Loading...
HomeMy WebLinkAboutcompactionHeadquarters 11345 U.S. Highway 1 Sebastian, FL. 32958 Orlando 723 Progress Way Sanford, FL. 32771 Mailing PO Box 78-1377 Sebastian, FL. 32978 Phone: 772-589-0712 C.A.# 5693 KSMengineering.net DATE TESTED:KSM JOB #:210573-1d/SS/ct PERMIT #:NUC #215 CONTRACTOR:Adams Homes Nuc Model:MC-1DR-P JOB LOCATION:5345 San Benedetto Place Nuc Serial #:MD80404215 Lot 12, Block 5, Waterstone Fort Pierce, Florida ITEM TESTED:Compacted Foundation Fill TEST LOCATION OF SAMPLE DEPTH PEN READ DRY DENSITY MAX. DRY PROCTOR VALUE (P.C.F) PERCENT COMPACTION 1. S.W.0" - 12"50+112.8 113.7 99.2% 2. N.W.""111.2 "97.8% 3. Center ""110.4 "97.1% 4. N.E.""110.7 "97.4% 5. S.E.""111.6 "98.2% 0.0 Soil Description: Brown & Tan Sand with Clay In Place Moisture: 8.8% Proctor Optimum Moisture: 12.0% Proctor Max. Dry Density: P.C.F. 113.7 @ Test Locations the Density & Penetrometer readings indicate the Degree of Compaction Meets Minimum Requirement for Staked Foundation Respectfully Submitted: Bryan E. Dahlke, P.E. V.P. of Engineering PE # 81439 1/22/2021 Email to: rickjohnson@adamshomes.com; St. Lucie County Building Department Proudly Serving Florida since 1990 Disclaimer:Contractor is responsible to maintain the tested area in the condition that KSM completed the indicated passed compaction test. KSM is not responsible if the tested area has been altered from the approved inspected condition. SOIL COMPACTION REPORT ASTM D 1557 and ASTM D 6938 January 21, 2021 2011-0382 110.0 111.0 112.0 113.0 114.0 115.0 9 10 11 12 13 14 15 W E I G H T P . C . F . D R Y Moisture -% of Dry Weight