Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE �? Q Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE , FL , pp, Permit Number: Owner: WYNNE BUILDING CORP. VQIJI� Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1718.3 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1478.30 ftz b. Frame - Wood, Adjacent R=11.0 . 240.00 ftz , 3. Number of units, if multiple family 1 c. N/A R= ftz 4. Number of Bedrooms 1 d. N/A R= ftz 5. Is this a worst case? Yes 10. Ceiling Types (1336.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1306.00 ftz 6. Conditioned floor area above grade (ftz) 1306 b. Knee Wall (Vented) R=19.0 30.00 ftz Conditioned floor area below grade (ftz) 0 c. N/A R= ftz 11. Ducts R ftz 7. Windows(128:9 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 120 a. U-Factor: Sgl, U=1.02 76.04 ftz SHGC: SH130=0.29 b. U=Factor: Sgl, U=1.03 40.00 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 29.0 SEER:14.00 c. U-Factor: Sgl, U=1.02 12.85 ftz SHGC: SHGC=0.26 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ftz a. Electric Heat Pump 27.0 HSPF:8.20 SHGC: Area Weighted Average Overhang Depth: 4.701 ft. Area Weighted Average SHGC: 0.281 14. Hot water systems a. Electric Tankless Cap: 1 gallons 8. Floor Types (1306.0 sqft.) Insulation Area EF: 0.600 a. Slab -On -Grade Edge Insulation R=0.0 1306.00 ftz 9 b. Conservation features b. N/A R= ftz None c. N/A R= ftz 15. Credits None Glass/Floor Area: 0.099 Total Proposed Modified Loads: 43.81 PASS Total Baseline Loads: 45.95 I hereby certify that the plans and specifications covered by Review of the plans and Id, III this calculation are in compliance with the Florida Energy specifications covered by this Code. ` calculation indicates compliance,,r�' with the Florida Energy Code. rrrr. frr ids ..t3 PREPARED BY: 00 Before construction is completed t x ✓" DATE. 4-28-202 this building will be inspected for compliance with Section 553.908 ��* 7 -AIF 0.. hereby certify that this building, as designed, is in compliance Florida Statutes.. La' with the Florida Energy Code.9'?ti� OWNER/t� BUILDING OFFICIAL: DATE: � DATE: . - Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 5.00 ACRM 4" QED FO R COMPLIANCE �. �L�UCIE COUNTY B GG, C 4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE BUIDLING-THE CO Bedrooms:. 1 Address Type: Street Address Building Type: User Conditioned Area: 1306 Lot # Owner Name: WYNNE BUILDING CORP. Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE BUILDING CORP. Rotate Angle: 180 Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE , Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire.House 1306 10576.2 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID Finished Cooled Heated 1 MASTER BEDROO 234 1895.4 No 0 1 1 Yes Yes Yes 2 DEN 144 1166.4 No 0 1 Yes Yes Yes 3 SINK AREA 42 340.2 No 0 1 Yes Yes Yes 4 CLOSET 63 510.3 No 0 1 No Yes Yes 5 GREAT ROOM 452 3661.2 No 2 1 Yes Yes Yes 6 MASTER BATH 50 405 No 0 1 Yes Yes Yes 7 POWDER 25 202.5 No 0 1 No Yes Yes 8 KITCHEN 232 1879.2 Yes 0 1 Yes Yes Yes 9 LAUNDRY 40 324 No 0 1 No Yes Yes 10 STORAGE 24 192 No 0 0 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 31 ft 0 234 ft2 ____ 0 1 0 2 Slab -On -Grade Edge Insulatio DEN 24 ft 0 144 ft2 0 1 0 3 Slab -On -Grade Edge Insulatio SINK AREA 7 ft 0 42 ft2 ____ 0 1 0 4 Slab -On -Grade Edge Insulatio CLOSET 1 ft 0 63 ft2 ____ 0 1 0 5 Slab -On -Grade Edge Insulatio GREAT ROOM 32 ft 0 452 ft2 ____ 0 1 0 6 Slab -On -Grade Edge Insulatio MASTER BATH 5 ft 0 50 ft2 ___ 0 1 0 7SIab-On-Grade Edge Insulatio POWDER 1 ft 0 25 ft2 ___ 0 1 0 4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017.) Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 8 Slab -On -Grade Edge Insulatio KITCHEN 38 ft 0 232 ft2 --__ 0 1 0 9Slab-On-Grade Edge Insulatio LAUNDRY 1 ft 0 40 ft2 _--_ 0 1 0 10SIab-On-Grade Edge Insulatio STORAGE 21 ft 0 24 ft2 ____ 0 0 1 ROOF / Roof Gable Roof Red Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1376 ft2 0 ft2 Light N 0.6 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1306 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 234 ft2 0.1 Wood 2 Under Attic (Vented) DEN 30 Blown 144 ftz 0.1 Wood 3 Under Attic (Vented) SINK AREA 30 Blown 42 ft2 0.1 Wood 4 Under Attic (Vented) CLOSET 30 Blown 63 ft2 0.1 Wood 5 Under Attic (Vented) GREAT ROOM 30 Blown 452 ft2 0.1 Wood 6 Under Attic (Vented) MASTER BATH 30 Blown 50 ft2 0.1 Wood 7 Under Attic (Vented) POWDER 30 Blown 25 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 232 ft2 0.1 Wood 9 Under Attic (Vented) LAUNDRY 30 Blown 40 ft2 0.1 Wood 10 Under Attic (Vented) STORAGE 30 Blown 24 ft2 0.11 Wood 11 Knee Wall (Vented) GREAT ROOM 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space R-Nhahle Et In Et In Area RAW, le Eraction AhSor' G'rarle% 1 S=>N Exterior Concrete Block - Int InsWASTER BE 4.1 18 0 8 1 145.5 ft2 0 0 0.3 0 2 W=>E Exterior Concrete Block - Int InsWASTER BE 4.1 13 0 8 1 105.1 ft2 0 0 0.3 0 3 N=>S Exterior Concrete Block - Int Insul DEN 4.1 12 0 8 1 97.0 ft2 0 0 0.3 0 4 W=>E Exterior Concrete Block - Int Insul DEN 4.1 12 0 8 1 97.0 ft2 0 0 0.3 0 5 S=>N Exterior Concrete Block - Int InsUBINK AREA 4.1 7 0 8 1 56.6 ft2 0 0 0.3 0 6 N=>S Exterior Concrete Block - Int InsGREAT ROO 4.1 22 0 8 1 177.8 ft2 0 0 .0.3 0 _ 7 W=>E Exterior Concrete Block - Int InsGREAT ROO 4.1 10 0 8 1 80.8 ft2 0 0 0.3 0 8 S=>N Exterior Concrete Block - Int InsWASTER BA 4.1 5 0 8 1 40.4 ft2 0 0 0.3 0 9 N=>S Exterior Concrete Block - Int InsulKITCHEN 4.1 17 0 8 1 137.4 ft2 0 0 0.3 0 10 E=>W Exterior Concrete Block - Int InsuIKITCHEN 4.1 16 0 8 1 129.3 ft2 0 0 0.3 0 11 S=>N Exterior Concrete Block - Int InsulKITCHEN 4.1 5 0 8 1 40.4 ft2 0 0 0.3 0 4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5 FORM R405=2017 INPUT SUMMARYCHECKLIST REPORT WALLS Adjacent it Omf 10 Wall Space Cavity Width Type Height Sheathing Framing Solar- Belo w _12 N=>S Exterior Concrete Block - Int InsulKITCHEN 4.1 35 8 13 N=>S Exterior Concrete Block - Int InsuBTORAGE 4.0999 6 8 _ 14 N=>S Exterior Concrete Block - Int InsuBTORAGE 4.0999 5 8 15 N=>S Garage Frame - Wood MASTER BE 11 30 8 1 282.9 ft2 48.0 ft2 40.0 ft2 0 240.0 ft2 0 0 0 0 0 0.3 0 0.3 0 0.3 0.23 0.3 0 0 0 0 DOORS # Omt Door Type Space Storms U-Value Width Ft In Height Ft In Area 1 E=>W Insulated KITCHEN None .32 3 6 8 20 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. Wall V/ # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Overhang Area Depth Separation Int Shade Screening 1 W=>E 2 Metal 2 W=>E 4 Metal 3 N=>S 6 Metal 4 W=>E 7 Metal 5 S=>N 8 Metal 6 E=>W 10 Metal Low-E Single Yes 1.02 0.29 N Low-E Single Yes 1.02 0.29 N Low-E Single Yes 1.02 0.29 N Low-E Single Yes 1.03 0.27 N Low-E Single Yes 1.02 0.29 N Low-E Single Yes 1.02 0.26 N 32.4 ft2 1 ft 5 in 18.4 ft2 1 ft 5 in 18.4 ft2 1 ft 5 in 40.0 ft2 12 ft 0 in 6.9 ft2 1 ft 5 in 12.8 ft2 1 ft 5 in 1 ft 5 in 1 ft 5 in 1 ft 5 in 1 ft 5 in 1 ft 5 in 1 ft 5 in None None None None None None None None None None None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 280 ft2 280 ft2 35 ft 8.1 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgI-A ACH ACH 50 1 Wholehouse Proposed ACH(50) .000257 881.4 48.38 90.99 .0896 5 HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Singl HSPF:8.2 27 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Singl SEER: 14 29 kBtu/hr cfm 0.8 1 sys#1 4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric Tankless Garage 0.6 1 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cert # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS --- Supply ---- V --- Return --- Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF Heat Cool 1 Attic 6 120 ft. Attic 45 ft2 Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: N Ceiling Fans: Coolin an Feb Heating HJan XFeb Mar Mar Apr APr May MaY Jun Jul Jun Jul Auge Au Sep Oct Oct X Nov Nov [ Dec XDec Ventin Jan [ } Feb Mar [Xl 'Apr [ May [ Jun [ Jul [ Aug [ Se [X] Oct [X} Nov ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 Heating (WEH) AM 68 68 68 68 68 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 68 68 MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 It 0.3 MASTER BEDROO Default(8 Ibs/sq.ft. ft2 It 0.3 DEN Default(8 Ibs/sq.ft. ft2 It 0.3 SINK AREA Default(8 Ibs/sq.ft. ft2 ft 0.3 CLOSET Default(8 Ibs/sq.ft. ft2 ft 0.3 GREAT ROOM Default(8 Ibs/sq.ft. - ft2 It 0.3 MASTER BATH Default(8 Ibs/sq.ft. ft2 It 0.3 POWDER Default(8 Ibs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 LAUNDRY Default 8 Ibs/s .ff 0 ft2 Oft 0.3 STORAGE' 4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP. Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: U Owner: WYNNE BUILDING CORP. Jurisdiction: _ Design Location: FL, Fort Pierce rU COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building "envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed: Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air. barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance'of 12-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope Insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/door jambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including . insulation. maintain permanent contact with the underside of above- . garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac Ds. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed In the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt in shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Pytpncf behind 129p'ng and wiring, Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate -them from the showers and tubs. be insulated. Electrical/phone box or The air barrier shall be. installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the subfloor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. I Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkler cover Mates and waliq or ceilinas, a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400. 4/28/2020 2:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 4 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location .& insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 1 13. Cooling system: Capacity 29.0 a) Split system SEER 14.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEERICOP 6. Conditioned floor area (sq. ft.) 6. 1306 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average), 7a. 0.543 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 27.0 c) Area 7c. 128.9 a) Split system heat pump HSPF 8.2 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE 0 Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.60 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: I d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. . e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec%a B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1061. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 11 b. c) Whole house fan No c) Knee walls/skylight walls 11 c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat No *Label required by Section R303.4.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which.will be installed (or exceeded): in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. Builder Signature: Date: Address of New Home: THE COTTAGE-:;�;� ��� City/FL Zip: FT. PIERCE, FL 72-> 4/28/2020 2:21:49 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1