HomeMy WebLinkAboutTrussi A=LIFE SAFETY WARNING This symbol identifies Life Safety Warnings that should be read given special attention by all persons installing trusses. 5PAGING NOTE ALL TRUSSES ARE TO BE SET I AT 2'-0: ON GENTER EXCEPT AS NOTED ST MULTIPLE PLY TRUSSES MUST BE ASTENED TOGETHER PER ENGINEERING BEFORE SETTING. REFER TO ENGINEERING DRAWING TO DETERMINE A IF MULTIPLE PLY. A n' DON'T LIFT TRUSSES WITH SPANS LONGER THAN 30' BY THE PEAK. CONSULT BCSI 30' Span or less J 30' to 60' Span 60 degrees Sprea er Bar or less 1 /2 _-� a9—APProx 2/3 to 9 spa AIJprOX: Line 1/2of Span 7o Line REFER TO BCSI REFER TO BCSI Truss must be set this way if crane used Truss must be set this way if crone used. Truss Is an example, your truss may not march. This is an example, truss may not match. Insist crane operotorsets truss this way' Insist crone, operator. sets truss this way. a F9 All load bearing walls, headers, beams & lintels must be in place at indicated height before trusses A are installed. A AI R HAIV ICI—F=f=R NOTE UNLESS NOTED ELSEWHERE ON THIS LAYOUT, THESE TRUSSES ARE NOT DESIGNED FOR AIR HANDLERS IN THE ROOF OR FOR ANY OTHER A/C REQUIREMENTS. THIS MAY BE IN CONFLICT WITH BUILDING CODE AND A/C DESIGN REQUIREMENTS. CONSULT WITH BUILDING DEPARTMENT AND A/C CONTRACTOR. -: U REPRESENTS A ttANGER For Truss to Truss Connections see hanger/connector schedule in engineering package. Carrying Girder Nails must be as shown. Guide tabs o Dome angle nails. SEAT PLATES BY CHAMBERS INDICATES LOAD BEARING WALL REQUIRED BY TRUSSES SUPPLIED BY BUILDER AT A HEIGHT OF 8'-1" ABOVE FINISHED FLOOR 12 4.00 to upset=1/4" heel=315/16" PLUMB CUT END 2 x 4 Top Chard WALL HEIGHT 8'-1" TYPICAL END DETAIL 12 , 4.00 f - r 1, 2 2.00 8�— upset=l/4" heel=315/16" PLUMB CUT END 2 x 4 Top Chord WALL HEIGHT 8'-1" END DETAIL: A Tha.Arfiht.!+w!`e wr ^0011604807ppraaeNtetiaa'e shop drowifi g approval Is NOT a "deubie sheeka of the aonl reetgr, The centraatar Shall refnaln respanaihla for checking Cold InaeauronfaRta Ann other conestruothim arlterlor Afohltcct"a ® ARRANGE ITH CRANE OPERAT IN ADVANCE FOR A SPREADER BAR OF 171- 23' I L GTH °° °"a"�erffiganar°""°®fahapa, review of truss strapping, and loading on structure from gravity and uplift loads and ® Do not standon trusses until they are braced r%er BCSI & properly nailed to straps & hangers =n r atlons __. Approved By. 'AA' 14' J2 5 GRB J2 J4 J4 J6 J6 A9 AS I I A7 i A6 I A5 I I A5 I 1 t I A5 I AS I I 1. A5 I A5 2/1 INT. 13'-7 1 /2" \I I A5 .... ... A5 A All _ A F- �LL o UU A <I F- loLu a A z ¢ to _ ao o A m F z W �i2 A A A GRA J6 J6 bo _ 0 J4 J4 J2 J2 +1b N V 0 ea o7 m as m f0 � t0 ® m aJ O N _ 5' GARAGE LEFT 20' y N I i eI J " 9 -6 3 -4 GARAGE RIGI-T Date. I.:.,. P.A.. .. FABRICATION AG' EMEND' TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED The legal description of the property where the trusses will be Installed is: - The undersigned acknowledges and agrees: t: Trusses will be made In strict accordance with this truss placement diagram layout, which is the sole authority for detennlning.successful fabrication of the trusses. 2. All dimensions In this layout have been verified by the undersigned. _ .3, Unless written notice is provided by cenlged mall to Chambers Truss within ton (10) days of delivery the undersigned agrees that no backoharges will be allowed, In the event such written notice Is furnished Chambers Truss shall have three (3) bu{ilness days In which to begin repalre required, or to substitute othet. trusses, at Chambers option. 4. The undersigned acknowledges recelpt of "BCSI 1.03" summary sheet by'rPi & WTCA. 6. Delivery is to job site. It Is the buyefs'nesponslblllty to make the job site suitable for delivery. Chambers Truss has the sole authority to determine the suitability of the job site ok a portion of the job site for delivery, Chambers Truss wil be responsible for dump delivery only. The buyer Is responsible for additional delivery expenses If Chambers Truss has to redellver because job site Is not prepared for delivery or buyer Is not prepared for delivery of trusses. - Buyer le responsible to Chambers Trues for touring costs duo to stte cendltlone. 8. Price as shown In paragraph 7 below Is subject to change If any changes are. made In t111s.layouL A S50 per hour fee for revisions may be charged by Chambers Tntss. ' • • 7: 7hl6le a PURCHASE ORDER to Chambers, was of the sum agreed to, or If nqq, agreement a reasonable price. Invoice vAll be made on delivery and paid vAthln terms of net" on delivery. Invoice may, be made at scheduled date of delivery It buyer cannot accept- delivery of fabricated biases. The undersigned agrees to pay Chambers.Trues masonabld ettomey'e tea for eollectlbns In event of payment not timely made. 1.12 %per month eervjca ' charga will be added for all sums not paid within terms. 8. Signature or Initials anywhere on this sheet constitutes agreement to all terms herein. 9. In wnalderation of Chambers Truss extending credit for this material the undersigned - undondldonelly guarantees payment when due pf any end ell Indebtedness awed to . Chambers Trues by any entity recelNng materiel an the undersigned agrees to pay such Indebtedness Including attorneys fees, If default In payment for material be made by the recipient. 1.- 10. In the event of any litigation concerning this agreement, the Items furnished hereunder or payments referred to herein, the, parties agree that the sole venue for any such action will be Saint 60de County, Florlds. 