HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT
Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE �? Q
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE , FL , pp,
Permit Number:
Owner: WYNNE BUILDING CORP. VQIJI�
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (1718.3 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1478.30 ftz
b. Frame - Wood, Adjacent
R=11.0 . 240.00 ftz ,
3. Number of units, if multiple family 1
c. N/A
R= ftz
4. Number of Bedrooms 1
d. N/A
R= ftz
5. Is this a worst case? Yes
10. Ceiling Types (1336.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1306.00 ftz
6. Conditioned floor area above grade (ftz) 1306
b. Knee Wall (Vented)
R=19.0 30.00 ftz
Conditioned floor area below grade (ftz) 0
c. N/A
R= ftz
11. Ducts
R ftz
7. Windows(128:9 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 120
a. U-Factor: Sgl, U=1.02 76.04 ftz
SHGC: SH130=0.29
b. U=Factor: Sgl, U=1.03 40.00 ftz
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
29.0 SEER:14.00
c. U-Factor: Sgl, U=1.02 12.85 ftz
SHGC: SHGC=0.26
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ftz
a. Electric Heat Pump
27.0 HSPF:8.20
SHGC:
Area Weighted Average Overhang Depth: 4.701 ft.
Area Weighted Average SHGC: 0.281
14. Hot water systems
a. Electric Tankless
Cap: 1 gallons
8. Floor Types (1306.0 sqft.) Insulation Area
EF: 0.600
a. Slab -On -Grade Edge Insulation R=0.0 1306.00 ftz
9
b. Conservation features
b. N/A R= ftz
None
c. N/A R= ftz
15. Credits
None
Glass/Floor Area: 0.099 Total Proposed Modified Loads: 43.81
PASS
Total Baseline Loads: 45.95
I hereby certify that the plans and specifications covered by
Review of the plans and
Id, III
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
`
calculation indicates compliance,,r�'
with the Florida Energy Code.
rrrr. frr ids ..t3
PREPARED BY: 00
Before construction is completed
t x ✓"
DATE. 4-28-202
this building will be inspected for
compliance with Section 553.908
��* 7 -AIF
0..
hereby certify that this building, as designed, is in compliance
Florida Statutes..
La'
with the Florida Energy Code.9'?ti�
OWNER/t�
BUILDING OFFICIAL:
DATE: �
DATE: .
- Compliance requires certification by the air handler unit manufacturer that the air handier enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 5.00 ACRM 4" QED FO R
COMPLIANCE �.
�L�UCIE COUNTY
B GG, C
4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE BUIDLING-THE CO Bedrooms:. 1
Address Type:
Street Address
Building Type: User
Conditioned Area: 1306
Lot #
Owner Name: WYNNE BUILDING CORP. Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE BUILDING CORP. Rotate Angle: 180
Street:
THE COTTAGE
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State, Zip:
FT. PIERCE ,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating
Design Daily Temp
Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire.House
1306 10576.2
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
InfilID Finished Cooled
Heated
1 MASTER BEDROO
234 1895.4 No
0
1
1 Yes
Yes
Yes
2 DEN
144 1166.4 No
0
1 Yes
Yes
Yes
3 SINK AREA
42 340.2 No
0
1 Yes
Yes
Yes
4 CLOSET
63 510.3 No
0
1 No
Yes
Yes
5 GREAT ROOM
452 3661.2 No
2
1 Yes
Yes
Yes
6 MASTER BATH
50 405 No
0
1 Yes
Yes
Yes
7 POWDER
25 202.5 No
0
1 No
Yes
Yes
8 KITCHEN
232 1879.2 Yes
0
1 Yes
Yes
Yes
9 LAUNDRY
40 324 No
0
1 No
Yes
Yes
10 STORAGE
24 192 No
0
0
1 Yes
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
MASTER BEDRO 31 ft 0
234 ft2
____
0 1
0
2 Slab -On -Grade Edge Insulatio
DEN 24 ft 0
144 ft2
0 1
0
3 Slab -On -Grade Edge Insulatio
SINK AREA 7 ft 0
42 ft2
____
0 1
0
4 Slab -On -Grade Edge Insulatio
CLOSET 1 ft 0
63 ft2
____
0 1
0
5 Slab -On -Grade Edge Insulatio
GREAT ROOM 32 ft 0
452 ft2
____
0 1
0
6 Slab -On -Grade Edge Insulatio
MASTER BATH 5 ft 0
50 ft2
___
0 1
0
7SIab-On-Grade Edge Insulatio
POWDER 1 ft 0
25 ft2
___
0 1
0
4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017.) Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
8 Slab -On -Grade Edge Insulatio KITCHEN 38 ft 0
232 ft2
--__
0
1
0
9Slab-On-Grade Edge Insulatio LAUNDRY 1 ft
