAFETY BARRIER PER FRC R4501.17.1- R4501.17.3 & ASTM5034-95, ASTM D3787- 89, ASTM 653-96 ?IPINGSCHEMATIC MUST HOLD35PSI FOR AT NOTE: POOL PUMP MOTOR LOCATED ABOVE - - EAST 30 MIN. '' ELECTRICAL DIAGRAM AND_GFI GRADE. PROVIDE SEPARATE CIRCUIT FOR (NO SCALE) OUTLET PER 201_1 NEC PUMP MOTOR(S)AND HEATER(S) ETC (NO SCALE) R SSUR RAIN TIGHT OUTDOOR NOTE: INSTALL 125V 15 FILTER GAUGE - LECTRICALPANEL AMP WEATHERPROOF (SIZED PER Loao) DUPLEX RECEPTACLE AT TO MAIN SERVICE PANEL IN GFI LEAST 10' AWAY AND RETURN LINE APPROVED ONDUIT(SIZED PER LOAD) OUTLET NOT MORE THAN 20' i TDOORTIME-C CK FROM THE INSIDE WALL PUMP WIRING TO POOL LIGHT OF THE POOL WASTE APPROVED CONDUIT PUMP MOTOR UL APPROVED DECK BOX SKIMME FOR DIRECT CONNECTIO NOTES: 2) SEPARATE TO WET NICHE POOL MUST BE AT )RAINS 36" LI) EAST I' FROMLTHEDINS DE WALL OF THE POOL \PART POOL LI HT SWITCH' CAL WIRING AND EQUIPMENT MUST INSTALLEID IN ACCORDANCE WITH THE I' UNDERWATER EITHER INDOOR OR 2008 EDITION OF THE NATIONAL ELECTRICAL O V LIGHT OUTDOOR CODE HAIR & LINT APPROVED WIRING IN 1" • (3) PROVIDE PROPER WORKING CLEARANCE CATCHER SCH 40 PVC W/ #8 BONDING CONDUCTOR SPACES FOR ELECTRICAL EQUIPMENT AS PER (COMPONENT OF PUMP) HO-26 OF NFPA 70 OUTSIDE ANGLE OF REPOSE F AND FURTHER = 4" THICK WALLS W/113 REBAR a 12" O.C. EACH WAY 3' TO 6' = 6" THICK WALLS W1#3 REBAR @ 12" O.C. EACH WAY 0' TO 3' = 8" THICK WALLS W/#3 REBAR @ 12" O.C. EACH WAY f Oft.- I O 6 aft. j j WW J / 2 aAV EXCAVATION INTO THE ANGLE OF REPB'SE IS ALLOWABLE PROVIDED: SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT • NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES • COMPACTION TEST OF THE BACKFILLED MARTIAL ARE PROVIDED AT C.O. OF THE SWIMMING POOL MISC.. NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT ARE WHERE DECK RAISED MW' ABOVE POOL G MAX WATER DEPTH )-10" MIN. Tq 12- li -MAX. B THESE LJ1NS AND ALL PROPOSED WOrhT ARE UBJECT TO ANY CORRECTIONS REQ IRED BYIFlELD INSPECTORS THAT YBII,NE .,:CESSARY:IKORD.4010 ' CO P4YW.H:�LI ACPP.UCARL!CODES: FUTURE w nq- si7 SEPTIC FVrFWE0 FOR d' n . E Tr�s?oN LOCATION 4v1L°` { �'1 DATE Y PLANS AND PET011T MUST BE KEPT ON JOO OR NO EVSPECTION WILL BE N.:ys-. EAD LINE EXISTING° „. CONCRETE 6~ SLAB' "' a cc w , in POOL PATIO WATER LEVEL FROM Z00 POWER 1" LIGHT SU PLY g CONDUIT NDERWATE NO UNDERWATEF LIGHT NICHE LIGHT DETAIL (NO SCALE) APPROVED GROUNDCLAMP CONTINUOUS BOND WIRE POOL FINISH COMMON TO POOL STEEL, RAILS & EQUIPMENT V ci I HEATER PREWIRE ONLY 'LOCATION OF GFI RECEPTACLE TO BE DETERMINED IN FIELD PER NEC 680 EQUIPMENT VERIFY PAD EXACT PER FBC LOCATION IN R4501.22 FIELD WITH SUPERVISOR CONCRETE DECK