11. Design responsibilities are per "National Standard And Rocammended Guidelines On Responsibilities For Construction Using Metal Plate Connected Wood Trusses ANSI(rPIMlTCA4-2002"-- DATED FOF� TITLE _ A. spreader bar maybe tegtfued per"BM 1-03" to prevent Injury & datnago. Multiple ply trusses must be fastened togithar per engineering before they are set, failure to do so can resulttn roof collapse. Temporary and permanent bracing are required and can save life and property and Is the responsibility of the truss erector. Study the contents of the Information packet Included on delivery before setting trusses. Trusses must besetand traced perdeslgn to prevent inli & damage. Trusses must be sat plumb and square . Do not set bunks or stack of plywood, roofing material or any other concentrated loads on trusses, this can cause collapse. DO NOT SET TRUSSES USING THIS LAYOUT ` USE LAYOUT DELIVERED WITH TRUSSES TO SET TRUSSES I CHAMBERS TRUSS INC I 3105 Uleander Avenue Fort Piercer Florida 34982-6423 800.551-5932 Fort Pierce 772-465-2112 Fax 772.46S-8711 Vero Beach 772-569-2012 Stuart 772-2863302 92.0/93.2 MITEK 4.2 DESIGN CRITERIA County SAINT LUCIE Building Department SAINT LUCIE COUNTY Wind Design Criteria ASCE 7-2010 Wind Design Method MWFRS/C-C hybrid Wind ASCE 7-10 j Roofing Material Shingle or Shake `r Is N Loading in PSF Roof R.D.L. H ` c Top Chord Live 20 % .o Top Chord Dead 7 4.2 o , c , Bottom Chord Live 10 Non -Concurrent Bottom Chord Dead 10 3 c<,I TOTAL Load 37 7.2 0 Duration Factor 1.25 to Wind Speed 165mph H �+ Top Chord C.B. Sheeting by builder. Bottom Chord C.B. Sheeting by builder. Highest Mean Height 14'-0" Building Type ENCLOSED Building Category REVIiffiMAE sFiQ% Exposure CategorCODEITZOMPLIANCE Barrier Island ccT� Lft1E COUNTY Conforms to FBC ZffTT^►��^+( R.D.L.=Restrainin Dead Load C.ALIPO lU UOUS Bracing Verify DESIGN CRITERIA shown above with the building department and your engineer. ry Design Criteria is the responsibility of the Building Designer and/or En ineer of Record. Chambers Truss Inc. Drawing Name: M11323 LL! Scale: 1 /4 =1' 72 total trusses, 13 different trusses. FWM MI 4: SAE ACAD: SAE Reviewed By: P n Date: 04/24/12 Revised: 02/21/18 `,/ J FOR Revised: 3/05/2020 Q WYNNE BUILDING CORP. - DESCRIPTION: CARLTON� PAGE 1 of 1 CUSTOMER INITIALS EACH PAGE 13 TRU:,S DRAWINGS ARE AVACHED To LAYOUT M 11323 MiTeko s\ RE: M11323 MiTek USA, Inc. M11323 6904 Parke East Blvd. Tampa, FL 33610-4115 Site Information: Customer: WYNNNE DEVELOPEMENT CORP Project Name: M11323 Lot/Block: Model: CARLTON Address: N/A Subdivision: City: PORT ST LUCIE State: FL General Truss Engineering Criteria & Design Loads (Individual Truss Design Drawings Show Special Loading Conditions): Design Code: FBC2017ITP12014 Design Program: MiTek 20/20 8.1 Wind Code: ASCE 7-10 Wind Speed: 165 mph Roof Load: 37.0 psf Floor Load: N/A psf This package includes 13 individual, dated Truss Design Drawings and 0 Additional Drawings. With my seal affixed to this sheet, I hereby certify that I am the Truss Design Engineer and this index sheet conforms to 61 G15-31.003, section 5 of the Florida Board of Professional Engineers Rules. No. Seal# Truss Name Date 1 T19884596 A 12/17/2020 2 T19884597 A5 12/17/2020 3 T19884598 A6 12/17/2020 4 T19884599 A7 12/17/2020 F T LfaC 0 Ply 5 T19884600 A8 12/17/2020 6 T19884601 A9 12/17/2020 7 T19884602 GRA 12/17/2020 8 T19884603 GRB 12/17/2020 9 T19884604 J2 12/17/2020 10 T19884605 J4 12/17/2020 REVIEWED FUH 11 T19884606 J6 12 T19884607 J8 12/17/2020 12/17/2020 CODE COMPLIANCE 13 T19884608 KJ8 12/17/2020 ST. LUCIE COUNTY BOCC This item has been electronically signed and sealed by Velez, Joaquin using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies The truss drawing(s) referenced above have been prepared by MiTek USA, Inc under my direct supervision based on the parameters provided by Chambers Truss. ���� (RUIN n Engineers Name: Velez, Joaquin ��% ON Truss Design 9 9 Q . � .•''GENE' � � My license renewal date for the state of Florida is February 28, 2021. ��� �-� SF �'•. '�� Florida COA: 6634 No 68182 IMPORTANT NOTE: The seal on these truss component designs is a certification that the engineer named is licensed in the jurisdiction(s) identified and that the designs comply with ANSI/TPI 1. These designs are based upon parameters shown (e.g., loads, supports, dimensions, shapes and design codes), which were given to MiTek. Any project specific information included is for MiTek customers file reference purpose only, and was not taken into account in the preparation of these designs. MiTek has not independently verified the applicability of the design parameters or the designs for any particular building. Before use, the building designer should verify applicability of design parameters and properly incorporate these designs into the overall building design per ANSI/TPI 1, Chapter 2. O:. STATE OF N A II111 Joaquin Velez PE No.68182 MITek USA, Inc. FL Cert 66M 6904 Parke East Blvd. Tampa FL 33610 December 17, 2020 1 of 1 Velez, Joaquin Job Truss Truss Type Qty Ply M11323 T19BB4596 M11323 A COMMON 9 1 Job Reference (optional) t,namoers truss, Inc., Fort tierce, t-L 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:27 2020 Page 1 ID:a3B4PavKnnZweXyJckSFBgyuFUN-bAjL909k_l Hpv5SDpc_pEKrtnVLQuvtwTtLrJ WzUUjw rl-0 q 6-7-13 12-4-13 17-0-0 21-7-3 27.4-3 34-0-0 35-0-0 1-0-0 6-7-13 5-9-0 4-7-3 4-7-3 5-9-0 6-7-13 o- N1 d 3x6 = 4.00 12 4x5 = 27 I -- 15 -" "' 14 '- 12 2x3 II . 