0
40 ft2
_--_
0
1
0
10SIab-On-Grade Edge Insulatio STORAGE 21 ft 0
24 ft2
____
0
0
1
ROOF
/
Roof
Gable
Roof
Red
Solar
SA Emitt
Emitt Deck
Pitch
V
#
Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1
Hip Metal 1376 ft2
0 ft2
Light
N
0.6
No 0.9
No 0
18.4
ATTIC
V
#
Type Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1
Full attic Vented
150
1306 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1
Under Attic (Vented) MASTER BEDRO
30
Blown
234 ft2
0.1
Wood
2
Under Attic (Vented) DEN
30
Blown
144 ftz
0.1
Wood
3
Under Attic (Vented) SINK AREA
30
Blown
42 ft2
0.1
Wood
4
Under Attic (Vented) CLOSET
30
Blown
63 ft2
0.1
Wood
5
Under Attic (Vented) GREAT ROOM
30
Blown
452 ft2
0.1
Wood
6
Under Attic (Vented) MASTER BATH
30
Blown
50 ft2
0.1
Wood
7
Under Attic (Vented) POWDER
30
Blown
25 ft2
0.1
Wood
8
Under Attic (Vented) KITCHEN
30
Blown
232 ft2
0.1
Wood
9
Under Attic (Vented) LAUNDRY
30
Blown
40 ft2
0.1
Wood
10
Under Attic (Vented) STORAGE
30
Blown
24 ft2
0.11
Wood
11
Knee Wall (Vented) GREAT ROOM
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent Cavity Width
Height
Sheathing Framing Solar
Below
Space R-Nhahle
Et In
Et
In
Area
RAW, le Eraction
AhSor' G'rarle%
1
S=>N
Exterior Concrete Block - Int InsWASTER BE
4.1 18
0 8
1
145.5 ft2
0
0
0.3
0
2
W=>E
Exterior Concrete Block - Int InsWASTER BE
4.1 13
0 8
1
105.1 ft2
0
0
0.3
0
3
N=>S
Exterior Concrete Block - Int Insul DEN
4.1 12
0 8
1
97.0 ft2
0
0
0.3
0
4
W=>E
Exterior Concrete Block - Int Insul DEN
4.1 12
0 8
1
97.0 ft2
0
0
0.3
0
5
S=>N
Exterior Concrete Block - Int InsUBINK AREA
4.1 7
0 8
1
56.6 ft2
0
0
0.3
0
6
N=>S
Exterior Concrete Block - Int InsGREAT ROO
4.1 22
0 8
1
177.8 ft2
0
0
.0.3
0
_ 7
W=>E
Exterior Concrete Block - Int InsGREAT ROO
4.1 10
0 8
1
80.8 ft2
0
0
0.3
0
8
S=>N
Exterior Concrete Block - Int InsWASTER BA
4.1 5
0 8
1
40.4 ft2
0
0
0.3
0
9
N=>S
Exterior Concrete Block - Int InsulKITCHEN
4.1 17
0 8
1
137.4 ft2
0
0
0.3
0
10
E=>W
Exterior Concrete Block - Int InsuIKITCHEN
4.1 16
0 8
1
129.3 ft2
0
0
0.3
0
11
S=>N
Exterior Concrete Block - Int InsulKITCHEN
4.1 5
0 8
1
40.4 ft2
0
0
0.3
0
4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 5
FORM R405=2017 INPUT SUMMARYCHECKLIST REPORT
WALLS
Adjacent
it Omf 10 Wall
Space Cavity Width
Type
Height
Sheathing Framing Solar- Belo w
_12 N=>S Exterior Concrete Block - Int InsulKITCHEN 4.1 35 8
13 N=>S Exterior Concrete Block - Int InsuBTORAGE 4.0999 6 8
_ 14 N=>S Exterior Concrete Block - Int InsuBTORAGE 4.0999 5 8
15 N=>S Garage Frame - Wood MASTER BE 11 30 8
1 282.9 ft2
48.0 ft2
40.0 ft2
0 240.0 ft2
0
0
0
0
0 0.3
0 0.3
0 0.3
0.23 0.3
0
0
0
0
DOORS
# Omt
Door Type Space Storms
U-Value Width
Ft In
Height
Ft In
Area
1 E=>W
Insulated KITCHEN None
.32 3
6 8
20 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
Wall
V/ # Ornt ID Frame
Panes NFRC U-Factor SHGC Imp
Overhang
Area Depth Separation Int Shade
Screening
1 W=>E 2 Metal
2 W=>E 4 Metal
3 N=>S 6 Metal
4 W=>E 7 Metal
5 S=>N 8 Metal
6 E=>W 10 Metal
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.03 0.27 N
Low-E Single Yes 1.02 0.29 N
Low-E Single Yes 1.02 0.26 N
32.4 ft2 1 ft 5 in
18.4 ft2 1 ft 5 in
18.4 ft2 1 ft 5 in
40.0 ft2 12 ft 0 in
6.9 ft2 1 ft 5 in
12.8 ft2 1 ft 5 in
1 ft 5 in
1 ft 5 in
1 ft 5 in
1 ft 5 in
1 ft 5 in
1 ft 5 in
None
None
None
None
None
None
None
None
None
None
None
None
GARAGE
# Floor Area
Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 280 ft2
280 ft2 35 ft
8.1 ft
11
INFILTRATION
# Scope Method
SLA CFM 50 ELA EgI-A ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000257 881.4 48.38 90.99 .0896
5
HEATING SYSTEM
# System Type
Subtype Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/ Split Singl HSPF:8.2
27 kBtulhr
1
sys#1
COOLING SYSTEM
# System Type
Subtype Subtype Efficiency
Capacity Air Flow
SHR Block
Ducts
1 Central Unit/
Split Singl SEER: 14
29 kBtu/hr
cfm
0.8 1
sys#1
4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type
SubType
Location
EF
Cap
Use
SetPnt
Conservation
1 Electric
Tankless
Garage
0.6
1 gal
60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # Company Name