NOTE: REMODFROMMAIN OVERPOUR BEND INTO DI WELL POINT PLU(OR CAPTIDRAIN8ATTACAUXWHERE LINE WHEN EMAPPLICABLE POOL DETAIL AND CHATPER MVANST 11 .IA8-20 2.5" SUCTION UNE MAX 147 G.P.M. #8 GROUND WIRE HANDRAIL BONDING DETAIL WHERE APPLICABLE STEPS PER NATIONAL ELECTRICAL CODE I1. TREAD IS MIN. OF 10" WIDE. 2. RISER NOT GREATER THAN 12" EXCEPT IF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 3000 PSI. APPROVED WITH THE 2014 FLORIDA BUILDING CODE FOR RESIDENTIAL AND THE ANSI/APSP.7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE MINIMUM_(2j SUCTION LINES PER PUMP FT. SEPARATION OR SEPARATE PLANES___ 3 FT. MIN. 1 T LINE FIRST TEE. 1.5" TO POOL e File cc "",y x 0 APPROVED WITH THE 2014 FLORIDA BUILDING CODE 5TH EDITION FOR RESIDENTIAL SPECIFICATIONS MAX. WIDTH 13' MAX. LENGTH 24' MIN. DEPTH 3' MAX. DEPTH 5' SHAPE CUST ELEVATION T.B.D FILL FROM EXCAVATION HAUL TILE INTERIOR FINISH GEM FILTER CS200 PUMP MAKE PER FBC 4501.20 JANDY PUMP HP: POOL 1 HP VS FLO PRO SPA NA FILTRATION PUMP COMPLIANT WITH ANSIIAPSPIICC-15 2011 LIGHTS POOL 1 CLR LED SPA NA TRNFORM: POOL 300 WATT SPA NA MAIN DRAIN: POOL 2 SPA NA SKIMMER (1) TIMER INCL RETURNS: POOL 3 SPA NA JETS-. POOL SPA NA VALVED VAC LINE INCL FILL LINE NA DISCHARGE LINE TO GROUND CHLORINATOR JANDY T_RU CLEAR SALT HANDRAIL NA LADDER NA DIVING BOARD NA SLIDE NA HEATER PREWIRE ONLY VACUUM HEAD INCL POLE INCL VACUUM HOSE INCL BRUSH INCL LEAF SKIMMER INCL TEST KIT INCL TREE / STUMP REMOVAL NA REMOVE EXISITING CONCRETE NA PUMP POOL PATIO INCL SCREEN ENCLOSURE BY PIONEER ELECTRICAL INCL _ 3" PLUMBING LINES FROM POOL PATIO CONCRETE FLOCRETE SUMP W/3"TEE EXISTING PATIO NA D FILTRATION PUMP 6FPS MAX DECK DRAIN INC GALLON CAPACITY -POOL GAL. VS-FHP1.0 PERFORMANCE CURVES GALLON CAPACITY -SPA NA TURN -OVER RATE 6 hIS 100 TERMITE TREAT INC BARRIER INC 6p MAX.. WATER VELOCITY - _6 k./S FROM TRUNK LINES 2 p FILTRATION PUMP TO 8_k./s SUCTION LINES 10LQB MAX RETURN LINE LL SKIMMER MIN. -FLOW 25 GPM O 1D SURFACE AREA OF POOL - 265SQ. FT 66L_N FT 66 3450 RPM Q m W 2 40 V 21:.FN 1000 RPM ILT Q20 PUMPO-_:-._- 17301PM 10 HIGH Q SPEED (� NX 0 {- 0 10 20 40 s6 6o N 60 MI too 110 1m 130 140 too 160 170 IN 190 2 FILTRATI ON PUMP FLOW GPM LOWI CERTIFICATION OF COMPLIANCE SPEED I I MI (Dnten6: 1 - - - 140-231 v xIingPwn: ODend AnU-VaHex3unian0utle[ He, 6` ORGAw: 1133in' MR#Isfv 55fleMONXIIAC iWGPM YA4FIBSIM, 646PM OADHIamBIzdme IIEC 10 2 1/4" PER FT. SLOPE 6X6TIL 4" SLAB �� J� ' INTERIOR 2500 FIBERMEX GRATE SHALL FINISH TYPICAL WALL BE SECURED IN PLACE SO THATTOOLS ARE REQUIRED FOR REMOVAL PLUG SC GRAVELSED 6" TYP. /;LOOR �P TTO PUM -►P n" SECTION & WALLL WELL POINT (NO SCALE) STEEL-TEX FORM rR KRAFT WALL #3 @ 12" O.C.B.W. NOTE: FOR DEPTHS EATER THAN V ADD 1- I COVE BAR @ 6" O.C. ATWS WunNku (VOW) W Wd5N�E='v.