Loading...
HomeMy WebLinkAboutSurvey3-1 V Ac NS SET 5/8"IR/C\ LB 4286 (TYP) SANITARY SERVICE PROPOSED AC PAD SET 5/8" IR/C LB 4286 (TYP) N 2.0 LO � 0.6 �. PROPOSED CO 3 8 ENTRY �68 PROPOSED MODEL 4EAB/C F.F.E.=18.62 a+� GARAGE F.F.E.=18.00 EXISTING BUILDING PAD EL=18.47 P' N; (� POSED COVERED LANAI ++ J N 39 VACANT 6 SET 5/8" IR/C LB 4286 (TYP) 7.672.00'J oo) 0.67' \ MIN. SETBACK SIDES CNR SIDES REAR ZNG. LEGEND & ABBREVIATIONS TECH. BB DENOTES BEARING BASE N/D DENOTES NAIL AND DISK CBS DENOTES CONCRETE BLOCK STRUCTURE O.S.T. DENOTES OPEN SPACE TRACT C DENOTES CHORD BEARING do DISTANCE P.S.M. DENOTES PROFESSIONAL SURVEYOR do MAPPER DENOTES CENTER LINE P.L.S. DENOTES PROFESSIONAL LAND SURVEYOR D.E. DENOTES DRAINAGE EASEMENT F.F.E. DENOTES FINISH FLOOR ELEVATION R DENOTES RADIUS FND DENOTES FOUND R/W DENOTES RIGHT OF WAY IR/C DENOTES IRON ROD AND CAP U.E. DENOTES UTILITY EASEMENT L.B. DENOTES LICENSED BUSINESS W.M.T. DENOTES WATER MANAGEMENT TRACT L DENOTES ARC LENGTH A DENOTES INCLUDED ANGLE DENOTES DRAINAGE FLOW DENOTES PROPOSED ELEVATION WATER \ j SERVICE 1 SET 5/8" IR/C \ LB 4286 (TYP) \ SANITARY �C O \\�\: \ \ (p, O_ RIM EL=16.07' N.A.V.D. 1983 \ AREA SUMMARY IN SQUARE FEET SOD:4,907 f DRIVEWAY/WALKWAY:618 f PROPERTY ADDRESS 3342 TRINITY CIRCLE, FORT PIERCE, FLORIDA LEGAL DESCRIPTION GRAPHIC SCALE 20 0 10 20 (IN FM) 1 inch - 20 & Being all of Lot 38, according to the plat of CREEKSIDE PLAT NO. 4, as recorded in Plat Book 85, Page 5, Public Records of St. Lucie County, Florida. Containing 0.175 acres, more or less. GENERAL NOTES 1. The last date of field work was 5-14-20 2. Additions or deletions to survey maps or reports by other than the signing party or \ parties is prohibited without written consent of the signing party or parties. 3. Reproductions of this map are not valid without the original signature and raised seal of - a Florida Licensed Surveyor and Mapper. \ 4. Lands shown hereon were not abstracted by this office for rights —of —way, easements of record, ownership, abandonment's, deed restrictions, or Murphy Act Deeds. This information should be obtained through appropriate title verification. 5. All above ground fixed improvements, if any, have been located and shown hereon. 6. Underground foundations and improvements were not located as part of this survey. 7. Flood Note: By graphic plotting only, this property is in Zone X and AE 16.9, according to the Flood Insurance Rate Map, Community Panel No. 12111CO170 J, effective date February \ 16, 2012. The exact designation can only be determined by an elevation certificate. No additional search of the public records has been preformed. There may be additional map \Amendments affecting this property. 8. The Flood Zone lines shown hereon have been established by the Published FEMA Panel and the use of existing field elevation data. 9. The bearings shown hereon are based on Plat information and are referenced to the center line of Trinity Circle which bears North 75'07'12" East and all bearings are relative thereto. 10. No easements are shown hereon other than those depicted on the plat. No search of the public records has been performed to find additional easements that may exist. 11. Elevations shown hereon are based on the North American Vertical Datum (N.A.V.D.) 1988. \ 12. The building setbacks shown hereon, although based on the best available information, are not certified to and must be verified prior to design or construction. FILE COPY Is THOMAS P. KIERNAN DATE Professional. Surveyor & Mapper w Florida Certificate No. 6199 p