Loading...
HomeMy WebLinkAboutProject Information ,Generac 0 GENERAIC 1 GUARDIAN° SERIES Residential Standby Generators Air-Cooled Gas Engine wom INCLUDES: Standby Power Rating • True Power'"" Electrical Technology • Two Line LCD Multilingual Digital Models G007036-0, G007037-0 (Aluminurn-Bisque) - 16 kVV 60 Hz Evolution'"' Controller (English/Spanish/ Model G007035-0 (Aluminum-Bisque)- 16 kV1/60 Hz French/Portuguese) i\Aodets G007039-0, G007038-0 (Aluminum-Bisque) -20 KVV 60 Hz • Two Transfer Switch Options Available: Models G007043-0, G007042-0 (Aluminurn-Bisque) -22 4<W 60 Hz 100 Amp, 16 Circuit Switch orate---� 200 Amp Service Rated Smart Switch. _ See Page 4 for Details. • Electronic Governor �'^• • System Status &Maintenance Interval LED �. Indicators ' IJENERAC • Sound Attenuated Enclosure - - i} , • Flexible Fuel Line Connector —�=- • Direct-To-Dirt Composite Mounting Pad ' • Natural Gas or LP Gas Operation C& QUIEHE-� _ • 5 Year Limited WarrantyLISTED Note:CUL certification only applies to unbundled units and units packaged with • Capability to be installed within 18" (457 mm) pre wired switches.Units packaged with the Smart Switch are UL certified in the USA only. of a building* *Only if located away from doors,windows and fresh air intakes, and unless otherwise directed by local codes. FEATURES O INNOVATIVE ENGINE DESIGN S RIGOROUS TESTING are at the heart of Generac's O SOLID-STATE,FREQUENCY COMPENSATED VOLTAGE REGULATION: success in providing the most reliable generators possible.Generac's G-Force engine This state-of-the-art power maximizing regulation system is standard an lineup offers added peace of mind and reliability for when you need it the most.The all Generac models.It provides optimized FAST RESPONSE to changing G-Force series engines are purpose built and designed to handle the rigors of load conditions and MAXIMUM MOTOR STARTING CAPABILITY by extended run times in high temperatures and extreme operating conditions. electronically torque-matching the surge loads to the engine. Digital voltage regulation at.0%. O TRUE POWER'" ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer form produce less than 5%Total Harmonic Distortion for utility quality power.This allows network provides parts and service know-how for the entire unit,from the confident operation of sensitive electronic equipment and micro-chip based appliances, engine to the smallest electronic component. such as variable speed HVAC systems. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are V PROTOTYPE TESTED V NEMA MGi-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this V SYSTEM TORSIONAL TESTED V MOTOR STARTING ABILITY confidence is that the GENERAL product line includes its own transfer systems and controls.for total system compatibility. w GENERAL rypl'•3� ,� 4��� • • Moblle ' PROMISE � *©* Unk i GENERAL® 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine"breathing"for increased fuel efficiency.Plateau honed cylinder walls and plasmamoly rings heipsthe engine run cooler,reducing oil consumption resulting in longer engine life. • "Spiny-lok"cast iron cylinder walls Rigid construction and added durability provide long engine life. • Electronic ignition/spark advance ' These features combine to assure smooth,quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance,less maintenance and longer engine life.Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller,light weight unit that operates 25%more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to±1%prevents damaging voltage spikes. • UL 2200 listed For your safety. Transfer Switch (if applicable) • Fully automatic Transfers your vital electrical loads to the energized source of power. • NEMA 3R Can be installed inside or outside for maximum flexibility. • Remote mounting Mounts near your existing distribution panel for simple,low-cost installation. Evolution— Controls • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy,at-a-glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history,maintenance and events up to 50 occurrences. • Sealed,raised buttons Smooth,weather-resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage,setpoints 65%dropout,80%pick-up,of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine,adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load,setpoint approximately 5 seconds. • Engine cool-down Allows engine to cool prior to shutdown,setpoint approximately 1 minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generator for 5 minutes every other week.Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM-style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature,withstanding winds up to 150 mph.Hinged key locking roof panel for security.Lift-out front for easy access to all routine maintenance items.Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet,critical grade muffler is mounted inside the unit to prevent injuries. • Small,compact,attractive Makes for an easy,eye appealing installation,as close as 181,away from a building. Installation System • 1 it(305 mm)flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct-to-dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. 0 Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine,prolonging engine life. GENERAL° 16/20/22 kW specifications Generator Model G007035-0,G007036-0, G007038-0,G007039.0 0007042-0,G007043.0 G007037-0(16 kW) (20 kW) (22 kW) Rated Maximum Continuous Power Capacity(LP) 16,000 Watts* 20,000 Watts' 22,000 Rated Maximum Continuous Power Capacity(NG) 16,000 Watts` 18,000 Watts` 19,500 Rated Voltage 240 240 240 Rated Maximum Continuous Load Current—240 Volts(LP/NG) 66.6/66.6 83,3/75 91.6/81.3 Total Harmonic Distortion Less than 5% Less than 5% Less than 5% r Main Line Circuit Breaker 70 Amp 100 Amp 100 Amp Phase 1 1 1 Number of Rotor Poles 2 2 2 Rated AC Frequency 60 Hz 60 Hz 60Hz Power Factor 1.0 1.0 1.0 Battery Requirement(not included) 12 Volts,Group 26R 540 CCA Minimum or Group 35AGM 650 CCA Minimum Unit Weight(lb/kg) 406/186 448/203 466/211 Dimensions(L x W x H)INmm 48 x 25 x29/1218 x 638 x 732 Sound output in dB(A)at 23 it(7 m)with generator operating at normal load" 66 66 67 Sound output in dB(A)at 23 It(7 m)with generator in Quiet-Test'low-speed exercise mode'" 58 58 58 Exercise duration 5 min 5 min 5 min Engine Type of Engine GENERAL G-Force 1000 Series GENERAC G-Force 1000 Series GENERAC G-Force 1000 Series Number of Cylinders 2 2 2 Displacement 999 cc 999 cc 999 cc Cylinder Block Aluminum w/Cast Iron Sleeve Valve Arrangement Overhead Valve Overhead Valve Overhead Valve Ignition System Solid-state w/Magneto Solid-state w/Magneto Solid-state w/Magneto Governor System Electronic Electronic Electronic Compression Ratio 9.5:1 9.5:1 9.5:1 Starter 12 Vdc 12 Vdc Oil Capacity Including Filter Approx 1.9.gV1.8 L Approx.1.9 gV1.8 L Approx 1.9 gV1.B L Operating rpm 3,600 3,600 3,600 Fuel Consumption Natural Gas 113/hr(0/hr) 112 Load 218(6.17) 204(5.78) 216(6,12) Full Load 309(8.75) 301(8.78) 310(8.78) Liquid Propane fP/hr(gal/hr)[Vhr] 112 Load 91.6(2.52)[9.53] 86(2.37)[8.99] 93.2(2,66)[9.70] Full Load 106.8(2.94)[11.11] 129.6(3.56)[13.48] 