�v E::.n R L 3. 1. SWIMMING PARL CONSTRUCTRN TO COMPLY WI FLA. BLDG, CODE MO WITH ALL LOCAL DfUM XUSR SEA ZONNGRR IATIONb. 3.8MMMNOPOOLYOBEARONROCKMUN MRBEDSRND.ALLW LSANO MSSHLLLDEGUNUED ON POURED WDLAW CONCRETE Be MMMUM 3SW P.B.L CONCRETE W A DANA) COMPRESSNE STRENGTH. 6. FOR WEEABXALL Be NOTIFIED IF SOIL WARM. LEW THAN NEW PAY, OR ROOM, SAY OR LOOSE. SOFT SOIL IS FOUND. A80RBENDHOCAPACIEYM 2}W MKS ARM MBEEN USED AS ME DESIGN. 4. RSMFORCMG BARS SMALL SE NEN GULLET. GFODE 40. 6.= POOL PIPING TO BE P.V.C. SCHEDULE 40 MF N. AND BEAR TEE N$APPROVAL. .BAD ,MA.L BE IN CGLIPUANW RATE LOCAL ORIANANCEA i. DISPOSAL OF POOL WATER SHALL CONFORM TO LOCAL ORDINANCES, SURFACE GRADING SHALL CONTAIN . M WIININ PROPERTY LE EG PYYUPG SHALL NOT NEARBY FOR MORE AN ONE HOUR. & WATER SUPPLY WSPOSAL MALL W6TALLED 60 THAT THERE IS NO CROSS CONNECTION WTOI A DOMESTIC WATER SUPPLY OR NAME DISPOSAL SYSTEM. e. GRATE AT MAIN IXGW SHALL HAVE A FREE AREA OF 4X THE AREA OF MESUCTNIN LINE f 0. MAm STINT STEMNER3 SHALL HAVE A REMOVABLE SCREEN WI A MRllMUS FREE AREA OF SX THE AREA OF THE SUCTION LINE. It ELECTRICAL: WSEALL PREFER& DEV ES AS SHOWN IN 'POOL DATA' HEREDN. LIGHT CONNECTION TO CONFORM TO NATIONAL EIELTUCAL CODE. LLTESTB ITAIN. 12. ALL MFTALLMAMULin. PPINO SYSTEM!, REWFORCED STEEL. WHT FUTURES S HOUSING, METAL ARTS OF LARDERS. MANBRANS, OWING BOARDS& SUPPORTS TO BE BONDED TOGETHER S GROUNDED TO COMMON GROUND. DEWLAP! CONDUCTOR SMALL NOT BE SWUNG MAN W COPPER. 13. NO WERHEADOPEN WIRE OVER POOL WATER. CARTRIDGE FlLTER MALL HAVE A FILTRATION RATE MOTTO EXCEED 3 O.P.M. I S.F. OP FILTER AN U. NO RAW...REOU., 1S. CGNT ACTORSHALLVERIFF ALL DFM UV UOW AND CONDITIONS AT SITE BEFORE STARTING THE PROJECT. CONTRACTORSHALLVERIFY LOCATION OF ELECTEICAL SUNG! By' '11. CONSPANY. 16. SPEC W L ATIENTKKI SHALL BE GIVEN TO EXISTING FOUNDATION TO PPENT UNDER.... JOB NAME: SMITH ADDRESS:759 ALTURA ST PSL 34952 PERMIT NO.: DATE DRAWN:MARCH 13TH 2O17 DRAWN BY: BOBBY AUSTIN DESIGNER APPROVAL: CUSTOMER APPROVAL: SCALE: 1/4" = 1' RAY REINHARD PE # 47041 RIPCOOLS, 1010 Easter Lilly Lane Unit 203 Vero Beach, FL 32963 COIV omm 1 t INC. 1 ROW OF WATERLINE TILE STEEL @ 12" O/C E.W. FLOOR SLOPES" FLOOR SLOPES SHALL BE REASONABLY UNIFORM AND COMPLY WITH ARTICLES 6.6.1 THRU 5.6.3 CYCOLAC MAIN THE SLOPE OF THE FLOOR FROM 2V THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL " 24' TYPICAL SECTION THRU POOL (NO SCALE) 5' `I"" WALLS SHALL NOT 6" THICK SLOPE GREAITER THAN 11' 3'