HomeMy WebLinkAboutBUILDING PERMITAll APPLICABLE INFO MUST BE COMPLETED FOR APPLICATION TO BE ACCEPTED
Date: 01 /25/2021
Permit Number:
E11doC,?� ��� `
h 11 c ul� Building Permit Application
Planning and Development Services
Building and Code Regulation Division Commercial Residential X
2300 Virginia Avenue, Fort Pierce FL 34982
Phone: (772) 462-1553 Fax: (772) 462-1578
PERMIT APPLICATION FOR: WATER HEATER REPLACEMENT - LIKE KIND
PROPOSED IMPROVEMENT LOCATION: 8404 WINTER GARDEN PARKWAY
Address: 8404 WINTER GARDEN PARKWAY, FORT PIERCE, FL 34951
Property Tax ID #: 1301-605-0355-000-7 Lot No.3
Site Plan Name: LAKEWOOD PARK -UNIT 5- BILK 55 LOT 3 (MAP 13102S) (OR 2595-2413) Block No. 55
Project Name: SeelTowniRange: 021343139E
DETAILED DESCRIPTION OF WORK:
REPALCE LIKE KIND 50 GALLON ELECTRIC IN GARAGE
New Electrical Meter N/A Second Electrical MeterN/A
CONSTRUCTION INFORMATION:
Additional work to be performed under this permit— check all that apply:
Mechanical _ Gas Tank _ Gas Piping _ Shutters Windows/Doors Pond
_ Electric ,( Plumbing _ Sprinklers ! Generator , Roof Pitch
Total Sq. Ft of Construction: Sq. Ft. of First Floor:
Cost of Construction: $ 2,200.00 Utilities: —Sewer —Septic Building Height:
OWNERAESSEE:
Name PAUL OR DONNA LUTZE
Address: 8404 WINTER GARDEN PARKWAY
Citv: FORT PIERCE Stater
Zip Code: 34951 Fax: N/A
Phone No. 772-559-0287
E-Mall:DONLU 44@YAHOO.COM
Fill in fee simple Title Holder on next page ( if different
from the Owner listed above)
CONTRACTOR:
Name.MATT BLACK
Company:BENJAMIN FRANKLIN PLUMBING
ArirIrPSS'6945 NW LTC PARKWAY
City: PORT SAINT LUCIE State: FL
Zip Code: 34986 Fax: 772-871-9069
ohnna Nn772-871-9494
E-Ma i I PERMITS@BENFRANKLINPLUMBER.COM
State or County LicenseCFC-1430437
If value of construction is 2500 or more, a RECORDED Notice of Commencement is required.
if value of H"C is $7,500 or more, a RECORDED Notice of Commencement is required.
SUPPLEMENTAL CONSTRUCTION LIEN LAW INFORMATION:
DESIGNER/ENGINEER: x Not Applicable MORTGAGE COMPANY:
Name:_
Address:
City:
Zip:
Phone
State
FEE SIMPLE TITLE HOLDER: x Not Applicable
Name:
Address:
City-
Zip: Phone: -
Name: —
Address:
City:
Zip:
Phone:
Not Applicable
State:
BONDING COMPANY: x Nat Applicable
Name:_
Address:
City:
Zip:
Phone:
OWNER/ CONTRACTOR AFFIDVIT: Application is hereby made to obtain a permit to do the work and installation as indicated.
I certify that no work or installation has commenced prior to the issuance of a permit.
St. Lucie County makes no representation that is granting a permit will authorize the permit holder to build the subject structure
strtucture. Pleasecconsult w with your Home Home Owners
Association nd review your deed for any restrict that
which maor
aprohibit such
In consideration of the granting of this requested permit, I do hereby agree that I will, in all respects, perform the work
in accordance with the approved plans, the Florida Building Codes and St, Lucie County Amendments.
The following building permit applications are exempt from undergoing a full concurrency review: room additions,
accessory structures, swimming pools, fences, walls, signs, screen rooms and accessory uses to another non-residential use
WARNING TO OWNER: Your failure to Record a Notice of Commencement may result in paying twice for
improvements to your property: A Notice of Commencement must be recorded in the public records of St.
Lucie County and posted on the jobsite before the first inspection. If you intend to obtain financing, consult
with lender or an attorney before commencing work or recording our Notice of Commencement.
Signature of Owner/ Lessee/Contractor as Age or Owner
STATE OF FLORIDA A�
COUNTY OF_ �(Lt
Sw n to (or affirmed) and subscribed before me of
'— Physical Pre ence or Online Notarization
this IL day o , 202b by
MATT f3�
Name of person making statement.
Personally Known OR Produced Identification
Type of Identification
Produced
(Signature f,4 y Pubu,�kt, yltLt-A 1r&a 1
• Notary Public • State of Florida
Commission N HH 491 I
Commissio pEofn>m�cpires Oct t,�2Dl�
Banded throuo National Notary Assn.
Signature of Contractor/License Holder
STATE OF FLORIDA`,ft. a
COUNTY OF
Sworryto (or affirmed) and subscribed before me of
Physical Presence or Online Notarization
this 2 3 day of 2021f by
_ /-n f4 11
Name of person making statement.
Personally Known-/ OR Produced Identification
Type of Identification
Produced
r
(Signatur ri'rly PuUi t�
Notary Public - State of Flori
Commission M HH 49824�14
Commissi ri -emims Oct t, 20 Bonded through Nationa[ Notary As
REVIEWS FRONT ZONING SUPERVISOR PLANS VEGETATION SEATURTLE MANGROVE
COUNTER REVIEW REVIEW REVIEW REVIEW REVIEW REVIEW
DATE
RECEIVED
DATE
COMPLETED
BRAS Mitbi MITE
W A T E R H E A T E: Ft S
Residential Upright
Energy Saver Electric Water Heater
Photo is of
M-2-50T6DS
Copper Screw Type Immersion Element
{ncWny type rnmarsxm elegwt ava"We UPW eMlies!j
The upright Electric Models Feature:
■ DOE —All residential storage models meet or exceed efficiency
requirements of the Department of Energy, ASHRAE Standard 90.1 b
(current standard) and the nservation Act of
1987 recent amendment National
dment effecita Janpuary 20, 2004 whiptiance Energy ch supe cedes all
state and Focal efficiency requirements.
■ Fully Automatic Controls ---Fast acting surface -mount thermostats for
automatic temperature control. Factory installed sensitive manual reset
energy cutoff for safety to prevent overheating.
■ Direct Heat Transfer With Immersed Elements —Transfers heat directly
and off iciently to the water. Screw -in style-
■ Factory Installed Hydrojet" Total Performance System —Cold water inlet
sediment reducing device helps prevent sediment build up in tank. Increases
first hour delivery of hot water wNle minimizing temperature build up in tank.
■ Vtraglas" Lining —Bradford White tanks are lined with an exciusively
engineered enamel formula that provides superior tank protection from the
highly corrosive effects of foot water This formula (Vitraglas°) is fused to the
steel surface by firing at a temperature of over 1600-F (871-C)
■ 2" Non-CFC Foam Insulation —Covers the sides and top of the tank,
reducing the amount of heat loss. This results in less energy consumption,
improved operation efficiencies and jacket rigidity.
a Water Connections— 3V4" NPT factory installed true dielectric fittings
extend water heater life and eases installation (M-2-120F3 has 1" NPT
dielectric Waterway fittings).
■ Factory Installed Heat Traps --Resign incorporates a flexible disk that
reduces heat loss in piping and eliminates the potential for noise generation;
(Except M-2-120R).
■ protective Magnesium Anode Rod --Provides added protection against
cnrrosion far iong trouble-frer ,ervice.
■ Simultaneous and ikon -Simultaneous operation Available ---
Simultaneous operation indicates when both elements (if equipped) are
being heated at the same time. )Von -Simultaneous operation indicates when
one element is being heated at a time.
■ Voltages Available-120V, 208V. 240V, 2 (1V, 480V.
■ Single Phase or Three Phase Operation Available-277V may only to
wired for single phase operation.
1 UP Relief Valve Included --All models have special tapping on top of
tank.
■ Low Restriction Brass Drain Valve —Durable tamper proot design.
■ Design evaluated by ETL in accordance with Part 280,707(d) of HUD
Mobile Home Construction and Safety Standards for Energy Efficiency,
At rourroor,11
6 or 10-rear Limited Tank Warranties / 6 or 10-Year Limited Warranty an Component Parts.
(M.0
/����►� ���/}��j . For more information on warranty, please visit vd�vw.lxadfordlvFalte.cnrrl
�y" `\`!! " Fear products ,nstal,ed n USA, C970ia anc: f'uarto R+aa. Sarne states do not Rrrc.v o-nu .atrans On warranties '9" canrp7efe
i; sWrek brae tek , W . copy : f the wamanry ork.rded with the heater,
145,385,
MARUMAO AED UNDER am OR Mf7RE CP THE FOLLOWING U.S. 1ATENFS: $.95e,d92: 5.161.379; 5943.m: 5.0al W, 5,9M.117, 6,142,21b; a.5,574.b??: 933T.185, 3.485;9i9; 5,?r! l i1;
7.271pal32cor� 5.AIMFC4ESNPACKTA�PLCVIONSPEhQt40 CURfl_Nr ANAOr1WPAT448, LN1S•I777;tA tj79G.Do:1229918322G0052.2�1125"15�2.tJB K:.628,14 210761 �2.2.C@7gt45.2.479234 11
Wtraille and Hydrotm€- an sEqutered trademarttt 0 oraVord WHIP' Cerprati2n. 201 6 0213-A
Residential Electric Water Neater
Upright Eno gy Saver Models C.E.C.Lisled
Recovery A D c D Apprer.
Model Capacity g0F ' Rise I Floor to JIB Floor to Floor to Shipping
Number i listior Ota. Water T&P Weighl
Tot+ cow. Conn.
O.S. impp. U.S. itnpp.
all, 6vt. GPH• GPti' in. 11€. in. in. Ibs.
M-2.30R603 30 25 21 18 461h 18 48�h 47�1ew -" 853
M 2 405SDS AO 33 21 18 4lrfs 1 20 i 477s 46'Is _
M-240T6D5 4D 33 21 18 59'h 18 wi- 6914
IN-2.50S5D51 50 42 21 18 46'1 22 41 fr 4li'12 130~ —
M-2-SOT60S 50 42 21 18 571h � 20 � 581h _ 57112 123
Al2 85R6i75
65 54 21 18 591t. 22 50'r. 59'!, 15fi
M-2-BOi�DS 80 67 71 1a i 59'7. 183
24 fi0ih 5911� - 305
M•24VR60S 119 99 21 i3 62312 25 64'r, 621A
Resove A 8 C 0 Apprcx.
Modal Capacity 5q•C R[se FWar to ) Avaket Fluor to Floor to Shrppinq
8vmber heater Div. Water TdrP Weigh
Top Gong, Conn•
Liters!
Chen Hour. min. mm. mm. rem, t€9•
M-2-3 & 114 79 1191 457 '222 1139 39
M-2 405605 t51 T9 1191 508 215 1191 47
M-2.40TSM 151 79 Isis 457 1543 1518 SS)
M-2 5058DS! 189 79 1181 559 1207 J _ 01 59
!ui-2-50T8oS 189 79 1461 508 1486 1461 56
M-2 65RODS 246 79 15% 559 1530 1505 7 _
83
AA-2-e0R6D5 303 79 15D5 610 1530 i5D5
79 1594 711 1032 1581 138
M-2-120R6pS 450 r ---
TAvadaote with optional hared hole Cleanout.
For 10 year modals, change suffix '6` to '10 Recarery Limitation rot vc€r:es
since element models Change suffix `D' to 'S'. GPFt Tompar Rho "F stmutrae
For
Wvtbge 60 Be 90 i0D 120 D Irlasslla 1 7rY;�
(M-2-120 not available as a single element model). MIN 10 a 7 6 5 150pW115mW Yes Yf �01711yes
'Based on 450oW/450(YW, Nor1-Simulterleo:ts operation. 2000W 14 10 9 a 7 MW /20WN €a Y" Yrs grs }yes
25M 17 13 11 10 9 25m0W 125" m Yes Yes yes AS
30DOW 21 15 14 12 10 30"1300CW ro Yes Yb yes res
35DOW 24 is 16 14 12_ 35"1350OW
400OW 28 21 18 16 '.4 4000W 14000W no Yes Yos yes +
0 4500W 31 23 21 19 15 4500Yi114SO N m is Y� '>� tm
som 34 26 23 21 17 500(YWr5000W no yes yes Yes rez
I 55W38 29 25 23 19 55W 16W
B 0Y41 31 225
21 fi00mW l600t1W na no -m IYeB ies
®� A ! D C rxGPH based on Non -Simultaneous wali'm
.-.+ g• �•-- operation. when Sknultaneous RLimtsmuteisneow 46igt1e �--
operation the GPH will 120Y 20V 24QY 2T7Y'4tia1
a approximately double.) 15001Ar 71500W ea yta
200OW 1200DW myes Yes is
25WW I Z600W Ya Yn As Yes M
3009W 13000W Yaa m Yes y'es
35M 13SOOYJ oo es rw n^
General 4000W/4000W n0 yes es es
All models EfL listed. These heaters are wired inter-10"ing 450DW 145WW na Yes Yee es
(Non -Simultaneous. Single PhaW) 240V witt1 two 45oM etemWts, jWess otherwise specitied. 500DW 15000W ro Ye5 yes Yes YE5
All water and electrical connections are 3/4" NPT (11amm), 120 galion model has 1'(2&wn) NPT. 5500W l5500W rm 3ILnos �o
All rnode€s certNiod at 300 Psi test pressure (2068 kPa) and 150 osi working pressure (1034 kPa.) 6000W 16000i'1 ra yts Yes yes
Dlmenslon8 and specffkatimm Suhilect to change withoW not)se
in aocatdaitce with OW polky of Candler" product hnpro109ment.
ow
BRADFORD PWrrE'
w T G A H 5 A 1 E Pt
Ambitx, PA
For U.S. and Canada field service. contact ywx professional irmailer or ocal Bradford Wh:te sxas r0l)=e ltalnre.
Sales m"23-2031 • Fax 215.641-1670 /Techn+cal support 80a334.33D3 P Fax 2W795.1089 * IM2rrarltY WM31.2111 • Fax 2W79&1069
hWmftftM: Tdephone 215.641-94M a Telefa11216.641-97501 wWW.braftftivlihite•oom
Rm0FAN ii►tir-CAIVAEW jmr. Sales / Tev rrcal Support 866.696.0961 / 905.238-0100 • Fax 906-238-0105 / w€xw.6radfotdwhita.com
Built to be the BestT.
C2o13, Bradford vinite Coro ration. All rights reserved.
Printed in U.S.A.
201-8-0213•A