HomeMy WebLinkAboutBuilding Plans5/8" thick x 6"
finished stucco
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL 411451.12
26 ga. 5v crimp metal roofing attached to plywood deck using 99 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L" o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detail on this sheet
�5/8" thick II ht textured -i
stucco on typical concrete
-I block construction
LEFT ELEVATION
12
SLOPE 4
3 -'
r----------------------------
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
24 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4 side laps and V end
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced 4"
o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment staggered
on this sheet
I
uI
SCALE: 1/4" = I'-O"
ELE\/ATiON MOTES:
- Overhangs at 1'-0" unless otherwise noted on Roof Plan
- Roof pitch at 4:12 unless otherwise noted
- An( changes to tfils plan shall be submitted to the architect
for approval in writing prior to starting construction.
- Return ALL Stucco Bands into Window or Door.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11451.12
26 ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment Installed with min. 4' side laps and 6" ens
laps fastened with corrosion resistant tin caps and with 1-25" ring shank nail
sppago L" o.c. at all laps and two staggered rows 12" o.c. in field. Attac
dec to trusses using attachment detail on this sheet
12
'SLOPE 1.4
�■L■J
5/8" thick light textured
stucco on typical concrete
block construction
REAR ELE\/ATION
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
21. ga. 5v crimp metal roofing attached to plywood deck using #9 x 1-5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4' side laps and 6" and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank nails
spaced L" O.G. sit all laps and two staggered rows 12" o_c. in field. Attach
deck to trusses using at
data on this sheet
©❑
SCALE: 1/4" = 1'-0"
12
12 SLOPE 4
SLOPE 4
T
5/8inished stucco
'°
F+
®
a
1�
5/8" thick x 6" smooth
finished stucco bands
L24-.
® ®
®
®
---------------------------------
5/8" thick light textured
stucco on typical concrete
block construction
RIGHT ELEVATION
SCALE: 1/4" = 1'-0"
Product Approval Submittal Affidavit
Opening Schedule Swing Doors, Overhead Doors, Sliding Doors, Windows & Skylights
Opening
Type
NOA/FL
NEg
Product
Model
Manufacturer
Glass
Attachment method
TEST tion
Da
Design Pressure
of Approved Tests
1.2.3
t4
FLU 23358.2
Single Hung
SH 4100
Impact
CGI
5/IL"
1/4" die. tapcons w/ min. 1
mien. spaced
eses specified
3/ penetration to be
to
in Product apppro approval
+ 55.0/-65.0 psf
A
IL-0330.02
Garage Door
Model 824/811
9•-4" max width
IL'-O" max height
DAB
EF7Overhead
sc ber"vwf neti a .°c°""w1�`+siatc s..�..�i=..t a �..
i c "
i7�siliereerm°Am'::i°�r`«Cie`neainns
,.,, eri .as. ae.ne. _� w ere:u, awn'9 w oredw: ap,rw.i
10-9-21
+50.0/-60.0 psf
B
FLU 16614.1
Fiberglass
Des9ko
Smooth Pron Pro
Jeld-Wen
I/4" did. tapeon with min 1.25" enibedmeM. at 3" max
from corners and n.5" ox. max thereafter in head and jambe
+ 50.0 PSF
C
FLU 29018.2
SlidingGlass
Door
Series 4130A
SGD
CGI
I" nom
Type 'GSA
I/4" da. tapcons w/ min. 1 3/8" penetration to be
spaced per product approval. Contractor shall adhere to
min. 2 1/2" edge datances specified in Product approval
+ 55.0/-65.0 sf
- p
Product
NOA/FL
NUMBER
Model #
Manufacturer
Attachment Method
TEST
rap•ation
Date
Design Pressure
of Approved Tests
Mullions
18-0129.08
1" x 3" x 1/8"t
CGI
Install using (4) 114" tapcon with min. 1.5" embeddment at each clip
to wall connection as shown in product approval
+ 60.0 PSF
Roof
FL# IIL51.12
5V Crimp
Metal Roofin g
Gulf Coast Supply
and manufacturing
2L ge Sy crimp metal roofing attached to plgwood deck using 841 x Ig`
wood seises with self seatng rasher at 12" o.c. max seating over ASTM D
(type 2) 30 Ib relt underlayment installed with min. 11 oifl laps and 6" and
laps fastened with corrosion resistant tin caps and with 1. 5' ring shank nails
rced L ". at all laps and two staggpared rows 12 o.c. in field. Attach
k to trusses uarng attachment detau on roof plan
- 108.5 PSF
Siding
stucco on Block
Soffit
FLU 12198.3
Model T4 12" vented
Vinyl Soffit
Kagcan
Install using 2" x 2" battens at V o.c. screwed to soffit framing using
#8 x 3" wood screws at each truss. Install soffit to battens using
0.12' dia. x 1.5" Iona rina shank nails with 3/8" di . head.
+55.0/-35.0 PSF
Hurricane
Panels
I have reviewed the above and approved it by my seal below. ( Architect or Engineer of Record
2" x 4" top plate 1/2" drywall ceiling on truss bottom cord
I/2" drywall on
2" x 4" studs at 14" O.C.
base -board -----\ 11 11 .,2" x 4" P.T. bottom plate
\ 4" concrete slab with fibermesh OR
6'xV #10/10 WWM on L mil Visqueen over
clean compacted termite treated fill
interior Non -Bearing Partition
nts
Braden It
Braden AiA, PA
Architects
- Planners
411
S.E. Coconut Avenue
Tel
: (112) 281-8258
Fax
: (112) 281-8283
E-mail:
bradenaiaticomcast. net
Stuart. FL
349% #AAC000032
5/8" thick light textured / \ Return Stucco banding
stucco on typical concrete back to front door wall
block construction as shown
FRONT ELE\/ATiON
Wynne Building Corp.