4x6 = 3x8 = 124-13 3x8 = 4x6 = 2x3 ll 34-M Scale = 1:57.8 3x6 = 1 N I6 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017/TPI2014 CSI. TIC 0.39 BC 0.58 WB 0.65 Matrix -MS DEFL. in (loc) Vdefl Ud Vert(LL) 0.32 14-15 >999 360 Vert(CT) -0.61 14-15 >670 240 Horz(CT) 0.12 10 n/a n/a PLATES GRIP MT20 2441190 Weight: 163 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 3-7-12 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-11-7 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-832(LC 10), 10=-832(LC 10) Max Grav 2=1362(LC 1), 10=1362(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-341912395, 3-5=-2771/2031, 5-6=2770/2152, 6-7=2770/2152, 7-9=2771/2031, 9-10=-3419/2395 BOT CHORD 2-17=-2132/3213,15-17=-2132/3213,14-15=-1269/2000,12-14=-2132/3213, 10-12=-213213213 WEBS 6-14=-635/983, 7-14=-313/362, 9-14=689/499, 6-15=-635/983, 5-15=-313/362, 3-15=-689/499 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; 8=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2) 13-7-3 to 20-4-13, Interior(1) 20-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide This item has been will fit between the bottom chord and any other members, with BCDL = 10.Opsf. electronically signed and 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) sealed by Velez, Joaquin, PE 2=832,10=832. using a Digital Signature. 6 Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 50 lb down and 47 lb up at 15-0-0, and 50 lb down and 47 lb up at 19-0-0 on top chord. The design/selection of such connection device(s) is the responsibility Printed copies of this of others. document are not considered 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). signed and Sealed and the signature must be verified LOAD CASE(S) Standard 1) Dead +Roof Live (balanced): Lumber Increase=1Plate Increase=1.25 on any electronic copies..25, Uniform Loads (plf) Joaquin Velez PE No.68182 Joa 9 Vert: 1-6=-54, 6-11=-54, 18-21=-20 MiTek USA, Inc. FL Cert 6834 Concentrated Loads (lb) 8904 Parke East Blvd. Tampa FL 33610 Vert: 26=-50(F) 27=-50(F) Date: April 3,2020 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and Is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall R �� �• building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iViiTek� is always required for stability and to prevent collapse with possible personal Injury and properly damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSUTP11 qualify Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway. Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884597 M11323 AS SPECIAL � 9 1 Job Reference (optional) unamoers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:28 2020 Page 1 ID:2GIScwwyY5hnGhXVARzUkuyuFUM-3MHjMkAMIKQgXE1 PNJV2mXOxRucedNo4iX50ryzU Ujv 11-0 0 7-8-5 10-64 17-0-0 204 8 264-0 34-M 35-0-Q Y-0-O 7-8-5 2-9-15 ' 6-5-12 34-8 5-11-8 748-0 6 3x12 = 2.00 F12 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017rTP12014 LUMBER - TOP CHORD 2x4 SP M 30 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 6-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 10=0-8-0 Max Horz 2=-179(LC 8) Max Uplift 2=-803(LC 10), 10=803(LC 10) Max Grav 2=1312(LC 1), 10=1312(LC 1) 5x8 MT18HS II 4.00 12 Scale = 1:59.8 13 12 5x12 = 2x3 II 3x6 = 264-0 CSI. DEFL. in (loc) Vdefl L/d PLATES GRIP TC 0.85 Vert(LL) 0.76 14 >539 360 MT20 244/190 BC 0.90 Vert(CT) -1.18 13-14 >344 240 MT18HS 244/190 WB 0.60 Horz(CT) 0.36 10 n/a n/a Matrix -MS Weight: 155 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 1-7-8 oc purlins. BOT CHORD Rigid ceiling directly applied or 3-9-12 oc bracing. WEBS 1 Row at midpt 6-14 FORCES. (lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5529/3776, 3-5=-516413538, 5-6=5209/3667, 6-7=2424/1902, 7-9=-2462/1813, 9-1 0=-3195/221 0 BOT CHORD 2-14=-3466/5266, 13-14=-1305/2115, 12-13=-1948/2995, 10-12=-1948/2995 WEBS 3-14=-355/314, 5-14=-293/354, 6-14=2175/3326, 6-13=279/534, 7-13=-237/277, 9-13=-786/560, 9-12=0/269 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 13-7-3, Exterior(2) 13-7-3 to 20-6-4, Interior(1) 20-6-4 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) All plates are MT20 plates unless otherwise indicated. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 6) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=803, 10=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ®WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE 10II-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall �• building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing l Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the p ATek• fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11rPl1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20501 Tampa, FL 36610 Job Truss Type Qty Ply M11323 ]SPECIAL T19884598 M11323 A6 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:29 2020 Page 1 I D:2 G IS cwwyY5hnGhXVARzU kuyuFU M-YYr6a4 B_WeYX90cbw00HJlx7ilyPMm6 DxBgy00zU Uju 11 0 q 8-11-11 16-0-0 182-0 20-4-8 25-11-15 34-0-0 35-0 Q 1-0 0 8-11-11 7-0-5 2-0-0 2-4-8 5-7-7 8-0-1 1 -0-0 4.00 F12 3x12 = 2.00 12 10-64 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr YES BCDL 10.0 Code FBC2017/TPI2014 LUMBER - TOP CHORD 2x4 SP M 30 *Except* 3-5,6-7: 2x4 SP M 31 BOT CHORD 2x4 SP M 30 WEBS 2x4 SP No.3 *Except* 5-14: 2x4 SP M 30 OTHERS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-169(LC 8) Max Uplift 2=-803(LC 10). 