HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING'CONSTRUCTION
Florida Department of Business and -Professional Regulation - Residential Performance Method
ProjectName: WYNNE_THE WINDSOR IMPACT
BuilderName: WYNNE. DEVELOPMENT
Street: \ �CLV-0,%-t- \
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PermitNumber:
Owner:
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans).
9. Wall Types .(1432.0 sqft)
Insulation. Area
2. Single farr My or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1224.00 ft2
b. Frame -.Wood, Adjacent
'R=11.0 208,00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ftZ
4. Number of Bedrooms i3
d. N/A
R= ftZ
5. Is this a worst case? Yes
10. Ceiling Types (1783.0 sqft.)
Insulation Area
a. UnderAttic (Vented)
R=30.0 1753.00 ftz
6. Conditioned floor area above grade (ftZ) 1753
b. Knee Wall (Vented)
k=19.0 30.00 ftZ
Conditioned floorareabelowgrade(ftZ) 0
c. N/A.
R= ftz
11.: Ducts
R ftZ
7. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: SO, U=1.04 111.36 ftZ
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.60 ftZ
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 . SEER:15.00
c. U-Factor: N/A ftZ
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftZ
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.285
14. Hot water systems
8. Floor Types (1753.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab-On-Grade.EdgeInsulation R=0.0 1753.00ft'
b. Conservation features
EF:0.970
b. N/A R= ftZ
None
c: NIA R= ftZ
15..Cre.dits
Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads.: 52.17
PASS
Total Baseline Loads: 53.92
hereby certify that the plans and specifications covered by
Review of the plans and
O,- ,
this calculation are in compliance with the Florida Energy
specifications covered by this
'
Code.
calculation indicates compliance
with the Florida Energy Code.
PREPARE 13y:
DATE: - _
Before construction is. completed
this building will be inspected for
compliance with Section 553:908
I he certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
vs
OWNER/AGERT:
BUILDING OFFICIAL:
DATE. �O
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified :factory -sealed in accordance with R403.3.2.1.
Compliance requires an Air Barrier and Insulation Inspection..Checklist in accordance with R402.4.1.1-and this project requires
an envelope leakage test report with envelope leakage no greater than 5.00 ACH50 (R402.4.1.2).
4/21 /202010:04 AM EnergyGauge® USA 6:0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms: 3
Address Type:
Street Address
Building Type: User
ConditionedArea: 1753
Lot#
OwnerName:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
BuilderName: WYNNE DEVELOPMENT RotateAngle: 0
Street:
Permit Office: ST. LUCIE COUNTY
CrossVentilation: No
County.
St. Lucie
Jurisdiction:.
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
FamilyType: Single-family.
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design DailyTemp
DesignLocation
TMY Site 97.5 % 2.5 %
Winter
Summer
Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI.. 39 90
70
75
299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1753 14024
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID.
Finished Cooled
Heated
1 MASTER BEDROO
224 1792 No 0
1
1
Yes
Yes
Yes
2 WIC
63 504 No 0
1
No
Yes
Yes
3 MASTER BATH
56 448 No 0
1
Yes
Yes
Yes
4 M.BATH
61 488 No 0
1
Yes
Yes
Yes
5 LAUDRY
36 288 No 0
1
No
Yes
Yes
6 BEDROOM 2
180 1440 No 0-
1
1
Yes
Yes '
Yes
7 DINING/GREAT.RO
588 4704 No 2
1
Yes
Yes
Yes
8 KITCHEN
209 1672 Yes 0
1
Yes
Yes
Yes
9 BATH
50 400 No 0
1
Yes.