The Cottage
Spanish Lakes
St. Lucie County Florida
SCALE: 1/4" = 1'-0"
8" thick x 6" smooth
finished stucco bands
ALL CONTRACTOR WARRANTIES BEGIN WHEN THE CLOSING
OCCURS BETWEEN THE BUYER AND WYNNE BUILDING CORP
AND WILL CONTINUE FOR ONE YEAR FROM THAT DATE
PERMITTING INFORMATION (FORM 100)
Florida Building Code Residential: Lth Edition and ASCE 1-10 for Wind Loading
Bmidilni Design is. Enclosed Risk Categorg: II Wind Velocity: I45 mph ultimate
Mean
oaf Height: II'-0" Roof Pitch: 4:12
OV09
Internal Pressure Coefficient: +0IS
Subjectability to damage from: Weathering: Negligible Termites: Veru Heavu
Width of Roof End Zone: 3`-4" Wind Speed: I6.5 mph ultimate
Wind Exposure Classification: C
1.21 x O.L = 0.12G
Adjustment factor for Exposure Height: ASD dengn
Load Combination. ASCE 1-10 Section 2.4 DL+LL; DL+O.LWL; O.LDL+O.LIAL
Components t Cladding Wind Pressure (NET) Roof Zone. I. +20.6/-32.4 psf
Roof Zone: 2. +20.6/-51.0 pat
Roof Zone: 3. +20.6/-84.O psf
Components t Cladding Wall End Zone Width: 3'-4"
Components t Cladding Wind Pressure (NET) Well Zone: 4.+35.8/-38.1 psf
Roof Zone I
Wall Zone: 5. +35.8/-41.8 psf
Walls Zone 4
Components t Cladding Wind Pressure (NET) on Garage Door: +32.0/-40.3Pat
Shear Walls Considered for Structure? Yes
Continuous Load Path Provided?
= Roof Zone 2
es
Walls Zone 5
Are Components an Cladding Detai s Provided? Yes
END ZONE
Minimum Sal Bearing Pressure:2 500 pal. Presumptive: X Bg Test: psi
= Corner Zones
SEE PRODUCT APPROVAL ; O IMPACT PROTECTION F ROPE INGS
Roof Zone 3
ROOF LIVE LOAD: 3-1 pat ROOF DEAD LOAD: 10 psf
FLOOR LIVE LOAD: `1- Pat FLOOR DEAD LOAD: 10 Pat
JOB ADDRESS:
GARAGE
RIGHT
Date Drawn
3-24-20
Drawn bg:
C.C.U.
Checked by:
D.R.B.
Revisions : Sheet Comm #
FILE COPY 19-221
*t,1E=4E W"D941
OF 5
ST. LI ICIE COUNTY (
QSOCC
rFLOOR PLAN
TYPICAL
NOTES: SCALE 1/4" = 1'-0"
I.
Contractor to verify ALL notes and dimensions prior to
2.
proceeding with work.
Contractor to STRICTLY enforce ALL OSHA Requirements.
3.
ALL Lumber to be used as Beam, Rafters, etc.., to have
a minimum IAOO P.S.I. fiber stress.
4.
No dissimilar metals to touch.
S.
ALL Concrete used for slabs shall be min. 2,500 PSI concrete.
ALL Concrete used for vertical filled cells, cont. tie beams etc.. to
shall be 3,000 P.S.I. concrete and/or 4,000 P.S.I. grout mix
6.
Drywall at ceilings shall be leveled and attached to bottom chord
-1.
of trusses with screws per FBC R-102.3.5.
ALL wood in contact with concrete shall be pressure treated.
8.
ALL wall dimensions are nominal and not finished wall or stud dimensions.
9.
ALL plumbing fixtures to be low flow.
10.
Contractor to Provide Drain at water heater in accordance
with the current edition of the Florida Plumbing Code.
11.
Contractor to Provide a 2'-8" wide door at one bathroom for
handicap accessibility requirements.
12.
Lowest finished floor to be set bg Governing Building Department
13.
surveyor to set in field.
Separation between residence and garage shall be per FBC R302.6
14.
Door between garage and residence shall be 1-3/4"t 20 min. rated door
w.H. = Water Heater
15.
Wall and Ceiling shall have a flame -spread classification of not greater than 200 per FBC R302.9.1
-developed index of not greater than 450 per FBC R302.9.2
16.
11.
Wall and ceiling finishes shall have a smoke
All exposed attic insulation materials installed on attic floors shall have a critical radiant
Exposed foam plastic insulation
Masonr Beam
I" x C P.T. Buck nailed to y
with "aria
flux not less than 0.12 watt per square centimeter.
materials exposed on the underside of the roof deck or on the attic walls shall comply
prior tttaehmend
p
18.
with F.B.C. R316 - see permit info box of code edition
G(��(ppsum board material shall conform to ASTM C36, C19, C415, C514, C630, C931
C` O C1014 all (FBC11 R�OCI 3 5j C1395, or C1396 and shall be installed
,nC1002,
Thickness
Location
Orientation
Framing
Member
Max spacing
of fasteners
Nail azrn options for
installation a dr4mall into
Spacing
MaximumNeils
be
wood framing memrs
Screws
2' x min. thickness
Ceiling
Perpendicular
24'
1'
12"
13ga 1 3/e" long with 19/44" head
0.098" diameter x 11/4" long
annular -ringed or 5d cooler nail
0.080" ilia. x 15/8` long with
Either
16"
8'
I1.
Walls
Direction
IS/L4" head
OR
Ggpsum board nail 0.08L" dia.
x 1 5/8" with 9/32" head.
Coding
Perpendicular
24"
1"
12"
13ga 1 5/8" long with 19/44" head
0.098" dia�Rer x 13/8" long
annular -ringed or Ld coder nail
6„OR
din. x I i/e" long with
16"
Walls
Either
Direction
IV
e"
he
1/44 head
I/4d
OR
Gypsum board nail 0.0915' die.
x I I/e" with l9/L4' head.
Install SGD thru buck into
block with 3/I0 tap -con with
1 1/2" penetration at 6" o.c. max
from each corner and 20." o.c. max
thereafter at head per product approval
Use 3/14" tap -con with
1 1/2" penetration at L" ox, max
from each corner and 20' o.c. max
thereafter at sill per product alprc
19. ALL ceramic A11I,tile sur a es inks and installed
shall conform to ASTM A108.1 thru A108.6,
A1020. Cement, fiber -cement or glass mat gypsum backers in accordance with ASTM
be128 ed as backk backer foOR r ll the and
wall I tile Iindtub areas and manufacturers
panels shower areas.
