HomeMy WebLinkAboutEnergy CodeFORM R405-2017
FLORIDA ENERGY'EFFICIENCY CODE I°OR BUILMNG CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
ProjectName: YNNE THE WINDSOR IMPACT
Street: v,�C% Q�zN\,2i-o_
BuilderName: WYNNE DEVELOPMENT
Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL,
PermitNumber:
Owner:
Jurisdiction:
DesignLocation: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types ,(1432.0 sgft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 1224.00 ft2
b. Frame -Wood, Adjacent
R=11.0 208:00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d• N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1783.0. sqft.)
Insulation Area
a. UnderAttic (Vented)
R=30.0 1753.06 ft2
6. Conditioned floorarea above grade (ft2) 1753
b. Knee Wall (Vented)
R=19.0 30.00 ft2
Conditioned floor area belowgrade(ft2) 0
c.
R= ft2
11. Ducts
R ft2
7. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 175
a. U-Factor: Sgl, U=1.04. 111.36 ft2
SHGC: SHGC=0.29
b. U-Factor: Sgl, U=1.11 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.27
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.285
14. Hotwatersystems
a. Electric
Cap: 50 gallons
8. Floor Types (1753.0 sqft.) Insulation Area
EF: 0.970
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.17
PASS
Total Baseline Loads: 53.92
I hereby certify that the plans and specifications covered by
Review of the plans and
" m
this calculation are in compliance with the Florida Energy
specifications covered by this
Code.
calculation indicates compliance+
with the Florida Energy Code.
PREPARI=D 13Y; _ -
DATE:
Before construction is completed
this building ,will be inspected for
compliance with Section 553.908
q "
_
I .hereb certi that this building, as designed,. is in compliance
Y fY 9, 9 P
Florida Statutes.
with the Florida Energy CodeW'^r''°1
OWNER/A E •
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by.the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed- in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection. Checklist in accordance with R402.4.1.1 and this project requires
an envelope leakage test report with. envelope leakage no greater than 5-.00 ACH50 (R402.4:1.2).
4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software P Page 1 of 6
FORM R405-2017 INPUT -SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP Bedrooms: 3
Address Type:
Street Address
Building Type: User ConditionedArea: 1753
Lot#
OwnerName: Total Stories: 1
Block/Subdivision:
# of Units: 1 Worst Case: Yes
PlatBook:
BuilderName: WYNNE DEVELOPMENT RotateAngle: 0
Street:
Permit Office: ST. LUCIE COUNTY CrossVentilation: No
County:
St. Lucie
Jurisdiction: Whole House Fan: No
City, State, Zip:
FT. PIERCE,
FamilyType: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/ Design Temp
Int Design Temp
Heating
Design DailyTemp
V DesignLocation TMYSite 97.5 %
2.5 %
Winter -
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area Volume
1 Entire House 1753 14024
SPACES
Number Name Area. Volume Kitchen Occupants
Bedrooms
InfilID
Finished Cooled
Heated
1 MASTER BEDROO 224 1792 No
0
1
1
Yes
Yes
Yes
2 WIC 63 504 No
0
1
No
Yes
Yes
3 MASTER BATH 56 448 No
0
1.
Yes
Yes
Yes
4 M.BATH 61 488 No
0
1
Yes
Yes
Yes
5 LAUDRY 36 288 No
0
1
No
Yes
Yes
6 BEDROOM 2 180 1440 No
0'
1
1
Yes
Yes `
Yes
7 DINING/GREAT RO 588 4704 No
2
1
Yes
Yes
Yes
8 KITCHEN 209 1672 Yes
0
1
Yes
Yes
Yes
9 BATH 50 400 No
0
1
Yes
Yes
Yes
10 HALL 25 200 No
0
1
No
Yes
Yes
11 FOYER 92 736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3 169 1352 No
0
1
1
Yes
Yes
Yes
FLOORS
\77# FloorType Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulation MASTER BEDRO 37 ft 0
224 ft2
----
0 1
0
2Slab-On-Grade Edge Insulation WIC 1 ft 0
63ft2
----
0 1
0
3 Slab -On -Grade Edge Insulation MASTER BATH 8 ft 0
56 ft2
_---
0 1
0
4Slab-On-Grade Edge Insulation M. BATH 7 ft 0
61 ft2
----
0 1
0
5Slab-On-Grade Edge Insulation LAUDRY 1 ft 0
36ft2
----
0 1
0
4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# FloorType
Space Perimeter PerimeterR-Value
Area
JoistR-Value
Tile Wood Carpet
6 Slab -On -Grade Edge Insulation
BEDROOM 2 12 ft
0
180 ft2
____
0
1
0
7Slab-On-Grade Edge Insulation
DINING/GREAT 50ft
0
588ft2
_--_
0
1
0
8Slab-On-Grade Edge Insulation
KITCHEN 11 ft
0
209ft2
____
0
1
0
9 Slab -On -Grade Edge Insulation
BATH 5 ft
0
50 W
----
0
1
0
10SIab-On-Grade Edge Insulation
HALL 1 ft
0
25ft2
_---
0
1
0
11SIab-On-Grade Edge Insulation
FOYER 9 ft
0
92 ft2
_---
0
1
0
12SIab-On-Grade Edge Insulation
BEDROOM 3 14 ft
0
169 ft2
-_--
0
1
0
ROOF
/
Roof
Gable
Roof
Rad
Solar
SA Emitt
Emitt Deck
Pitch
# Type Materials Area
Area
Color
Barr
Absor.