9=803(LC 10) Max Grav 2=1312(LC 1), 9=1312(LC 1) 6x10 MT18HS = 5x6 = 5x6 = 3x6 = Scale = 1:61.9 CSI. DEFL. in (loc) Vdefl Lid PLATES GRIP TC 0.81 Vert(LL) 0.69 14 >590 360 MT20 244/190 BC 0.93 Vert(CT)-0.9214-17 >443 240 MT18HS 244/190 WB 0.86 Horz(CT) 0.34 9 n/a n/a Matrix -MS Weight: 157 lb FT = 0% BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-4=-5491/3336, 4-5=-5095/3071, 5-6=2314/1551, 6-8=-2398/1533, 8-9=3199/1981 BOTCHORD 2-14=-3040/5224, 13-14=-1195/2361, 12-13=-1123/2199, 11-12=1731/3001, 9-11 =-1 731/3001 WEBS 4-14=-492/513, 5-14=-1707/2959, 5-13=-405/196, 6-13=179/522, 8-12=-893/660, 8-11=0/303 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2 considers parallel to grain value using ANSI1TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=803, 9=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.88182 MiTek USA, Inc. FL Cart 6834 6904 Parke East Blvd. Tampa FL 33610 Data: April 3,2020 ®WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/192020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall MiTek' building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord'members only. Additional temporary and permanent bracing 1 V� iTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safetylnformation available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884599 M11323 A7 SPECIAL 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:30 2020 Page 1 ID: WSJgpGwalPpeur6hk9UjG5yuFUL-OIPUnQCcHygOmYBnUkXWryTIFi145CtN9gaVwrzUUjt t1-0 q 8-10-10 14-0-0 20-0-0 25-11-15 34-0-0 35-0-q i-0-0' 8-10-10 5-16 6-0-0 511-15 8-0-1 0-0 Scale = 1:60.8 5x8 = e nn 5x6 = 5x12 = 2x3 II 3x6 = 3x12 = 2.00 F12 10-6-4 14-0-0 20-4-8 25-11-15 34-0-0 ' 10-6-4 3-5-12 6�-8 5-7-7 8-0-1 Plate Offsets (X,Y)— [2:0-1-15,Edge1, [4:0-4-0,0-2-31, [7:0-0-2,Edge1 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/defl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.83 Vert(LL) 0.66 11 >616 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 Be 0.90 Vert(CT) -1.10 10-11 >369 240 MT18HS 244/190 BCLL 0.0 Rep Stress Incr YES WB 0.95 Horz(CT) 0.34 7 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 147 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 4-0-2 oc bracing. WEBS 2x4 SP No.3 'Except* 4-11: 2x4 SP M 30 REACTIONS. (size) 2=0-8-0, 7=0-8-0 Max Horz 2=-149(LC 8) Max Uplift 2=-803(LC 10), 7=803(LC 10) Max Grav 2=1312(LC 1), 7=1312(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5484/3370, 3-4=-5116/3126, 4-5=2229/1544, 5-6=2448/1599, 6-7=3169/1993 BOT CHORD 2-11=-3071/5219, 10-11 =-1 590/2874, 9-1 0=-1 738/2968, 7-9=-1738/2968 WEBS 3-11=-419/443, 4-11=-1466/2647, 4-10=-812/448, 5-10=205/487, 6-10=-785/575, 6-9=0/272 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 pelf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except Qt=lb) 2=803, 7=803. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 A WARNING - Verity design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5119/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall pp �/� building design. Bracing indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing M!Tek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?P/r Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884600 M11323 AB SPECIAL 1 1 Job Reference (optional) unambers truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:31 2020 Page 1 ID: WSJgpGwalPpeur6hk9UjG5yuFUL-Uxzs_mCE2FoFOil_2R210AOTj6eKc jE WOUJ2SHzUUjs T1-0-q 8-8-4 12-0-0 15-8-4 20-4-8 22-0-0 24-8-12 34-0-0 35-0-Q 1-0-0' 8-8-4 3-3-12 3-8-4 4-8-4 1- 2-021 2 9-3-4 0-0� 5x6 = 4.00 12 3x4 = 2x3 II 5x8 = 21 5 6 22 7 ,,, Scale Scale = 1:60.6 N M I� a 0 d 12 11 5x12 = 3x4 = 4x5 = 3x12 = 2.00 12 34-0-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017lrP12014 CSI. TC 0.78 BC 0.90 WB 0.69 Matrix -MS DEFL. in (loc) I/deft Lid Vert(LL) 0.65 12-13 >624 360 Vert(CT) -1.08 12-13 >379 240 Horz(CT) 0.33 9 file n/a PLATES MT20 MT18HS Weight: 154 lb GRIP 244/190 244/190 FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 3-11-11 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0 Max Horz 2=-129(LC 8) Max Uplift 2=-803(LC 10), 9=803(LC 10) Max Grav 2=1312(LC 1), 9=1312(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-5488/3444, 3-4=-5117/3183, 4-5=3911/2497, 5-6=2576/1770, 6-7=258611779, 7-8=-266311762, 8-9=-3021/1971 BOT CHORD 2-13=-314315224, 12-13=-1956/3292, 11-12=-1369/2481, 9-11=-1705/2827 WEBS 3-13=-3961420, 4-13=-102811721, 5-13=-300/797, 5-12=-894/601, 6-12=-265/263, 7-12=-294/391, 7-11=-374/691, 8-11=535/502 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. ' This item has been 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. electronically Signed and 7) Bearing at joint(s) 2 considers parallel to grain value using ANSIITPI 1 angle to grain formula. Building designer should verify sealed by Velez, Joaquin, PE capacity of bearing surface. using a Digital Signature. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) 2=803, Printed copies Of this 9=803. document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 6904 Parke East Blvd. Tampa FL 33610 Data: April 3,2020 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 511912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design Into the overall Inv 11• building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing iVliTek� is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job ss Truss Type 0ty PlyTJob T19884601 Mff1323 rA9 HIP 1 rence (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:32 2020 Page 1 ID:_etC1cxC3ixW?huls?ypJyuFUK-y7XEC6DspZw6OsKAc9Z xNZ18W4CZ7Mfd83c?jzUUjr 1T -0-Q 6-7A 10-0-0 15 2-14 20 4-0 24-0-0 174 34-0-0 35-0-Q -0-0 6-7-15 3-4-1 5-2-14 5-1-2 3-8-0 3.4-1 6-7-15 1-0-0 4.00 12 4x4 = 3x4 = 2x3 II 4x8 = 4 24 525 26 6 27 7 Scale = 1:58.6 rr M 0 Icl, d 3x5 = 3x8 = 3x6 = 6x8 = 3x6 = 3x4 = 3x5 20-4-0 LOADING (psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC2017ITP12014 CSI. TC 0.35 BC 0.54 WE 0.89 Matrix -MS DEFL. Vert(LL) Vert(CT) Horz(CT) in (loc) I/deft Lid -0.18 11-21 >917 360 -0.38 11-21 >432 240 0.02 13 nla n/a PLATES GRIP MT20 244/190 Weight: 156 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 5-11-9 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 2=0-8-0, 9=0-8-0, 13=0-8-0 Max Horz 2=109(LC 9) Max Uplift 2=-430(LC 10), 9=249(LC 10), 13=928(LC 10) Max Grav 2=685(LC 19), 9=386(LC 20), 13=1616(LC 1) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1275/1025, 3-4=-913/708, 4-5=829/705, 5-6=-565/807, 6-7=565/807, 7-8=-104/278, 8-9=-341/235 BOT CHORD 2-15=-836/1187, 13-15=-34/309, 11-13=-256/348, 9-11=124/304 WEBS 3-15=-425/501, 5-15=-444/665, 5-13=121511079, 6-13=-264/300, 7-11=-255/396, 8-11 =-461/521. 7-13=-837/703 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 24-13, Interior(1) 2-4-13 to 5-2-5, Exterior(2) 5-2-5 to 14-9-11, Interior(1) 14-9-11 to 19-2-5, Exterior(2) 19-2-5 to 28-9-11, Interior(1) 28-9-11 to 31-7-3, Exterior(2) 31-7-3 to 35-0-0 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 pelf bottom chord live load nonconcurrent with any other live loads. `This This item has been 5) truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. electronically Signed and 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) sealed by Velez, Joaquin, PE 2=430, 9=249,13=928. using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6834 6904 Parke East Blvd. Tampa FL 33610 Data: April 3,2020 A WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/192020 BEFORE USE. Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall �• building design. Bracing Indicated is to prevent buckling of Individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSVrPII Quality Criteria, DSB-89 and BCS1 Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type Qty Ply M11323T19884602 FHPss M11323 GRA 1 1 Job Reference (optional) Chambers truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 1 I D:_etC1 cxC3ixVV?huls?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq 71-0•q 8-0-0 11-1-1 17-0.0 18-6-0 22-2-2 26 0-0 34-0-0 35 0-0 8-0-0 3-1-1 5-10-15 1-0-0 3 8-2 3-9-14 8-M -0-0 THIS TRUSS IS NOT SYMMETRIC. PROPER ORIENTATION IS ESSENTIAL. 4x4 = 11 14 Scale = 1:60.6 3x5 —_ 3x6 II 3x6 = 6x8 = 3x6 = 6x8 = 4x4 = 6x8 = TRUSS DESIGNED FOR WIND LOADS IN THE PLANE OF THE TRUSS ONLY. FOR STUDS EXPOSED TO WIND (NORMAL TO THE FACE), SEE STANDARD INDUSTRY GABLE END DETAILS AS APPLICABLE, OR CONSULT QUALIFIED BUILDING DESIGNER AS PER ANSIrrPI 1. 8-0-0 34-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.91 Vert(LL) 0.20 24-35 >914 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.57 Vert(CT) -0.24 29-32 >552 240 BCLL 0.0 Rep Stress Incr NO WB 0.98 Horz(CT) 0.02 22 file n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MS Weight: 194 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 4-2-5 oc purlins. BOT CHORD 2x4 SP M 30 Except: WEBS 2x4 SP No.3 1 Row at midpt 8-21 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. JOINTS 1 Brace at Jt(s): 7, 8, 19, 17, 14 REACTIONS. All bearings 0-8-0. (lb) - Max Horz 2=-179(LC 6) Max Uplift All uplift 100 lb or less at joints) except 2=-351(LC 8), 27=-1168(LC 8), 26=-1495(LC 8), 22=-625(LC 8) Max Grav All reactions 250 lb or less atjoint(s) except 2=487(LC 17), 27=2232(LC 13), 26=2929(LC 14), 22=984(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-621/387, 3-5=-304/838, 5-7=-588/1209, 7-8=-588/1209, 8-12=-588/1209, 12-13=-588/1209, 13-15=-588/1209, 15-16=-588/1209, 16-18=-588/1209, 18-20=-2230/1280, 20-21=2230/1280, 21-22=2271/1263, 6-9=-126/305, 9-11 =-1 06/363, 11-14=-1931412, 14-17=-94/271, 19-21 =-1 43/272 BOT CHORD 2-29=-247/677, 27-29=-189/540, 26-27=-779/446, 24-26=-411/653, 22-24=1083/2108 WEBS 3-29=-500/1176, 3-27=-1766/911, 5-27=-748/622, 5-26=546/351, 13-26=946/617, 18-26=-2412/1474, 18-24=846/1780, 21-24=-35/351, 4-5=-608/514, 19-20=335/305, 14-15=-556/407, 11-12=-254/54 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. 11; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are 2x3 MT20 unless otherwise indicated. 5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 6) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 351 lb uplift at joint 2, 1168 lb uplift at joint 27, 1495 lb uplift at joint 26 and 625 lb uplift at joint 22. 8) Girder carries hip end with 8-0-0 end setback. 9) Graphical purlin representation does not depict the size or the orientation of the purlin along the top and/or bottom chord. 10) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others. 11) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 8634 8904 Parke East Blvd. Tampa FL 33610 Date: ADril 3.2020 andard WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall �v building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/rPlf Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884602 M11323 GRA HIP 1 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:33 2020 Page 2 ID _etClcxC3ixVV?huls?ypJyuFUK-QK4cPSEUat2zdOvM9s4DTb5n5vPvlY6proo9XAzUUjq LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-3=54, 21-23=54, 29-30=-20, 24-29= 47(F=-27), 24-33=20, 3-11=-126(F=-72), 11-21=126(F=-72) Concentrated Loads (lb) Vert: 29=-641 (F) 24=641(F) ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 511912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall p �� building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IV IiTek� is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI1rPI1 quality Criteria,DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884603 M11323 GRB HIP 1 1 Job Reference o tional Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:34 2020 Page 1 ID: SrRaEyyrg04M78G4raWB LWyuFUJ-u We?doF7LAApF9UZjacSOoe_iJjP10by4SYi3czUUjp r1-0-q 8.0-0 13-8-0 17-0-0 20-4-0 26-M 34-0-0 35-0-Q -0-0 8-0-0 5-8-0 3-0-0 3 4-0 5.8.0 8-0-0 1-0 0 Scale = 1:58.6 4.00 12 4x6 = 5x12 MT18HS = 3x6 11 LOADING (psf) SPACING- 2-0-0 TCLL 20.0 Plate Grip DOL 1.25 TCDL 7.0 Lumber DOL 1.25 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code FBC2017/TPI2014 4x10 = 2x3 I I 4x6 = 