140(3.87)[14.65] Note:Fuel pipe must be sized for lull load.Required fuel pressure to generator fuel inlet at all load ranges-3.5-71 water column(7-13 mm mercury)for natural gas,10-12,water column(19-22 mm mercury) for LP gas For Btu content multiply ft3/hr x 2500(LP)or ft3/hr x 1000(NG).For Megajoule content,multiply m3/hr x 93.15(LP)or m3/hr x 37.26(NG) Controls 2-Line Plain Text Multilingual LCD Display Simple user Interface for ease of operation. Mode Bultons:Auto Automatic Start on Utility failure.7 day exerciser. Manual Start with slaver control,unit stays on.If utility fails,transfer to load takes place. Off Stops unit.Power is removed.Control and charger still operate. Ready to Run/Mainlenance Messages Standard Engine Run Hours Indication Standard Programmable start delay between 2-1500,seconds Standard(programmable by dealer only) Utility Voltage Loss/Retuin to Utility Adjustable(Brownout Setting) From 140-171 V/190-216 V Future Set Capable Exerciser/Exercise Set Error Warning - Standard Run/AlamVMalnlenance Logs 50 Events Each Engine Start Sequence Cyclic cranking:16 sec on,7 rest(90 sec maximum duration). Starter Lock-out Starter cannot re-engage until 5 sec after engine has stopped. Smart Battery Charger Standard Charger FaulVMissing AC Warning Standard Low Battery/Battery Problem Protection and Battery Condition Indication Standard Automatic Voltage Regulation with Over and Under Voltage Protection Standard Under-Frequency/Overload/Stepper Overcurrent Protection Standard Safety Fused/Fuse Problem Protection Standard Automatic low Oil Pressure/High Oil Temperature Shutdown Standard OvercranWOverspeed((g 72 Hz)/rpm Sense Loss Shutdown Standard High Engine Temperature Shutdown Standard Internal Fault/Incorrect Wiring Protection Standard Common External Fault Capability Standard Field Upgradable Firmware Standard "Sound levelsarelaW komthehontof the generator.Sound levels takm from other sides of thegeneratormaybe highadepending on Installation parameters.Rating deMlloos-Star":Applicabfefor supplying emergency powerfor the duration at lie di'dy pourer outage.No overload capability is available for this rating.(NI ratings in accordance with 8S5514,IS03045 and DiN5271).'Mar mum Idlovoilamps and current are subject to and limited by such factors as fuel Btu/mega)oule cordent,ambienttemperahce,aWbde,engine pow r and condition,eta Mardmum power decreases about3.5 percenlforeach 1.000 feet(304.8 meters)above sea level;and also will decrease about 1 percentfor each 6`C(10'F)above 16`C(60`0. GENERAC 16/20/22 kW switch options Limited Circuits Switch Features Model G007036-0(161kW) • 16 circuits,breakers not included. No.of Poles 2 • Electrically operated,mechanically-held contacts for fast,positive Current Rating(Amps) 100 Voltage Rating(VAC) 1201240,10 connections Utility Voltage Monitor(Fixed)* • Rated for all classes of load,100%equipment rated,both inductive and -Pick-up 80% resistive. -Dropout 65% r • 2 pole,250 VAC contactors. Return to utility* approx.15 sec • 30 millisecond transfer time. Exerciser bi-weekly for 5 minutes*t. Standard • Dual coil design. ULListed Standard • Rated for both copper and aluminum conductors. Total circuits available 16 • Main contacts are silver plated or silver alloy to resist welding and sticking. Tandem Breaker capabilities 8 spaces • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor Circuit Breaker Protected Available RMS Symmetrical 10,000 mounting flexibility. Fault current @ 250 Volts • Multi listed for use with 1"standard,tandem,GFCI and AFC(breakers from *Function