Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
Energy Code
FORM R405-2017 FLORIDA ENERGY EFFICIENCY COOP FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: > \. �R bQ ` � � Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1442.0 sgft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1260.00 ftZ 3. Number of units, if multiple family 1 b. Frame - Wood, Adjacent c. N/A R=11.0 192.00 ft2 R= ftZ 4. Number of Bedrooms 2 d. N/A R= ftZ , 5. Is this'a worst case? Yes 10. Ceiling Types (1476.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1446.0012 6. Conditioned floor area above grade (ftZ) 1446 b. Knee Wall (Vented) R=19.0 30.00 ftZ Conditioned floor area below grade (ftZ) 0 0• R= ft Z 11. Ducts R ftZ 7. Windows(141.3 sgft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor: Sgl, U=11.04 101.25 ftZ SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ftZ 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit .34.8 SEER:15,00 c. U-Factor: N/A ftZ SHGC: 13. Heating systems kBtu/hr Efficiency . d. U-Factor: N/A ftZ a..Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 3.832 ft. Area Weighted Average SHGC: 0.284 14. Hot water systems 8. Floor Types (1445.5 sgft.) Insulation Area a. Electric 50 gallons:, CapEF: a. Slab -On -Grade Edge Insulation R=0.0 144&50 ftZ b. Conservation features 0.970 b. N/A R= ftZ None c. N/A R= ftZ 15. Credits Pstat Glass/Floor Area: 0.098 Total Proposed Modified Loads: 47.47 PASS Total Baseline Loads: 48.09 I hereby certify that the plans and specifications covered by Review of the plans and %51. . this calculation are in compliance with the Florida Energy specifications covered by this. Code. calculation indicates complianceI �. AA with the Florida Energy Code. PREPARED BY: Before construction is completed DATE: this building will be inspected for compliance p ection 553.908 I .hereby certify.that this building, as designed, is in compliance Florida Statutes. With the Florida Energy Code.{ MIA OWNER/AG%N BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 114013.2.1. Compliance requires an Air Barrier and Insulation Inspection checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelp d agep •grea Uh .0LL: 5 (R402.4.1.2): Je [) FOR j4t...v bCOE COMPLIANCE i�vclfw OOUNTy 4/21/202010:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) ComplidFOO a Page 1 of 5 -FORM R405-2017 INPUT SUMMARY CIHFCKI-1ST RFP.nRT PROJECT Title: WYNNE THE GRAND CARL Bedrooms: 2 Address Type: Street Address Building Type: User Conditioned Area: 1446 Lot # Owner Name: WYNNE BUILDING CROP Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING COPR. Rotate Angle: 180 Street: Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie . Jurisdiction: ST. LUCIE COUNTY Whole House Fan: No City, State, Zip: FT. PIERCE , Family Type: Single-family- FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating . Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter /Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1446 11568 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 BEDROOM 301 2408 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 M.BATH 56 448 No 0 1 Yes Yes Yes 4 KITCHEN 192 1536 Yes 0 1 No Yes Yes 5 BATH 45 360 No 0 1 Yes Yes Yes 6 BEDROOM 2 204 1632 No 0 1 1 Yes Yes Yes 7 ENTRY 55 440 No 0 1 Yes Yes Yes 8 LAUNDRY 42 336 No 0 1 Yes Yes Yes 9 GREAT/DINING 488 3904 No 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio BEDROOM 52 ft 0 301 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulatio M: BATH 8 ft 0 56 ft2 ____ 0 1 0 4 Slab -On -Grade Edge Insulatio KITCHEN 1 ft 0 192 ft2 ____ 0 1 0 5 Slab -On -Grade Edge Insulatio BATH 5 ft 0 45 ft2 ____ 0 1 0 6 Slab -On -Grade Edge Insulatio BEDROOM 2 32.2 ft 0 203.5 ft2 _e_ 0 1 0 7 Slab -On -Grade Edge Insulatio ENTRY 7 ft 0 55 ft2 ____ 0 1 0 4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area _ Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio LAUNDRY 6 ft 0 42 ft2 ---- 0 1 0 9.Slab-On-Grade Edge Insulatio GREAT/DINING 46 ft 0 488 ft2 ____ 0 1 0. ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch 1/ # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1524 ft2 240 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1446 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) BEDROOM 30 Blown 301 ft2 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) M. BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) KITCHEN 30 Blown 192 ft2 0.1 Wood 5 Under Attic (Vented) BATH 30 Blown 45 ft2 0.1 Wood 6 Under Attic (Vented) BEDROOM 30 Blown 204ft2 0.1 Wood 7 Under Attic (Vented) ENTRY 30 Blown 55 ft2 0.1 Wood 8 Under Attic (Vented) LAUNDRY 30 Blown 42 ft2 0.1 Wood 9 Under Attic (Vented) GREAT/DINING 30 Blown 488 ft2 0.1 Wood 10 Knee Wall (Vented) GREAT/DINING 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Cavity Width Spaceue EtEt Height In Aren Sheathing Framing Solar Below R--Vah le 1 NE=>SW Exterior Concrete Block - Int InsuBEDROOM 4.1 10 0 8 0 80.0 ft2 0 0 0.4 0 2 SW=>NE Exterior Concrete Block - Int InsLBEDROOM 4.1 28 0 8 0 224.0 ft2 0 0 0.4 0 _ 3 NW=>SE Exterior Concrete Block - Int Insu13EDR0OM 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 SW=>NE Exterior Concrete Block - Int Insul M. BATH 4.1 8 0 8 0 64.0 ft2. 0 0 0.4 0 _ 5 NE=>SW Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.4 0 _ 6 NE=>SW Exterior Concrete Block -'Int InsBIEDROOM 2 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 7 SE=>NW Exterior Concrete Block - Int InsElEbROOM 2 4.1 10 0 8 0 80.0.ft2 0 0 0.4 0 8 S=>N Exterior Concrete Block - Int InsBIEDROOM 2 4.1 4 3 8 0 34.0 ft2 0 0 0.4 0 9 SW=>NE Exterior Concrete Block - Int InsENEDROOM 2 4.1 2 0 8 0 16.0 ft2 0 0 0.4 0 10 SE=>NW Exterior Concrete Block - Int Insul ENTRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 11 SW=>NE Exterior Concrete Block - Int Insul ENTRY 4.1 1 0 8 0 8.0 ft2 0 0 0.4 0 12 SW=>NE Exterior Concrete Block - Int InsuLAUNDRY 4.1 6 0 8 0 48.0 ft2 0 0 0.4 0 _ 13 NE=>SW Exterior Concrete Block - Int InsLGREAT/DINI 4.1 26 0 8 0 208.0 ft2 0 0 0.4 0 14 NW=>SE Exterior Concrete Block - Int InsiG6REAT/DINI 4.1 20 0 8 0 160.0 ft2 0 0 . 0.4 0 4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 ,FORM R405-2017 INPUT SUMMARY ('_WF[:KI IST OPPnOT WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below In E In Area _Et 15 N=>S Garage Frame - Wood KITCHEN 11 24 8 192.0 W. 0.23 0.4 0 DOORS # Omt Door Type Space Storms U-Value Width Height Ft In Ft In Area 1 SE=>NW Insulated ENTRY None .39 3 1 6 8 20.6 ft2 WINDOWS Orientation shown is the entered orientation. _> chan ed to Worst Case.. j Wall # Ornt ID Frame Panes NFRC Overhang U-Factor, SHGC Imp Area Depth Separation IntShade Screening 1 NW=>SE 3 Metal 2 SW=>NE 4 Metal 3 SE=>NW 7 Metal 4 NE=>SW 13 Metal 5 NW=>SE14 Metal Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes Low-E Single Yes 1.04 0.29 Y 32.9 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds 1.04 0.29 Y 6.9 ft2 1 ft 0 in 1 ft 5 in None 1.04 0.29 Y 24.0 ft2 6 ft 0 in 1 ft 5 in None 1.04 0.29 Y 37.5 ft2 1 ft 0 in 1 ft 5 in None 1.11 0.27 Y 40.0 ft2 8 ft 0 in .1 ft 5 in Drapes/blinds Exterior 5 None None None Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 315 ft2 315 ft2 24 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1349.6 74.09 139.34 .1233 7 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split, Singl HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts, 1 Central'Unitl Split Singl SEER:15 34.8 kBtu/hr cfm 0.8 1 sys#1 HOT.WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric . None Garage 0.97 50 gal 60.9 gal 120 deg None 4/21/202010:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 -FORM R405-2017 INP11T S11MMARV r141=rKI1. 1CT QDDnDT SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / -- Supply--- -- Return -- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 65 ft2 Default Leakage Attic. (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans: CoolingJan Feb HeatinJan Feb Vent in Jan Mar Mar Mar Apr f Apr Apr f May May May Jun Jul f Jun f Jul Auge 4 Aug Sep Oct f Oct Nov Nov Dec f X� Dec .Feb [X] [ [ Jun [ Jul [ Au Se [X] Oct Nov [ ]Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 .78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 -PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS, Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq:ft. ft2 ft 0.3 MASTER BATH Default(8lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8 Ibs/sq.ft, ft2 ft 0.3 LAUDRY Default(8 lbs/sq.ft. ft2. ft 0.3 BEDROOM 2 Default(8.lbs/sq.ft. ft2 ft 0:3 DINING/GREAT R Default(8lbs/sq.ft. ft2 ft, 0.3 KITCHEN . Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default(8 Ibs/s .ft. ft2 ft 0.3 BEDROOM-8 4/21/2020 10:27 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software . Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE GRAND CARLTON IMPACT Builder Name: WYNNE BUILDING COPR. Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: te Owner: WYNNE BUILDING CROP Jurisdiction: ST. LUCIE COUNTY w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealin material. g Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall .be ,aligned with The insulation in an dropped ceiling/soffit y g /soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned gned with the air barrier. air Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed.in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and . and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that.on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac as.. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to. ft around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed: in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not. be used to fill voids a. M aeanwn, mspecuun ur iug waus snau oe in accordance wnn ine provisions or IGG-400. 4/21/2020 10:32 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* =. 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 .2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 _ 4. Number of bedrooms 4. 2 13. Cooling system: Capacity 34.8 a) Split system. SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package.. SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6.. 1446 d) Room unit/PTAC EER e) Other 7.,Windows, type and area a) U-factor:(weighted average) 7a. 1.060 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.284 14. Heating system: Capacity 34.8 c) Area 7c. 141:3 a) Split system heat pump HSPF . 8.5. b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas . AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation•R-value) 10131. 11.0 2. Masonry (Insulation R-value) 1082. 1.6. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No . e) Multizone heating credit 0 Programmable thermostat Yes ''Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving.features which.will be installed (or exceeded).in this home before final inspection. Otherwise, a new EPL display card will.be completed based on installed code compliant'4eatures. Builder Signature: Date: Address of New Home:S.A-A � City/FL Zip: FT. PIERCE: FL 4/21/2020 10:32:17 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 Project Summary o Wlright`# : Entire House By. QUICK CALLS, INC. 317 ST.. LUCIE LN., FL PIERCE, FL 34946 Phom 772-466-6799 Fax 772-466.,6796 Email: QUICKCALCS ,AOL.COM For: THE GRAND:CARLTONIMPACT _ WYNNE DEVELOPMENT, FT. PIERCE, FL Notes: Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside.db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 grAb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17848 Btuh Structure 17520 Btuh Ducts 5654 Btuh Ducts 8536 Btuh Central vent (O cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none). (none) Humidification 0 . Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 23503 Btuh Use manufacturer's data n Rate/swin multipplier 0.95 Infiltration EquipmenisensCe load 24753 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 3203 Btuh Duds 2318 Btuh Central. vent (O cfm) 0 Btuh Heatingg. Cool' (none) . Area (fF) 144ti 1Z% Equipment latent load 5521 Btuh Volume (ft3) 12511 12511 Air changes/hour 0.45 0.23 Equipment Total Load (Sen+Lat) 30274 Btuh Equiv AVF (clim) 94 48 Req. total capacity at 0.70 SHR 2.9 ton Heating Equipment Summary Cooling Equipment Summary Make Carrier Make Carrier Trade CARRIERAIR CONDITIONING Trade CARRIERAIR CONDITIONING Model 25HBC536KO30 Cond 25HBC536KO30 AHRI ref 7914585 Coil FX4DN(B'F)037 AHRI ref 7914585 Efficiency 8.5 HSPF Efficiency 12.0 EER,15 SEER Heating Input Sensible cooling 24360 Btuh Heating output 34600 Btuh @ 470F Latent cooling 10440 Btuh Temperature rise 27 OF Total cooling 34800 Btuh Actual airflow 1160 cfm Actual airflow 1160 cfm Airflowfador 0.049 cfm/Btuh Airflowfactor 0.045 cfm/Btuh Static pressure 0.50 in H2O Static pressure 0.50 . in H2O Space thermostat Load sensible heat ratio 0:83 Capacity balance point = 32 OF Backup: Input = 7 kW, Output = 23009 Btuh,100 AFUE Calculations approved byACCAto meet all requirements of Manual J 8th Ed. j. wr�gi•� Rit#� 2020-Jarr081620:47 - ,��,.w.�A.���,^�^ b,.q. .a Right Sdte@ Urivers.al 20l, 9 l9.0.07 RSU08101 �.:E.� � Page 1 IghtsoffWAMTHEGRAND CARLTON-1446-IMPACT.np Calc=MJ8 FrontDoorfaces: N - wl ig>htsaw RighWO Worksheet Job: Entire House Date: QUICK CALLS, INC. By 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM 1 Room name Entire House BEDROOM 2 End wall 1562 ft 49.0 It 3 Room height 8.7 it d 8.0 ft heaftol 4 5 Room dimensions Room area 1445.5 IF 1.0. x 297.0 ft 297.0 ftz Ty Construction U-value Or HTM Area (iF) Load Area (Itz) Load number (Bluhl!F--°F) (Bluh/W) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 y✓ 13A-4ocs 0.143 • n 4.00 2.55 663 465 1862 1184 . 72 72 288 183. -G AA5-2om 0.770 n 21.56 '19.31 '38 0 815 730 ' 0 0 .0 0 13AAocs 0.143 a 4.00 2.55 128 83 333 212 0 0 0 0 11 1A-clom 11DO 1270 0.390 a a 35.56 10.92 8729 -11.31 24 21 2 21 848 229 2082 238 0 0 0 0 0 0 0 0 D W . -13A-4ocs 0.143 se . 4.00 2.55' 34 34 136. 86 0 0 -.0, 0 13A-4ocs 0.143 s 4.00 2.55 360 353 1414 899 216 216 865 550 G 1Aclom 1270 s 35.56 34.77 7 7 247 241 0 0 0 0 13A-0as 0.143 vv 4.09 2.55 310 237 949 603 104 72 288 183 G IA-clom 1270 - w 35.56 '5521 32 2 1140 1770 32 2 1140 1770 '4A5-2om 0.770 w 21.56 19.31 41. 41 880 788 0 0 0 0 P 12C-0snr 0.091 2.55 128 192 192 489 246 0 0 0 0 C 16A-30md 0.032 - 0.90 2.32 1446 1446 1295 3354 297 297 266 689 F 22A tol 0.989 27.69 0.00 1446 156 4325 0 297 49 1357 0 6 c) AED excursion 918 627 Envelope loss/gain 14961 13349 4204 4003 12 a) Infiltration 2887 791 848 232 b) Room ventilation 0 0 0 0 13 Internal gains'. Occupants@ 230 6 1380 3 690 Appiianoes/other 2000 0 Subtotal (lines 6 to 13) 17848 17520 5053 4925 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 17848 17520 5053 4925 15 Dud loads 32% 49% 5654 8536 32% 49% 1601 2400 Total room load 23503 26056 6653 7325 Air required (dm) 1 1160 1160 1 328 326 Calculations awroved WACCA to meet all requirements of Manual J 8th Ed. A- enrrj0ft rscdT- 2020-Jan-081620:47 Right -Suite® Universal 20191.9.0.07 RSU08101 Page 1 ighIsoftHVACWHEGRAND CARLTON-1446-IMPACT.np Calc=MJB Front Door faces: N 'F wdghtw Right-J® Worksheet Entire House, QUICK CALLS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772-466.6799 Fax 772-466-6796 Email: QUICKCALCS@40L.COM Job: Date: By 1 Room name WIC . Krl-CHEN 2 Eposedwall 0 It 0 It 3 Room height 8.0 It heatlwol 8.0 ft heaNwol 4 Room dimensions 6.0 x 9.0 It ID x 172.0 It 5 Room area 54.0 1F 172.0 iF Ty Construction U-value Or HTM Area (W) Load Area (its Load number ' (BtuhHVF) (Bluh/fF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yJ G 1*4ocs 0143...-n 4;00 ;.. 255 0 0 0 0 0 ..- .0 .0 0 4A52dm ' 13A-4ocs 0.770 0.143 n a 21'.56 4.00 19.31 2.55 0 0 �,. 0 0 .0 0 0 0 0 0 0 0 m 0 0: 0 0 V�l�G 11 1Aclom 11DO 1270 0.390 a a 35.56 10.92 8729 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 W. t13AAocs 13A-4ocs 1A-clom 0.1.43 0.143 1270 se s s 4.00 4.00 35.56 2.55 ' 2.55 34.77 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 . 0 0 0 .0 0 0 -G 13A2loc a 0143 . w 4.00 2.55 0 0 0 0, 0 0 0 0 G 1A Glom 1270 w 35.56. 55:21 0 0 0 0 0 0 0 0 ;'4A5-2om . 0.770 w 21.56 19;31 0, 0 0 0 0 0 0 0 P 12C-Osw 0.091 2.55 128 0 0 0 0 64 64 163 82 C :16A-30md 0.032 - 0.90 `2.32 - . 54: 54 48 125 172 -172 154 399 F 22A tpl 0.989 - 27.69 0.00 54 0 0 0 172 0 . 0 0 6 c)AEDexcursion -9 -170 Envelope lossigain 48 117 317 311 12 a) Infiltration 0 0 0 0 b) Roomventilation 0 0 0 0 13 Internal gains: Occupants.@ 230 0 0 0 0 Appliances/other 0 2000 Subtotal (lines 6 to 13) 48 117 317 2311 Less extemal load 0 0 0 0 Lesstransfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 48 117 317 2311 15 Ductloads 32% 49% 15 57 326/. 49% 100 1126 Total room 'load Air required (dm) 64 3 174 8 418 21 3437 153 Calculations approved WACCAto meet all requirements of Manual J 8th'Ed. Nglsfis°ot1't^'. RigitSute®Uriversal2019.19.0.07RSU08101 2020-Janr081Page42 AM ightsoftWAC\THE GRAND CARLTON-1446-IMPACT.np Caic=WB Front boor faces: N - m ightsoft° Right-M Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@AOL.COM Job: Date: By. 1 Room name BATH BEDROOM2 2 EVosed wall 5.0 it 342 ft 3 Room height 8.0 ft heat/cool 8.0 ft heat(000l 4 5 Room dimensions Room area 9D x 5D ft 45.0 ftz ID x 203.5 ft 203.5 flz Ty Construction U-value Or . HTM Area (ftz) Load Area (ftz) Load number (Btuh/ftz--F) (Btuh/iF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 yyJJ �G 13AAocs .-4A5-20m 13A-0as 0.143 0.770 0.143. n n a 4.00 21:56 4.00 2.55 " 19.31 2.55 40 0 0 40 0 0 160 . ' 0 0 102 .0 0 128 .0 80 128 0 56 513 :0 225 326 0 143 V�1 �L-_-G 11 1Aclom 11DO 1270 0.390 a a 3556 10.92 8729 11.31 0 0 0 0 0 0 0 0 24 0 2 0 848 0 2082 0 D W . Y--G •13A-0as 13A4acs 1Aclom 0.143 0.143 1270 'se s s 14.00 4.00 35.56 2.55 2.55 34.77 0 0 0 0 0 0 0 0 0 0 0 0 34 32 0 ' 34 32 0 136 128 0 86 81 0 G 13A-46cs IA-clom 0.143. 1270 w w 4.00 35.56 2.55 5521 0 0 0 0' 0 0 0 0 0 0 0 0 0 0 0 0 .4A5-2om 12C-Osw 0.770 0.091 ; w 21.56 2.65 1931 128 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 P C 16A-30md. 0.032 0.90 2.32 45 45 40- 104 204 204 182 472 F 22A-ti)l 0.989 - 27.69 0.00 45 5 138 0 204 34 946 0 6 c) AED excursion -16 -85 Envelope low/gain 339 190 2978 3106 12 a) Infiltration 87 24 593 162 b) Room ventilation 0 0 0 0 13 Internal gains. Occupants@ 230 0 0 1 230 Applianoesrother 0 0 Subtotal (lines 6 to 13) 425 214 3571. 3498 Lessextemalload 0 0 0 0 Less transfer 0 0 0. 0 Redistribution 0 0 0 0 14 Subtotal 425 214 3571 3498 15 Ductloads 32% 49% 135 104 32% 49% 1131 1704 Total room load 560 318 4702 5203 Air required (dm) 28 14 232 232 Calculations approved byACCAto meet all requirements of Manual J 8th Ed. A -�}+- wr>igl�tsryoYt- 2020-Jan-08 9620:47 AM Right-SUte®Ur1versal 201919.0.07 RSU08101 Page 3 ightsoftwAC\THEGRAND CARLTON-1446-IMPACT.np Calc=MJ8 Front Door faces: N vm4huMt Right-JO Worksheet Entire House QUICK CALLS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone:772-466-6799 Fax 772-466-6796 Email: QUICKCALCS@,AOL.COM Job: Data: ft- 1 Room name LAUNDRY " GREAT/DINING 2 Exposed wall 6.0 It 47.0 it 3 Room height 8.0 ft heat/cool 9.8 it heat/000l 4, 5 Room dimensions Room area 7.0 x 6.0 it 42D ft2 1.0 x 526.0 it 526.0 ftz Ty Construction U-value IOr HTM Area, (W) Load Area (ftz) Load number (13II&F--T)• (Btuhd2) or perimeter (ft), (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 93AAocs 0143 : 7n .-4.00 2.55 0 0 0 0 . 255 217 866 552: [4A5.2om 13AAocs 0.770 0.143 n a . 21:56; 4.00 19,31' 2.55 0 0 :. 0 0 0 0 0 0 38: 0 :: 0 0 815 0, 730 0 11 1A-c1om 11D0 1270 0.390 a a 35.56 10.92 8729 11.31 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 D W, yJ �G 13AAocs 13A4o s 1A-clom 0.143 0.143 1270 se s s 4.00 4.00 35.56 2.55 2.55 34.77 0 48 0 0 48 0 0 192 0 0 122 0 0 0 0 0 0 0 0 0 0 0 0 0 G "13A flocs %dom- 0.143 1270 w w 4.00 35.66 2.55 6521 0 "0 0 0 0 -0 0 0 206 0 . 165 0 661 0 420 0 4A526m . 12C-0sw 0.770 0.091 w 21.56 2.55 19.31 128 0 56 " 0 56 0 143 0 72 - 41 0 41 0 880 0 788 0 P C ." ., 16A30md 0.032 , 0.90 ` : °2.32 ^42 42 38 97 526 " 526 471 1220 F 22/k>pl 0.989 27.69 0.00. 42 6 166 0 526 47 1302 0 6 c) AED excursion -22 668 Envelope low/gain 539 270 4997 4379 12 a) Infiltration 104 28 997 273 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 2 460 Applianceslother 1 0 0 Subtotal (lines 6 to 13) 643 298 5994 5112 Less extemalload 0 0 0 0 Less transrer 0 0 0 0. Redistribution 0 0 0 0 14 Subtotal. 643 298 5994 5112 15 Dud loads 1 32% 49% 204 145 32% 49%1 1899 2490 Total room'load 1 846 443 1 1 7892 7602 Air required (dm) 42 ' 20 390 338 Calculations approved WACCAto meet all requirements of Manual 8th Ed. . r -f}i- wwr7gnesc t - 2020-Jan-081620:47 ACCk w° Right SuteO Uriversal 201919.0.07 RSU08101 Page 4 igttsoftHVAC\THE GRAND CARLTON-1446-IMPACT.4 Calc=MJB Front Door faces:�N - Wfightsofttl Right-M Wolrksheet Job:, Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: QUICKCALCS@, ,OL.COM 1 Room name FOYER M BATH. 2 Exposed wall 7.0 It 8.0 It 3 Room height 8.0 it heaV000l 8.0 It heaVcool 4. 