Loading...
HomeMy WebLinkAboutCompaction Test (2)Headquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #:210335-1d/SS/ct PERMIT #:NUC #215 CONTRACTOR:Dave Golden Homes Nuc Model:MC-1DR-P JOB LOCATION:3601 Arnold Road Nuc Serial #:MD80404215 Fort Pierce, Florida ITEM TESTED:Compacted Foundation Fill - 2nd & Final Lift TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. N.E.24" - 36"40 108.9 111.8 97.4% 2. Center "38 107.4 "96.1% 3. S.W."41 107.8 "96.4% 4. S.E.12" - 24"42 108.0 "96.6% 5. Center "44 109.0 "97.5% 6. N.W."46 109.2 "97.7% Soil Description: Brown Sand with Clay In Place Moisture: 12.8% Proctor Optimum Moisture: 13.0% Proctor Max. Dry Density: P.C.F. 111.8 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 1/22/2021 Email to: dave@davegoldenhomes.com SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 January 21, 2021 2010-0527 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. Proudly Serving Florida since 1990 108.0 109.0 110.0 111.0 112.0 113.0 10 11 12 13 14 15 16 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight