Loading...
HomeMy WebLinkAboutEnergy CodeFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE F®R SMUNG CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method ProjectName: WYNNE THE WI DSOR IMPACT Street: 4�; &Iz v S BuilderName: WYNNE DEVELOPMENT Permit Office: ST. LUCIE COUNTY City, State, Zip: Fr. PIERCE, FL, PermitNumber: Owner: Jurisdiction: Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types .(1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 1224.00 ft2 b. Frame- Wood, Adjacent R=11.0 208:00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1783.0. sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floorarea above grade (ft2) 1753 b. Knee Wall (Vented) R=19.0 30.00 ft2 Conditioned floorareabelowgrade(ft2) 0 c. N/A R= ft2 11. Ducts R ft2 7. Windows(151 A sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 175 a. U-Factor: Sgl, U=1.04 111.36 ft2 SHGC: SHGC=0.29 b. U-Factor: Sgl, U=1.11 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.27 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating;systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.285 14. Hot water systems 8. Floor Types (1753.0 sqft.).) Insulation Area a. Electric Cap: 50 gallonsEF:0.970 a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.17 fig -sA�Set Total Baseline Loads: 53.92 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this , Code. calculation indicates compliance ..: \ with the Florida Energy Code l/ Ui�v Ckti%- 1V� PREPARp RY' DATE: Before construction is completed. this building will be inspected for compliance with Section 553.908 I .hereby certify.that this building, as designed, is in compliance Florida Statutes. �y with the Florida Energy Code.�j~ OWNER/AG fIT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handier unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this projec'kequires an envelope leakage test report with envelope leakage no greater than 5.00 ACH50, (R402.4.1.2). ON 4/21/2020 10:04 AM EnergyG.auge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP Bedrooms: 3 Address Type: Street Address Building Type: User ConditionedArea: 1753 Lot# OwnerName: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes P.IatBook: BuilderName: WYNNE DEVELOPMENT RotateAngle: 0 Street: Permit Office: ST. LUCIE COUNTY CrossVentilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, FamilyType: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design DailyTemp V DesignLocation TMYSite 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfilID. Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1. Yes Yes Yes 4 M.BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0' 1 1 Yes Yes ` Yes 7 DINING/GREAT RO 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 ' 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulation MASTER BEDRO 37 ft 0 224 ft2 ____ 0 1 0 2Slab-On-Grade Edge Insulation WIC 1 ft 0 63ft2 ____ 0 1 0 3 Slab -On -Grade Edge Insulation MASTER BATH 8 ft 0 56 ft2 __ 0 1 0 4Slab-On-Grade Edge Insulation M. BATH 7ft 0 61 ft2 ---- 0 1 0 5Slab-On-Grade Edge Insulation LAUDRY 1 ft 0 36ft2 _-_- 0 1 0 4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # FloorType Space Perimeter PerimeterR-Value Area JoistR Value Tile Wood Carpet 6 Slab -On -Grade Edge Insulation BEDROOM 2 12 It 0 180 W __-- 0 1 0 7Slab-On-Grade Edge Insulation DINING/GREAT 50ft 0 588ft2 ---- 0 1 0 8Slab-On-Grade Edge Insulation KITCHEN 11 ft 0 209ft2 ---- 0 1 0 9 Slab -On -Grade Edge Insulation BATH 5 ft 0 50 ft2 _--- 0 1 0 10SIab-On-Grade Edge Insulation HALL 1 ft 0 25ft2 ---- 0 1 0 11SIab-On-Grade Edge Insulation FOYER 9 ft 0 92 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulation BEDROOM 3 14 ft 0 169 ft2 __-- 0 1 0 ROOF / Roof Gable Roof Rad Solar SA Emitt Emitt Deck Pitch # Type Materials Area Area Color Barr Absor. Tested Tested Insul. (deg) 1 Hip Metal 1847 ft2 0 ft2 Light N 0.4 No 0.9 No 0 18.4 ATTIC V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 UnderAttic(Vented) MASTER BEDRO 30 Blown 224 ft2 0.1 Wood 2 Under Attic WIC 30 Blown 63ft2 0.1 Wood 3 UnderAttic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 UnderAttic(Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 UnderAttic (Vented) LAUDRY 30 Blown 36 ft2 0.1 Wood 6 UnderAttic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 UnderAttic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 UnderAttic(Vented) KITCHEN 30 Blown 209ft2 0.1 Wood 9 UnderAttic(Vented) BATH 30 Blown 50ft2 0.1 Wood 10 UnderAttic(Vented) HALL 30 Blown 25ft2 0.1 Wood 11 UnderAttic(Vented) FOYER 30 Blown 92ft2 0.1 Wood 12 UnderAttic (Vented) BEDROOM 30 Blown 169ft2 0.1 Wood 13 Knee Wall (Vented) DINING/GREAT 19 Blown 30 ft2 0.11 Wood WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below Space 1 E Exterior Concrete Block - Int InsuMASTER BE 4.1 16 0 8 0 128.0.ft2 0 0 0.3 0 2 W Exterior Concrete Block- Int InsuMASTER BE 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 3 S Exterior Concrete Block- Int InsuMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.3 0 4/21/2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Spacele Cavity Width Ft Height n Area Sheathing Framing ue on Solar Below Ahqorrrn 4 E Exterior Concrete Block - Int InsuMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 5 E Exterior Concrete Block - Int Insul M. BATH 4.1 7 0 8 0 56.0 ft2 0 0 0.3 0 6 E Exterior Concrete Block- Int InsuBEDROOM 2 4.1 12 0 8 0 96.0 ft2 0 0 0.3 0 7 S Exterior Concrete.Block- IntlnsuDINING/GRE 4.1 30 0 8 0 240.0ft2 0 0 0.3 0 8 W Exterior Concrete Block- Int InsuDINING/GRE 4.1 20 0 8 0 160.0 ft2 0 0 0.3 0 9 W Exterior Concrete Block- Int Insul KITCHEN 4.1 11 0 8 0 88.0 ft2 0 0 0.3 0 10 E Exterior Concrete Block - Int Insul BATH 4.1 5 0 8 0 40.0 ft2 0 0 0.3 0 _ 11 N Exterior Concrete Block- Int Insul FOYER 4.1 8 0 8 0 64.0 ft2 0 0 0.3 0 _ 12 N Exterior Concrete Block- Int Insul FOYER 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 13 W Exterior Concrete Block - Int InsuBEDROOM 3 4.1 13 0 8 0 104.0 ft2 0 0 0.3 0 14 N Exterior Concrete Block - Int InsuBEDROOM 3 4.1 1 0 8 0 8.0 ft2 0 0 0.3 0 _15 N Garage Frame -Wood BEDROOM 11 26 8 208.0ft2 0.23 0.3 0 DOORS # Ornt DoorType Space Storms U-Value Width Height Area Ft In Ft In 1 N Insulated FOYER None .32 3 3 6 8 21.7 ft2 WINDOWS Orientation shown is the entered orientation => changed to Worst Case. V Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation IntShade Screening 1 S 3 Metal Low-ESingle Yes 1.04 0.29 N 32.4 ft2 1 ft 0 in 1 ft5 in Drapes/blinds Exterior5 2 E 5 Metal Low-ESingle Yes 1.04 0.29 N 6.9 ft2 1 ft 0 in 1 ft5 in None None 3 E 6 Metal Low-ESingle Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft5 in None None 4 S 7 Metal Low-ESingle Yes 1.04 0.29 N 39.8 ft2 1 ft 0 in 1 ft 5 in None None 5 W 8 Metal Low-ESingle Yes 1.11 0.27 N 40.0 ft2 8 ft 0 in 1 ft5 in None None 6 W 13 Metal Low-ESingle Yes 1.04 0.29 N 16.2 ft2 1 ft 0 in 1 ft 5 in Drapes/blinds Exterior5 GARAGE # FloorArea CeilingArea Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft2 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse ProposedACH(50) .000254 1168.7 64.16 120.66 .0881 5 4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Speed Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split Single HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split Single SEER:15 34.8 kBtu/hr cfm 0.85 1 sys#1 HOT WATER SYSTEM # . System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 50gal 60.9gal 120deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # CompanyName System Model# CollectorModel# Area Volume FEF None None ftz DUCTS / -- Supply-- — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area LeakageType Handler TOT OUT QN RLF Heat Cool 1 Attic 6 175 ft2 Attic 55 ftz DefaultLeakage Attic (Default) c(Default) c 1 1 TEMPERATURES ProgramableThermostat: Y Ceiling Fans: CoolingHlan Feb HeatinJan HFeb Mar Mar H Apr Ma Jun Jul Jun Jul Auge [ Aug Sep Oct Nov Dec HDec' Venting Jan Feb Mar Apr May Jun Jul [ ]Aug Sep Oct Lxl Nov ThermostatSchedule: HERS 2006 Reference Hours ScheduleType 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling(WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating(WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68' 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 .68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default(B.Ibs/sq.ft. 0 ftz 0 ft 0.3 MASTER BEDROO Default(8lbs/sq.ft. ftz ft 0.3 WIC Default(8lbs/sq.ft. ftz ft 0.3 MASTER BATH Default(8lbs/sq.ft. ftz ft 0.3 M. BATH Default(8lbs/sq.ft. ftz ft 0.3 LAUDRY Default(8lbs/sq.ft. ftz ft 0.3 BEDROOM 2 Default(8lbs/sq.ft. ftz ft 0.3 DINING/GREAT RO Default(8lbs/sq.ft. ftz ft 0.3 KITCHEN: 4/21 /2020 10:04 AM EnergyGauge® USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH Default(8lbs/sq.ft. ftz ft 0.3 HALL Defau lt(8 lbs/sq.ft. ftz ft 0.3 FOYER Default 81bs/s .ft. ftz ft 0.3 BEDROOM-3 4/21 /2020 10:04 AM EnergyGaugeO USA 6.0.02 (Rev.1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Owner: Jurisdiction: 4.1 Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION.INSTALLATION CRITERIA General A continuous. air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. . Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any dropped ceiling/soffit the insulation and any, gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top.plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The .space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to thetop of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts; penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed." Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spat s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in. exterior walls, or insulation that on installation readily conforms to available space shall extend -behind puping and wirong- Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box. or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall .be sealed to the sub -floor or.drywall. Concealed Whenr required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be.used to fill voids between fire sprinkler cover plates and walls or rell"n _- a. In addition, inspection of log _walls shall be in accordance with the provisions of [CC-400. 4/21/2020 10:05 AM EnergyGaugeO USA 6.0.02 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 9.7 The lower the Energy. Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location .& insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source.SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U=factor:(weighted average) 7a. 1.058 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.285 14. Heating'system: Capacity 34.8 c) Area 7c. 15.1.4 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.97 b) Gas.fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10131. 1.1.0 2. Masonry (Insulation R=value) 10132. 16. HVAC credits -claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 1la. 30.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11c. 19.0 d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy. .Conservation, through the above energy saving features which will be installed (or exceeded):in this home before final inspection. Otherwise, a new EPL display card will be completed based on instailed code compliant features. Builder Signature: Date: Address:of New Home b;� a".e `mil" City/FL Zip: FT. PIERCE. FL 4/21/2020 10:05:25 AM EnergyGauge® USA 6.0.04 (Rev. 1) - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1