5 Room dimensions Room area. 1.0 x 50.0 it 50.0 fe 7.0 x 8.0 It 56.0 fts Ty Construction U-value Or HTM Area (T) Load Area (ft') Load number (BtirhllP--°F) (Bluh/fF) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 V/ 13A-4ocs 0.143 n .4.00 2.65 .8 8 32 20 0 0 0 0. L--G :4A5-2om 13A4ocs 0.770 0.143 . n a . 21'.56. 4.00 .. 19.31 2.55 0- 48 0 27 0 108 .0 69 0'. 0 0 0 .0 0 0 0 11 1Aclom 11DO 1270 0.390 a a 35.56 10.92 8729 11.31 0 21 0 21 0 229 0 238 0 0 0 0 0 0 0 0 D W. Vu �-G 13A4ocs 13A-4ocs IA-clom 13A46cs 1A-clom 0.143 0.143 1270 .0.143. 1270 se s s w w 4.00 4.00 35.56 4.00 35.56 2.55 2.55 34.77 2.65 55.21 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 64 7 0 0 0 57 7 0 0 0 228 247 0. 0 0 145 241 0 0 G .4AS-2om 12C-Osw 0.770 0.091 w 21.56. 2.55 19.31 1.28 0: 72 0 72 0 183 0 92 0 0 0 0 0 0 0 0 P C . 16A30md 0.032 0.90 2.32 50 50 45 116 56 56 50 .130 F 22A t3l 0.989 27.69 0.00 50 7 194 0 56 8 222 0 6 c) AFED excursion -39 38 Envelope lose/gain 792 496 747 478 12 a) Infiltration 121 33 138 38 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants@ 230 0 0 0 0 Applianoes/other 0 0 Subtotal (lines 6 to 13) 1913 529 885 516 Less extemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 913 529 885 516 15 Duct loads 32% 49% 289 258 32% 49% 280 251 Total room load 1202 787 1166 768 Air required (clm) 1 59 35 58 34 Calculations aDbroved bvACCAto meet all reouirements of Manual J 8th Ed. -Fw vvrigfatsaf••t- 2020-Jan-081620.47 MghYStiteO Uriversal 201919.0.07 RSU08101 Page 5 AM tgltsoftWAC1THEGRAND CARLTON-1446-IMPACT.nQ Calc=MJ8 FrontDoorfaces: N . Wrightsoft. Duct System Summary oob- Entire House Bj- QUICK CALCS, INC. 317 ST. LUCIE LN., Fr.. PIERCE, FL 34946.Phone: 772-46.6-6799 Fax 772-466-6796 Ernall: QUICKCALCS@AOL.COM e-roject intormation For: THE GRAND CARLTON IMPACT WYNNE DEVELOPMENT, FT. PIERCE, FL Extemal static pressure Pressure losses Available static pressure Supply /.retum available pressure Lowestfiction rate Actual airflow Total effective length (TEL) Heating 0.'50 in H2O 0 in H2O 0.50 . in H2O 0.250 / 0.250, i d H2O 0.285 in/100ft 1160 cfm 176 ft Supply Branch Detail Table Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.285 in/100ft 1160 cfm Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Mat Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH h 560 28 14 0.364 4.0 Ox 0 MFx 22.4 115.0 . st1 8EDROOM2 h 4702 232 232 0.360 7.0 Ox0 VIFx 23.9 115.0 st1 BEDROOM -A h 3327 164 163. 0.300 6.0 Ox 0 VIFx 31.8 135.0 st2 BEDROOM h 3327 164 163 0.285 6.0 Ox 0 MFx 40.6 135.0 st2 FOYER h 1202 59 35 0.505 4.0 Ox0 VIFx 4.0 95.0 GREAT/DINING h 3946 195 169 0.300 7.0 Ox 0 MFx 31.8 135.0 st2 GREAT/DINING-A h 3946 195 169 0.300 7.0 Ox 0 VIFx 31.8 135.0 st2 KrrCHEN c 3437 21 153 0.379 6.0 Ox 0 MFx 17.0 115.0 st1 LAUNDRY h 846 42 20 0.361 4.0 OxO VIFx 23.3 115.0 st1 M. BATH -A h 768 58 34 0 0 Ox 0 MFx 0 0 wIc C 174 3 8 0.309 4.0 Ox 0 VIFx 27.0 135.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st2 PeakAVF 721 672 0.285 918 12.0 0 x 0 VinIFIX st1 st1 PeakAVF 1043 1091 0.285 1020 14.0 0 x 0 VinlFlx wright s dfL- 2020-Jarr081620.48 <RlghtSL te® Uriversal 201919.0.07 RSU08.101 Page 1 ...IgFLsoftWAC1THEGRAND CARLTON-1446-IMPACT.np Calc=MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist , Opening (in) Duct Mat. Trunk rb1 Ox0 1160 1160 0 0 0 0 Ox 0 VIFx - wrigh'tsoft- 2020-Jan•0816:20:48 AC.� nw,a•[e•mm�.«•mm ym•vmr Right-SUteO Uriversal 201919.0.07 RSU08101. Page 2 ightsoftHVACWHEGRAND CARLTON-1446-IMPACT.rnp Calc=W8 Front Door faces: N