Tested
Tested Insul.
(deg)
1 Hip
Metal 1847 ft2
0 ft2
Light
N
0.4
No 0.9
No 0
18.4
ATTIC
V # Type
Ventilation
Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# CeilingType
Space
R-Value
Ins Type
Area
Framing Frac
Truss Type
1 UnderAttic (Vented)
MASTER BEDRO
30
Blown
224 ft2
0.1
Wood
2 UnderAttic (Vented)
WIC
30
Blown
63ft2
0.1
Wood
3 UnderAttic (Vented)
MASTER BATH
30,
Blown
56 ft2
0.1
Wood
4 UnderAttic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 UnderAttic(Vented)
LAUDRY
30
Blown
36ft2
0.1
Wood
6 UnderAttic (Vented)
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 UnderAttic (Vented)
DINING/GREAT
30
Blown
588ft2
0.1
Wood
8 UnderAttic(Vented)
KITCHEN
30
Blown
209ft2
0.1
Wood
9 UnderAttic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
10 UnderAttic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 UnderAttic(Vented)
FOYER
30
Blown
92ft2
0.1
Wood
12 UnderAttic(Vented)
BEDROOM
30
Blown
169ft2
0.1
Wood
13 Knee Wall (Vented)
DINING/GREAT
19
Blown
30 ft2
0.11
Wood
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Belo
SpaceRA/allie
n Et
n
Area
on qnr1
w
E Exterior Concrete Block - Int InsuMASTER BE
4.1 16
0 8
0
128.0 ft2
0
0
0.3
0
2 W Exterior Concrete Block- Int InsuMASTER BE
4.1 7
0 8
0
56.0 ft2
0
0
0.3
0
3 S Exterior Concrete Block - Int InsuMASTER BE
4.1 14
0 8
0
112.0 ft2
0
0
0.3
0
4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMfiflARY CHFCKLIST RFP.ORT
WALLS
5E
Adjacent Space
Cavity Width
Et In
Height
Et In
Area
Sheathing Framing
R-4/aille Fraction
Solar
Ahqor
Below
rrarJP%
4
E
Exterior
Concrete Block - Int InsuMASTER BA
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
_ 5
E
Exterior
Concrete Block - Int Insul M. BATH
4.1 7
0
8 0
56.0 ft2
0
0
0.3
0
6
E
Exterior
Concrete Block- Int InsuBEDROOM 2
4.1 12
0
8 0
96.0 ft2
0
0
0.3
0
_ 7
S
Exterior
Concrete.Block- IntlnsuDINING/GRE
4.1 30
0
8 0
240.0ft2
0
0
0.3
0
8
W
Exterior
Concrete. Block - IntlnsuDINING/GRE
4.1 20
0
8 0
160.0ft2
0
0
0.3
0
9
W
Exterior
Concrete Block - Int Insul KITCHEN
4.1 11
0
8 0
88.0 ft2
0
0
0.3
0
10
E
Exterior
Concrete Block - Int Insul BATH
4.1 5
0
8 0
40.0 ft2
0
0
0.3
0
11
N
Exterior
Concrete Block- Int Insul FOYER
4.1 8
0
8 0
64.0 ft2
0
0
0.3
0
12
N
Exterior
Concrete Block- Int Insul FOYER
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
_ 13
W
Exterior
Concrete Block- Int InsuBEDROOM 3
4.1 13
0
8 0
104.0 ft2
0
0
0.3
0
14
N
Exterior
Concrete Block- Int InsuBEDROOM 3
4.1 1
0
8 0
8.0 ft2
0
0
0.3
0
15
N
Garage
Frame -Wood BEDROOM
11 26
8
208.0ft2
0.23
0.3
0
DOORS
#
Omt
DoorType Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Insulated FOYER
None
.32
3
3
6 8
21.7 ft2
WINDOWS
Orientation shown is the entered orientation => changed to Worst Case.