Yes
Yes
10 HALL
25 200 No 0
1
No
Yes
Yes
11 FOYER.
92 736 No 0
1
Yes
Yes
Yes
12 BEDROOM 3
169 .. 1352 No 0
1
1
Yes
Yes
Yes
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1Slab-On-Grade Edge Insulation
MASTER BEDRO 37ft 0
224 ft2
____
.0 1
0
2Slab-On-Grade Edge Insulation
WIC 1 ft 0
63ft2
____
0 1
0
3 Slab -On -Grade Edge Insulation
MASTER BATH 8 ft 0
56 ft2
____
0 1
0
4Slab=On-Grade Edge lnsulation
M. BATH 7 ft 0
61 ft2
____
0 1
0
5Slab-On-Grade Edge Insulation
LAUDRY 1 ft 0
36ft2
____
0 1
0
4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# FloorType
Space Perimeter PerimeterR-Value Area
JoistR-Value
Tile Wood Carpet
6Slab-On-Grade Edge Insulation
BEDROOM 2 12 ft 0-
180 ft2
____
0 1
0
7Slab-On-Grade Edge insulation
DINING/GREAT 50'ft 0
588ft2
____
0 1
0.
8Slab-On-Grade Edge Insulation
KITCHEN, 111ft 0
209ft2
___
0 Y
0
9 Slab -On -Grade Edge Insulation
BATH 5 ft 0
50 ft2
____
0 1
0
108Iab-On-Grade Edge Insulation
HALL 1 ft 0
25ft2
____
0 1
0
11SIab-On-Grade Edge lnsulation
FOYER 9 ft 0
92 ft'
____
0 1
0
12SIab-On-Grade Edgelnsulation
BEDROOM 3 14 ft 0
169 ft2
____
0 1
0
ROOF
/
Roof Gable
Roof. Rad
Solar
SA Emitt
Emitt. Deck
Pitch
# Type Materials Area Area
Color Barr Absor.
Tested
Tested Insul.
(deg)
1 Hip Metal 1.847 ft2 0 ft2
Light N
0.4
No 0.9
No 0
18.4
ATTIC
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented 150 '
1753 ft2
N
N
CEILING.
# CeilingType
Space R-Value
Ins Type
Area
Framing Frac
Truss Type .
1 UnderAttic (Vented)
MASTER BEDRO 30
Blown
224 ft2
0.1
Wood
2 UnderAttic(Vented)
WIC 30
Blown
63ft2 -
0.1
Wood
3 UnderAttic (Vented)
MASTER BATH 30
Blown
56 ft2
0.1
Wood
4 UnderAttic(Vented)
M. BATH 30
Blown
61 ft2
0.1
Wood
5 Und&Attic(Vented)
LAUDRY 30
Blown
36ft2
0.1
Wood
6 UnderAttic (Vented)
BEDROOM 2 30
Blown
180 ft2
0.1
Wood. .
7 UnderAttic(Vented)
DINING/GREAT 30
Blown
588ft2
0.1
Wood
8. UnderAttlG(Vented)
KITCHEN 30
Blown
209ft2
0.1
Wood
9 UnderAttic (Vented)
BATH 30
Blown
50ft2
0.1
Wood
10 UnderAttic(Vented)
HALL '30
Blown
25ft2
0.1
Wood
11 UnderAttic(Vented)
FOYER 30
Blown
92ft2
0.1
Wood
12 UnderAttic(Vented)
BEDROOM 30
Blown
169ft2
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT 19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent
Space. :Cavity Width
Height
Sheathing Framing Solar Below
1
E Exterior Concrete Block-
Int InsuMASTER BE 4.1 16
0 8 0
128:0 ft2
0 0
0.3
0
2
W Exterior Concrete Block-
Int InsuMASTER BE 4.1, 7
0 8 0
56.0 ftz
0 0
0.3
0
3
S Exterior Concrete Block -
Int InsuMASTER BE 4.1 14
0 8 .0
112.0 ft2
0 0
0.3
0
4/21 /202010:04 AM EnergyGauge@ USA 6.0.02 (ReV.1) - FlaRes2017: FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORMR405-2017 INPUT SUMMARY r141=rK1 icr RGanQT
WALLS
Adjacent Space Cavity Width
In
Height
Ft In
Aran
Sheathing. Framing
_
Solar Below
o
4
E
Exterior Concrete Block- Int InsuMASTER BA 4.1 8
0
8 0
64.0 ftz
0.