of Evolution Controller Siemens,Murray,Eaton and Square D for the most flexible and cost effec- Exercise can be set to weekly or monthly live install. w, Dimensions 200 Amps 120/240,to Open Transition Service Rated Height Width Hz H1 H2 W1 I W2 Depth in 27.24 30.0 11.4 Lijil 7.09 mm 1 692.0 762.4 289.0 1 343.0 1 180.0 Note:The 50 amp switch is flush mountable.HI and W1 refer to mounting hole spacing. H2 and W2 are cover dimensions.H3 and W3 are the enclosure dimensions without cover. DrPiB L---w2— I Wire Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 210-#14 210-#14 Service Rated Smart Switch Features Model G007037.0(16 kW)/G007039.0(20 kW)/ • Includes Digital Power Management Technology standard(DPM). 0007043-0(22 kW) No.of Poles 2 • Intelligently manages up to four air conditioner loads with no additional Current Rating(Amps) 200 hardware. Voltage Rating(VAC) 120/240.10 Up to four more large(240 VAC)loads can be managed when used in Utility Voltage Monitor(Fixed)* conjunction with Smart Management Modules(SMMs. -Pick-up 80% 1 )• Electrically operated,mechanically-held contacts for fast,clean connections. -Dropout 65%Return to utility* approx 13 sec • Rated for all classes of load,100%equipment rated,both inductive and rests- Exerciser weekly for 5 minutes* Standard tI", UL Listed Standard • Up to four more large(120/240 VAC)loads can be managed when used in con- Enclosure type NEMANL 3R junction with 50 amp Power Management Modules(PMM**). circuit Breaker Protected 22;000 • 2 pole,260 VAC contactors. Lug Range 250 MCM-#6 • Service equipment rated,dual coil design. • Rated for both aluminum and copper conductors. Function of Evolution Controller • Main contacts are silver plated or silver alloy to resist welding and sticking. w, • NEMA/UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions H2 H, 200 Amps 120/240,1e Open Transition Service Rated Height Width Depth H1 H2 W1 W2 in 27.24 30.0 11.4 13.5 7.09 mm 692.0 762.4 289.0 343.0 180.0 oePrH I L—""`--I GENERAC mmumwmmum 16/20/22 kW available accessories Model# Product. Description 34 Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac- G006463-4 Mobile Link" cess to an Internet connection from a PC or with any smart device. You will even be notified via a-mail or text message when a change in the generator's status occurs. Available in the U.S.only. G0058i 9-0 26R Wet Cell Battery Every standby generator requires a battery to start the system.Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product(excluding PowerPact@). , G007101-0 Battery Pad Warmer The pad warmer rests under the battery:Recommended for use if the temperature regularly falls below 0°F. (Not necessary for use with AGM-style batteries). G007102-0 Oil Warmer oi warmer slips directly over the oil filter.Recommended for use if the temperature regularly falls below G007103-0 Breather Warmer The breather warmer is for use in extreme cold weather applications. For use with Evolution controllers only in climates where heavy icing occurs. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large electrical load Contact Kit you may not need.Not compatible with 50 amp pre-wired switches. Fascia Base Wrap Kit The fascia base wrap snaps together around the bottom of the new air cooled generators.This offers a G007027-0-Bisque (Standard on 22 kW) sleek,contoured appearance as welt as offering protection from rodents and insects by covering the Iihing holes located in the base. If the generator enclosure is scratched or damaged,it is important to touch-up the paint to protect from G005703-0-Bisque