21. insulation including facings such as retarders or vaporpermeable members installed
within floor -ceiling assemblies, roof -ceiling assemblies, , crawl spaces and attics
shall have a flame spread index not to exceed 25 with an accompanyin smoke
developed index not to exceed 450 when tested in accordance with ASTM E 84,
Insulation shall comply with F.B.C. R316.
Gulf Coast Supply and MFG 5v Crimp Metal roofing FL #11651.12
2(.ga. 5v crimp metal roofing attached to plywood deck using #9 x 1.5"
wood screws with self sealing washer at 12" o.c. max spacing over ASTM D
(type 2) 30 lb felt underlayment installed with min. 4 side laps and L" and
laps fastened with corrosion resistant tin caps and with 1.25" ring shank marl&
deck to trusses usinglattachmentadetai onethisashoot o.c. in field. Attach
Simpson HETA 20 or equal
hurricane r�char at ach truss 12
with (10) I'Od x I I/�" nails PRE-ENGINEERED TRUSSES
( 24' o.c.) supporting Max 4 �- at 24'o.c. TYPICAL
Is101bs uplift \ (shop drawings by manufacturer)
-�
--V\R-30 blown fiberglass
Aluminum Drip
Edge t Fascia
in bottom chord or trusses
1/2' drywall with smooth finmh
2" x L" Sub-Faacra
Two rows of boom block Pilled with concrete
and (U 95 bar cant. in each row. Substitute
Kaycan fill o vent vmyI soPtrt metalled
long
precast lintel filled with concrete and (1) #5
bar cunt. for bottom row over openings
using 1/e' dia shank x 1.5' galy.
roofing nails with 3/8' dia. head par
product approval - we chart sheet #I
" "
1/2 drywall over I x furring
R4.1 ri-foil
strips at IL" o.c. with
insulation on tlipncal 8' Block walls
All drywall to be installed per FBC R"102.3.1
5/8" thick light textured
is light
and shall meet all pertaining ASTM codes.
stucco t concrete
in Mortar to be Type 'M' onlgg proportioned per FBC R401.1
block construction
and Mortar Jonts shall comply with FBC RLO'1.2.1.
Provide Dur-O-Rock at all wet areas (ex showers, tubs etc...)
#5 bar vert. w/
30' overlap
Fill cell with concrete and
(U #5 bar vert. (typical).
at each Pilled cell
Max spacing shall not exceed
48" unless otherwise noted
Wood see foundation plan notes for
ase spacing at openings
4" concrete slab with fibermesh OR
L")d' #10/10 WWM on 6 mil Visqueen over
clean compacted termite treated fill
cs
Grade
�' -- -
�- --d
-
-���I
III_
14"w x 18 Concrete tooting
7i
with (2) #5 bars cont.and # 5
" s at 48" o.c.
I"t transverse bar
AREA CALCULATIONS
Living A/C = 1,304 sq. ft.
Front Porch = 23 sq. ft.
Rear Porch = Ile sq. ft.
Garage = 303 sq. ft,
Total Under Roof= 1150 sq. ft,,
Total Cubic Ft =
T AAV 1
To Septic
Head
f ixed door
sliding door
1 1/2"
281 KTICHEN
2" I MASTEM
BATH
2" J BATH
3"
3" FLAUNDRY
PLUMBING RiSER
I" x 6" P.T. Buck nailed to
block with case hardened nails
prior to door attachment
Masonry Wall
Bottom Trac_`-Tilpical Flooring>�.
Bill Install SGD thru buck into
block with 3/16" tap -con with
sliding D O o r D e t all I penetration at L" .0 max
fromom each corner and 20. o.c. max
thereafter at Jambs per product approval Jamb
At Masonry Wall NTS
Window Schedule
ark
Size
Rou h O en.
window Description
PRESSURE ZONE
FI.
4'-5ye'x 4'-2Ye'
"y""x 5O%"
Single Hung
ZONE 4
I
2.
V-2ya"x 5'-3 ia"
Is' x toe /4"
Sirgle Hung
ZONE 4
7-2yz"x 3'-23'e"
21%"x 38%"
single Hung
ZONE 4
4.
3'-I yak 4'-2 N'e'
38ys"x 50Ye"
Single Hung
ZONE 4
ALL Windows to be aluminum
windows w/ tint
and mullions per elevations.
ALL windows to withstand pressures in permit info box on sheet I
ALL windows in bathrooms to be tempered
All rough opening dimensions to be verified by contractor
with manufacturers specs prior to construction
Door Schedule
Mark
Size
Rough O ening
Door Description
PRESSURE ZONE
A
lo'-O' X 9'-0'
120" x 84'
overhead Garage Dos'
ZONE 5
B
3'-0' X 6'-8"
41 i4"x 83�:'
l2dwilgilless Panel - Inswing
ZONE 4
C
L'-ON X L'-8'
14, x 81 ri' °oi" Sliding Glass, Door ZONE 4
Soli Core - Wood - L-Feral -Sr-Fold Finahed 32' x 81'/2'
D
2'-8" X C-8"
E
2'-8" X L'-8'
Schd Care - Wood - L-Panel
F
2'-8' x V-8' x 1 N'
Solid Care - Wood - to -Pawl - Packet
G
2'-8' x v-8' x I %,
Solid Cora Wood. Steel. or Mason to Door (20 on rated)
H
5'-O' X L'-8'
Solid Care - Wood - Packet
J
X-Le X V-8'
Schd Care - Wood - L-Panel - BI-FOLD
K
2'-8' X V-8'
Solid Core - Wood - L-Panel
L
2'-0' X V-8'
Sohd Core Wood, Steel. or Masorete Doan (20 on rated)
M
2'-0' X L'-8'
Schd Care - Wood - L-Panel - BI-FOLD
N
2'-L' X V-8'
Solid Con - Wood - L-Panel
JL
ALL Exterior doors to withstand pressures stated in permit info
box on sheet 41
GARAGE DOOR SPECIFIED IN PRODUCT APPROVAL FORM AND SHALL
WITHSTAND THE PRESSURES STATED IN PERMIT INFO BOX ON SHEET #1
All rough opening dimensions to be verified by contractor
with manufacturers specs prior to construction
I
0
35'-0"
I
I
wl I I Offio0
00
ONE
o
COV RED
-
-
PO PCH DEN MASTER
©=
BEDROOM
r
I
p
v VUC
©
4-0 V
oN
aoo r� oaIL
o H
I
co
©
Ln
o I
87
W
J
°
GREAII ROOM v
o
o
i CLOSET
I
vinyl
N
I =°= A T
®®
O
Ln
B
5' O 9'-2"
O
jU
I PWD Wrly"osRe `"
DINING
ROOM 1
�r
O
I Tankless WI I
o
H B
I mounted aboveI
48" a.F.f.
�
I O
I
31' x 3L'1
m�
--- -- 1-1 kt� Access
�_
w�p
=_______= ---� 15P
©ACK
Meter
il:m�
vinyl
Help
noosu ANACK
D1
pRYMR
GARAGE
l�,4UNORY
o
KITCHEN
F
b o
r-------------------
I
rs7a]
l
d kl
°a
o
I
1
I
H.B.
ENT Y
O
A/C
/8" drywall
j
1 w
STORAGE
I
LnI
1
Ce]
�O
t
ODISIC'jl
L
0 Q DO
Install windows thru buck into
block with 3/I4" tap -con with
1 1/2" penetration at L' o.c. max
from each corner and 20." o.c. max
thereafter at .iambs and 20' o.c. max
Exterior Pace at head and all per product approval
of wall -\ / \ Buck to be I" x 4" PT
Detail at Windows
I"x4" P.T. Buck nailed to
block with case hardened nails
prior to window attachment
NTS
`I2'-4 %s12'-4
ALL WiNDOWS
TO HAVE
DRYWALL SILLS
INSTALL VULKEM BLOCK SEALANT
ON ALL JAMB, HEADER, AND
SILL BLOCK PRIOR TO BUCK
INSTALLATION
2'-8"
Attach buck to block wall with
1/4' dia. Elco conc screws with min.
1 1/4" penetration at 12" o.c. max
and 4" max from each corner thru
Exterior face 2" x 6" PT Buck REVIEWED FOR
I wall apes CODE COMPLIANCE
ST. L'UCIE COUNT1
#8 Wood screws thru Jamb into buck
at each hinge and 15" c.c. max and
O e t a l l at Door prior to door attachment
NTS
TYPICAL SECTiON
Scale : 1/2" = 1'-0"
1 lClUl.. I U7Z,/-II- INv I T__v
I. ALL FOOTING ARE DESIGNED FOR A MINIMUM OF 2500 PSF SOIL
BEARING CAPACITY. IF ANY SUB -SOIL, MUCK OR NON -UNIFORM
CONDITIONS EXIST, REPORT TO ARCHITECT AND OBTAIN
PROPER ENGINEERING DATA FOR DESIGN.
2• ALL SLABS AND FOOTINGS TO BE A MINIMUM 2,500 PSi AT 28 DAYS
ALL COLUMNS, FiLLED CELLS, AND BEAMS SHALL BE MIN. 3000 PSI
BE 3000 PSI OR 4.000 PSI GROUT MIX AT 28 DAYS
3. POISON SOIL AND COVER W/ 6 MIL. VISQUEEN WITHIN 24 HOURS. NO
SOIL POISONING TO BE ACCOMPLISHED OUTSIDE OF FOUNDATION.
4 GROUND FLOOR SLAB TO BE A MINIMUM 4" THICK W/ 6X6 10/10
WELDED WiRE MESH REINFORCING ON b MIL. POLYETHYLENE VAPOR
BARRIER ON TERMITE TREATED, CLEAN MACHINE COMPACTED FILL
(MINIMUM 95% DENSITY). LAP POLYETHYLENE 12" MINIMUM. FIBERMESH
MIX MAY BE SUBSTITUTED FOR WELDED WIRE MESH.
5• LOT TO BE CLEARED OF ALL SMALL PLANT GROWTH AND DEBRIS
BEFORE FILL IS BROUGHT iN. FILL MATERIAL SHALL CONSIST OF
CLEAN GRANULAR SAND CONTAINING LESS THAN 10% MATERIAL
PASSING THE US STANDARD NO. 200 MESH SIEVE. PLACE
STRUCTURAL FILL IN LOOSE LAYERS OF 12" IN THICKNESS AND
COMPACT EACH LIFT TO AT LEAST 95% OF ITS MODIFIED DRY
PROCTOR VALUE.
6• GENERAL CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND
DIMENSIONS. BRING ANY DISCREPANCIES OR OMISSIONS TO THE
ATTENTION OF THE ARCHITECT.
GARAGE FLOORS TO BE SMOOTH TROWEL FINISH (SLOPPED PER
FOUNDATION PLAN). PROVIDE 1-1/2" RECESS FOR OVERHEAD DOOR
S. SLOPE ALL PORCH SLABS, COVERED WALK, ETC. AWAY
FROM HOUSE TO DRAINS (IF PROVIDED) PER PLANS
9. DESIGN LOADS ARE AS FOLLOWS:
ROOF (DL+LL) = 41 PSF
WiND VELOCITY = PER PERMIT INFO BOX ON SHEET 41
EXPOSURE ="C"
10. ALL REINFORCING STEEL SHALL BE GRADE 40, MEETING ASTM A-16, 6
A-35 SPECIFICATIONS. ALL ANCHOR TO BE A - 301 STEEL.
Ii• ALL DOWELS, SLEEVES, CONDUITS, INSERTS, BLOCKOUTS, ANCHOR
BOLTS AND FRAMES SHALL BE IN PLACE PRIOR TO POURING CONCRETE.
FOR OPENINGS AND SPECIAL FEATURES OMITTED ON THESE PLANS,
SEE ARCHITECTURAL OR MECHANICAL PLANS WHERE APPLICABLE.
12. MINIMUM CONCRETE PROTECTION FOR REINFORCING BARS:
FOOTING: 3"
BEAMS: 1-1/2"
13. LAP ALL REINFORCING STEEL A MINIMUM OF 48 BAR DIAMETERS.
14. USE STRUCTURAL GRADE WOOD WITH A MINIMUM Fb OF 1600 PSI
15. ALL STANDARD LUMBER SHALL BE SYP WITH A MINIMUM Fb OF 1000
PSI OF NO.2 SOUTHERN PINE, UNLESS NOTED OTHERWISE.
16. ALL LUMBER IN CONTACT WiTH ANY CONCRETE OR MASONRY SHALL BE
PRESSURE TREATED. FASTENERS TO HAVE MIN. G185 RATING.
FOUNDATION
FLAN
I.
Any changes to plans must be submitted to the architect
SCALE: 1/4" = I'-011
for approval before proceedinq with construction.
Termite Protection for New
2.
Contractor shall be responsible
for verification of all
Construction.
notation and dimensions before starting construction.
3.
Soil conditions assumed to be 2500 psf. Should any other conditions be
encountered, the architect shall be notified in writing for revision
Soil treatment used for subterranean termite after prevention
Inside the foundation perimeter shall be done after all
4.
Verify all recess thickness at showers, tile, etc...,
excavation, backfilhng and compaction is complete.
S.
Contractor to provide filled cell with concrete and 1 #5 bar Vert. at 48'I
If soil area is disturbed after initial chemical sail treatment
o.c. max. Provide (1) filled cell on each side of openings up to 5'-II"wide.
shall be retreded with chemical soil treatment
Provide (2) filled cells on each side of openings from 6 -O to of -II„
inframed
and Provide (3) filled cells on each side of openings from 10'-0" and up
Treatment must be in accordance with the rules and laws
Contractor to see plans for any Other condition Used. Foundation walls
established bg the Florida Department of Agriculture and
shall have filled cells at 24" o.c. unless otherwise noted (see section)
consumer services.
6.
Contractor to provide for Form Board Survey - Form Board Survey
Protective sleeves around metallic piping penetrating
to be provided to Truss Company prior to truss construction
concrete slab on grade floors shall not be of cellulose
-1.
Contractor to provide for soil test prior to construction and provide
p P
containing materials and shall receive application of
termicide in annular space between sleeve and pipe.
h t t f view rior to construction
a copy of soil test to arc i ec or I p
8. ALL Reinforcing steel shall be grade 60, meeting ASTM A-16 and
A-35 specifications. ALL Anchors to be A-301 steel.
9. Provide a minimum of 3" concrete protection at footings and
1-1/2" concrete protection at beams for ALL reinforcing bars.
#5 bar vert. w/ E
30" overlap Fill cell with concrete and " " E
at each Pilled c (1) #5 bar vert. (typical). Thicken edge to II _
Max spacing shall not exceed with concrete and 4" concrete slab with flbermesh OR
Wood 48" unless otherwise noted one #5 bar continuous 6"x6" #10/10 WWM on 10 mil Vlsqueen over o Contractor to provide
see foundation plan notes for clean compacted termite treated Pill proper foundation chairs
Base spacing at openings Por proper steel installation
4" GRADE
concrete slab with flbermesh OR
6"x4" II WWM on 6 mil Vlsqueen over
/clean compacted termite treated fill
Grade °p
_III III- III Ili i (III I �i�, -i�,,•
kIIIi��� - �14"w x 18"d Concrete footing
with (2) #5 bar* Cont. and 5
transverse bars at 48" o.c.
F I 1 TYPICAL FOOTING DETAIL
SCALE 1/2" = I'
,4" concrete slab with flbermesh OR
Vxb" #10/10 WWM on 10 mil Vlsqueen over
clean compacted termite treated fill
#5 bar cost.
Step per
foundation plan
Grade
CV
#5 bars Cont. bottom steel
F 12" ' �
DETAIL AT GARAGE STEPDOWN
SCALE 1/2" = I'-
12' x 12" concrete column
block filled with concrete
and (2) VI bars Vert. tied
into lintels above
Top of rooter
16" below finished floor
#5 bar Cont. in
Curb height
=V based on
foundation ulan-
,30"x30"xl6" concrete
column footing with (4)
sty bars each wag
)ETAIL
SCALE 1/2" _
m
30" min.
#5 bar vert. w/
30" overlap Corner Steel Lap
at each Pilled cell
nts
Fill cell with concrete and
(1) #5 bar vart. (typical). Filled Cell Masonry Column With One
Max. spacing shall net exceed ##5 From FootingTo Tie Beam
ood 48" unless otherwise noted
see foundation plan notes for Cone. Fill To Be 3000 PSI
ass spacing at openings See Floor Plan For Location
/ 4" concrete slab with flbermesh OR
111 #10/10 WWM on 6 mil Vlsqueen overL�
/ clean compacted termite treated fill
14"w x laud Concrete footing
-- with 11 #5 bare cont. and #5
transverse bars at 48" c.c.
ARAGE CURB
LE 1/2" =
2" x 6" PT wood secured 'with
1/2"die. x V expansion anchors
with 2" sq. washer at 18" o.c. overhead door track secured to wood
jamb per manufacturer's product approval
Garage Door Jamb Detail
GARAGE DOOR TO WITHSTAND PRESSURES STATED NTCJ
IN PERMIT INFO BOX ON SHEET 41. SEE PRODUCT
APPROVAL FORM FOR MANUFACTURER MAKE AND MODEL.
.09 JLnwa
Single Filled Cell Column
NITS
Filled Cell Masonry Column With One
25 From Footing To Beam Each.
Conc. Fill To Be 3000 PSI
See Floor Plan For Location
Double Filled Cell Column
NTS
1A�,-n„
12" 8'-10" 25'-2"
".' Li ©Q
Q
'r I FI FI I
Rear Patio/Slab I I
to be poured separate
from the house slab. I
I I to
I
LU
I a I IO
O I I
u
UUM
I N I I
o
o
aor o oa I
FI
aN
WN-------� I
f7
I
Rear Patio/Slab to
I be Plush with bottom or I
sliding door recess.