23 4 5 6 5x6 = 6x12 = 5x12 MT18HS = 2x3 11 7 24 6x12 = 5x6 = 3x6 11 CSI. DEFL. in (loc) I/deft L/d TC 0.80 Vert(LL) 0.22 16-19 >999 360 BC 0.68 Vert(CT) -0.30 16-19 >820 240 WB 0.90 Horz(CT) 0.06 9 n/a n/a Matrix -MS LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD BOT CHORD 2x4 SP M 30 BOT CHORD WEBS 2x4 SP No.3 `Except* WEBS 4-14,7-13: 2x6 SP No.2 REACTIONS. (size) 2=0-8-0, 13=0-8-0, 9=0-8-0 Max Horz 2=90(LC 7) Max Uplift 2=853(LC 8), 13=2590(LC 8), 9=-345(LC 8) Max Grav 2=1451(LC 13), 13=4743(LC 15), 9=528(LC 14) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-3625/1950, 3-4=-2080/1236, 4-6=2080/1236, 6-7=129612589, 7-8=1296/2589, 8-9=-751 /370 BOT CHORD 2-16=-1729/3460, 14-16=-1753/3525, 11-13=-262/733, 9-11=-241/668 WEBS 3-16=-435/1209, 3-14=-1552/774, 4-14=-837/691, 7-13=-878/713, 8-13=-3635/1919, 8-11=-432/1204,6-14=-145312814,6-13=-3198/1807 46 = PLATES GRIP MT20 244/190 MT18HS 244/190 Weight: 153 lb FT- = 0% Structural wood sheathing directly applied or 3-1-14 oc purlins. Rigid ceiling directly applied or 5-3-14 oc bracing. 1 Row at midpt 3-14, 8-13, 6-13 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) All plates are MT20 plates unless otherwise indicated. 5) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. ' This item has been 6) This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. electronically Signed and 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 853 lb uplift at joint 2, 2590 lb uplift at sealed by Velez, Joaquin, PE joint 13 and 345 lb uplift at joint 9. using a Digital Signature. 8) Girder carries hip end with 8-0-0 end setback. Printed copies of this 9) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 967 lb down and 461 lb up at 26-0-0, and 967 lb down and 461 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the document are not considered responsibility of others. signed and sealed and the 10) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). Signature must be Verified LOAD CASE(S) Standard on any electronic copies. 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6634 Uniform Loads (plf) Vert: 1-3=54, 3-8=1 31 (F=77), 8-10=-54, 16-17=-20, 11-16=49(F=29), 11-20=-20 6004 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with Mi rek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not AA a truss system. Before use, the building designer must verify the applicability of design parameters and properly incorporate this design into the overall t building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANS11TP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply M11323 T19884603 Mf1323 GRB HIP 1 1 Job Reference (optional) cnambers truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 2 ID: S rRaEyyrg04M78 G4ra WB L WyuFUJ-Mi C Ng7Gl6 U IgtJ31H H7hYOB9Sj3em Sr6J6H Gb2zU Ujo LOAD CASE(S) Standard Concentrated Loads (Ib) Vert: 16=-641(F) 11=641(F) ® WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall, building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• Is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP/1 Quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job ss Truss Type City Ply M11323 FJ2 T19884604 Mf1323 MONO TRUSS 8 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:35 2020 Page 1 ID:xl?zS IZTbJCDIIfGPH1 QukyuFU I-MiCNg7G16UlgtJ31HH7hYOBJ7jCDmgz6J6HGb2zUUjo -1-0-0 2-M 1-0-0 2-0-0 Scale = 1:7.8 3x4 = 2-0-0 2-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) IIdefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) -0.00 7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.07 Vert(CT) -0.00 7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC20171TPI2014 Matrix -MP Weight: 8 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 2-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=67(LC 10) Max Uplift 3=28(LC 10), 2=136(1_C 10), 4=-3(LC 7) Max Grav 3=39(LC 15), 2=141(LC 1), 4=31(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 28 lb uplift at joint 3, 136 lb uplift at joint 2 and 3 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL cart 6834 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 A WARNING - Vedfy design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not a truss system. Before use, the building designer must vedfy the applicability of design parameters and property incorporate this design Into the overall building design. Bracing indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSIITP11 Qualify Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Jab Truss Truss Type Qty Ply M11323 T19884605 M11323 J4 ]MONO TRUSS 8 1 Job Reference (optional) unambers Truss, Inc., Fort Pierce, FL 1-0-0 3x4 = 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1 ID:PDYLfd_5MdK4MSQTz?ZfRxyuFUH-gvml2TGNtoQXUTexr?ew5DjQW7UmV7DFYm1 p8UzUUjn 4-0-0 Scale = 1:11.1 LOADING (psi) SPACING- 2-0-0 CSI. DEFL. in (loc) 11defl Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.39 Vert(LL) 0.02 4-7 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.37 Vert(CT) -0.02 4-7 >999 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TPI2014 Matrix -MP Weight: 14 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD Structural wood sheathing directly applied or 4-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=104(LC 10) Max Uplift 3=-80(LC 10), 2=161(LC 10), 4=-7(LC 10) Max Grav 3=90(LC 1), 2=207(LC 1), 4=69(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. lit; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 80 lb uplift at joint 3, 161 lb uplift at joint 2 and 7 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6834 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 ® WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE, *R Design valid for use only with MTek® connectors. This design is based only upon parameters shown, and is for an individual building component, not pp, a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design Into the overall Iti.