Paint Kit future corrosion.The paint kit includes the necessary paint to properly maintain or touch-up a generator enclosure. G006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Module Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its (50 Amps) power management capabilities.It provides additional power management flexibility notfound in any other power management system. dimensions & PCs Dimensions shown are approximate.Refer to installation manual for elect dimensions.DO NOT USE THESE DIMENSIONS FOR INSTALLATION PURPOSES. Model UPC Nye ienj--^--1 [aeA ln] G007035-0 696471070354 G007036-0 696471070361 G007037-0 696471070378 121 W1 G007038-0 696471070385 'X I G007039-0 696471070392 L rx _ n G007042-0 696471070422 i G007043-0 696471070439 L---.. --- —+zez mm -----�— r29.e In] rae.e M LEFT SIDE VIEW FRONT VIEW GENE RAC Generac Power Systems,Inc. - 545 W29290 HWY.59,Waukesha,Wi 53189 -generac.com ©2016 Generac Power Systems,Inc.All rights reserved.All specifications are subject la change without notice.Part No.10000000194-D 10/03/16 I GENERAC° Mai' � ���� �� GENERAC° ACCESSORIES Modules (SWA) Model 006873-0 GENERAC G UL US LISTED DESCRIPTION Generac's Smart Power Management System is designed to optimize the performance of a standby generator.The system can consist of up to 8 individual Smart Management Modules(SMM). Unlike other load management systems that depend on another control device,the SMM modules are actually self- aware and operate autonomously. Frequency is the true measure of generator engine performance and does not need to factor in increased ambient temperatures, elevation changes or generator fuel type.The modules,monitor the frequency(Hz)of the power being produced by Generac's standby generators and if it falls below a certain threshold,the module will automatically follow a power management algorithm to ensure that the generator is not overloaded. The modules can be set to a load priority between 1-8 or be set in a lock out only mode for loads that just simply do not need to run in an outage,therefore reducing the necessary size of the generator for a more cost effective solution. SMM SPECIFICATIONS PowerSupply Source............................................................................................................................................................................................................240 VAC(from Line Input) SupportedVoltages..........................................................................................................................................................................................................................................240 VAC ContactorCoil Voltage......................................................................................................................................................................................................................................240 VAC Coil VA Inrush............ .... ..........*"***.......................................................................................................................................................................................................................30 CoilVA Sealed....................................1.....................................................................................".