Slope 1/2"
I to
of I
I I
4" concrete slab with flbermesh OR
6"x6" 910/10 WWM on 6 mil Vlsqueen over
M
I clean compacted termite treated fill I
o
I I
"os RC
i r —
'I I ---— —
I sq
I
i l Tankless WH I
l3
A/C
#kl
0ID
H B
O I i mounted above
©I I Id
0
m
o
15 Amp
Meter
i - mw
I £ anal
STACK 111
° ° WASHER( I aij:
Q I DW I r — ❑� AND
IRY@R
IA
I0ovl e-
l IL
a
J I
n
sO t
o
©tu �o� I
lea N oa I I Q q
alFl
I° Az° I I p '� #
FIJu
I I
o
J
FI N in
o —
r—
p p p -77 i C D O O D N O f7 1.5 Recess fot7 a
'Garage
Door
101-01
ei
I
FOOTiNG SCHEDULE
Mark
amDescription
I
14"W x IS"D
MONOLITHIC FOOTING WITH 2 #5 BARS CONTINUOUS
12"W X 124D
MONOLITHIC FOOTING WITH (2) #5 BARS CONTINUOUS
30" x 30" x I6"D
COLUMN FOOTING WITH (4) #5 BARS EACH WAY
8"W x S"D
THICiGEN SLAB EDGE WITH 1 #5 BAR CONTINUOUS
®14"W
x 18"D
With Curb at Garage
MONOLITHIC FOOTING WITH 2 #5 BARS CONTINUOUS - CURB a O'-O"
ROOF SHEETING
ATTACHMENT DETAIL
I. Minimum Nall Size = 8d ring shank (min. 2.5" long)
2. Minimum Screw Size = #8 x 2"
3. Minimum Sheathing Thickness 19/32" COX FII wood
4. Use nails or screws bas d on pressure for roof stated
in permit info box on these plans for zone 3
Ke
Area
Ede
Field
Fastener
Max.
Pressure
Zone 1
6"
6"
8d ring shank
45 psf
Zone 2
6"
8d ring shank
14 psf
Zone 3
q R
4 of8d
ring shank
84 psf
** Zone 3a
4"
6"
48 wood screw
112.5 psf
** Use nails or screws based on pressure for roof stated
in permit info box on these plans for zone 3
Concrete
/ Lintel
Column
Verify with Plan
=0
Vxl Rebar
Rebar 48 Bar Dia.
Min. Overlap
to Lintel Attachment
BEAM SCHEDULE
Mark Size and Descri tion
Two rows of beam block filled with concrete and 1 #5 bar
®1 continuous In each row. Hook vert. bar over top bar with
#5 90e bend bar with a 10' min. lap at top bar.
Provide #5 bars with min. 48 bar
diameters overlap into beam. Tie
filled cell steel Into continuous
beam block steel. %-.,
Provide Cast -Crete T
BU8-OB/OT precast --
[Intel set in mortar _
Min. 8' Staring
-
Provide #5 bar set in pre -cast
lintel into beam where length of
the opening calls for it.
ovide PT Buck
rid he to r janimmb
led call
4' Pre -cast
Sill
R-11 b
Filled Cell
r #5 bare with min. 48 bar
re overlap in filled cell. Tie
all steel into continuous
steel.
Concreteoot F
tag
(see foster schedule
for moot eaes)
DETAIL AT WINDOW OPENING IN
CBS WALL Scale. 1/2" = 1'-0"
SINGLE PLY REAR GIRDER TRUSS
Nall 2' x 4' blockmp to vert. hip of
true nth III x II naih) at 4' ac.
n Install Sompson MGT into awn
5/8' dw. threaded rod set inn. &
\ into wet been and (22) 111 nails into truss
TRUSS BLOCKING DETAIL
AT GIRDER STRAPPING
AT CENTER BEARING POINT
NTS
i/8" thick light textured st cco mst [led per
ASTM C 92(. over ASTM D type 2 papsir backed
wire lath nailed to substrate through one layer of
ASTM D Type 2 felt paper using 8d nails. Substrate
to be 19/32" CDX Plgwood nailed at L o.c. in field
and edges with 1Od ring shank nails into studs.
Gulf Coast Supply and MPG 5v Crimp Metal roofing FL WIL51.12
2i ga. 5v crimp metal roofing attached to plgwood deck using #9 x 1.5'
mood screws with self sealing washer at 12' c.c. max spacing over ASTM D
(tgpe 2) 30 lb felt underlagment installed with min. 4 side laps and V end
I fastened with corrosion resistant tin caps and with 1.25" ring shank nails
apaced L o.c. at all laps and two staggered rows 12" o.c. in field. Attach
deck to trusses using attachment detml-on this sheet
LINTEL SCHEDULE
Mark
WI
Unit r
Idt
Lwitel
sae
Cast -Crete
S @cAcation
Raw of
. .
Abo✓e k
Bettaw
8twi
tap
stssl
MOL
LGoed
(PLPI
Max.
Loomed
fPLF)
MOL
Lend
(PLF)
L22
2'-2'
31-V
slue-OBAT
1
85
3O611
111
1024
L31
;-i8,
4'-0'
811"8-OB/IT
1
s5
266I
1343
163
L45
4'-V
V-1I
OPe-OB/IT
1
85
606
909
334
L50
5'-O'
C-L'
SIR8-09/IT
1
05
On
835
TA
LLO
C-8'
T-A'
GP8-06/IT
I
so
Ion
'121
534
L80
8'-O'
'r-4'
aP"5/2T
I
#5
2
86
152
Ism
512
L10
ar-00
IC'-L'
OP8-I5/2T
1
IB
2
t6
643
530
401
L,OB
T-O'
10'-L'
SPIL-11I
ONE
1
#6
2
s6
533
n83
401
LI00 I
10'-O" 1
I1
OPe-I5/2T
1
03
2
85
682 1
494
452
LIOOB
IO'-O•
11
81'IL-11151 1
ONE
1
1E
2
85
13"
1028
452
L120
12'-O'
13'-4'
GPO-I5/2T
1
85
2
s5
411
428
324
L1208
12'-O'
13'-4'
81'IL-11I
ONE
1
$5
2
#5
1015
TIC
324
L140
II
li'-4'
aFIL-IB/2T
ONE
1
e5
2
85
1290
L01 1
251
LILO
IL'-O'
I7'-4•
aF8-15/2T
1
85
2
85
300
H2
114
LILOS
IL'-0'
11'-4°
SPIL-15/2T
ONE
1
$5
2
•6
160
500
114
- ALL LINTELS SHALL BE MADE BY CAST-CRETE.
- LINTELS SHALL BE FILLED SOLID WITH 3000 PSI CONCRETE
- REFER TO CAST-CRETE CATALOG FOR ALL INFORMATION REGARDING
LINTEL CONSTRUCTION, HANDLING INFORMATION, AND SAFE LOAD REQ.
REQUIREMENTS
- LINTELS OVER 14'-0" LONG ARE TO BE PRESTRESSED.
Simpson HETA 20 or equal
�(IOIve l4trmtif0)
( 24' o.c.) sup orting Max
I810lbs. uplift
Alwanum Drip ---'��
Edge E Fascia /dt3au--
Xil2„
2" x L" Sub-Pasci
Kagcan full o vent virwl soffit installed
umrip 1/8' die Awk x IS" long gale.
roaring nols with 3/8' dm. head per
Oro approval —see chart ehset #1
12' x 12' concrete column
block filled with concrete
and (2) #1 bars vert. tie
into lintels above
thicken edge to 8'x8'
with concrete and -�
one #5 bar continuous
BEYOND
Top of looter
IL" below finished floor
ta
r 12
41
Aluminum Drip -
Edge t Fascia
Flesh and Counter ---
flash
Neil ledger to
gable and truss
with (2) IOd as
at each web
hrnb krth
vsraeal ww
i to proved
raLsei mW
5/8" thick light textured
stucco on typical concrete
block construction
Varies - see plan
#5 bar vert. w/
30" overlap
at each filled cell
Rear Patio/Slab to
be flush with bottom of
sliding door recess.
Trusses at 24" o.c.
re shop drawings bg others
ceding transition i=�
ded using metal studs
arifg exact configuration
no
Batts
batts
Drgwaii ceding
see tgpical section
Nation Detall
nts
Brace Gable end
with 2" x 4' SYP #2
8ft back nailed to bottom
of top chords wing (2) IOd
nails at each truss
`RE-ENGINEEFkED WOOD TRUSSES
e 24"o.c. TYPICAL
( shop drawings bg manufacturer )
\R-30 blown fiberglass
in bottom chord or trusses
I/2' drywall with textured finish
Two rows of beam block filled with concrete
end (U #5 bar cent. in each row. Substitute
precast lintel filled with concrete and (l) #5
bar cunt. for bottom row over openings
1/2" drywall over I" x furring
stripa at IL" o.c. with R4.1 fi—foil
Insulation on tile,
ypical 8" Block wails
All drywall to be installed per FBC R-1O2.3.1
and shall meet all pertaining ASTM codes.
ao Mortar to be Tgpe "M" off proportioned per FBC R4011
and Mortar joints shall comp l; with FBC RLO1.2.1.
Fill cell with concrete and
(1) #5 bar vert. (typical).
Max. spacing whall not exceed
Wood 48" unless otherwise noted
Beam see foundation plan notes for
spacing at openings
' , �� � r e, illll�llllllll ll ll - __ I illl-----IIII II II
I I � IIII ��IIII IIII 'III- li'
�li—III IIII 14. FI
LII I T
Qp ICdI Section at Front Ford
Scale : 1/2" = I'-O"
;%rimidwon t ;RrjtA on 2
1n
Q
H
2
HETA 20 <1ETA 20
I
n
Q
eter
I
ROOF FLAN 0TVIEWED
— OVERHANGS AT 1'-0" UNLESS OTHERWISE NOTED ON THIS SHEET ST. LUCIE COUNT':
— ROOF PITCH AT 4:12 UNLESS OTHERWISE NOTED ON THIS SHEET BQCC
— TRUSS SHOP DRAWINGS TO BE PROVIDED BY MANUFACTURER
— ANY CHANGES TO THIS PLAN SHALL BE SUBMITTED TO THE
ARCHITECT FOR APPROVAL IN WRITING PRIOR TO STARTING CONSTRUCTION.
— ALL TRUSS TO TRUSS CONNECTIONS BY
TRUSS MANUFACTURER
— ARCHITECT TO REVIEW TRUSS SHOP DRAWINGS PRIOR
TO CONSTRUCTION FOR LAYOUT AND UPLIFT VERIFICATION
— CONTRACTOR TO PROVIDE FOR FORM BOARD SURVEY AND TO PROVIDE
FORM BOARD SURVEY TO TRUSS COMPANY PRIOR TO TRUSS CONSTRUCTION
PANEL
"A"
Pokrs
BR
Land
Win
Description
arcs
aro8
Desenptan
Wm
Load
OR
False
1
20
1.2 ke
812
Refngsretor
I
R
a6
12.0 Its
60
2
I
20
1.2 Im
a12
Clothes Washer
3
1
20
1.5 kw
812
Kitchen S.A.C.
6
6
Dr sr
810
5.0 ks
30
2
1
20
1.5 kw
$12
Kitchen S.A.C.
i
e
1
20
-
$12
Bathroom Recspts
4
10
Air C sor
a10
5.0 ks
$0
2
1
20
1.2 ko
all
DoihemMr
II
12
I
20
1.2 ks
aIZ
Microwave
13
14
Mr Ha
$10
6.0 its
30
2
I
Is
-
a14
General Lighting
16
It
I
16
814
Gerwral Lgh"
17
18
WH
a8
1.6 Its
1
15
814
General Lighting
14
20
$201
I
15
-
414
General Lighting
21
22
as
16 kw
1
IS
-
814
Goiwral Lightxq
23
24
spare
26
26
Goo
a12
0.81 K
Spare
2-1
1 28
Spero
Spare
29
1 30
1 opera
PANEL "A" LOAD CALCULATION SHEET
Load Description
at ,
Watts
Total(Watts)
Small, Appliance, CircWt(s) ......... ......... ...........
R4Dg4. ......... ....... .............. .
RePrlgeraior , , , , ,
Microwave ............................................
Dish Washer
Clothpa. Washer .. ............ ........... ..................
Water Heater.
Gera a Door O ,nor
I1109
3
4.821
2
1.500
3.000
1
12 000
12 000
1
1200
1,200
1
1.500
1.500
1
1.200
1 1.200
1
1200
L200
1
5000
5000
1
15,200
15,200
1
810
810
Total Watts
45.931
First 10000 Watts 0100%
1
10.000
10,000
Remainder 35.931 e40%
1
O
14.348
Electric Heat or A/C 10,000 045%
1
10,000
10,000
Calculated Load
Watts
34.314
Voltage
240
Calculated Wattage Divided by Voltage = Total Amps 143.22
Panel Size Required = 150 Amps
Electrical Symbol Le end
$ lannale
Pole Switch
® 11111locessad
Can Light
$+
Double Palo Switch
®
E wbay Recessed
e
Push Button Switch
Exhaust Fan
Duplex Outlet
Calling Mounted Light
Speed Receptacle
♦
WaU Mounted Light
aterpr gr au erreuat
Light with Pull Chairs (attic)
®
Floor Duplex Outlet
©
Computer CornecrLm Jack
®
Carbon Monoxide Detector
4i:�
Flood Light
Thermostat
m
Electrical Panel
®
Central Vac
8
Electrical Meter
®
awake Detector
Caring fan
®
Television Jack
®
Telephone Jade
A � C
A/C Disconnect
®
I x 4 Florescent L ht
®
2 x 4 Florescent Light
®
Speaker Hook -Up
I = JUNCTION BOX TO SUPPORT A FAN
0 se THERMOSTAT LOCATION
B/A = BALANCED AIR
PIRLD VERIFY SERVICE LOCATION RESPECIVE TO PANEL LOCATION AND USE APPROPRIATE RISER BELOW
A/C
(3) ul THHN Copper
2" PVC Schedule -
40 conduit
48110
PANEL
200a rated
meter can
2" PVC ( FPL)-�
schedule 80
2' rigid sarvica FPL
rode
ELECTRICAL RISER
bonding
pant
- Contractor *hall use AL-CU Lending lugs.
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
- Verify AIC/KIC Rating prior to ordering
#2/0 AL SER Cable
With #I Grnd
2" PVC Sc
40 conduit
into attic
200a rated
meter can
2"PVC (FP
schedule 80
2' rigid sarvu
A/rC--di-elc.
LJ 1
IS
MCS
PANEL
bonding
Pant
GEC Bary(t)BL, 8V16aluven,ad
ground rods
_ ALTERNATE SERVICE ELECT.
NTs - Contractor shall use AL-CU Landing lugs.
- Contractor shall torque lugs I.A.W.
manufacturers recommendations which
shall be verified prior to construction
t - Verify AIC/KIC Rating prior to ordering equipm
RISER!
NTs
124 CFM
10314103,111
COVERED
PORCH
DEN
M
STER
B
ROOM
12d
A
14912xLC%1
F�1
\
I \I
�Te
I
124 CFM
I
i I
10xlOxl
I
I
18x4x4
I
14x14
`-
5 CFM
I
8x4x4
12 6%A
GREA-t ROOM
'`'®
°
I
I
C
SET
112 CFM
Cis
112 CFM
IO)dO)dS
I 1a>do
T>
mo
A T I
19 CFM
H
8x4x4
I
8x4x4 PWD
aRE
DINING
I
ROOM
I
Tankless WH
H.B.1
mount48"aa.f.f.
bove
® - 142ttu Access
L.tti ! t
-_= 15PaAmp
° ° P IIou aa tACDW IIll CFM 14 All
oo 3 CFM GARAGE
12ratxl Rf 20x2OS ic4
KITCHEN
1
I
I
1
ceiling - lion L ft u Nb R
I I \\ I
38 CFM
ENTRY 8x4x4_
MECHANIC,4L
r------------------- i
I I
I I
I I
I I
I I
I I
I I
I
LAYOUT
SCALE: 1/4" = 11-011
ELECTRIC NOTES:
I.
Use copper wire only from panel to devices
15.
Contractor shall guarantee all materials and workmanship
20.
All equipment and panel sizes shall be verified before
routings to
2.
Provide and wire a required smoke i Carbon
free of defects for a period of not less than two years from
ordering. The contractor shall provide circuit
Monoxide detectors.
the date of acceptance or certificate of occupancy, or one
suit the job conditions.
3.
Contractor to verify location of electrical
year from closing sale of house.
Correction of defects shall be completed without additional
21.
Furnish and install all fixtures as called for on the plans
4.
service and provider.
ALL bath and kitchen receptacles to be GFCI protected.
charge and shall
include replacements or repair aP any
or as selected by others.
5.
ALL exterior outlets to be WP/GFCI protected.
other phase of installation that may have been damaged.
22.
All raceways and pipes placed in or through any concrete
L.
Recessed cans to be installed per NFPA requirements.
IL.
It is not the intent of these plans to show every minor detail
slab shall be spaced a minimum of three diameters of the
1.
Tamper resistant AFCI receptacles are required in
of construction. The contractor shall furnish and install
all for a complete electrical system and provide all
largest conduit or pipe from any other service.
S.
ALL rooms.
A/C Return Air Balance Must comp)gg w/ FBC RMIL02
items
the requirements necessary for the equipment to be placed in
23.
All exposed wire below 9'-I" shall be installed in metal EMT
9.
A(C RefrigAr�rlt lines that are run Lhru slabs must be
proper working order.
conduit.
a saved in G
IT
All work *hall be done in accordance with the N.E.C. and
10.
ALL A/C Equipment shall comply with energy calculation
shall comply with all local codes and ordinances, and shall
local
24.
Dr er Vents to be installed per
11.
All work shall be performed by a licensed electrical
meet all standard requirements of the electric utility
FByC RM1502
contractor, the completed s stem shall be full g operative.
and telephone company.
12.
Contractor shall pay for all Fees, permits, testin , and
Inspections including blower testing where required.
Ia.
The electrical system shall be completely and effective)g
N.E.C.
13.
All work shall be coordinated with other trades to avoid
grounded as required by the latest edition of the
14.
interference with the progress of construction,
All required insurance shall be provided for protection
19.
All material shall be new and shall bear underwriters
against the public Imbilitg and property damage for the
labels where applicable.
Braden It
Braden AIAe PA
Architects - Planners
411
S.E. Coconut Avenue
Tel
(112) 281-8258
Fax :
(112) 281-8283
E-mail:
bradenaia0comcast.net
5ku
eter
H.B.
H.B.
-a
Wire For
Front Post
Wynne Building Corp.
The Cottage
S anish Lakes
St, Lucie County Florida
Light with
cell
Date Drawn : Revisions
3-2L-20
GARAGE Drawn by:
RIGHT C.C.U.
Checked by:
D.R.B.
Install oulet
under disc.
,&_n�ot shown for
�, clarity
REVIEWED FOR
COPE COMPLIANII
STA LUCIE��`C//++OUNI
BOCC
Sheet Comm #
19-221