0
0.3
_
0
5
E
Exterior Concrete Block - Int lnsul M. BATH 4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
6
E
Exterior Concrete Block - Int InsuBEDROOM 2 4.1 12
0
8 0
96.0 ftz
0
0
0.3
0
_ 7
S
Exterior Concrete Block- Int InsuDINING/GRE 4.1 30
0
8 0
240.0 ftz
0
0
0.3
0
8
- W
Exterior Concrete Block- Int InsuDINING/GRE 4.1 20
0 _
8 0
160.0 ft?
0
0
0.3
0
9
W
Exterior Concrete Block- Int insul KITCHEN 4.1 11
0
8 0
88.0 ftz
0
0
0.3
0
10
E
Exterior Concrete Block- Int Insul BATH 4.1 5
0
8 0
40' ftz
0
0
0.3
0
11
N
Exterior Concrete Block- Int Insul FOYER 4.1 8
0
8 0
64.0 ftz
0
0
0.3
0
12
N
Exterior Concrete Block- Int1nsul FOYER 4.1 1
0
8 0
8.0 ftz
0
0
0.3
0
13
W
Exterior Concrete Block- Int InsuBEDROOM 3 4.1 13
0
8 0
104.0 ftz
0
0
0.3
0
14
N
Exterior Concrete Block - Int IrisuBEDR00M3 4.1 1
0
8 0
8.0 ftz
0
0
0.3
0
_15
N
Garage Frame - Wood BEDROOM 3 11 26
8
208.0ft2
0.23
0.3
0
DOORS
#
Omt - DoorType. Space Storms
U-Value
Width
Height
Area
Ft
In'
Ft In
1
N Insulated FOYER None
.32
3
$
6 8
21.7 ftz
WINDOWS
Orientation shown is the entered orientation. _> chap
ed to Worst Case.
/
Wall
Overhang
Ornt ID Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1
'S
$ Metal Low-ESingle Yes 1.04 0.29
N
32.4 ftz
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exteriors
2
E
5 Metal Low-ESingle Yes 1.04 0.29
N
6.9 ft'
1 ft 0 in
1 ft 5 in
None
None
3'
E
6 Metal Low-ESingle Yes 1.04 0.29
N
16.2 ftz
1 ft 0 in
1 ft 5 in
None
None
4
S
7 Metal Low-ESingle Yes 1.04 0.29
N
39.8 ftz
1 ft 0 in
1 ft 5 in
None
None
5
W
8 Metal Low-ESingle Yes 1.11 0.27
N
40.0 ft'
8 ft 0 in
1 ft 5 in
None
None
6
W
13 Metal Low-ESingle Yes 1.04 0.29
N
16.2 ft'
1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior5
GARAGE
#
FloorArea CeilingArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation.
1
806 ftz 806 ft? 26 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse
ProposedACH(50) .000254 1168.7 64.16
120.66
.0881
5
4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 CentralUnit/
Split
Single SEER:15
34.8 kBtu/hr cfm 0.85 1
sys#1
HOT WATER SYSTEM
# . System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.97 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # CompanyName
-SystemModel# CollectorModel#
Area Volume
FEF
None None
ftz
DUCTS
/ ---- Supply----
I/
---- Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area LeakageType
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic 6 175 ftz Attic
55 ftz DefaultLeakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
Cooling Jan Feb Mar
Heating Jan Feb �J Mar
Venting
Apr
f Apr f
Ma Jun Jul
Jul
May Jun njul
Auge
M Auns
SeP
Oct Nov
Oct X�J Nov
Dec
Dec;
Jan Feb [X] Mar
[X] A r [
Ma Jun
Aug
e
Lx] Oct [xl Nov
Dec'
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType 1
2 3
4 5 6
7
8
9 10 11
12
Cooling (WD)' AM 78
78 78.