............................................................................................................................6.5 Poles..................................................:.......................................................................................................................................................................................................................2 ResistiveAmps.........................................................................................................................................................................................................................................................50 F/L Inductive Amps...................................................................................................................................................................................................................................................40 LockedRotor Amps.....................................................................................................................................................................................................................................240@240V UI50............................................................................................................................................................................................................................................................ ...Yes Enclosure Rating NEMA 3R CENERAC° Smart Management Modules (SMM) Dimensions and UPC W1 W2 — T Model 006873-0 H1 6.17/155.8 Height(iNmm) H2 2.36/60 0 0 IN, 7.06/179.4 Width(iNmm) W2 4.72/120 H 1 HZ Depth(in/mm) 3.7/94 Weight(lbs/tdlos) 2.06/0.94 Shipping Weight(lbs/kilos) 2.44/1.11 o O UPC Code 696471068733 D1 V SMM Controls (located behind the cover of the module) B C LED ON LOAD CONNECTED LED FLASH 1S=LOAD SHED PRIORITY LOCKOUT LED FLASH 3S=30 MIN LOCKOUT S LOAD ON GENERATOR LED FLASH 8S=GEN LOAD LOCKOUT 3S 7 '--- LED OFF=NO MODULE POWER 0--- ® © 0 0 LOOKOUT TEST DISABLED Priority Dial(A)— • Sets module priority. Lockout Srrilch(B)— Prevents load from operating when system is operating under generator power. Test Button(C)— Disables contactor output for a specified time. LED(D)— Provides module status with easy vtelving through the external viewing window located in the upper right comer of the module. Generac Power Systems,Inc. o S45 W29290 HWY.59, Waukesha,WI 53189 • generac,com GE N E R AC I 02015 Sensrac Power Systems,Inc.All rights reserved.M specifications are subject to change without notice.Bulletin 00500.8 Printed in U.S.A.V404115 AMERICAST GENERA (ON-GRADE APPL � I GENERATOR - �� - - � AMER = I ryQ I 'MAD]L IN FED TAX LLJ 53 it3 0.8 2 523362 63 03 Pal" to Ave TO.772-971-19! F mil:e•1e,r­,nerl-Hn- - - \ �� HVHZ OR IN \ I - E RISK EXPOSURE(EXP) RISK PAD \\ I - - I C D II THICKNESS �� - - H 150 MPH 30.44 Psf 36.94 Psf 170 M PPp '� 156 MPH 32.92 Psf 39.95 Psf 170 M MIAMI-DADE 165 MPH 36.83 Psf 44.69 Psf 175 M ISOMETRIC VIEW PAD DIMENSIONS: CONCRETE PAD GENE GENERATOR TABLE: G - 2-1BRAND&MODEL CAPACITY WIDTH LENGTH HEIGHT WEIGHT ALLOWABLE PRESSURE Generac 005871&005883 SO KW 25.00" 48.00" 29.00" 387 Ibs 54.00 Psf EXP GENERATOR UNIT BY Generac 005872&005884 14KW 25.00" 48.00" 29.00" 439lbs 56.80 Psf o SEPARATE SUBMITTAL Generac 6459,6461,6462 16 KW 25.00" 48.00" 29.00" 513 Ibs 56.80 Psf 3 (SEE SCHEDULE FOR m I MINIMUM WEIGHT I Generac006721 16KW 25.00" 48.00" 29.00" 448lbs 56.80 Psf REQUIRED) Generac 005873&005885 17 KW 25.00" 48.00" 29.00" 455 Ibs 56.80 Psf Generac 005874&005886 17 KW 25.00" 48.00" 29.00" 421 Ibs 56.80 Psf U P Ll Generac 005875&005887 20 KW 25.00" 48.00" 29.00" 451 Ibs 56.80 Psf a. Generac 006729&006730 20 KW 25.00" 48.00" 29.00" 516 Ibs 56.80 Psf m Generac 006551&006552 22 KW 25.00" 48.00" 29.00" 526 Ibs 56.80 Psf 54"LENGTH Kohler 14RES&20RES 14-20 KW 26.00" 48.00" 29.00" 500 Ibs 56.80 Psf PLAN VIEW GE 40323GE&40324GE 13 KW 35.00" 39.40" 39.00" 540 Ibs 49.50 Psf EXP d GE 04038215KW 15 KW 33.00" 48.00" 30.50" 484 Ibs 56.80 Psf 0 M CONCRETE PAD GE 04037817KW 17 KW 33.00" 48.00" 30.50" 484 Ibs 56.80 Psf UPI co GE 40330GE&40331GE 20 KW 33.00" 48.00" 30.50" 600 Ibs 56.80 Psf ROAD MESH Briggs&Stratton 040243-0 SO KW 31.00" 32.00" 34.00" 430 Ibs 56.80 Psf p, MASTERFIBER 3"MIN 4"MIN 3 MAC100 Briggs&Stratton 040302-2 12 KW 33.75" 50.00" 31.60" 507 Ibs 54.00 Psf EXP GROUND „ >;;;. :;;:;,;, Briggs&Stratton 040303-1 15 KW 33.75" 49.00" 31.60" 562 lbs 56.80 Psf :7 �' /_f /," Briggs&Stratton 040304 1 18 KW 33.75" 49.00" 31.60" 568 Ibs 56.80 Psf UP Briggs&Stratton 040305-1 20 KW 33.75" 49.00" 31.60" 570 Ibs 56.80 Psf m -0 50" 54" eo GENERATOR MOUNTING CONFIGURATION: GENERATOR GENERATOR ATTACHMENT BASE w OR SIMPSON A24 ANGLE BRACE W/(4)#10 SS 316 SELF-DRILLING io SCREWS Q Q TO GENERATOR (SEE GENERATOR SPECS) d Q ? 3/8"THICK GALVANIZED D. WASHER&RUBBERGENE / ~ I (SEE ONCATOR RETE PAD VIBRATION PAD = S V' L9 SCHEDULE FOR w I I I DIMENSIONS&WEIGHT _ REQUIRED) CONCRETE PAD 6,000 PSI N n I- LIGHTWEIGHT 4" n J1J I CONCRETE MIX I o }----32"WIDTH }--- 54" LENGTH 1OTY DISTANCE DEPEND ON GENERATOR BASE LENGTH,N N 2. X DISTANCE 3"FROM UNIT EDGE TO CLIP. SIDE VIEW FRONT VIEW 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH,N� N ANCHOR REQUIREMENTS 0 FRANK L BENNARDO,P.E. TOR CONCRETE PAD PE*0046549 '.CATIONS ONLY) WIND DESIGN REQUIREMENTS: (-= (BASED ON ASCE 7-10&FLORIDA BUILDING CODE FIFTH EDITION(2014)) v�ID�onr.�Pauss�®a+ AT-GRADE SIGN METHOD FRANK L BENNARDO,P.E. ULTIMATE DESIGN WIND SPEED Vult= 186 mph 549 A ONLY NOMINAL DESIGN WIND SPEED Vasd=144 mph ALIDFORI PERMITB*MMN.O. SEAL/•� RISK CATEGORY=III INTERNAL PRESSURE COEF=N/A ALIDOIIIYWfIHORIC'INALEH esllnn.w _ EXPOSURE CATEGORY=D WIND DIRECTIONALITY FACTOR Kd=0.85 �D N aU ENSE9599-20050163 ENCLOSURE CATEGORY=N/A HEIGHT H=AT GROUND O V �Q LICENSE 1H x Fon Pierce,Fl.34982 GUST EFFECT FACTOR=0.85 PRESSURE AT HEIGHT H qh=77.56 Ib/ft2 z qIt t�/iUU FCa:772-464-0509 ® W M t� o grch a rlesnlp2nOJra'•'eh"a.anm FORCE COEFFICIENT Cf= 1.44 M yj O WIND PRESSURE: W� ��- gym )N-HVHZ P=qh G Cf=56.80 Ib/ft2(ASD.) u- LL w EXPOSURE(EXP) RISK EXPOSURE(EXP) Zr O `M A O a GENERAL NOTES z P> <LLv6 C D III,IV Z Lu H 39.09 Psf 47.44 Psf 180 MPH 43.83 Psf 53.19 Psf 1. THIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED �-+`� 0=w z Z o H 39.09 Psf 47.44 Psf 180 MPH 43.83 Psf 53.19 Psf IN ACCORDANCE WITH THE REQUIREMENTS OF THE 2014 z n.,N m ( ce FLORIDA BUILDING CODE(Sth EDITION). W W O N OJ M w W u H 41.43 Psf 50.28 Psf 186 MPH 46.80 Psf 56.80 Psf 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR V'i w R p w USE WITH THIS SYSTEM SHALL BE DETERMINED UNDER 3 lLL°:�(7 SEPARATE CERTIFICATION ON A JOB-SPECIFIC BASIS IN N d a ZED ACCORDANCE WITH THE GOVERNING CODE.SITE-SPECIFIC O lu w w LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH THE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR 74 0 EQUAL TO THE DESIGN PRESSURE"ASD"CAPACITY VALUES LISTED HEREIN FOR ANY ASSEMBLY AS SHOWN. 