System
Model # Collector Model
# Area Volume
FEF
None None
ft2
DUCTS
--- Supply ----
V
--- Return ---
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area
Leakage Type
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic
6 120 ft.
Attic
45 ft2
Default Leakage
Attic
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: N
Ceiling Fans:
Coolin an Feb
Heating HJan XFeb
Mar
Mar
Apr
APr
May
MaY
Jun Jul
Jun Jul
Auge
Au
Sep
Oct
Oct X
Nov
Nov
[ Dec
XDec
Ventin Jan [ } Feb
Mar
[Xl 'Apr [
May
[ Jun [ Jul
[ Aug
[ Se
[X] Oct [X}
Nov
] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4
5 6
7
8
9 10
11
12
Cooling (WD) AM
78
78 78
78
78 78
78
78
78 78
78
78
PM
78
78 78
78
78 78
78
78
78 78
78
78
Cooling (WEH) AM
78
78 78
78
78 78
78
78
78 78
78
78
PM
78
78 78
78
78 78
78
78
78 78
78
78
Heating (WD) AM
68
68 68
68
68 68
68
68
68 68
68
68
PM
68
68 68
68
68 68
68
68
68 68
68
68
Heating (WEH) AM
68
68 68
68
68 68
68
68
68 68
68
68
PM
68
68 68
68
68 68
68
68
68 68
68
68
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 It
0.3
MASTER BEDROO
Default(8 Ibs/sq.ft.
ft2
It
0.3
DEN
Default(8 Ibs/sq.ft.
ft2
It
0.3
SINK AREA
Default(8 Ibs/sq.ft.
ft2
ft
0.3
CLOSET
Default(8 Ibs/sq.ft.
ft2
ft
0.3
GREAT ROOM
Default(8 Ibs/sq.ft. -
ft2
It
0.3
MASTER BATH
Default(8 Ibs/sq.ft.
ft2
It
0.3
POWDER
Default(8 Ibs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUNDRY
Default 8 Ibs/s .ff
0 ft2
Oft
0.3
STORAGE'
4/28/2020 2:17 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE BUIDLING-THE COTTAGE IMPACT Builder Name: WYNNE BUILDING CORP.
Street: THE COTTAGE Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
U
Owner: WYNNE BUILDING CORP. Jurisdiction:
_
Design Location: FL, Fort Pierce
rU
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building "envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed:
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air. barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance'of 12-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope Insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including .
insulation.
maintain permanent contact with the underside of
above-
. garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
Ds.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed In the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt in shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Pytpncf behind 129p'ng and wiring,
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate -them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be. installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the subfloor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be used to fill voids
between fire sprinkler cover Mates and waliq or ceilinas,
a. In addition, inspection of log walls shall be in accordance with the provisions of [CC-400.
4/28/2020 2:18 PM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location .& insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
1
13. Cooling system: Capacity
29.0
a) Split system SEER
14.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source SEERICOP
6. Conditioned floor area (sq. ft.)
6.
1306
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average),
7a.
0.543
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
27.0
c) Area
7c.
128.9
a) Split system heat pump HSPF
8.2
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.60
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior: I
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%a
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1061.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11 b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
No
*Label required by Section R303.4.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which.will be installed (or exceeded): in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature: Date:
Address of New Home: THE COTTAGE-:;�;� ��� City/FL Zip: FT. PIERCE, FL 72->
4/28/2020 2:21:49 PM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1