78 78 78
78
78
80 80 80
80
PM 80
80 78
78 78 78
78
78
78 78 78
78
Cooling (WEH) AM 78
78 78
78 78 78
78
78
78 78 78
78
PM 78
78 78
78 78 78
78
78
78 78 78
78
Heating(WD) AM 66
66 66
66 66 68
68
68
68 68 68
68
PM 68
68 68
68 68 68
68
68
68 68 66
66
Heating (WEH) AM 66
66 66
66 66 68
68
68
68 68 68
68
PM 68
68 68
68 68. 68
68
68
68 68 66
66
MASS
Mass Type
Area
Thickness Furniture Fraction
Space
Default(8lbs/sq.ft.
0 ftz
0 ft
0.3
MASTER BEDROO
Default(81bs/sqft
ft2
ft
0.3
WIC
Default(8lbs/sq.ft.
ftz
ft
0.3
MASTER BATH
Default(81bs/sq.ft.
ftz
ft
0.3
M. BATH
Default(8lbs/sq.ft.
ftz
ft
0.3
LAUDRY
Default(8lbs/sq:ft.
ftz
ft
0.3
BEDROOM 2
-Default(81bs/sq.ft.
ftz
ft
0.3
DINING/GREAT RO
DefaUlt(8lbs/sq.ft.
ftz
ft
0.3
KITCHEN
4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017
INPUT. SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area Thickness Furnitur.aFraction
Space
Default(8lbs/sq.ft.
ftz ft 0.3
BATH
Default(8lbs/sq.ft.
ftz ft 0.3
HALL
Default(8lbs/sq.ft.
ftz ft 0.3
FOYER
Default 8lbs/s .ft.
ftz ft 0.3
BEDROOM.3
4/21/202010:04 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND.INSULATION INSPECTION COMPONENT CRITERIA
TABLE:4024.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE COUNTY
City; State, Zip: FT. PIERCE, FL,' Permit Number:
Owner: Jurisdiction:
w
Design Location: FL, Fort Pierce
9
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A.continuous air barrier shall be installed in the building :envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealingmaterial.
. Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned'with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls.shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framingshall 'be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including,
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned s ace shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and. conditioned spac
Ds.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope.
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls -adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on.extedor wall
tubs shall separate them from the'showers.and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication ,
exterior walls
lioxes.or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots -that penetrate building thermal envelope shall
be sealed to the sub -floor or'drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
-- fire sprinkler cover plates and wallsor cellina�.
a..In addition, inspection of log walls shall be in accordance: with the provisions of ICC-400.
4/21/202010:05 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant. Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family 2. Single-family, b) Return ducts . R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family) 3. 1
4. Number of bedrooms 4. 3 13. Cooling system: Capacity
34.8
a) Split system SEER
15.0
5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 1.058
b) Solar Heat Gain' Coefficient (SHGC) 7b. '0.285
c) Area 7c. 151.4
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab-on=grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2: Masonry (Insulation R-value)
B. Adjacent: .
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type. and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
9a. 0.0
9b.
9c.
10A1.
10A2. 4.1
10131. 11.0
10B2.
11 a. 30.0
11 b.
11c. 19.0
11 d. No
14. Heating system:.
Capacity 34.8
a) Split system heat pump
HSPF 8.5
b) Single package heat pump HSPF
c) Electric resistance
COP
d) Gas furnace, natural gas
AFUE
e) Gas furnace, LPG
AFUE
f) Other
15. Water heating system
a) Electric resistanceEF 0.97
b) Gas fired, natural -gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with.tank EF
f) Heat recovery unit HeatRec%
g) Other
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
b). Cross ventilation No
c) Whole house fan No
d) Multizone cooling credit
e) Multizone heating credit
f) Programmable thermostat Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
certify that this home has complied with the Florida Building Code; Energy .Conservation, through the above,energy
saving features which will be installed (or exceeded): in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address:of New Home: \ E.- C_- City/FL Zip: FT. PIERCE, FL
4/21/202010:05:25 AM EnergyGauge® USA 6.0.04.(Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1