3. DIMENSIONS AND WEIGHT OF UNITS SHALL CONFORM TO ANCHOR TO PAD SCHEDULE: SPECIFICATIONS STATED HEREIN. COMMENTS 4. UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES Uj .. HAVING EQUAL CLEARANCE.'A MINIMUM DISTANCE FROM UNIT Q fL 00 1P6 MPH&D 180 MPH SUBSTRATE DESCRIPTION TO PAD EDGE IS SPECIFIED. �I `Ln 0 5. THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE Q O U cri ALL VEGETATION,STUMPS,ROOTS,AND FOREIGN MATERIALS U L 2 ' eV O Z CONCRETE: (2)-3/8"p1 TITEN HD REMOVED PRIOR TO INSTALLATION ON COMPACTED SOIL AS in �a O (6000 PSI OR EQUIVALENT, J a O MIN.) 2-3/4"FULL EMBED VERIFIED BY OTHERS. Q N � J Q O CONCRETE,3"MIN 6. RESISTANCE TO SLIDING OF THE PAD ON THE GROUND IS NOT Lu M O n Z w EDGE DISTANCE,6" PART OF THIS DOCUMENT AS SOIL CHARACTERISTICS AND PAD EXPOSURE D 186 MPH MIN.SPACING TO ANY PLACEMENT VARIES: L c N ADJACENT ANCHOR. 7. ELECTRICAL GROUND,WHEN REQUIRED,TO BE DESIGNED& Q lu INSTALLED BY OTHERS.ALL MECHANICAL SPECIFICATIONS cs w w (CLEAR SPACE,TONNAGE,ETC.)SHALL BE AS PER CO N 0 NOTES: MANUFACTURER RECOMMENDATIONS AND ARE THE EXPRESS 12 O 1. ANCHOR QUANTITY PER LONG SIDE RESPONSIBILITY OF THE CONTRACTOR. 2. EMBEDMENT AND EDGE DISTANCE 8. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL n N EXCLUDES FINISHES,IF DESIGN AS SHOWN ONLY. USE OF THIS SPECIFICATION BY ��/� 186 MPH&D 170 MPH APPLICABLE. CONTRACTOR,et.al.INDEMNIFIES&SAVES HARMLESS THIS 3. ENSURE MINIMUM EDGE DISTANCE ENGINEER FOR ALL COST&DAMAGES INCLUDING LEGAL FEES &.� r+ �jj O AS NOTED IN ANCHOR SCHEDULE. &APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, e`c' -i w Q m MINIMUM SPACING TO 4. ENSURE M Q EXPOSURE D 186 MPH SYSTEM ERECTION,CONSTRUCTION PRACTICES BEYOND THAT V.Fe z a t C ANY ADJACENT ANCHORS. -" r� S. FOLLOW MANUFACTURER'S WHICH IS CALLED FOR BY LOCAL,STATE,&FEDERAL CODES& Z z Y. FROM DEVIATIONS OF THIS PLAN. !^a INSTALLATION INSTRUCTIONS TO 9 WATER-TIGHTNESS OF EXISTING FINISHES SHALL BE THE FULL P_AFg O LL 186 MPH&D 180 MPH INSTALL ANCHORS: RESPONSIBILITY OF THE INSTALLING CONTRACTOR. F o CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED ''^s EXPOSURE D 186 MPH WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE PROPOSED GENERATOR HEREIN.THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY 1� k WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS a ATTACHMENT BASE, WATER-TIGHTNESS SHALL BE THE FULL RESPONSIBILITY OF p VARIES WITH MODEL THE INSTALLING CONTRACTOR. C SEE GENERATOR SPECS 10. THE ROLE OF THIS ENGINEER FOR THIS PROJECT IS THAT OF Q SIMPSON TITEN HD, SPECIALTY ENGINEER AND NOT THE ENGINEER OF RECORD. v SEE ANCHOR SCHEDULE CONSEQUENTLY,THE ARCHITECT/ENGINEER OF RECORD SHALL 2"x3"x3/e"GALV.STEEL BE RESPONSIBLE FOR THE INTEGRTTY OF ALL SUPPORTING 1 O $ 1 WASHER i SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED C g RUBBER VIBRATION PAD BY THE PERMITTING CONTRACTOR. 11. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY $�$SPECIFIC PROJECT SITE.INFORMATION CONTAINED HEREIN IS ' $ 3 ' BASED ON CONTRACTOR-SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS OR INACCURATE DATA EE Z CONCRETE PAD OR MEASUREMENTS.DIMENSIONS ARE SHOWN TO ILLUSTRATE 6,000 PSI DESIGN FORCES AND OTHER DESIGN CRITERIA.THEY MAY z LIGHTWEIGHT �' VARY SLIGHTLY,BUT MUST REMAIN WITHIN THE LIMITATIONS - CONCRETE MIX �i!j�ii; SPECIFIED HEREIN.WORK SHALL BE FIELD VERIFIED BY COPMGKr ENGINEERING EXPRESS® !/ ��/ �i� !' ! �/- OTHERS PRIOR TO CONSTRUCTION.ENGINEERING EXPRESS MASTERFIBER MAC 100 j j!//i%j j/j i% SHALL BE NOTIFIED AND GIVEN AN OPPORTUNITY TO 17-3961.1 &ROAD MESH i �j �i ;i!,�j,;=�i REEVALUATE OUR WORK UPON DISCOVERY OF ANY SCALE:NTS UNLESS NOTED INACCURATE INFORMATION PRIOR TO MODIFICATION OF FOAM CORE Z� EXISTING FIELD CONDITIONS AND FABRICATION AND °F{� LESS THAN 2". INSTALLATION OF MATERIALS.ALTERATIONS OR ADDITIONS II TO THIS DOCUMENT ARE NOT PERMITTED AND INVALIDATE �7 -ESS THAN OUR CERTIFICATION. 12. EXCEPT AS EXPRESSLY PROVIDED HEREIN,NO ADDITIONAL CERTIFICATIONS OR AFFIRMATIONS ARE INTENDED.