�` building design. Bracing Indicated Is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing IVY l is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the pppTek• fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/fP/i Duality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Qty Ply T19884606 M'11323 J6 MONO TRUSS 8 1 [M11323 Job Reference o floral Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:36 2020 Page 1 ID:tP6jtz_j7xSx_c_fXi4uz9yuFUG-qvm 12TGNtoQXUTexr?ew5DjR?7M UV7DFYm 1 p8UzU Ujn -1-0-0 6-0-0 1-0-0 6-M Scale = 1:14.6 3x4 = 6-0-0 6-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.36 Vert(LL) 0.11 4-7 >629 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.83 Vert(CT) -0.12 4-7 >617 240 BCLL 0.0 Rep Stress [nor YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 20 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=142(LC 10) Max Uplift 3=-131(LC 10). 2=194(LC 10), 4=-8(LC 10) Max Grav 3=145(LC 1), 2=279(LC 1), 4=102(LC 3) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWF.RS (directional) and C-C Exterior(2) zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 131 lb uplift at joint 3, 194 lb uplift at joint 2 and 8 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6834 6904 Parke East Blvd. Tampa FL 33610 Date: April 3,2020 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy Incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek Is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSYTP11 quality Criteria, DSB-89 and SCSI Building Component 6904 Parke East Blvd. Safety information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Truss Type Oly Ply T1988M11323 J6 MONO TRUSS 201[M11323 Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 3x5 = 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:37 2020 Scale = 1:17.4 8-0-0 8-0-0 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) I/deft Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.62 Vert(LL) 0.26 4-7 >367 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.38 Vert(CT) -0.30 4-7 >319 240 BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(CT) -0.00 3 n/a n/a BCDL 10.0 Code FBC2017/TP12014 Matrix -MP Weight: 26 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS. (size) 3=Mechanical, 2=0-8-0, 4=Mechanical Max Horz 2=180(LC 10) Max Uplift 3=-175(LC 10), 2=228(LC 10), 4=-15(LC 10) Max Grav 3=188(LC 1), 2=352(LC 1), 4=145(LC 3) FORCES. (lb) -Max. Camp./Max. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. II; Exp C; Encl., GCpi=0.18; MWFRS (directional) and C-C Exterior(2) -1-0-0 to 2-4-13, Interior(1) 2-4-13 to 3-1-13, Exterior(2) 3-1-13 to 7-11-8 zone;C-C for members and forces & MWFRS for reactions shown; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 175 lb uplift at joint 3, 228 lb uplift at joint 2 and 15 lb uplift at joint 4. This item has been electronically signed and sealed by Velez, Joaquin, PE using a Digital Signature. Printed copies of this document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cart 6634 6904 Parke East Blvd. Tampa FL 33610 Data: April 3,2020 WARNING -Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE MII-7473 rev. 5/19/2020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an individual building component, not �e a truss system. Before use, the building designer must verify the applicability of design parameters and property incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek' is always required for stability and to prevent collapse with possible personal Injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI?17/1 Quality Criteria, DSB-89 and BCSI Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Job Truss Type Qty Ply M11323 T19884606 ]Truss M1:1323 KJ8 MONO TRUSS 4 1 Job Reference (optional) Chambers Truss, Inc., Fort Pierce, FL 8.240 s Mar 9 2020 MiTek Industries, Inc. Fri Apr 3 07:54:38 2020 Page 1 ID:Lcg54J?LuEancmZr4Qb7 WMyuFUF-nHuVT9ldOPgFknoKyPgOAeooawBGzwZY?4 WwC NzUUjI 11-3-0 Scale = 1:20.3 3x4 = 5 3x4 = 7-3-4 --' _- 3-11-12 LOADING (psf) SPACING- 2-0-0 CSI. DEFL. in (loc) Udefl L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.29 Vert(LL) 0.07 7-10 >999 360 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.30 Vert(CT) -0.12 7-10 >999 240 BCLL 0.0 Rep Stress Incr NO WB 0.46 Horz(CT) 0.02 6 n/a n/a BCDL 10.0 Code FBC2017frP12014 Matrix -MS Weight: 44 lb FT = 0% LUMBER- BRACING - TOP CHORD 2x4 SP M 30 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2x4 SP M 30 BOT CHORD Rigid ceiling directly applied or 8-9-6 oc bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 4=Mechanical, 2=0-11-5, 6=Mechanical Max Horz 2=244(LC 8) Max Uplift 4=-205(LC 8), 2=305(LC 8), 6=286(LC 8) Max Grav 4=245(LC 13), 2=466(LC 1), 6=590(LC 13) FORCES. (lb) -Max. Comp./Max. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 2-3=-1151/523 BOT CHORD 2-7=-687/1126, 6-7=-687/1126 WEBS 3-7=0/330, 3-6=1236/755 NOTES- 1) Wind: ASCE 7-10; Vult=165mph (3-second gust) Vasd=128mph; TCDL=4.2psf; BCDL=3.Opsf; h=14ft; B=52ft; L=34ft; eave=6ft; Cat. ll; Exp C; Encl., GCpi=0.18; MWFRS (directional); Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 205 lb uplift at joint 4, 305 lb uplift at joint 2 and 286 lb uplift at joint 6. 6) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard This item has been 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 electronically signed and Uniform Loads (plf) sealed by Velez, Joaquin, PE Vert: 1-2=54 using a Digital Signature. Trapezoidal Loads (plfp Printed copies of this Vert: 2=0(F=27, B=27)-to-4=-152(F=-49, B=49), 8=0(F=10, B=10)-to-5=-56(F=18, B=-18) document are not considered signed and sealed and the signature must be verified on any electronic copies. Joaquin Velez PE No.68182 MiTek USA, Inc. FL Cert 6834 6904 Parke East Blvd. Tampa FL 33810 Date: April 3,2020 WARNING - Verify design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE Mll-7473 rev. 5/1912020 BEFORE USE. Design valid for use only with MiTek® connectors. This design Is based only upon parameters shown, and is for an Individual building component, not a truss system. Before use, the building designer must verify the applicability of design parameters and propedy incorporate this design into the overall building design. Bracing Indicated is to prevent buckling of individual truss web and/or chord members only. Additional temporary and permanent bracing MiTek• is always required for stability and to prevent collapse with possible personal injury and property damage. For general guidance regarding the fabrication, storage, delivery, erection and bracing of trusses and truss systems, see ANSI/TPl1 Quality Criteria, DSB-89 and BCS/ Building Component 6904 Parke East Blvd. Safety Information available from Truss Plate Institute, 2670 Crain Highway, Suite 203 Waldorf, MD 20601 Tampa, FL 36610 Symbols Numbering System ® Genera9 Safety Notes PLATE LOCATION AND ORIENTATION 3 � /4 Center plate on joint unless x, y offsets are indicated. 6-4-8 dimensions shown in ft-in-sixteenths (Drawings not to scale) 1 Failure to Follow Could Cause Property P Y Damage or Personal Injury Dimensions are in ft-in-sixteenths. 1. Additional stability bracing for truss system, e.g. Apply plates to both sides of truss 1 2 3 diagonal or X-bracing, is always required. See BCSI. and fully embed teeth. TOP CHORDS 2. Truss bracing must be designed by an engineer. For 0'116 c1-2 c2-3 wide truss spacing, individual lateral braces themselves I WEBS �aQ 4 tY m O may require bracing, or alternative Tor bracing should be considered. 3. Never exceed the design loading shown and never _ O U a 2 stack materials on inadequately braced trusses. o_ O 4. Provide this truss design to the 00 copies of building EL designer, erection supervisor, property owner and For 4 x 2 orientation, locate c7-8 c6-7 c5-6 I-_ BOTTOM CHORDS all other interested parties. plates 0- 'rid' from outside p 5. Cut members to bear tightly against each other. edge of truss. 8 7 6 5 6. Place plates on each face of truss at each joint and embed fully. Knots and wane at joint This symbol indicates the JOINTS ARE GENERALLY NUMBERED/LETTERED CLOCKWISE locations are regulated by ANSI/TPI 1. required direction of slots in AROUND THE TRUSS STARTING AT THE JOINT FARTHEST TO THE LEFT. 7. Design assumes trusses will be suitably from connector plates. environment in accord with ANSI/TPotected the j' Plate location details available in MiTek 20/20 CHORDS AND WEBS ARE IDENTIFIED BY END JOINT NUMBERS/LETTERS. 8. Unless otherwise noted, moisture content of lumber software or upon request. shall not exceed 19% at time of fabrication. 9. Unless expressly noted, this design is not applicable for PLATE SIZE PRODUCT CODE APPROVALS use with fire retardant, preservative treated, or green lumber. ICC-ES Reports: 10. Camber is a non-structural consideration and is the The first dimension is the plate responsibility of truss fabricator. General practice is to 4 x 4 width measured perpendicular ESR-1311, ESR-1352, ESR1988 camber for dead load deflection. to slots. Second dimension is the length parallel to slots. ER-3907, ESR-2362, ESR-1397, ESR-3282 11. Plate type, size, orientation and location dimensions indicated are minimum plating requirements. LATERAL BRACING LOCATION 12. Lumber used shall be of the species and size, and in all respects, equal to or better than that specified. Indicated by symbol shown and/or by text in the bracing section of the Trusses are designed for wind loads in the plane of the truss unless otherwise shown. 13. Top chords must be sheathed or purlins provided at spacing indicated on design. output. Use T or I bracing if indicated. Lumber design values are in accordance with ANSI/TPI 1 14. Bottom chords require lateral bracing at 10 ft. spacing, section 6.3 These truss designs rely on lumber values or less, if no ceiling is installed, unless otherwise noted. BEARING established by others. 15. Connections not shown are the responsibility of others. Indicates location where bearings 16. Do not cut or alter truss member or plate without prior approval of an engineer. (supports) occur. Icons vary but reaction section indicates joint © 2012 MiTek® All Rights Reserved 17. Install and load vertically unless indicated otherwise. number where bearings occur. Min size shown is for crushing only. 18. Use of green or treated lumber may pose unacceptable environmental, health or performance risks. Consult with project engineer before use. Industry Standards: 19. Review all portions of this design (front, back, words ANSI/TPI1: National Design Specification for Metal and pictures) before use. Reviewing pictures alone is not sufficient. Plate Connected Wood Truss Construction. DSB-89: Design Standard for Bracing. 20. Design assumes manufacture in accordance with BCSI: Building Component Safety Information, MiTek ANSI/TPI 1 Quality Criteria. Guide to Good Practice for Handling, Installing & Bracing of Metal Plate 21.The design does not take into account any dynamic Connected Wood Trusses. MiTek Engineering Reference Sheet: Mll-7473 rev. 5/19/2020 or other loads other than those expressly stated.