/
Wall
Overhang
Ornt ID
Frame Panes NFRC U-Factor SHGC
Imp
Area
Depth
Separation
IntShade
Screening
1
'S 3
Metal Low-ESingle Yes
1.04 0.29
N
32.4ft2
.1 ft 0 in
1 ft 5 in
Drapes/blinds
Exterior5
2
E 5
Metal Low-ESingle. Yes
1.04 0:29
N
6:9 ft2
1 ft 0 in
1 ft 5 in
None
None
3
E 6
Metal Low-ESingle Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 ft 5 in
None
None
4
S 7
Metal Low-ESingle Yes
1.04 0.29
N
39.8 ft2
1 ft 0 in
1 ft 5 in
None
None
5
W 8
Metal Low-ESingle Yes
1.11 0.27
N
40.0 ft2
8 ft 0 in
1 ft 5 in
None
None
6
W 13
Metal Low-ESingle Yes
1.04 0.29
N
16.2 ft2
1 ft 0 in
1 It 5 in
Drapes/blinds
Exteriors
GARAGE
#
FloorArea CeilingArea Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
806 ft2 806 ft2
26 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgLA
ACH
ACH 50
1 Wholehouse ProposedACH(50) .000254 1168.7 64.16
120.66
.0881
5
4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
# System Type
Subtype
Speed Efficiency
Capacity
Block
Ducts
1 Electric Heat Pump/
Split
Single HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
# System Type
Subtype
Subtype Efficiency
Capacity
Air Flow SHR Block
Ducts
1 CentralUnit/
Split
Single SEER:15
34.8 kBtu/hr
cfm 0.85 1
sys#1
HOT WATER SYSTEM
# . System Type SubType
Location
EF Cap
Use
SetPnt
Conservation
1 Electric None
Garage
0.97 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector Storage
Cert # CompanyName
System Model# CollectorModel#
Area Volume
FEF
None None
ft2
DUCTS
/ ---- Supply—
--- Return ----
Air
CFM 25
CFM25
HVAC #
# Location R-Value Area
Location
Area LeakageType
Handler
TOT
OUT QN RLF
Heat Cool
1 Attic 6 175 ft2
Attic
55 ft2 DefaultLeakage
Attic
(Default) c(Default) c
1 1
TEMPERATURES
ProgramableThermostat: Y
Ceiling Fans:
CoolingJan Feb Mar
HeatinJan Feb Mar
Apr
f Apr
Ma Jun Jul
May]) Jun Jul
I
Auge
f[ AuSeP
Oct Nov
Octj Nov
Dec
DecVentin
Jan Feb Mar
[X] A r
May ] Jun [ Jul
[ Aug
Se
[X] Oct [X] Nov
Dec'
ThermostatSchedule: HERS 2006 Reference
Hours
ScheduleType 1
2 3
4 5 6
7
8
9 10 11
12
Cooling(WD) AM 78
78 78
78 78 78
78
78
80 80 80
80
PM 80
80 78
78 78 78
78
78
78 78 78
78
Cooling(WEH) AM 78
78 78
78 78 78
78
78
78 78 78
78
PM 78
78 78
78 78 78
78
78
78 78 78
78
Heating (WD) AM 66
66 66
66 66 68
68
68
68 68 68
68
PM 68
68 68
68 68 68
68
68
68 68 66
66
Heating (WEH) AM 66
66 66
66 66 68
68
68
68 68 68
68
PM 68
68 68
68 68 68
68
68
68 68 66
66
MASS
Mass Type
Area
Thickness Furniture Fractio n
Space
Default(8.lbs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(81bs/sq.ft.
ft2
ft
0.3
WIC
Default(81bs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(81bs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(81bs/sq.ft.
ft2
ft
0.3
BEDROOM 2
Default(8lbs/sq.ft.
ft2
ft
0.3
DINING/GREAT RO
Default(8lbs/sq.ft.
ft2
ft
0.3
KITCHEN
4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area Thickness Furniture Fraction
Space
Default(8lbs/sq.ft.
ft2 ft 0.3
BATH
Default(8lbs/sq.ft.
ft2 ft 0.3
HALL
Default(8lbs/sq.ft.
ft2 ft 0.3
FOYER
Default 8lbs/s .ft.
W ft 0.3
BEDROOM.3
4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Owner: Jurisdiction:
.09
W
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous. air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed,
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top. plate and the top of exterior walls shall be
shall be insulated by completely filling the.cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope.insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/door jambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing: cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking,or floor framing cavity
g insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.'
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spat
as.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pupung and wiring.
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box. or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
.be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
I
Caulking or other adhesive sealants shall not be.used to fill voids
between fire sprinkler rover plates and wall- or ceolings.
a. In addition, inspection of Iog:walls shall be in accordance with the provisions of ICC-400,
4/21/2020 10:05 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL .(EPL). DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 9.7
The lower, the Energy. Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location.& insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location
Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
34.8
a) Split system SEER
15:0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package SEER
c) Ground/water source.SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1753
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) Ll4actor:(weighted average)
7a.
1.058
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.285
14. Heating system: Capacity
34.8
c) Area
7c.
151.4
a) Split system heat pump HSPF
8.5
b) Single.package heat pump HSPF
8. Skylights
c) Electric resistance COP
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor -type, insulation level:
a) Slab' -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
_
15. Water heating system
c) Concrete, raised (R-value)
9c.
_
a) Electric resistance EF
0.97
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10131.
11.0
2. Masonry (Insulation R=value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a). Ceiling fans
a) Under attic
11 a.
30.0
b). Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11 c.
19.0
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded):in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:_ Date:
Address:of New Home: ' ' \ City/FL Zip: FT. PIERCE. FL JI-ky
4/21/2020 10:05:25 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1